989 resultados para Plasma-volume


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The in vitro growth of erythroid colonies in the absence of erythropoietin, known as endogenous erythroid colonies (EEC) forms part of the diagnostic criteria for polycythaemia vera (PV). The availability of EEC culture in routine laboratory setting is limited as culture methods are technically demanding, difficult to standardize, expensive and laborious. In this study, we assessed the performance characteristics of a simplified method using ammonium chloride red cell lysis followed by culture on commercially available, batch-tested, methylcellulose media. Seventy-six patients were included; four were secondarily excluded on the basis of culture failure. Of the 14 patients with PV, 13 (93%) were positive for EEC on at least one occasion: 90% (nine of 10) of bone marrow and 67% (six of nine) of peripheral blood specimens were positive. All 30 patients with secondary polycythaemia (n = 12) or apparent polycythaemia (n = 18) were negative for EEC. The incidence of EEC in idiopathic erythrocytosis was 40% (eight of 28); 50% (five of 10) in those who met one of the minor criteria for PV and 17% (three of 18) in those who did not. We conclude that our EEC assay yield results comparable with that of more elaborate methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The impact of acute weight loss on rowing performance was assessed when generous nutrient intake was provided in 2 h of recovery after making weight. Methods: Competitive rowers (N = 17) completed four ergometer trials, each separated by 48 h. Two trials were performed after a 4% body mass loss in the previous 24 h (WT) and two were performed after no weight restrictions, that is, unrestricted (UNR). In addition, two trials (I X WT, I X UNR) were in a thermoneutral environment (NEUTRAL, mean 21.1 +/- SD 0.7 degrees C, 29.0 +/- 4.5% RH) and two were in the heat (HOT 32.4, +/- 0.4 degrees C, 60.4 +/- 2.7% RH). Trials were performed in a counterbalanced fashion according to a Latin square design. Aggressive nutritional recovery strategies (WT 2.3 g(.)kg(-11) carbohydrate, 34 mg-kg(-1) Na, 28.4 mL(.)kg(-1) fluid; UNR ad libitum) were employed in the 2 h after weigh-in. Results: Both WT (mean 2.1, 95% CI 0.7-3.4 s; P = 0.003) and HOT (4.1, 2.7 - 5.4 s; P < 0.001) compromised 2000-m time-trial performance. Whereas WT resulted in hypohydration, the associated reduction in plasma volume explained only part of the performance compromise observed (0.2 s for every 1% decrement) Moreover, WT did not influence core temperature or indices of cardiovascular function. Conclusions: Acute weight loss compromised performance, despite generous nutrient intake in recovery, although the effect was small. Performance decrements were further exacerbated when exercise was performed in the heat.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: To assess the influence of moderate, acute weight loss on on-water rowing performance when aggressive nutritional recovery strategies were used in the two hours between weigh in and racing. Methods: Competitive rowers (n=17) undertook three on-water 1800 m time trials under cool conditions ( mean (SD) temperature 8.4 (2.0)degrees C), each separated by 48 hours. No weight limit was imposed for the first time trial-that is, unrestricted body mass (UNR1). However, one of the remaining two trials followed a 4% loss in body mass in the previous 24 hours (WT-4%). No weight limit was imposed for the other trial (UNR2). Aggressive nutritional recovery strategies (WT-4%, 2.3 g/kg carbohydrate, 34 mg/kg Na+, and 28.4 ml/kg fluid; UNR, ad libitum) were used in the first 90 minutes of the two hours between weigh in and performance trials. Results: WT-4% had only a small and statistically non-significant effect on the on-water time trial performance ( mean 1.0 second, 95% confidence interval (CI) 20.9 to 2.8; p=0.29) compared with UNR. This was despite a significant decrease in plasma volume at the time of weigh in for WT-4% compared with UNR (-9.2%, 95% CI -12.8% to -5.6%; p

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The advantages of using cryopreserved semen in equine reproduction are well known. During cryopreservationl spermatozoa undergo many changes that lead to a decrease in fertility. There is no agreement on the ideal sperm dose and concentration to maximize fertility rates. Thus, the objectives of this experiment were to evaluate sperm motion by computer-assisted analysis (CASA), sperm membrane integrity and function with fluorescence probes of cryopreserved sperm at three concentrations: 100 (C100), 200 (C200) and 400 x 10(6) sperm/mL (C400), and two straw volumes (0.50 and 0.25 mL). There was no interaction between sperm concentration and storage volume (P > .05). Sperm motion characteristics were influenced by concentration (C100 > C200 > C400; P < .05). Curvilinear velocity (VCL) in 0.25-mL straws had higher average values (P < .05). Membrane integrity and function were not changed by straw volume (P > .05). However, sperm concentration changed the percentage of cells with intact plasma membrane (C100 > C200 > C400; P < .05) and the percentage of cells with high mitochondrial membrane potential (C100 = C200; P > .05 and C400 < C100 and C200; P < .05). According to this experiment, the best freeing method was that involving 100 x 10(6) sperm/mL, regardless of straw volume.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Changes in plasma zinc concentration and markers of immune function were examined in a group of 10 male runners (n = 10) following a moderate increase in training over four weeks. Seven sedentary males acted as controls. Fasting blood samples were taken at rest, before (T0) and after T4) four weeks of increased (+ 16 %) training and after two weeks of reduced (- 31 %) training (W. Blood was analysed for plasma zinc concentration, differential leucocyte counts, lymphocyte subpopulations and lymphocyte proliferation using incorporation of H-3-thymidine. The runners increased their training volume by 16 % over the four weeks. When compared with the nonathletes, the runners had lower concentrations of plasma zinc (p = 0.012), CD3(+) (p = 0.042) and CD19(+) lymphocytes (p = 0.010) over the four weeks. Lymphocyte proliferation in response to Concanavalin A stimulation was greater in the runners (p = 0.0090). Plasma zinc concentration and immune markers remained constant during the study. Plasma zinc concentration correlated with total leucocyte counts in the athletes at T6 (r = -0.72, p < 0.05) and with Pokeweed mitogen stimulation in the nonathletes at T6 (r = -0.92, p < 0.05). Therefore, athletes are unlikely to benefit from zinc supplementation during periods of moderately increased training volume.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We hypothesized that acute volume expansion by saline infusion triggers the release of endothelin-1. Bolus intravenous saline infusion (8 mL/min) in six groups of conscious Wistar rats and spontaneously hypertensive rats did not change mean arterial pressure or heart rate (n = 8 to 12). At 1 min after infusion, the plasma endothelin-1 level was significantly increased in Wistar rats and in spontaneously hypertensive rats by 42% and 61%, respectively (unpaired data). In 12 Wistar rats, the endothelin-1 level increased from 0.68 +/- 0.13 to 1.19 +/- 0.17 fmol/mL (mean +/- SEM, P <.0001, paired data). Thus, acute volume load by rapid saline infusion increases plasma endothelin-1 levels. Vasoconstriction induced by endothelin-1 may counteract enhanced circumferential stretch created by volume expansion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The existence of a circadian rhythm of atrial natriuretic peptide (ANP) in humans is controversial. We studied the plasma ANP response to isotonic blood volume expansion in the morning and in the afternoon and its relationship with adrenocorticotropic hormone (ACTH)-cortisol diurnal variation in seven normal subjects. Basal plasma ANP level was similar in the morning (19.6 ± 2.4 pg/ml) and in the afternoon (21.8 ± 4.8 pg/ml). The ANP peak obtained with saline infusion (0.9% NaCl, 12 ml/kg) in the morning (49.4 ± 8 pg/ml) did not differ from that obtained in the afternoon (60.3 ± 10.1 pg/ml). There was no correlation between the individual mean cortisol and ACTH levels and the ANP peak obtained with saline infusion. These data indicate no diurnal variation in plasma ANP secretion induced by blood volume expansion and no relationship between plasma ANP peak and ACTH-cortisol diurnal variation

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Plasma and tissue testosterone concentrations were determined by radioimmunoassay in 12 eight-month-old sexually mature New Zealand White rabbits and evaluated for possible associations with spermatogenic efficiency as well as with volume density and number of Leydig cells. Testicular tissue was processed histologically and histometry was performed in order to quantify germ cells, Sertoli cells and Leydig cells. Spermatogenic efficiency, reported as the ratios among germ cells (spermatogonia, primary spermatocytes and round spermatids) and by the ratio of germ cells to Sertoli cells, was not associated with testosterone levels. However, Leydig cell parameters such as number of Leydig cells per gram of testis, total number of Leydig cells per testis and percent cell volume of Leydig cell nuclei were correlated significantly with testosterone levels. The statistically significant correlation (r = 0.82, P<0.05) observed between testosterone levels and the number of Leydig cells per gram of testis suggests that, in the rabbit, the latter parameter can serve as a criterion for monitoring testosterone levels in this species under normal conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effect of dose and volume of a perimuscular injection of Bothrops jararacussu venom on myonecrosis of skeletal muscle was studied in mice. An increase of the venom dose (0.25 to 2.0 µg/g) at a given volume (50 µl) resulted in an increase in plasma creatine kinase (CK) levels 2 h after injection. Plasma CK activity increased from the basal level of 129.27 ± 11.83 (N = 20) to 2392.80 ± 709.43 IU/l (N = 4) for the 1.0 µg/g dose. Histological analysis of extensor digitorum longus muscle 4 h after injection showed lesion of peripheral muscle fibers, disorganization of the bundles or the complete degeneration of muscle fibers. These lesions were more extensive when higher doses were injected. Furthermore, an increase in volume (12.5 to 100 µl) by dilution of a given dose (0.5 µg/g) also increased plasma CK levels from 482.31 ± 122.79 to 919.07 ± 133.33 IU/l (N = 4), respectively. These results indicate that care should be taken to standardize volumes and sites of venom injections.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current data indicate that the size of high-density lipoprotein (HDL) may be considered an important marker for cardiovascular disease risk. We established reference values of mean HDL size and volume in an asymptomatic representative Brazilian population sample (n=590) and their associations with metabolic parameters by gender. Size and volume were determined in HDL isolated from plasma by polyethyleneglycol precipitation of apoB-containing lipoproteins and measured using the dynamic light scattering (DLS) technique. Although the gender and age distributions agreed with other studies, the mean HDL size reference value was slightly lower than in some other populations. Both HDL size and volume were influenced by gender and varied according to age. HDL size was associated with age and HDL-C (total population); non- white ethnicity and CETP inversely (females); HDL-C and PLTP mass (males). On the other hand, HDL volume was determined only by HDL-C (total population and in both genders) and by PLTP mass (males). The reference values for mean HDL size and volume using the DLS technique were established in an asymptomatic and representative Brazilian population sample, as well as their related metabolic factors. HDL-C was a major determinant of HDL size and volume, which were differently modulated in females and in males.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The effects of chronic aerobic exercise upon lipid profile has been previously demonstrated, but few studies showed this effect under resistance exercise conditions. Objective: The aim of this study was to examine the effects of different resistance exercise loads on blood lipids. Methods: Thirty healthy, untrained male volunteers were allocated randomly into four groups based at different percentages of one repetition maximum (1 RM); 50%-1 RM, 75%-1 RM, 90%-1 RM, and 110%-1 RM. The total volume (sets x reps x load) of the exercise was equalized. The lipid profile (Triglycerides [TG], HDL-cholesterol [HDL-c], LDL-cholesterol, and Total cholesterol) was determined at rest and after 1, 24, 48 and 72 h of resistance exercise. Results: The 75%-1 RM group demonstrated greater TG reduction when compared to other groups (p < 0.05). Additionally, the 110%-1 RM group presented an increased TG concentration when compared to 50% and 75% groups (p = 0.01, p = 0.01, respectively). HDL-c concentration was significantly greater after resistance exercise in 50%-1 RM and 75%-1 RM when compared to 110%-1 RM group (p = 0.004 and p = 0.03, respectively). Accordingly, the 50%-1 RM group had greater HDL-c concentration than 110%-1 RM group after 48 h (p = 0.05) and 72 h (p = 0.004), respectively. Finally, The 50% group has showed lesser LDL-c concentration than 110% group after 24 h (p = 0.007). No significant difference was found in Total Cholesterol concentrations. Conclusion: These results indicate that the acute resistance exercise may induce changes in lipid profile in a specific-intensity manner. Overall, low and moderate exercise intensities appear to be promoting more benefits on lipid profile than high intensity. Long term studies should confirm these findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A procedure for partial digestion of bovine tissue is proposed using polytetrafluoroethylene (PTFE) microvessels inside a baby-bottle sterilizer under microwave radiation for multi-element determination by inductively coupled plasma optical emission spectrometry (ICP OES). Samples were directly weighed in laboratory-made polytetrafluoroethylene vessels. Nitric acid and hydrogen peroxide were added to the uncovered vessels, which were positioned inside the baby-bottle sterilizer, containing 500 mL of water. The hydrogen peroxide volume was fixed at 100 mu L The system was placed in a domestic microwave oven and partial digestion was carried out for the determination of Ca, Cu, Fe. Mg, Mn and Zn by inductively coupled plasma optical emission spectrometry. The single-vessel approach was used in the entire procedure, to minimize contamination in trace analysis. Better recoveries and lower residual carbon content (RCC) levels were obtained under the conditions established through a 2(4-1) fractional factorial design: 650 W microwave power, 7 min digestion time, 50 mu L nitric acid and 50 mg sample mass. The digestion efficiency was ascertained according to the residual carbon content determined by inductively coupled plasma optical emission spectrometry. The accuracy of the proposed procedure was checked against two certified reference materials. (C) 2009 Elsevier B.V. All rights reserved.