919 resultados para Pure-tone Thresholds


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diabetes Mellitus may lead to alterations in the eyes, kidneys, cranial nerves, peripheral nerves, ears etc. The cognitive function, also, seems to be compromised in subjects presented with Diabetes Mellitus, since the cortical and subcortical structures responsible for this function are hindered in some insulin-dependent patients. The cognitive potential P300 has been used as an objective procedure to assess cerebral cognitive functions. Objective: Analyze the sensitivity of P300 cognitive potential for the detection of alterations on the auditory cortex secondary to Diabetes Mellitus. Study design: transversal cohort. Material and Method: Sixteen diabetic subjects of both genders aged 7 to 71 years, and seventeen non-diabetic individuals at the same age range participated in this study, the evaluation procedures were pure tone audiometry (PTA) and P300 cognitive potential. Glycemia of the group presented with Diabetes was assessed prior to applying the P300. Results: No statistically significant difference was shown for the PTA results. A statically significant difference was observed between groups when analyzing the latency of the P300 component measured in Fz. there was a correlation between glycemia and the latency and amplitude of P300. Conclusion: The investigation of the cognitive potential of P300 is an important procedure for the prevention and early diagnosis of neurological changes in individuals presented with Diabetes Mellitus.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The present study aimed at evaluating the occurrence and recurrence of middle ear effusion and possible associated factors in the first two years of life of 190 newborns and infants, participants in the interdisciplinary prevention, detection, and intervention program at the Clínica de Educação para Saúde of Universidade do Sagrado Coração. Methods: Newborns and infants were monthly submitted to anamneses, otoscopy, behavioral hearing assessment using sound instruments and pure tones (pediatric audiometry) and tympanometry. Results: The results revealed that 68.4% of infants presented one or more episodes of middle ear effusion during their two first years, with more recurrence among males. Peak occurrence was between four and 12 months of age and, the earlier the first episode, the higher the probability of recurrence. Greatest incidence was during May and August. It was found that, of the variables investigated, the period of exclusive breastfeeding actuated as a protector factor. With respect of risk factors, it was observed that passive smoking, gastro-esophageal reflux and respiratory allergy were related with the recurrences of effusion. Conclusion: Findings revealed the importance of periodic auditory follow-up for infants during their first two years of life, considered to be the critical period of auditory system maturation, during which sensory deprivation can be responsible for damage to the development of speech, language and other auditory abilities. © 2007 Sociedad Chilena de Pediatría.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hearing loss and tinnitus impact the lives of workers in every instance of their lives. Aim: this paper aims to investigate the existence of a dose-response relationship between hearing loss and tinnitus by determining whether higher levels of hearing loss can be associated with increased tinnitus-related discomfort. Materials and method: this cross-sectional case study assessed 284 workers exposed to occupational noise through pure tone audiometry. Test results were categorized as defined by Merluzzi. Individuals complaining of tinnitus answered the adapted and validated Brazilian Portuguese version of the Tinnitus Handicap Inventory. A generalized linear model was adjusted for binomial data to test the interaction between these factors. Results: over 60% of the ears analyzed had hearing loss, while more than 46% of them had tinnitus. Tinnitus prevalence and risk rates increased as pure tone audiometry results got worse. The association between both, considering all hearing loss degrees, was statistically significant. Conclusion: the results point to a statistical association between hearing loss and tinnitus; the greater the hearing loss, the greater the discomfort introduced by tinnitus. 2009 © Revista Brasileira de Otorrinolaringologia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Otoacoustic emissions can be an alternative for cochlear evaluation in noise induced hearing loss (NIHL). Objective: To investigate the correlation between the findings of audiometry results and distortion product otoacoustic emissions (DPOAE) in the military police. Method: from cross-sectional and retrospective study, 200 military police officers were submitted to audiological evaluation - pure tone audiometry and DPOAE. Results: considering the provisions of Ordinance 19 of the Labour Department, the results were suggestive of induced hearing loss by high sound pressure levels in 58 individuals, distributed as follows: 28 (48.3%) bilateral cases and 30 (51.7%) unilateral cases, and 15 (25.85%) in each ear. The correlation between the audiometric and DPOAE showed statistical significance in most of the frequencies tested in both ears, confirming that the greater the degree of hearing loss, the smaller the DPOAE amplitudes. In addition, there was observed significant difference between the DPOAEs amplitudes of normal subjects and listeners with hearing loss, confirming the lowering of responses in the group with hearing loss. Conclusion: considering that the correlation between pure tone audiometry and DPOAE, we conclude that otoacoustic emissions can be a complementary tool for the detection and control of NIHL in military police.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The biological processes involved in noise-induced hearing loss (NIHL) are still unclear. The involvement of inflammation in this condition has been suggested.Objective: To investigate the association between interleukin - 6 (IL-6) polymorphism and susceptibility to NIHL.Methods: This was a cross-sectional study with a sample of 191 independent elderly individuals aged >60 years of age. Information on exposure to occupational noise was obtained by interviews. Audiological evaluation was performed using pure tone audiometry and genotyped through PCR by restriction fragment length polymorphism - PCR-RFLP. Data were analyzed using the chi-square test and the odds ratio (OR), with the significance level set at 5%.Results: Among elderly with hearing loss (78.0%), 18.8% had a history of exposure to occupational noise. There was a statistically significant association between the genotype frequencies of the IL-6 - 174 and NIHL. The elderly with the CC genotype were less likely to have hearing loss due to occupational noise exposure when compared to those carrying the GG genotype (OR = 0.0124; 95% CI 0.0023-0.0671; p<0.001).Conclusion: This study suggests there is an association of polymorphisms in the IL-6 gene at position - G174C with susceptibility to noise-induced hearing loss. (C) 2014 Associacao Brasileira de Otorrinolaringologia e Cirurgia Cervico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To evaluate the hearing status of patients being treated for pulmonary tuberculosis at referral hospitals in Brazil. Methods: This was a descriptive study involving 97 male and female inpatients/outpatients between 18 and 60 years of age who were undergoing treatment for active pulmonary tuberculosis at one of two referral hospitals in the state of Rio de Janeiro. After being interviewed, all of the patients underwent pure tone audiometry. Results: OF the 97 patients studied, 65 (67%) were male, 52 (54%) were receiving first-line treatment, and 45 (46%) were receiving second-line treatment, which included aminoglycosides. Smoking, alcohol consumption, exposure to noise, and ototoxic medication use were identified in 65 (67%), 51 (53%), 53 (55%), and 45 (46.4%) of the patients, respectively. The most common auditory and vestibular complaints were dizziness, in 28 patients (28.8%); tinnitus, in 27 (27.8%); and hypoacusis, in 23 (23.7%). Conclusions: Due to the great number of patients with hearing loss in the present study, we recommend that all patients under tuberculosis treatment be submitted to auditory monitoring.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract Objective To evaluate the functionality of the auditory system in patients who underwent radiotherapy and chemotherapy treatment with cisplatin to treat head and neck tumors. Study Design Case series with planned data collection. Setting From May 2007 to May 2008 by the Department of Otorhinolaryngology and the Department of Oncology/Radiotherapy at Faculdade de Medicina de Marília. Subjects and Methods Audiological evaluation (Pure Tone Audiometry (air and bone conduction), Speech Audiometry, Tympanometry, Acoustic Reflex testing and Distortion Product Otoacoustic Emissions) was performed in 17 patients diagnosed with head and neck neoplasia and treated with chemotherapy, using cisplatin, and radiotherapy. Results 12 left ears (70.5%) and 11 right ears (64.7%) presented bilateral decreased hearing soon after the treatment for the frequency 1 kHz (mild auditory damage) and for the frequency 8 kHz (more significant auditory damage). Conclusion Patients with head and neck cancer submitted to the conventional radiotherapy treatment, combined with the chemotherapy with cisplatin, presented a high incidence of decreased hearing by the end of treatment. Strong evidence was observed linking auditory alteration to the amount of radiotherapy treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. Aim: To evaluate the TS audiometer for conducting audiometric screening. Methods: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. Results: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. Conclusions: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUÇÃO: A perda auditiva relacionada ao trabalho é uma das doenças ocupacionais mais frequentes, progride ao longo dos anos de exposição ao ruído associado ao ambiente de trabalho, podendo causar prejuízos que comprometem as atividades físicas, fisiológicas e mentais do indivíduo além de causar lesão auditiva irreversível interferindo na comunicação e na qualidade de vida. Com alto índice de prevalência masculina, avalia-se que seja a segunda maior causa de perda de audição. Uma vez que não existe tratamento clínico para esse tipo de perda auditiva, fica evidente a importância de ações preventivas e coletivas que visem à conservação da audição e da saúde como um todo. OBJETIVO: Avaliar a prevalência de perdas auditivas nas audiometrias admissionais de motoristas. MÉTODO: Estudo retrospectivo. Participaram 76 prontuários de motoristas profissionais locados em empresas de transporte. Foram analisados os dados de entrevista específica e Audiometria Tonal Liminar. RESULTADOS: A prevalência de exames alterados foi de 22,36% com piores limiares para a média tritonal de 3.000, 4000 e 6.000Hz. Quanto maior a idade, maior os limiares auditivos. CONCLUSÃO: Este estudo permitiu evidenciar a ocorrência de alterações auditivas na ausência de queixas. Considerando que a PAIR é passível de prevenção, justifica-se a importância de ações coordenadas e multidisciplinares envolvendo, não só as equipes de saúde e segurança do trabalho, mas também as instituições envolvidas em preservar a saúde dos trabalhadores, como a equipe do SESMET, sindicatos ou Ministério Público.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To identify the prevalence of hearing loss for the population in the urban area. METHODS: A cross-sectional household survey based on the World Health Organization Ear and Hearing Disorders Survey Protocol was conducted in 298 households in the urban area of Monte Negro, Rondonia, Northern Brazil, from 2005 to 2007. Ear examinations, behavioral audiometry and pure tone audiometry were conducted on 577 individuals. RESULTS: The results showed that 3.8% (95%CI 2.17;5.45) of population were classifi ed in the disabling hearing impairment category. The prevalence of moderate hearing impairment was 3.4%; severe impairment was 0.4%; and profound hearing impairment was not found. CONCLUSIONS: The impairing hearing loss prevalence found in this study is within of the international prevalence for this level of hearing loss and smaller than observed in a previous study in the South region of Brazil.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Severe Ménière's disease (MD) may be debilitating and compromising, despite intensive medical treatment. Vestibular neurectomy (VN) is considered an effective surgical treatment for disabling MD. Our aim was to analyse the medium- to long-term outcome after retrosigmoid VN with special regard to vertigo, quality of life (American Academy of Otolaryngology-Head and Neck Surgery criteria), and pure tone average (PTA).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A set of algorithms, which allows a computer to determine the answers of simulated patients during pure tone and speech audiometry, is presented. Based on these algorithms, a computer program for training in audiometry was written and found to be useful for teaching purposes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The comprehensive Hearing Preservation classification system presented in this paper is suitable for use for all cochlear implant users with measurable pre-operative residual hearing. If adopted as a universal reporting standard, as it was designed to be, it should prove highly beneficial by enabling future studies to quickly and easily compare the results of previous studies and meta-analyze their data. Objectives: To develop a comprehensive Hearing Preservation classification system suitable for use for all cochlear implant users with measurable pre-operative residual hearing. Methods: The HEARRING group discussed and reviewed a number of different propositions of a HP classification systems and reviewed critical appraisals to develop a qualitative system in accordance with the prerequisites. Results: The Hearing Preservation Classification System proposed herein fulfills the following necessary criteria: 1) classification is independent from users' initial hearing, 2) it is appropriate for all cochlear implant users with measurable pre-operative residual hearing, 3) it covers the whole range of pure tone average from 0 to 120 dB; 4) it is easy to use and easy to understand.