824 resultados para Print reading
Resumo:
'Risk Criticism: Reading in an Age of Manufactured Uncertainties' is a study of literary and cultural responses to global environmental risk that offers an environmental humanities approach to understanding risk in an age of unfolding ecological catastrophe. In 2015, the Bulletin of the Atomic Scientists re-set its iconic Doomsday Clock to three minutes to midnight, as close to the apocalypse as it has been since 1953. What pushed its hands was, however, not just the threat of nuclear weapons, but also other global environmental risks that the Bulletin judged to have risen to the scale of the nuclear, including climate change and innovations in the life sciences. If we may once have believed that the end of days would come in a blaze of nuclear firestorm (or the chill of the subsequent nuclear winter), we now suspect that the apocalypse may be much slower, creeping in as chemical toxin, climate change, or bio- or nano- technologies run amok. Taking inspiration from the questions raised by the Bulletin’s synecdochical “nuclear,” 'Risk Criticism' aims to generate a hybrid form of critical practice that brings “nuclear criticism”—a subfield of literary studies that has been, since the Cold War, largely neglected—into conversation with ecocriticism, the more recent approach to environmental texts in literary studies. Through readings of novels, films, theater, poetry, visual art, websites, news reports, and essays, 'Risk Criticism' tracks the diverse ways in which environmental risks are understood and represented today.
Resumo:
Mode of access: Internet.
Resumo:
Reproduction of original from Harvard Law School Library.
Resumo:
Background. Both self-help print materials and telephone-assisted counseling have generally proved useful strategies to increase physical activity. This study examined their effectiveness in an intervention aimed specifically at promoting walking for specific purposes. Methods. Participants (n = 399) were randomly allocated to one of two 3-week intervention programs. The Print program comprised multiple mailing of brochures that emphasized walking within the local community environments. The Print plus Telephone program received the same brochures plus three telephone calls. Data collected via mailed self-completed surveys were analyzed by exploring outcomes related to walking for specific purposes. Results. There were no significant differences between the two programs in any of the walking measures. Both groups significantly increased time reported walking for exercise per week [Print: t(1,277) = -3.50, P < 0.001; Print plus telephone: t(1,106) = -2.44, P < 0.016]. Significantly, more participants in the Print plus Telephone group reported receiving and reading the materials (chi(2) = 20.11, P < 0.0001). Conclusions. The intervention programs were more successful at increasing walking for exercise than for any other purpose. The addition of brief telephone support was successful in focusing participants' attention on the print materials, but did not result in any additional increase in walking. (C) 2004 The Institute For Cancer Prevention and Elsevier Inc. All rights reserved.
Resumo:
A correlational study was designed to examine the general processing speed and orthographic processing speed accounts of the association between continuous naming speed and word reading skill in children from fourth to sixth grade. Children were given two tests of each of the following constructs: word reading skill, alphanumeric symbol naming speed, nonsymbol naming speed, alphanumeric processing speed, and nonsymbol processing speed. Results were not completely consistent with either the general processing speed or the orthographic processing speed accounts. Although an alphanumeric symbol processing efficiency component is clearly involved, it is argued that the particularly strong association between naming speed and word reading also reflects the efficiency of phonological processing in children of this age.
Resumo:
One hundred and twelve university students completed 7 tests assessing word-reading accuracy, print exposure, phonological sensitivity, phonological coding and knowledge of English morphology as predictors of spelling accuracy. Together the tests accounted for 71% of the variance in spelling, with phonological skills and morphological knowledge emerging as strong predictors of spelling accuracy for words with both regular and irregular sound-spelling correspondences. The pattern of relationships was consistent with a model in which, as a function of the learning opportunities that are provided by reading experience, phonological skills promote the learning of individual word orthographies and structural relationships among words.
Resumo:
PURPOSE: To provide a consistent standard for the evaluation of different types of presbyopic correction. SETTING: Eye Clinic, School of Life and Health Sciences, Aston University, Birmingham, United Kingdom. METHODS: Presbyopic corrections examined were accommodating intraocular lenses (IOLs), simultaneous multifocal and monovision contact lenses, and varifocal spectacles. Binocular near visual acuity measured with different optotypes (uppercase letters, lowercase letters, and words) and reading metrics assessed with the Minnesota Near Reading chart (reading acuity, critical print size [CPS], CPS reading speed) were intercorrelated (Pearson product moment correlations) and assessed for concordance (intraclass correlation coefficients [ICC]) and agreement (Bland-Altman analysis) for indication of clinical usefulness. RESULTS: Nineteen accommodating IOL cases, 40 simultaneous contact lens cases, and 38 varifocal spectacle cases were evaluated. Other than CPS reading speed, all near visual acuity and reading metrics correlated well with each other (r>0.70, P<.001). Near visual acuity measured with uppercase letters was highly concordant (ICC, 0.78) and in close agreement with lowercase letters (+/- 0.17 logMAR). Near word acuity agreed well with reading acuity (+/- 0.16 logMAR), which in turn agreed well with near visual acuity measured with uppercase letters 0.16 logMAR). Concordance (ICC, 0.18 to 0.46) and agreement (+/- 0.24 to 0.30 logMAR) of CPS with the other near metrics was moderate. CONCLUSION: Measurement of near visual ability in presbyopia should be standardized to include assessment of near visual acuity with logMAR uppercase-letter optotypes, smallest logMAR print size that maintains maximum reading speed (CPS), and reading speed. J Cataract Refract Surg 2009; 35:1401-1409 (C) 2009 ASCRS and ESCRS
Resumo:
The purpose of this study was to determine if there was an objective difference in reading between four commonly available lamps, of varying spectral radiance, for 13 subjects with age-related maculopathy (ARM) or non-exudative age-related macular degeneration (AMD) - logMAR visual acuity between 0.04 and 0.68. At a constant illuminance of 2000 lux, there was no interaction between ARM and AMD subgroups and no statistically significant difference between the lamps: standard (clear envelope) incandescent, daylight simulation (blue tint envelope) incandescent, compact fluorescent and halogen incandescent, for any reading outcome measure (threshold print size p = 0.67, critical print size p = 0.74, acuity reserve p = 0.84 and mean reading rate p = 0.78). For lamps typically used in low-vision rehabilitation, a clinically significant effect of spectral radiance on reading for people with ARM or non-exudative AMD is unlikely. © 2007 The College of Optometrists.
Resumo:
Purpose: To investigate the effects of light filters on reading speed in normal and low vision due to age-related macular degeneration (AMD). Methods: Reading speed was determined for 12 subjects with normal vision and 12 subjects with non-exudative AMD using stationary lowercase nonsensical print in Times Roman font and four light filters; a yellow Corning Photochromic Filter (CPF) 450, a grey neural density (ND) filter, an individual filter obtained using the Intuitive Colorimeter® and a clear filter. Results: There was no statistically significant light filter effect on reading speed for the normal subjects. The AMD group demonstrated a statistically significant 5% average improvement in reading speed with the CPF450 compared with the other filters although some AMD subjects had improvements of 10-15%. Conclusions: Light filters obtained using the Intuitive Colorimeter® performed poorly when compared with the CPF450, ND and clear filters for both the study groups. For the AMD group, average reading speed was statistically greater with the CPF450 than the other filters, however it is questionable whether the improvement (5%) would be clinically significant. As some of the subjects with AMD had greater improvements with the CPF450 we advocate clinical assessment of light filters using existing protocols on an individual basis. © 2004 The College of Optometrists.
Resumo:
Background: As light-emitting diodes become more common as the light source for low vision aids, the effect of illumination colour temperature on magnifier reading performance was investigated. Methods: Reading ability (maximum reading speed, critical print size, threshold near visual acuity) using Radner charts and subjective preference was assessed for 107 participants with visual impairment using three stand magnifiers with light emitting diode illumination colour temperatures of 2,700 K, 4,500 K and 6,000 K. The results were compared with distance visual acuity, prescribed magnification, age and the primary cause of visual impairment. Results: Reading speed, critical print size and near visual acuity were unaffected by illumination colour temperature (p > 0.05). Reading metrics decreased with worsening acuity and higher levels of prescribed magnification but acuity was unaffected by age. Each colour temperature was preferred and disliked by a similar number of patients and was unrelated to distance visual acuity, prescribed magnification and age (p > 0.05). Patients had better near acuity (p = 0.002), critical print size (p = 0.034) and maximum reading speed (p <0.001), and the improvement in near from distance acuity was greater (p = 0.004) with their preferred rather than least-liked colour temperature illumination. Conclusion: A range of colour temperature illuminations should be offered to all visually impaired individuals prescribed with an optical magnifier for near tasks to optimise subjective and objective benefits.
Resumo:
The essential first step for a beginning reader is to learn to match printed forms to phonological representations. For a new word, this is an effortful process where each grapheme must be translated individually (serial decoding). The role of phonological awareness in developing a decoding strategy is well known. We examined whether beginner readers recruit different skills depending on the nature of the words being read (familiar words vs. nonwords). Print knowledge, phoneme and rhyme awareness, rapid automatized naming (RAN), phonological short term memory (STM), nonverbal reasoning, vocabulary, auditory skills and visual attention were measured in 392 pre-readers aged 4 to 5 years. Word and nonword reading were measured 9 months later. We used structural equation modeling to examine the skills-reading relationship and modeled correlations between our two reading outcomes and among all pre-reading skills. We found that a broad range of skills were associated with reading outcomes: early print knowledge, phonological STM, phoneme awareness and RAN. Whereas all these skills were directly predictive of nonword reading, early print knowledge was the only direct predictor of word reading. Our findings suggest that beginner readers draw most heavily on their existing print knowledge to read familiar words.
Resumo:
Abstract: Loss of central vision caused by age-related macular degeneration (AMD) is a problem affecting increasingly large numbers of people within the ageing population. AMD is the leading cause of blindness in the developed world, with estimates of over 600,000 people affected in the UK . Central vision loss can be devastating for the sufferer, with vision loss impacting on the ability to carry out daily activities. In particular, inability to read is linked to higher rates of depression in AMD sufferers compared to age-matched controls. Methods to improve reading ability in the presence of central vision loss will help maintain independence and quality of life for those affected. Various attempts to improve reading with central vision loss have been made. Most textual manipulations, including font size, have led to only modest gains in reading speed. Previous experimental work and theoretical arguments on spatial integrative properties of the peripheral retina suggest that ‘visual crowding’ may be a major factor contributing to inefficient reading. Crowding refers to the phenomena in which juxtaposed targets viewed eccentrically may be difficult to identify. Manipulating text spacing of reading material may be a simple method that reduces crowding and benefits reading ability in macular disease patients. In this thesis the effect of textual manipulation on reading speed was investigated, firstly for normally sighted observers using eccentric viewing, and secondly for observers with central vision loss. Test stimuli mimicked normal reading conditions by using whole sentences that required normal saccadic eye movements and observer comprehension. Preliminary measures on normally-sighted observers (n = 2) used forced-choice procedures in conjunction with the method of constant stimuli. Psychometric functions relating the proportion of correct responses to exposure time were determined for text size, font type (Lucida Sans and Times New Roman) and text spacing, with threshold exposure time (75% correct responses) used as a measure of reading performance. The results of these initial measures were used to derive an appropriate search space, in terms of text spacing, for assessing reading performance in AMD patients. The main clinical measures were completed on a group of macular disease sufferers (n=24). Firstly, high and low contrast reading acuity and critical print size were measured using modified MNREAD test charts, and secondly, the effect of word and line spacing was investigated using a new test, designed specifically for this study, called the Equal Readability Passages (ERP) test. The results from normally-sighted observers were in close agreement with those from the group of macular disease sufferers. Results show that: (i) optimum reading performance was achieved when using both double line and double word spacing; (ii) the effect of line spacing was greater than the effect of word spacing (iii) a text size of approximately 0.85o is sufficiently large for reading at 5o eccentricity. In conclusion, the results suggest that crowding is detrimental to reading with peripheral vision, and its effects can be minimized with a modest increase in text spacing.
Resumo:
Aim: To validate the accuracy and repeatability of a mobile app reading speed test compared with the traditional paper version. Method: Twenty-one subjects wearing their full refractive correction glasses read 14 sentences of decreasing print size between 1.0 and -0.1 logMAR, each consisting of 14 words (Radner reading speed test) at 40 cm with a paper-based chart and twice on iPad charts. Time duration was recorded with a stop watch for the paper chart and on the App itself for the mobile chart allowing critical print size (CPS) and optimal reading speed (ORS) to be derived objectively. Results: The ORS was higher for the mobile app charts (194±29 wpm; 195±25 wpm) compared with the paper chart (166±20 wpm; F=57.000, p<0.001). The CPS was lower for the mobile app charts (0.17±0.20 logMAR; 0.18±0.17 logMAR) compared with the paper chart (0.25±0.17 logMAR; F=5.406, p=0.009). The mobile app test had a mean difference repeatability of 0.30±22.5 wpm, r=0.917 for ORS, and a CPS of 0.0±0.2 logMAR, r=0.769. Conclusions: Repeatability of the app reading speed test is as good (ORS) or better (CPS) than previous studies on the paper test. While the results are not interchangeable with paper-based charts, mobile app tablet-based tests of reading speed are reliable and rapid to perform, with the potential to capture functional visual ability in research studies and clinical practice.
Resumo:
The purpose of this study is to investigate the effects of bilingual and monolingual videos on the reading comprehension of students with significant hearing impairments and/or deafness. Children with and without hearing losses need reading programs in which comprehension of meaning is the primary goal. This can occur only when print is represented in meaningful context, allowing children to create meaning from their own experience, background, and knowledge of language.^ Investigated in this study was whether students with significant hearing losses comprehended more information in a bilingual or monolingual instructional video format. There were three instructional videos produced: (a) the bilingual video which incorporated American Sign Language (ASL) with standard English captions, (b) a monolingual English video with standard English captions only, and (c) a monolingual ASL-only video. It was hypothesized that the effects of English captioning with ASL might serve as a bridge during instruction, increasing reading comprehension and written English for students. It was further hypothesized that this would allow students to integrate their own ASL knowledge to the printed text to construct meaning.^ Four separate analyses were conducted to see if the hypothesis was supported by the findings. However, all results indicated that there were no significant differences in students' written measures of reading comprehension recall across any of the three presentations of information (two monolingual and one bilingual condition). There were seven variables (word identification, word recall, sentence recall, story recall, written passage theme, written passage word count, and number of mature words) used to evaluate reading comprehension recall. No variable, either individually or grouped, demonstrated a significant difference between monolingual or bilingual instruction. ^