991 resultados para RADIATION SOURCE IMPLANTS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, initial crystallographic studies of human haemoglobin (Hb) crystallized in isoionic and oxygen-free PEG solution are presented. Under these conditions, functional measurements of the O-2-linked binding of water molecules and release of protons have evidenced that Hb assumes an unforeseen new allosteric conformation. The determination of the high-resolution structure of the crystal of human deoxy-Hb fully stripped of anions may provide a structural explanation for the role of anions in the allosteric properties of Hb and, particularly, for the influence of chloride on the Bohr effect, the mechanism by which Hb oxygen affinity is regulated by pH. X-ray diffraction data were collected to 1.87 Angstrom resolution using a synchrotron-radiation source. Crystals belong to the space group P2(1)2(1)2 and preliminary analysis revealed the presence of one tetramer in the asymmetric unit. The structure is currently being refined using maximum-likelihood protocols.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In dieser Arbeit wird eine kontinuierliche, kohärente Strahlungsquelle bei 121,56nm, der Lyman-alpha Linie in Wasserstoff, vorgestellt. Diese Lyman-alpha Quelle soll zur zukünftigen Laserkühlung von Antiwasserstoff dienen. Die Strahlung wird durch Vier-Wellen-Mischen in Quecksilberdampf produziert. Dabei wird ein Festkörperlasersystem zur Erzeugung der Fundamentalstrahlen eingesetzt. Zur Erhöhung der nichtlinearen Suszeptibilität wird die 6^1S-7^1S Zwei-Photonen-Resonanz ausgenutzt. Zusätzlich wird mit Hilfe eines durchstimmbaren ultravioletten Lasersystems die 6^1S-6^3P Ein-Photon-Resonanz genutzt, was es erlaubt, die nichtlineare Suszeptibilität des Mischprozesses um Größenordnungen zu erhöhen. Um den Einfluss der 6^1S-6^3P Ein-Photon-Resonanz zu untersuchen, wurden zunächst die Phasenanpassungstemperaturen bei verschiedenen Verstimmungen der ultravioletten Strahlung zur 6^3P Resonanz vermessen und festgestellt, dass kleinere Verstimmungen zu niedrigeren Phasenanpassungstemperaturen führen. Es konnte sowohl theoretisch wie auch experimentell gezeigt werden, dass diese niedrigeren Phasenanpassungstemperaturen bei kleinen Verstimmungen der Erhöhung der Lyman-alpha Erzeugung durch die größere nichtlineare Suszeptibilität bei kleinen Verstimmungen entgegenwirken. Bei immer kleineren Verstimmungen zur 6^3P Resonanz limitiert die Absorption der ultravioletten Strahlung die Lyman-alpha Erzeugung. Ein positiver Effekt der niedrigeren Phasenanpassungstemperaturen ist, dass es möglich wird, auf das bisher nötige Puffergas in der Quecksilber-Dampfzelle zu verzichten, was die Lyman-alpha Erzeugung um einen Faktor 1,7 erhöht. Damit war es möglich, die bisherige Effizienz der Lyman-alpha Erzeugung zu verbessern. Es wurde eine Lyman-alpha Leistung von 0,3nW erreicht. Zusätzlich zum Einfluss der 6^3P Resonanz auf die Lyman-alpha Erzeugung wurde ein weiterer Effekt beobachtet. Durch die Nähe der 6^1S-6^3P Ein-Photon-Resonanz wird auch mehr Besetzung in das obere 7^1S Niveau der Zwei-Photonen-Resonanz gepumpt. Dadurch konnte erstmals eine kontinuierliche Lasertätigkeit auf der 6^1P-7^1S Linie in Quecksilber bei 1014nm beobachtet werden.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In dieser Arbeit wird eine kohärente, kontinuierliche Strahlungsquelle im vakuum-ultravioletten (VUV) Spektrum vorgestellt. Sie basiert auf einem Vierwellenmischprozess in Quecksilberdampf mit Fundamentalstrahlen bei 253,7 nm, 407,9 nm und 545,5 nm Wellenlänge. Diese fundamentalen Strahlen werden durch frequenzverdoppelte bzw. frequenzvervierfachte Festkörperlasersysteme bereit gestellt. Durch das Ausnutzen der 6^1S-7^1S Zweiphotonenresonanz und zusätzlich der 6^1S-6^3P Einphotonenresonanz kann der Vierwellenmischprozess deutlich effizienter betrieben werden als zuvor. Eine nahe Einphotonenresonanz verringert die optimale Phasenanpassungstemperatur des Vierwellenmischprozesses, wodurch Druck- und Stoßverbreiterungen des Quecksilbers verkleinert und damit der nichtlineare Prozess effizienter wird. So können Leistungen bis zu 0,3 nW bei 121,56 nm, dem 1S-2P Lyman-alpha Übergang von Wasserstoff, erzeugt werden. Diese Lyman-alpha Quelle soll für die zukünftige Laserkühlung von Antiwasserstoff genutzt werden. rnrnNeben der Generierung von Strahlung bei Lyman-alpha kann, durch Veränderung der dritten Fundamentalwellenlänge, auch Strahlung in der Nähe zu einer Einphotonresonanz im VUV bei dem 6^1S-12^1P Übergang in Quecksilber durch Vierwellenmischen erzeugt werden. Durch diese weitere Einphotonresonanz kann die nichtlineare Suszeptibilität, verantwortlich für das Vierwellenmischen, stark vergrößert werden, ohne Einfluss auf die Phasenanpassung zu haben. Damit lässt sich der Mischprozess um drei Größenordnungen effizienter gestalten und Leistungen von 6 µW im VUV konnten realisiert werden. Dies entspricht einer Leistungsteigerung um einen Faktor 30 im Vergleich zu früheren Quellen. rnrnDarüberhinaus konnte die Zweiphotonenresonanz in Quecksilber ausführlich untersucht werden. Man erhält bei kleinen Rabifrequenzen der Fundamentalstrahlen eine geschwindigkeitsselektive Doppelresonanz, die den gleichen Ursprung wie Dunkelresonanzen in Lambda-Systemen hat. Bei hohen Rabifrequenzen kann die Anregung in das Zweiphotonenniveau so stark werden, dass auf dem 7^1S-6^1P Übergang ein Laserprozess initiiert wird. Dieser Prozess wurde hier zum ersten Mal mit kontinuierlichen Fundamentallasern nachgewiesen. Es wird gezeigt, dass der zusätzliche Laserprozess das Vierwellenmischen nicht beeinträchtigt.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC source model (with target, primary collimator, and flattening filter photon subsources and an electron subsource) for 6- and 18-MV photon beams when the energy and radial distributions of initial electrons striking a linac target change. For this purpose, phase-space data (PSD) was calculated for various mean electron energies striking the target, various normally distributed electron energy spread, and various normally distributed electron radial intensity distributions. All PSD was analyzed in terms of energy, fluence, and energy fluence distributions, which were compared between the different parameter sets. The energy spread was found to have a negligible influence on the subsource distributions. The mean energy and radial intensity significantly changed the target subsource distribution shapes and intensities. For the primary collimator and flattening filter subsources, the distribution shapes of the fluence and energy fluence changed little for different mean electron energies striking the target, however, their relative intensity compared with the target subsource change, which can be accounted for by a scaling factor. This study indicates that adjustments to MC source models can likely be limited to adjusting the target subsource in conjunction with scaling the relative intensity and energy spectrum of the primary collimator, flattening filter, and electron subsources when the energy and radial distributions of the initial electron-beam change.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The new Bern cyclotron laboratory aims at industrial radioisotope production for PET diagnostics and multidisciplinary research by means of a specifically conceived beam transfer line, terminated in a separate bunker. In this framework, an innovative beam monitor detector based on doped silica and optical fibres has been designed, constructed, and tested. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam is measured, giving information on beam position, shape, and intensity. The doped fibres are coupled to commercial optical fibres, allowing the read-out of the signal far away from the radiation source. This general-purpose device can be easily adapted for any accelerator used in medical applications and is suitable either for low currents used in hadrontherapy or for currents up to a few μA for radioisotope production, as well as for both pulsed and continuous beams.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Theoretical X-ray opacities are used in numerous radiative transfer simulations of plasmas at different temperatures and densities, for example astrophysics, fusion, metrology and EUV and X-rays radiation sources. However, there are only a reduced number of laboratories working on the validation of those theoretical results empirically, in particular for high temperature plasmas (mayor que 1eV). One of those limitations comes from the use of broad band EUV- X ray sources to illuminate the plasma which, among other issues, present low reproducibility and repetition rate [1]. Synchrotron radiation facilities are a more appropriate radiation source in that sense, since they provide tunable, reproducible and high resolution photons. Only their ?low? photon intensity for these experiments has prevented researchers to use it for this purpose. However, as new synchrotron facilities improve their photon fluxes, this limitation not longer holds [2]. This work evaluates the experimental requirements to use third generation synchrotron radiation sources for the empirical measurement of opacities of plasmas, proposing a pausible experimental set-up to carry them out. Properties of the laser or discharge generated plasmas to be studied with synchrotron radiation will be discussed in terms of their maximum temperatures, densities and temporal evolution. It will be concluded that there are encouraging reasons to pursue these kind of experiments which will provide with an appropriate benchmark for theoretical opacities

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We investigated the adaptive significance of behavioural thermoregulation in univoltine populations of the grasshopper Melanoplus sanguinipes along an altitudinal gradient in California using laboratory tests of animals raised under different temperatures. Trials consisted of continuous body temperature measurements with semi-implanted microprobes in a test arena, and observation and simultaneous recording of behavioural responses. These responses included mobility, basking and orientation of the body axes (aspect angle) towards a radiation source. Mobility and basking are determined by the altitudinal origin of the parental generation and not by the temperature treatments. With increasing altitude, individuals tend increasingly to raise body temperatures via mobility and increased basking. In contrast, body orientation towards the radiation source is influenced by the temperature treatments but not by the altitude of origin. Individuals experiencing higher temperatures during rearing show a lower tendency to lateral flanking. We conclude that body orientation responses are not adapted locally. In contrast other components of the behavioural syndrome that increase body temperature, such as mobility and basking, are adaptive in response to local selection pressure. The thermoregulatory syndrome of these grasshoppers is an important contribution to life-history adaptations that appropriately match season lengths.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The reaction of 1,3-bis(tetrazol-1-yl)-2-propanol (btzpol) with Fe(BF4)2 · 6H2O in acetonitrile yields the remarkable 2D coordination polymer [FeII(btzpol)1.8(btzpol-OBF3)1.2](BF4)0.8 · (H2O)0.8(CH3CN) (1). This compound has been structurally characterized using an X-ray single-crystal synchrotron radiation source. The iron(II) centers are bridged by means of double btzpol bridges along the c direction, and by single btzpol bridges along the b direction. The reaction of part of the ligand with the counterion has forced the compound to crystallize in this extended two dimensional structure. The compound shows spin-transition properties, both induced by temperature and light, with T½ = 112 K and T(LIESST) = 46 K, respectively. The relaxation of the metastable high-spin state created by irradiation is exponential, following an Arrhenius type behavior at high temperature, and dominated by a temperature independent tunneling process at lower temperatures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gold nanoparticles (GNPs) have shown potential to be used as a radiosensitizer for radiation therapy. Despite extensive research activity to study GNP radiosensitization using photon beams, only a few studies have been carried out using proton beams. In this work Monte Carlo simulations were used to assess the dose enhancement of GNPs for proton therapy. The enhancement effect was compared between a clinical proton spectrum, a clinical 6 MV photon spectrum, and a kilovoltage photon source similar to those used in many radiobiology lab settings. We showed that the mechanism by which GNPs can lead to dose enhancements in radiation therapy differs when comparing photon and proton radiation. The GNP dose enhancement using protons can be up to 14 and is independent of proton energy, while the dose enhancement is highly dependent on the photon energy used. For the same amount of energy absorbed in the GNP, interactions with protons, kVp photons and MV photons produce similar doses within several nanometers of the GNP surface, and differences are below 15% for the first 10 nm. However, secondary electrons produced by kilovoltage photons have the longest range in water as compared to protons and MV photons, e.g. they cause a dose enhancement 20 times higher than the one caused by protons 10 μm away from the GNP surface. We conclude that GNPs have the potential to enhance radiation therapy depending on the type of radiation source. Proton therapy can be enhanced significantly only if the GNPs are in close proximity to the biological target.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mastoparans are tetradecapeptides found to be the major component of vespid venoms. A mastoparan toxin isolated from the venom of Anterhynchium flavomarginatum micado has been crystallized and X-ray diffraction data collected to 2.7 Angstrom resolution using a synchrotron-radiation source. Crystals were determined to belong to the space group P6(2)22 (P6(4)22). This is the first mastoparan to be crystallized and will provide further insights into the conformational significance of mastoparan toxins with respect to their potency and activity in G-protein regulation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The motion due to an oscillatory point source in a rotating stratified fluid has been studied by Sarma & Naidu (1972) by using threefold Fourier transforms. The solution obtained by them in the hyperbolic case is wrong since they did not make use of any radiation condition, which is always necessary to get the correct solution. Whenever the motion is created by a source, the condition of radiation is that the sources must remain sources, not sinks of energy and no energy may be radiated from infinity into the prescribed singularities of the field. The purpose of the present note is to explain how Lighthill's (1960) radiation condition can be applied in the hyperbolic case to pick the correct solution. Further, the solution thus obtained is reiterated by an alternative procedure using Sommerfeld's (1964) radiation condition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Based on the 2 x 2 (electric field) cross-spectral density matrix, a model for an electromagnetic J(0)-correlated Schell-model beam is given that is a generalization of the scalar J(0)-correlated Schell-model beam. The conditions that the matrix for the source to generate an electromagnetic J(0)-correlated Schell-model beam are obtained. The condition for the source to generate a scalar J(0)-correlated Schell-model beam can be considered as a special case. (C) 2008 Optical Society of America