BACKGROUND: Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent.

OBJECTIVES: To assess the effects of protocolized weaning from mechanical ventilation on the total duration of mechanical ventilation for critically ill adults; ascertain differences between protocolized and non-protocolized weaning in terms of mortality, adverse events, quality of life, weaning duration, intensive care unit (ICU) and hospital length of stay (LOS); and explore variation in outcomes by type of ICU, type of protocol and approach to delivering the protocol.

SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 1, 2010), MEDLINE (1950 to 2010), EMBASE (1988 to 2010), CINAHL (1937 to 2010), LILACS (1982 to 2010), ISI Web of Science and ISI Conference Proceedings (1970 to 2010), Cambridge Scientific Abstracts (inception to 2010) and reference lists of articles. We did not apply language restrictions.

SELECTION CRITERIA: We included randomized and quasi-randomized controlled trials of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults.

DATA COLLECTION AND ANALYSIS: Three authors independently assessed trial quality and extracted data. A priori subgroup and sensitivity analyses were performed. We contacted study authors for additional information.

MAIN RESULTS: Eleven trials that included 1971 patients met the inclusion criteria. The total duration of mechanical ventilation geometric mean in the protocolized weaning group was on average reduced by 25% compared with the usual care group (N = 10 trials, 95% CI 9% to 39%, P = 0.006); weaning duration was reduced by 78% (N = 6 trials, 95% CI 31% to 93%, P = 0.009); and ICU LOS by 10% (N = 8 trials, 95% CI 2% to 19%, P = 0.02). There was significant heterogeneity among studies for total duration of mechanical ventilation (I(2) = 76%, P <0.01) and weaning duration (I(2) = 97%, P <0.01), which could not be explained by subgroup analyses based on type of unit or type of approach.

AUTHORS' CONCLUSIONS: There is some evidence of a reduction in the duration of mechanical ventilation, weaning duration and ICU LOS with use of standardized protocols, but there is significant heterogeneity among studies and an insufficient number of studies to investigate the source of this heterogeneity. Although some study authors suggest that organizational context may influence outcomes, these factors were not considered in all included studies and therefore could not be evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background; Weaning from mechanical ventilation is influenced by patient, clinician, and organizational factors.

Objective: To identify factors that may influence weaning and adoption of weaning strategies and tools, clinicians’ perceptions of weaning strategies, and weaning experiences of patients and patients’ families.

Method: A scoping review of indexed and nonindexed publications (1990–2012) was done. Qualitative studies of health care providers, patients, and patients’ families involved in weaning were included. Two investigators independently screened 8350 publications and extracted data from 43 studies. Study themes were content analyzed to identify common categories and themes within the categories.

Results: The study sample consisted of nurses in 15 studies, nurses and patients in 1 study, various health care providers in 11, patients in 10, and physicians in 4. Categories identified were as follows: for nurses, role or scope of practice, informing decision making, and influence on weaning outcome; for health care providers, factors influencing weaning decisions or use of protocols, role or scope of practice related to weaning, and organizational structure or practice environment; for patients, experience of mechanical ventilation and weaning, experience of the intensive care environment, psychological phenomena, and enabling success in weaning; and for physicians, tools or factors to facilitate weaning decisions and perceptions of nurses’ role and scope of practice.

Conclusions: Important issues identified were perceived importance of interprofessional collaboration and communication, need to combine subjective knowledge of the patient with objective clinical data, balancing of weaning systematization with individual needs, and appreciation of the physical and psychological work of weaning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This is an update of a review last published in Issue 5, 2010, of The Cochrane Library. Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent. Objectives: The first objective of this review was to compare the total duration of mechanical ventilation of critically ill adults who were weaned using protocols versus usual (non-protocolized) practice.The second objective was to ascertain differences between protocolized and non-protocolized weaning in outcomes measuring weaning duration, harm (adverse events) and resource use (intensive care unit (ICU) and hospital length of stay, cost).The third objective was to explore, using subgroup analyses, variations in outcomes by type of ICU, type of protocol and approach to delivering the protocol (professional-led or computer-driven). Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2014), MEDLINE (1950 to January 2014), EMBASE (1988 to January 2014), CINAHL (1937 to January 2014), LILACS (1982 to January 2014), ISI Web of Science and ISI Conference Proceedings (1970 to February 2014), and reference lists of articles. We did not apply language restrictions. The original search was performed in January 2010 and updated in January 2014.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-RCTs of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults. Data collection and analysis: Two authors independently assessed trial quality and extracted data. We performed a priori subgroup and sensitivity analyses. We contacted study authors for additional information. Main results: We included 17 trials (with 2434 patients) in this updated review. The original review included 11 trials. The total geometric mean duration of mechanical ventilation in the protocolized weaning group was on average reduced by 26% compared with the usual care group (N = 14 trials, 95% confidence interval (CI) 13% to 37%, P = 0.0002). Reductions were most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. Weaning duration was reduced by 70% (N = 8 trials, 95% CI 27% to 88%, P = 0.009); and ICU length of stay by 11% (N = 9 trials, 95% CI 3% to 19%, P = 0.01). There was significant heterogeneity among studies for total duration of mechanical ventilation (I2 = 67%, P < 0.0001) and weaning duration (I2 = 97%, P < 0.00001), which could not be explained by subgroup analyses based on type of unit or type of approach. Authors' conclusions: There is evidence of reduced duration of mechanical ventilation, weaning duration and ICU length of stay with use of standardized weaning protocols. Reductions are most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. However, significant heterogeneity among studies indicates caution in generalizing results. Some study authors suggest that organizational context may influence outcomes, however these factors were not considered in all included studies and could not be evaluated. Future trials should consider an evaluation of the process of intervention delivery to distinguish between intervention and implementation effects. There is an important need for further development and research in the neurosurgical population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background
Mechanical ventilation is a life-saving intervention for critically ill newborn infants with respiratory failure admitted to a neonatal intensive care unit (NICU). Ventilating newborn infants can be challenging due to small tidal volumes, high breathing frequencies, and the use of uncuffed endotracheal tubes. Mechanical ventilation has several short-term, as well as long-term complications. To prevent complications, weaning from the ventilator is started as soon as possible. Weaning aims to support the transfer from full mechanical ventilation support to spontaneous breathing activity.

Objectives
To assess the efficacy of protocolized versus non-protocolized ventilator weaning for newborn infants in reducing the duration of invasive mechanical ventilation, the duration of weaning, and shortening the NICU and hospital length of stay. To determine efficacy in predefined subgroups including: gestational age and birth weight; type of protocol; and type of protocol delivery. To establish whether protocolized weaning is safe and clinically effective in reducing the duration of mechanical ventilation without increasing the risk of adverse events.

Search methods
We searched the Cochrane Central Register of Controlled trials (CENTRAL; the Cochrane Library; 2015, Issue 7); MEDLINE In-Process and other Non-Indexed Citations and OVID MEDLINE (1950 to 31 July 2015); CINAHL (1982 to 31 July 2015); EMBASE (1988 to 31 July 2015); and Web of Science (1990 to 15 July 2015). We did not restrict language of publication. We contacted authors of studies with a subgroup of newborn infants in their study, and experts in the field regarding this subject. In addition, we searched abstracts from conference proceedings, theses, dissertations, and reference lists of all identified studies for further relevant studies.

Selection criteria
Randomized, quasi-randomized or cluster-randomized controlled trials that compared protocolized with non-protocolized ventilator weaning practices in newborn infants with a gestational age of 24 weeks or more, who were enrolled in the study before the postnatal age of 28 completed days after the expected date of birth.

Data collection and analysis
Four authors, in pairs, independently reviewed titles and abstracts identified by electronic searches. We retrieved full-text versions of potentially relevant studies.

Main results
Our search yielded 1752 records. We removed duplicates (1062) and irrelevant studies (843). We did not find any randomized, quasi-randomized or cluster-randomized controlled trials conducted on weaning from mechanical ventilation in newborn infants. Two randomized controlled trials met the inclusion criteria on type of study and type of intervention, but only included a proportion of newborns. The study authors could not provide data needed for subgroup analysis; we excluded both studies.

Authors' conclusions
Based on the results of this review, there is no evidence to support or refute the superiority or inferiority of weaning by protocol over non-protocol weaning on duration of invasive mechanical ventilation in newborn infants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of mechanical ventilation (MV) of high-oxygen concentration in pulmonary dysfunction in adult and elderly rats. Methods: Twenty-eight adult (A) and elderly (E), male rats were ventilated for 1 hour (G-AV1 and G-EV1) or for 3 hours (G-AV3 and G-EV3). A and E groups received a tidal volume of 7 mL/kg, a positive end-expiratory pressure of 5 cm H2O, respiratory rate of 70 cycles per minute, and an inspiratory fraction of oxygen of 1. We evaluated total protein content and malondialdehyde in bronchoalveolar lavages (BAL) and performed lung histomorphometrical analyses. Results: In G-EV1 animals, total protein in BAL was higher (33.0 +/- 1.9 mu g/mL) compared with G-AV1 (23.0 +/- 2.0 mu g/mL). Upon 180 minutes of MV, malondialdehyde levels increased in elderly (G-EV3) compared with adult (G-AV3) groups. Malondialdehyde and total proteins in BAL after 3 hours of MV were higher in elderly group than in adults. In G-EV3 group we observed alveolar septa dilatation and significative increase in neutrofiles number in relation to adult group at 60 and 180 minutes on MV. Conclusion: A higher fraction of inspired oxygen in short courses of mechanical ventilation ameliorates the parameters studied in elderly lungs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Prognostic factors are used in the Intensive Care Unit (ICU) to predict morbidity and mortality , especially in patients on mechanical ventilation (MV ) . Training protocols are used in MV patients with the aim of promoting the success of the weaning process. Objective: To assess which variables determine the outcome of patients undergoing mechanical ventilation and compare the effects of two protocols for weaning. Method: Patients under MV for more than 48 hours had collected the following information: sex, age , ideal weight, height , Acute Physiology and Chronic Health Evaluation (APACHE II), risk of mortality, Glasgow Coma Scale (GCS) and index Quick and perfunctory (IRRS) breathing. Patients with unsuccessful weaning performed one of weaning protocols: Progressive T - tube or tube - T + Threshold ® IMT. Patients were compared for outcome (death or non- death in the ICU ) and the protocols through the t test or Mann-Whitney test was considered significant when P <0.05. Results: Of 128 patients evaluated 56.25% were men, the mean age was 60.05 ± 17.85 years and 40.62 % patients died, and they had higher APACHE II scores, mortality risk, time VM and IRRS GCS and the lower value (p<0.05). The age, initial and final maximal inspiratory pressure, time of weaning and duration of MV was similar between protocols. Conclusion: The study suggests that the GCS, APACHE II risk of mortality, length of MV and IRRS variables determined the evolution of MV patients in this sample. Not found differences in the variables studied when comparing the two methods of weaning.