986 resultados para Plaster casts


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the influence of plaster condition, dry or not, on the amount of residual monomer in heat-cured acrylic resin. Methods: Thirty acrylic resin specimens (65×10×3 mm) were fabricated and randomly assigned to 5 groups (n=6). The evaluated resins were heat-cured acrylic resins by conventional or microwave polymerization techniques and the plaster was previously dried in microwave oven in two groups. Each specimen was individually immersed in a test tube containing methanol (7 days) for surface analysis. In the groups for which internal monomer was evaluated, the specimens were fragmented and the small fragments were weighed prior to immersion in methanol. The analysis was made by high performance liquid chromatography (HPLC). Data were analyzed by ANOVA and Tukey test (p<5%) Results: showed statistical differences among the groups. Conclusions: The previous plaster drying influenced the residual monomer amount showing a decrease of these levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital models are an alternative for carrying out analyses and devising treatment plans in orthodontics. The objective of this study was to evaluate the accuracy and the reproducibility of measurements of tooth sizes, interdental distances and analyses of occlusion using plaster models and their digital images. Thirty pairs of plaster models were chosen at random, and the digital images of each plaster model were obtained using a laser scanner (3Shape R-700, 3Shape A/S). With the plaster models, the measurements were taken using a caliper (Mitutoyo Digimatic(®), Mitutoyo (UK) Ltd) and the MicroScribe (MS) 3DX (Immersion, San Jose, Calif). For the digital images, the measurement tools used were those from the O3d software (Widialabs, Brazil). The data obtained were compared statistically using the Dahlberg formula, analysis of variance and the Tukey test (p < 0.05). The majority of the measurements, obtained using the caliper and O3d were identical, and both were significantly different from those obtained using the MS. Intra-examiner agreement was lowest when using the MS. The results demonstrated that the accuracy and reproducibility of the tooth measurements and analyses from the plaster models using the caliper and from the digital models using O3d software were identical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cares at the manipulation of the alginate (condensation, disinfection of the impression and the time elapsed until the leak of the plaster) deserve special attention considering the great amount of distortions occurring every time the impression is not fill of plaster in a brief space of time and appropriate storage conditions. Besides its adaptation to the plaster suffers influence of the events happened after the impression is removed of the mouth. The purpose of this research was to evaluate the wetting capacity of three brands of alginate (Jeltrate™,Hydrogum™ e Orthoprint™) by the plaster type III (Rio™) under the influence of disinfection by sodium hypochlorite 1% sprays and the time of storage of 15 minutes,30 minutes, 1 hour, 6, 12 and 24 hours. There were made 60 impressions of each brand of alginate divided in two groups (water and sodium hypochlorite 1%) rearranged after the application of the sodium hypochlorite spray according to the storage time (15 or 30 minutes and 1,6,12, or 24 hours). On the surface of the impressions 2ml of plaster were flowed, proportioned and condensed in agreement with manufacturer‘s instructions. After the final setting expansion the casts were sectioned vertically and medially, regularized at the cut surface (emery paper 400) and setted for reading the contact angle at the microscope Carl Zeiss. The obtained results, submitted to statistical treatment (ANOVA) revealed significant differences when compared the employed solutions (water and sodium hypochlorite 1%) and the time of storage. The sodium hypochlorite 1% exhibited the smallest contact angles and the times of storage of 15 minutes and 6 hours the smallest and larger angles, respectively. It can be concluded that the alginate impressions exhibited larger adaptation to the plaster when disinfected by hypochlorite of sodium 1% and stocked by 15 minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature contains many case reports of planned and complex suicides, which combine various methods to commit suicide. In this article, we present the anomalous suicide of an adult male by strangulation with a belt and simultaneous ingestion of plaster. The specific circumstances of the case are described and relevant literature is briefly reviewed. This case vignette illustrates one example of the wide ranging methods employed in suicides and may represent the first reported case of a fatal complex suicide involving self-strangulation and plaster ingestion. Knowledge of varied and sometimes unusual suicide methods is important to the forensic investigator to prevent unnecessary criminal investigation and to reliably and confidently establish manner and cause of death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corticosteroids are a versatile option for the treatment of mild-to-moderate psoriasis due to their availability in a wide range of potencies and formulations. Occlusion of the corticosteroid is a widely accepted procedure to enhance the penetration of the medication, thereby improving its effectiveness. Betamethasone valerate (BMV) is a moderately potent corticosteroid that is available as a cream, ointment, and lotion. A ready-to-use occlusive dressing, which provides a continuous sustained release of BMV, has been developed for the treatment of psoriasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: The aim of this study was to assess the marginal fit of crowns on the Straumann (ITI) Dental Implant System with special consideration of different casting dental materials. MATERIAL AND METHODS: Sixty porcelain-fused-to-metal crowns were fabricated: 18 crowns on standard cone abutments with an impression cylinder, partially prefabricated analogs, no coping and screw-retained (A); 18 crowns on solid abutments without an impression device, no analogs, no coping and cemented (B); and 18 crowns on solid abutments using an impression transfer cap, an analog with a shoulder, no coping and cemented (C). In each group, six crowns were made on epoxy mastercasts (Bluestar), six on synthetic plaster (Moldasynt) and six on super hard stone (Fujirock). Six additional crowns were fabricated with the transversal screw retention system onto the Octa system with impression transfer caps, metal analogs, gold copings and screw-retained (D). Impregum was used as impression material. Crowns of B and C were cemented with KetacCem. Crowns of A and D were fixed with an occlusal screw torqued at 15 N cm. Crowns were embedded, cut and polished. Under a light microscope using a magnification of x 100, the distance between the crown margin (CM) and the shoulder (marginal gap, MG) and the distance between the CM and the end of the shoulder (crown length, CL) was measured. RESULTS: MGs were 15.4+/-13.2 microm (A), 21.2+/-23.1 microm (B), 11+/-12.1 microm (C) and 10.4+/-9.3 microm (D). No statistically significantly differences using either of the casting materials were observed. CLs were -21.3+/-24.8 microm (A), 3+/-28.9 microm (B), 0.5+/-22 microm (C) and 0.1+/-15.8 microm (D). Crowns were shorter on synthetic casting materials compared with stone casts (P<0.005). CONCLUSIONS: CMs fit precisely with both cemented and screw-retained versions as well as when using no, partial or full analogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare standard plaster models with their digital counterparts for the applicability of the Index of Complexity, Outcome, and Need (ICON). Generated study models of 30 randomly selected patients: 30 pre- (T(0)) and 30 post- (T(1)) treatment. Two examiners, calibrated in the ICON, scored the digital and plaster models. The overall ICON scores were evaluated for reliability and reproducibility using kappa statistics and reliability coefficients. The values for reliability of the total and weighted ICON scores were generally high for the T(0) sample (range 0.83-0.95) but less high for the T(1) sample (range 0.55-0.85). Differences in total ICON score between plaster and digital models resulted in mostly statistically insignificant values (P values ranging from 0.07 to 0.19), except for observer 1 in the T(1) sample. No statistically different values were found for the total ICON score on either plaster or digital models. ICON scores performed on computer-based models appear to be as accurate and reliable as ICON scores on plaster models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY A recent systematic review demonstrated that, overall, orthodontic treatment might result in a small worsening of periodontal status. The aim of this retrospective study was to test the hypothesis that a change of mandibular incisor inclination promotes development of labial gingival recessions. One hundred and seventy-nine subjects who met the following inclusion criteria were selected: age 11-14 years at start of orthodontic treatment (TS), bonded retainer placed immediately after treatment (T₀), dental casts and lateral cephalograms available pre-treatment (TS), post-treatment (T₀), 2 years post-treatment (T₂), and 5 years post-treatment (T₅). Depending on the change of lower incisor inclination during treatment (ΔInc_Incl), the sample was divided into three groups: Retro (N = 34; ΔInc_Incl ≤ -1 degree), Stable (N = 22; ΔInc_Incl > -1 degree and ≤1 degree), and Pro (N = 123; ΔInc_Incl > 1 degree). Clinical crown heights of mandibular incisors and the presence of gingival recessions in this region were assessed on plaster models. Fisher's exact tests, one-way analysis of variance, and regression models were used for analysis of inter-group differences. The mean increase of clinical crown heights (T₀ to T₅) of mandibular incisors ranged from 0.6 to 0.91 mm in the Retro, Stable, and Pro groups, respectively; the difference was not significant (P = 0.534). At T₅, gingival recessions were present in 8.8, 4.5, and 16.3 per cent patients from the Retro, Stable, and Pro groups, respectively. The difference was not significant (P = 0.265). The change of lower incisors inclination during treatment did not affect development of labial gingival recessions in this patient group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The aim of this study was to determine the reproducibility and accuracy of linear measurements on 2 types of dental models derived from cone-beam computed tomography (CBCT) scans: CBCT images, and Anatomodels (InVivoDental, San Jose, Calif); these were compared with digital models generated from dental impressions (Digimodels; Orthoproof, Nieuwegein, The Netherlands). The Digimodels were used as the reference standard. METHODS The 3 types of digital models were made from 10 subjects. Four examiners repeated 37 linear tooth and arch measurements 10 times. Paired t tests and the intraclass correlation coefficient were performed to determine the reproducibility and accuracy of the measurements. RESULTS The CBCT images showed significantly smaller intraclass correlation coefficient values and larger duplicate measurement errors compared with the corresponding values for Digimodels and Anatomodels. The average difference between measurements on CBCT images and Digimodels ranged from -0.4 to 1.65 mm, with limits of agreement values up to 1.3 mm for crown-width measurements. The average difference between Anatomodels and Digimodels ranged from -0.42 to 0.84 mm with limits of agreement values up to 1.65 mm. CONCLUSIONS Statistically significant differences between measurements on Digimodels and Anatomodels, and between Digimodels and CBCT images, were found. Although the mean differences might be clinically acceptable, the random errors were relatively large compared with corresponding measurements reported in the literature for both Anatomodels and CBCT images, and might be clinically important. Therefore, with the CBCT settings used in this study, measurements made directly on CBCT images and Anatomodels are not as accurate as measurements on Digimodels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION A prerequisite for development of gingival recession is the presence of alveolar bone dehiscence. Proclination of mandibular incisors can result in thinning of the alveolus and dehiscence formation. OBJECTIVE To assess an association between proclination of mandibular incisor and development of gingival recession. METHODS One hundred and seventeen subjects who met the following inclusion criteria were selected: 1. age 11-14 years at start of orthodontic treatment (TS), 2. bonded retainer placed immediately after treatment (T0), 3. dental casts and lateral cephalograms available pre-treatment (TS), post-treatment (T0), and 5 years post-treatment (T5), and 4. post-treatment (T0) lower incisor inclination (Inc_Incl) <95° or >100.5°. Two groups were formed: non-proclined (N = 57; mean Inc_Incl = 90.8°) and proclined (N = 60; mean Inc_Incl = 105.2°). Clinical crown heights of mandibular incisors and the presence of gingival recession sites in this region were assessed on plaster models. Fisher's exact tests, t-tests, and regression models were computed for analysis of inter-group differences. RESULTS The mean increase of clinical crown heights (from T0 to T5) of mandibular incisors ranged from 0.75 to 0.83mm in the non-proclined and proclined groups, respectively (P = 0.273). At T5, gingival recession sites were present in 12.3% and 11.7% patients from the non-proclined and proclined groups, respectively. The difference was also not significant (P = 0.851). CONCLUSIONS The proclination of mandibular incisors did not increase a risk of development of gingival recession during five-year observation in comparison non-proclined teeth.