976 resultados para Pulmonary Emphysema Multislice CT Data


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The signal-to-noise ratio achievable in x-ray computed tomography (CT) images of polymer gels can be increased by averaging over multiple scans of each sample. However, repeated scanning delivers a small additional dose to the gel which may compromise the accuracy of the dose measurement. In this study, a NIPAM-based polymer gel was irradiated and then CT scanned 25 times, with the resulting data used to derive an averaged image and a "zero-scan" image of the gel. Comparison between these two results and the first scan of the gel showed that the averaged and zero-scan images provided better contrast, higher contrast-to- noise and higher signal-to-noise than the initial scan. The pixel values (Hounsfield units, HU) in the averaged image were not noticeably elevated, compared to the zero-scan result and the gradients used in the linear extrapolation of the zero-scan images were small and symmetrically distributed around zero. These results indicate that the averaged image was not artificially lightened by the small, additional dose delivered during CT scanning. This work demonstrates the broader usefulness of the zero-scan method as a means to verify the dosimetric accuracy of gel images derived from averaged x-ray CT data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The introduction of functional data into the radiotherapy treatment planning process is currently the focus of significant commercial, technical, scientific and clinical development. The potential of such data from positron emission tomography (PET) was recognized at an early stage and was integrated into the radiotherapy treatment planning process through the use of image fusion software. The combination of PET and CT in a single system (PET/CT) to form an inherently fused anatomical and functional dataset has provided an imaging modality which could be used as the prime tool in the delineation of tumour volumes and the preparation of patient treatment plans, especially when integrated with virtual simulation. PET imaging typically using F-Fluorodeoxyglucose (F-FDG) can provide data on metabolically active tumour volumes. These functional data have the potential to modify treatment volumes and to guide treatment delivery to cells with particular metabolic characteristics. This paper reviews the current status of the integration of PET and PET/CT data into the radiotherapy treatment process. Consideration is given to the requirements of PET/CT data acquisition with reference to patient positioning aids and the limitations imposed by the PET/CT system. It also reviews the approaches being taken to the definition of functional/ tumour volumes and the mechanisms available to measure and include physiological motion into the imaging process. The use of PET data must be based upon a clear understanding of the interpretation and limitations of the functional signal. Protocols for the implementation of this development remain to be defined, and outcomes data based upon clinical trials are still awaited. © 2006 The British Institute of Radiology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Positron emission tomography (PET)/CT scans can improve target definition in radiotherapy for non-small cell lung cancer (NSCLC). As staging PET/CT scans are increasingly available, we evaluated different methods for co-registration of staging PET/CT data to radiotherapy simulation (RTP) scans.<br/><br/>Methods: 10 patients underwent staging PET/CT followed by RTP PET/CT. On both scans, gross tumour volumes (GTVs) were delineated using CT (GTVCT) and PET display settings. Four PET-based contours (manual delineation, two threshold methods and a source-to-background ratio method) were delineated. The CT component of the staging scan was co-registered using both rigid and deformable techniques to the CT component of RTP PET/CT. Subsequently rigid registration and deformation warps were used to transfer PET and CT contours from the staging scan to the RTP scan. Diceâs similarity coefficient (DSC) was used to assess the registration accuracy of staging-based GTVs following both registration methods with the GTVs delineated on the RTP PET/CT scan.<br/><br/>Results: When the GTVCT delineated on the staging scan after both rigid registration and deformation was compared with the GTVCT on the RTP scan, a significant improvement in overlap (registration) using deformation was observed (mean DSC 0.66 for rigid registration and 0.82 for deformable registration, p50.008). A similar comparison for PET contours revealed no significant improvement in overlap with the use of deformable registration.<br/><br/>Conclusions: No consistent improvements in similarity measures were observed when deformable registration was used for transferring PET-based contours from a staging PET/CT. This suggests that currently the use of rigid registration remains the most appropriate method for RTP in NSCLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2015

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lung transplantation has evolved from an experimental procedure to a viable therapeutic option in many countries. In Switzerland, the first lung transplant was performed in November 1992, more than ten years after the first successful procedure world-wide. Thenceforward, a prospective national lung transplant registry was established, principally to enable quality control. The data of all patients transplanted in the two Swiss Lung Transplant centres Zurich University Hospital and Centre de Romandie (Geneva-Lausanne) were analysed. In 10 years 242 lung transplants have been performed. Underlying lung diseases were cystic fibrosis including bronchiectasis (32%), emphysema (32%), parenchymal disorders (19%), pulmonary hypertension (11%) and lymphangioleiomyomatosis (3%). There were only 3% redo procedures. The 1, 5 and 9 year survival rates were 77% (95% CI 72-82), 64% (95% CI 57-71) and 56% (95% CI 45-67), respectively. The 5 year survival rate of patients transplanted since 1998 was 72% (95% CI 64-80). Multivariate Cox regression analysis revealed that survival was significantly better in this group compared to those transplanted before 1998 (HR 0.44, 0.26-0.75). Patients aged 60 years and older (HR 5.67, 95% CI 2.50-12.89) and those with pulmonary hypertension (HR 2.01, 95% CI 1.10-3.65) had a significantly worse prognosis The most frequent causes of death were infections (29%), bronchiolitis obliterans syndrome (25%) and multiple organ failure (14%). The 10-year Swiss experience of lung transplantation compares favourably with the international data. The best results are obtained in cystic fibrosis, pulmonary emphysema and parenchymal disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nitric oxide synthase (NOS) inhibitors are largely used to evaluate the NO contribution to pulmonary allergy, but contrasting data have been reported. In this study, pharmacological, biochemical and pharmacokinetic assays were performed to compare the effects of acute and long-term treatment of BALB/C mice with the non-selective NOS inhibitor L-NAME in ovalbumin (OVA)-challenged mice. Acute L-NAME treatment (50 mg/kg, gavage) significantly reduced the eosinophil number in bronchoalveolar lavage fluid (BALF). The inducible NOS (iNOS) inhibitor aminoguanidine (20 mg/kg/day in the drinking water) also significantly reduced the eosinophil number in BALF In contrast, 3-week L-NAME treatment (50 and 150 mg/kg/day in the drinking water) significantly increased the pulmonary eosinophil influx. The constitutive NOS (cNOS) activity in brain and lungs was reduced by both acute and 3-week L-NAME treatments. The pulmonary iNOS activity was reduced by acute L-NAME (or aminoguanidine), but unaffected by 3-week L-NAME treatment. Acute L-NAME (or aminoguanidine) treatment was more efficient to reduce the NO(x) levels compared with 3-week L-NAME treatment. The pharmacokinetic study revealed that L-NAME is not bioavailable when given orally. After acute L-NAME intake, serum concentrations of the metabolite N(omega)-nitro-L-arginine decreased from 30 min to 24 h. In the 3-week L-NAME treatment, the N(omega)-nitro-L-arginine concentration was close to the detection limit. In conclusion, 3-week treatment with L-NAME yields low serum N(omega)-nitro-L-arginine concentrations, causing preferential inhibition of cNOS activity. Therefore, eosinophil influx potentiation by 3-week L-NAME treatment may reflect removal of protective cNOS-derived NO, with no interference on the ongoing inflammation due to iNOS-derived NO. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Chronic obstructive pulmonary disease is a major inflammatory disease of the airways and an enormous therapeutic challenge. Within the spectrum of chronic obstructive pulmonary disease, pulmonary emphysema is characterized by the destruction of the alveolar walls with an increase in the air spaces distal to the terminal bronchioles but without significant pulmonary fibrosis. Therapeutic options are limited and palliative since they are unable to promote morphological and functional regeneration of the alveolar tissue. In this context, new therapeutic approaches, such as cell therapy with adult stem cells, are being evaluated.OBJECTIVE This article aims to describe the follow-up of up to 3 years after the beginning of a phase I clinical trial and discuss the spirometry parameters achieved by patients with advanced pulmonary emphysema treated with bone marrow mononuclear cells.METHODS Four patients with advanced pulmonary emphysema were submitted to autologous infusion of bone marrow mononuclear cells. Follow-ups were performed by spirometry up to 3 years after the procedure.RESULTS The results showed that autologous cell therapy in patients having chronic obstructive pulmonary disease is a safe procedure and free of adverse effects. There was an improvement in laboratory parameters (spirometry) and a slowing down in the process of pathological degeneration. Also, patients reported improvements in the clinical condition and quality of life.CONCLUSIONS Despite being in the initial stage and in spite of the small sample, the results of the clinical protocol of cell therapy in advanced pulmonary emphysema as proposed in this study, open new therapeutic perspectives in chronic obstructive pulmonary disease. It is worth emphasizing that this study corresponds to the first study in the literature that reports a change in the natural history of pulmonary emphysema after the use of cell therapy with a pool of bone marrow mononuclear cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The problem of diagnosing whether a solitary pulmonary nodule is benign or malignant is even greater in developing countries due to a higher prevalence of infectious diseases. These infections generate a large number of patients who are generally asymptomatic and with a pulmonary nodule that cannot be accurately defined as having benign or malignant etiology.Purpose: To verify the percentages of benign versus malignant non-calcified nodules, the length of time after contrast agent injection is spiral computed tomography (CT) most sensitive and specific, and whether three postcontrast phases are necessary.Material and Methods: We studied 23 patients with solitary pulmonary nodules identified on chest radiographs or CT. Spiral scans were obtained with Swensen protocol, but at 3, 4, and 5 min after contrast injection onset. Nodules were classified as benign or malignant by histopathological examination or by an absence or presence of growth after 2 years of follow-up CT.Results: Of the 23 patients studied, 18 (78.2%) showed a final diagnosis of benign and five (21.7%) malignant nodules. Despite the small sample size, we obtained results similar to those of Swensen et al., with 80.0% sensitivity, 55.5% specificity, and 60.8% accuracy. Four minutes gave the greatest mean enhancement in both malignant and benign lesions.Conclusion: Small non-calcified benign nodules were much more frequent than malignant nodules. The best time for dynamic contrast-enhanced CT density analysis was 4 min postcontrast. As well as saving time and money, this simplified Swensen protocol with only precontrast and 4 min postcontrast phases also reduces patient exposure to ionizing radiation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The pulmonary rehabilitation (PR) is composed of aerobic and resisted exercises that improve the functional capacity to the exercise, life quality and decrease respiratory symptoms in subjects with chronic pulmonary disease. Objective: Assess the effects of a combined PR program in the cardiorespiratory function and peripheral muscle strength in subjects with chronic pulmonary disease. Method: Patients with chronic pulmonary disease were submitted to the PR program, which was developed on 24 sessions of 60 minutes (three times per week). The program was composed of aerobic exercises (two times per week) and resisted exercises (once a week). Before and after the PR the patients were submitted to manovacuometry in order to measure the maximum inspiratory pressure (MIP) and the maximum expiratory pressure (MEP), ventilometry, peek expiratory flow (PEF), six minute walking test (6MWT) and one maximum repetition (1RM). The data are presented in absolute frequency, percentage and mean±standard deviation. The t Student test was used to compare data before and after the PR and the ANOVA test to compare before, after and predicted distances in the 6MWT (p<0.05). Results: Seven patients were part of this study, 85.70% of women, 71.40% with pulmonary emphysema diagnosis. The mean age was 69.43±5.59 years old, the height was 1.61±0.07 m, the mean weight was 66.20±8.40 kg and the body mass index mean was 25.50±2.48 kg/m². From the variables assessed, the MEP increased from 79.71±13.69 to 84.42±12.83 cmH2O (p=0,03), the PEF increase from 255.71±66.3 to 320.00±93.63 l/min (p=0,03) and the distance in the 6MWT from 415.28±47.90 to 483,79±79,77 m (p=0,02). The load in the 1RM test in the reverse peck deck exercise (before - - 17.10±8.10kg; after â 210.40±9.00kg), knee in leg extension machine (before â 17.10±9.50kg; after â 26.40±13.10kg) and hip extensors (right before â 48.60±22.10kg; after â 62.90±19.30kg; and left before â 46.40±20.10kg; after â 62.10±18.20kg) increased significantly (p<0,05). Conclusion: After the PR program there was improvement in the expiratory muscular strength, in the lower limbs strength and in the functional capacity. Besides that, there was a reduction in the airflow obstruction of the subjects with chronic pulmonary disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Pulmonary fissures completeness predicts efficacy in endobronchial valves (EBV) implantation, a new lobar volume reduction therapy for severe emphysematous patients. We assessed the incidence of incomplete fissures and the interobserver agreement in its evaluation with MDCT, in severe emphysematous patients prior to EBV implantation. Materials and Methods: Volumetric thin-section CT scans of 35 patients (CODP GOLD 3/4, heterogeneous emphysema) were retrospectively reviewed by 2 pneumologists, 1 general and 2 experienced chest radiologists, independently and blinded for treatment outcome, and the pulmonary fissures were classified as either complete or incomplete. Interobserver agreement was assessed with Kappa index (KI). Results: Agreement between all readers for the left oblique, right oblique and horizontal fissure was, respectively, moderate (KI = 0.53), fair (KI = 0.37) and moderate (KI = 0.42). Highest agreement (99/105 fissures) was observed among experienced radiologists, being for left oblique, right oblique and horizontal, respectively, almost perfect (KI = 0.79), perfect (KI = 1.0) and moderate (KI = 0.52). These 2 reviewers found that all of 35 patients had at least one incomplete fissure, with a proportion of incomplete fissures assigned as 74/65%, 85/85% and 91/88%, respectively for the left oblique, right oblique and horizontal fissures. Conclusions: Pneumologists and radiologists agreed fairly to moderately in fissures analysis, while the experienced chest radiologists reached the highest clinically adequate agreement of 94%. We believe that clinical routine visual analysis of the fissures integrity can be done with a good degree of confidence in MDCT images, and experienced readers might be required. Also, a higher than expected incidence of incomplete fissures was described in our studied population. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the significance of multislice CT for the diagnosis of uncertain penetrating globe injuries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Protective patient equipment for CT examinations is not routinely provided. The aim of this study was to determine whether, and if so what, specific protective equipment is beneficial during CT scans. The absorbed organ doses and the effective doses for thorax, abdomen/pelvis and brain CT investigation with and without the use of protective patient equipment have been determined and compared. All measurements were carried out on modern multislice CT scanner using an anthropomorphic phantom and thermoluminescence dosemeters. The measurements show that protective equipment reduces the dose within the scattered beam area. The highest organ dose reduction was found in organs that protrude from the trunk like the testes or the female breasts that can largely be covered by the protective equipment. The most reduction of the effective dose was found in the male abdomen/pelvis examination (0.32 mSv), followed by the brain (0.11 mSv) and the thorax (0.06 mSv). It is concluded that the use of protective equipment can reduce the applied dose to the patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement of fluid volumes in cases of pericardial effusion is a necessary procedure during autopsy. With the increased use of virtual autopsy methods in forensics, the need for a quick volume measurement method on computed tomography (CT) data arises, especially since methods such as CT angiography can potentially alter the fluid content in the pericardium. We retrospectively selected 15 cases with hemopericardium, which underwent post-mortem imaging and autopsy. Based on CT data, the pericardial blood volume was estimated using segmentation techniques and downsampling of CT datasets. Additionally, a variety of measures (distances, areas and 3D approximations of the effusion) were examined to find a quick and easy way of estimating the effusion volume. Segmentation of CT images as shown in the present study is a feasible method to measure the pericardial fluid amount accurately. Downsampling of a dataset significantly increases the speed of segmentation without losing too much accuracy. Some of the other methods examined might be used to quickly estimate the severity of the effusion volumes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Aim of this study was to compare the utility of susceptibility weighted imaging (SWI) with the established diagnostic techniques CT and fluid attenuated inversion recovery (FLAIR) in their detecting capacity of subarachnoid hemorrhage (SAH), and further to compare the combined SWI/FLAIR MRI data with CT to evaluate whether MRI is more accurate than CT. METHODS: Twenty-five patients with acute SAH underwent CT and MRI within 6 days after symptom onset. Underlying pathology for SAH was head trauma (n=9), ruptured aneurysm (n=6), ruptured arteriovenous malformation (n=2), and spontaneous bleeding (n=8). SWI, FLAIR, and CT data were analyzed. The anatomical distribution of SAH was subdivided into 8 subarachnoid regions with three peripheral cisterns (frontal-parietal, temporal-occipital, sylvian), two central cisterns and spaces (interhemispheric, intraventricular), and the perimesencephalic, posterior fossa, superior cerebellar cisterns. RESULTS: SAH was detected in a total of 146 subarachnoid regions. CT identified 110 (75.3%), FLAIR 127 (87%), and SWI 129 (88.4%) involved regions. Combined FLAIR and SWI identified all 146 detectable regions (100%). FLAIR was sensitive for frontal-parietal, temporal-occipital and Sylvian cistern SAH, while SWI was particularly sensitive for interhemispheric and intraventricular hemorrhage. CONCLUSIONS: By combining SWI and FLAIR, MRI yields a distinctly higher detection rate for SAH than CT alone, particularly due to their complementary detection characteristics in different anatomical regions. Detection strength of SWI is high in central areas, whereas FLAIR shows a better detection rate in peripheral areas.