887 resultados para Prosthesis Evaluation Questionnaire
Resumo:
Bone-anchored prostheses are increasingly acknowledged as viable alternative method of attachment of artificial limb compared to socket-suspended prostheses. To date, a few osseointegration fixations are commercially available. Several devices are at different stages of development particularly in Europe and the US. Clearly, the current momentum experienced worldwide is creating a need for a standardized evaluation framework to assess the benefits and safety of each procedure.
Resumo:
Objective: To review the psychometric performance of the Child Health Questionnaire (CHQ) in samples ofchildren with cerebral palsy (CP).
Method: Four search terms were applied to five databases in a search forpapers published between 1993 and January 2007.
Results: A total of 13 papers were identified, providingdata on 1229 unique children aged 2–18 years old. Three studies reported on the reliability of the CHQ(internal consistency), whilst six studies provided evidence on various dimensions of validity (concurrent;discriminant and item discriminant validity).
Conclusions: This review identified a number ofpsychometric issues that need to be addressed. These include the assessment of additional types of reliability;an examination of the factor structure of the CHQ within the CP population; and the development ofnormative data using substantial representative samples, particularly in Europe. Until these issues areaddressed, researchers utilizing the CHQ in children with CP should be cautious about its interpretation.
Resumo:
This research provides new insights into the measurement of students’ authorial identity and its potential for minimising the incidence of unintentional plagiarism by providing evidence about the psychometric properties of the Student Authorship Questionnaire (SAQ). Exploratory and confirmatory factor analyses (EFA and CFA) are employed to investigate the measurement properties of the scales which comprise the SAQ using data collected from accounting students. The results provide limited psychometric support in favour of the factorial structure of the SAQ and raise a number of questions regarding the instrument’s robustness and generalisability across disciplines. An alternative model derived from the EFA outperforms the SAQ model with regard to its psychometric properties. Explanations for these findings are proffered and avenues for future research suggested.
Resumo:
Resumen tomado de la publicaci??n
Resumo:
This paper discusses self-esteem and hearing impaired children based on the results of a questionnaire administered to students at CID.
Resumo:
Os achados clínicos e radiográficos após reparo intra-articular do ligamento cruzado cranial com prótese de poliéster, utilizando a técnica over-the-top modificada, foram avaliada em seis cães. Sete cirurgias foram realizadas devido ao acometimento bilateral em um dos animais. A avaliação clínica foi realizada ao 3º, 10º e 40º dias de pós-operatório, e a avaliação radiográfica realizada ao 5º e 24º meses após a cirurgia em cinco cães, por meio da qual se confirmou a progressão da doença articular degenerativa. A resolução dos sinais clínicos foi observada entre o 25º e 68º dias após a cirurgia, segundo avaliação realizada pelos proprietários. A função do membro operado foi considerada boa. Dois cães apresentaram desgaste e ruptura da prótese após a cirurgia. Concluiu-se que a prótese de poliéster, da forma como foi implantada neste estudo, não pode ser considerada como substituto satisfatório, uma vez que resultados superiores podem ser obtidos com ténicas menos invasivas e mais simples.
Resumo:
Purpose: The aim of this study was to evaluate the satisfaction of patients rehabilitated with zygomatic fixtures and prosthesis with immediate loading.Materials and Methods: The study selected patients who were rehabilitated with zygomatic implants at the clinic of the Latin American Institute for Dental Research and Education (ILAPEO. Curitiba-PR. Brasil) between 2005 and 2009. The patients were asked to answer a control-questionnaire during their follow-up visits. Data were collected regarding the level of patient satisfaction, reason for dissatisfaction, number of post-operative clinical sessions, and the type of complication. Sixteen patients were selected: 10 females and 6 males.Results: Half of the patients were completely satisfied while the other half were satisfied with some complaints. The complaints were related to hygiene, esthetics, phonetics, and discomfort during chewing. Regarding the post-operative evaluation, 50% of the patients were attended due to the prosthesis (62.5%) and the implant (37.5%).Conclusions: The treatment with zygomatic fixtures is predictable and reliable. The patients were satisfied both with implants and prosthesis. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70: 314-319, 2012
Resumo:
The failure of facial prostheses is caused by limitations in the properties of existing materials, especially flexibility and durability. Therefore, this study evaluated the Shore A hardness of silicone used for fabrication of facial prostheses, Silastic MDX4-4210, according to the influence of storage period, daily disinfection, and 2 types of pigmentation. Thirty specimens were fabricated and divided in 3 groups: colorless, pigmented with makeup, and pigmented with iron oxide. Analysis of results was assessed on a Shore A hardness meter immediately, 6 months, and 1 year after fabrication of specimens, following the guidelines of the American Society for Testing and Materials. The hardness values were statistically analyzed by the Tukey test. The silicone exhibited an increase in hardness with time. However, the hardness was stable from 6 months to 1 year. It was concluded that the silicone is within the values of Shore A hardness reported in the literature, regardless of the storage period, pigmentation, and chemical disinfection.
Resumo:
Prosthetic substructures for dental application are veneered by porcelain comprising a structure with different elastic modulus and thermal expansion coefficients layers. This structure may present residual stresses in different layers leading to crack propagation and delamination. Although veneering porcelain remains basically on same strength than standard feldspathic porcelains, new ceramic cores have been developed with higher mechanical properties overcoming metal substructures, improving esthetics and biocompatibility. The interface between the Procera dense sintered alumina core and the manufacturer recommended veneering porcelain (AllCeram-Degussa) were evaluated using SEM in coping shaped specimen simulating the standard dental preparation. There were neither crack presences at the interface nor porcelain delamination.
Resumo:
The purpose of this article was to compare the mean value of optical density of four porcelains commonly used for fabrication of inlay/ onlay prostheses using direct digital radiograph. The sample consisted of 20 2-mm thick porcelain specimens (measured by digital pachymeter): Empress (Ivoclair), Simbios (Degussa), Vita Omega 900 and Vitadur Alpha (Vita Zahnfabrik). The values of optical density of the specimens were expressed in millimeters aluminum equivalent (mm eq Al). The samples were X-rayed using two charge coupled devices (CCD) - RVG (Trophy) - Visualix (Gendex) and a phosphor plate system - Digora (Soredex). The optical density reading was performed with Image Tool 1.28 in a total of 110 measurements. Statistical analysis showed that there were statistically significant differences in all materials studied (p < 0.05) regardless of the radiographic system used. The highest optical density value was found for Omega 900 (1.8988 mmeqAl - Visualix - Gendex) and the lowest for Vitadur Alpha (0.8647 - Visualix - Gendex). Thus, the material presenting the highest degree of optical density was Omega 900, Empress and Simbios presented intermediate optical density values, Vitadur Alpha presented the lowest value, and the optical density of porcelains was not influenced by the digital radiography systems.
Resumo:
Purpose: This study compared the biomechanical behavior of tilted long implant and vertical short implants to support fixed prosthesis in an atrophic maxilla. Materials and Methods: The maxilla model was built based on a tomographic image of the patient. Implant models were based on micro-computer tomography imaging of implants. The different configurations considered were M4S, four vertical anterior implants; M4T, two mesial vertical implants and two distal tilted (45°) implants in the anterior region of the maxilla; and M6S, four vertical anterior implants and two vertical posterior implants. Numerical simulation was carried out under bilateral 150N loads applied in the cantilever region in axial (L1) and oblique (45°) (L2) direction. Bone was analyzed using the maximum and minimum principal stress (σmax and σmin), and von Mises stress (σvM) assessments. Implants were analyzed using the σvM. Results: The higher σmax was observed at: M4T, followed by M6S/L1, M6S/L2, M4S/L2, and M4S/L1 and the higher σvM: M4T/L1, M4T/L2 and M4S/L2, M6S/L2, M4S/L1, and M6S/L1. Conclusions: The presence of distal tilted (all-on-four) and distal short implants (all-on-six) resulted in higher stresses in both situations in the maxillary bone in comparison to the presence of vertical implants (all-on-four). © 2013 Wiley Periodicals, Inc.
Resumo:
Purpose: Few reports have evaluated cumulative survival rates of extraoral rehabilitation and peri-implant soft tissue reaction at long-term follow-up. The objective of this study was to evaluate implant and prosthesis survival rates and the soft tissue reactions around the extraoral implants used to support craniofacial prostheses. Materials and Methods: A retrospective study was performed of patients who received implants for craniofacial rehabilitation from 2003 to 2010. Two outcome variables were considered: implant and prosthetic success. The following predictor variables were recorded: gender, age, implant placement location, number and size of implants, irradiation status in the treated field, date of prosthesis delivery, soft tissue response, and date of last follow-up. A statistical model was used to estimate survival rates and associated confidence intervals. We randomly selected 1 implant per patient for analysis. Data were analyzed using the Kaplan-Meier method and log-rank test to compare survival curves. Results: A total of 150 titanium implants were placed in 56 patients. The 2-year overall implant survival rates were 94.1% for auricular implants, 90.9% for nasal implants, 100% for orbital implants, and 100% for complex midfacial implants (P = .585). The implant survival rates were 100% for implants placed in irradiated patients and 94.4% for those placed in nonirradiated patients (P = .324). The 2-year overall prosthesis survival rates were 100% for auricular implants, 90.0% for nasal implants, 92.3% for orbital implants, and 100% for complex midfacial implants (P = .363). The evaluation of the peri-implant soft tissue response showed that 15 patients (26.7%) had a grade 0 soft tissue reaction, 30 (53.5%) had grade 1, 6 (10.7%) had grade 2, and 5 (8.9%) had grade 3. Conclusions: From this study, it was concluded that craniofacial rehabilitation with extraoral implants is a safe, reliable, and predictable method to restore the patient's normal appearance. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:1551-1557, 2012