971 resultados para Planar auto-calibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of computational fluid dynamics simulations for calibrating a flush air data system is described, In particular, the flush air data system of the HYFLEX hypersonic vehicle is used as a case study. The HYFLEX air data system consists of nine pressure ports located flush with the vehicle nose surface, connected to onboard pressure transducers, After appropriate processing, surface pressure measurements can he converted into useful air data parameters. The processing algorithm requires an accurate pressure model, which relates air data parameters to the measured pressures. In the past, such pressure models have been calibrated using combinations of flight data, ground-based experimental results, and numerical simulation. We perform a calibration of the HYFLEX flush air data system using computational fluid dynamics simulations exclusively, The simulations are used to build an empirical pressure model that accurately describes the HYFLEX nose pressure distribution ol cr a range of flight conditions. We believe that computational fluid dynamics provides a quick and inexpensive way to calibrate the air data system and is applicable to a broad range of flight conditions, When tested with HYFLEX flight data, the calibrated system is found to work well. It predicts vehicle angle of attack and angle of sideslip to accuracy levels that generally satisfy flight control requirements. Dynamic pressure is predicted to within the resolution of the onboard inertial measurement unit. We find that wind-tunnel experiments and flight data are not necessary to accurately calibrate the HYFLEX flush air data system for hypersonic flight.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acquisition of HI Parkes All Shy Survey (HIPASS) southern sky data commenced at the Australia Telescope National Facility's Parkes 64-m telescope in 1997 February, and was completed in 2000 March. HIPASS is the deepest HI survey yet of the sky south of declination +2 degrees, and is sensitive to emission out to 170 h(75)(-1) Mpc. The characteristic root mean square noise in the survey images is 13.3 mJy. This paper describes the survey observations, which comprise 23 020 eight-degree scans of 9-min duration, and details the techniques used to calibrate and image the data. The processing algorithms are successfully designed to be statistically robust to the presence of interference signals, and are particular to imaging point (or nearly point) sources. Specifically, a major improvement in image quality is obtained by designing a median-gridding algorithm which uses the median estimator in place of the mean estimator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The applicability of image calibration to like-values in mapping water quality parameters from multitemporal images is explored, Six sets of water samples were collected at satellite overpasses over Moreton Bay, Brisbane, Australia. Analysis of these samples reveals that waters in this shallow bay are mostly TSS-dominated, even though they are occasionally dominated by chlorophyll as well. Three of the images were calibrated to a reference image based on invariant targets. Predictive models constructed from the reference image were applied to estimating total suspended sediment (TSS) and Secchi depth from another image at a discrepancy of around 35 percent. Application of the predictive model for TSS concentration to another image acquired at a time of different water types resulted in a discrepancy of 152 percent. Therefore, image calibration to like-values could be used to reliably map certain water quality parameters from multitemporal TM images so long as the water type under study remains unchanged. This method is limited in that the mapped results could be rather inaccurate if the water type under study has changed considerably. Thus, the approach needs to be refined in shallow water from multitemporal satellite imagery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To attend and obtain the systems and. internal controls mechanisms proposed by Sarbanes-Oxley certifications is actually a big challenge,for most of the multinational companies registered in SEC (US Securities and Exchange Commission). This work has the objective of contributing to the analysis of this methodology, not only to attend the law but to reduce cost and generate value through the strengthen of the internal control systems, turning them into animating value generation process mechanisms. So, the idea is to identify the main gaps in the theory through the literature revision and a case study in order to put a question to the main deficiencies, strong points or contributions through the evaluation of the noticed practices. Finally, we can say that a a result of the research and the analyses made in. this case, the vast majority of executives and other employees recognize the benefit that Sarbanes-Oxley Act has brought to the company searched. Also recognize that, although there is still necessity for systemic adequacy and infrastructure, it helps and reinforce reducing and controlling the risks. the system of internal controls in all areas of expertise. They approach and understand that there is the need for a change in the other employees` culture to be inserted in the day-today routine as internal controls, attention to Sarbanes-Oxley and Corporate Governance, making the control cost smaller when compared to the benefits generated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phosphoniobate glasses with composition (mol%) (100-x) NaPO(3)-xNb(2)O(5) ( x varying from 11 to 33) were prepared and characterized by means of thermal analysis, Fourier transform infrared spectroscopy, Raman scattering and (31)P nuclear magnetic resonance. The addition of Nb(2)O(5) to the polyphosphate base glass leads to depolymerization of the metaphosphate structure. Different colors were observed and assigned as indicating the presence of Nb(4+) ions, as confirmed by electron paramagnetic resonance measurements. The color was observed to depend on the glass composition and melting temperature as well. Er(3+) containing samples were also prepared. Strong emission in the 1550 nm region was observed. The Er(3+4)I(15/2) emission quantum efficiency was observed to be 90% and the quenching concentration was observed to be 1.1 mol%( 1.45 x 10(20) ions cm(-3)). Planar waveguides were prepared by Na(+)-K(+)-Ag(+) ion exchange with Er(3+) containing samples. Optical parameters of the waveguides were measured at 632.8, 543.5 and 1550 nm by the prism coupling technique as a function of the ion exchange time and Ag(+) concentration. The optimized planar waveguides show a diffusion depth of 5.9 mu m and one propagating mode at 1550 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Er(3+) doped (100-x)SiO(2)-xZrO(2) planar waveguides were prepared by the sol-gel route, with x ranging from 10 up to 30 mol%. Multilayer films doped with 0.3 mol% Er(3+) ions were deposited on fused quartz substrates by the dip-coating technique. The thickness and refractive index were measured by m-line spectroscopy at different wavelengths. The fabrication protocol was optimized in order to confine one propagating mode at 1.5 mu m. Photoluminescence in the near and visible region indicated a crystalline local environment for the Er(3+) ion. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a new approach for designing planar gradient coils is outlined for the use in an existing MRI apparatus. A technique that allows for gradient field corrections inside the diameter-sensitive volume is deliberated. These corrections are brought about by making changes to the wire paths that constitute the coil windings, and hence, is called the path correction method. The existing well-known target held method is used to gauge the performance of a typical gradient coil. The gradient coil design methodology is demonstrated for planar openable gradient coils that can be inserted into an existing MRI apparatus. The path corrected gradient coil is compared to the coil obtained using the target field method. It is shown that using a wire path correction with optimized variables, winding patterns that can deliver high magnetic gradient field strengths and large imaging regions can be obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel flow-tagging technique is presented which was employed to measure gas velocities in the free stream of a shock tube. This method is based on the laser spectroscopic techniques of Laser-Enhanced Ionisation (LEI) and Laser-Induced Fluorescence (LIF). The flow in the shock tube is seeded with small amounts of sodium, and LEI is used to produce a substantial depletion of neutral sodium atom concentration in a well-defined region of the flow, by using two wavelength-resonance excitation and subsequent collisional ionisation. At a specific time delay, single-laser-pulse planar LIF is utilised to produce a two-dimensional (2-D) inverse image of the depleted tagged region downstream of the flow. By measuring the displacement of the tagged region, free stream velocities in a shock tube were determined. Large variations in the concentration of sodium seeded into the flow were observed and even in the presence of these large variations accurate free-stream velocity measurements were obtained. The experimentally determined value for velocity compares very well with the predicted velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Many questions remain unanswered about premature atherosclerosis in rheumatoid arthritis (RA). Besides inflammation, some studies have suggested the role of autoantibodies on its pathogenesis. Objective: The aim of this study was to investigate the presence of antibodies against phospholipids, beta2-glycoproteinl (beta2-gpl), lipoprotein lipase, and heat shock proteins (Hsp) in RA patients and to evaluate their possible association with subclinical carotid atherosclerosis. Methods: Seventy-one RA patients and 53 age- and sex-matched controls were selected to perform anticardiolipin antibodies (aCL) (IgG and IgM), anti-beta2-gpl (IgG, IgM, and IgA), anti-lipoprotein lipase (anti-LPL), anti-Hsp 60, and anti-Hsp 65 by ELISA tests. Intima-medial thickness (IMT) of common carotid and presence of plaques were assessed by high-resolution B-mode ultrasonography. Exclusion criteria were smoking, diabetes, and arterial hypertension. Lipoproteins, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and fibrinogen levels, as well as health assessment questionnaire (HAQ) and disease activity score (DAS) 28 were also evaluated. Results: Age (48.93 +/- 12.31 vs. 45.37 +/- 9.37 years; p = 0.20) and body mass index (BMI) (p = 0.69) were similar in RA and controls, as well as female gender (p = 0.56). The mean IMT was similar between RA and controls (0. 721 +/- 0.16 vs. 0.667 +/- 0.14 turn, p = 0.07) but the frequency of plaques was higher in RA (14.1% vs. 1.9%; p = 0.02). In RA patients, IMT measurements did not differ according to the presence or absence of these antibodies: IgG aCL (0.62 +/- 0.64 vs. 0.72 +/- 0.17 mm, p = 0.24), IgM aCL (0.65 +/- 0.79 vs. 0.73 +/- 0.17 mm, p = 0.33), anti-Hsp 60 (0.78 +/- 0.20 vs. 0.71 +/- 0.16 mm, p = 0.27), anti-Hsp 65 (0.73 +/- 0.16 vs. 0.72 +/- 0.17 mm, p = 0.77), IgG anti-beta2-gpl (0.73 +/- 0.16 vs. 0.71 +/- 0.17 mm, p = 0.72), and anti-CCP (0.71 +/- 0.16 vs. 0.76 +/- 0.20 mm, p = 0.36). In addition, IMT did not correlate with antibodies titers: IgG aCL (r = -0.09, p = 0.47), IgM aCL (r = - 0.15, p = 0.21), anti-Hsp 60 (r = 0.10, p = 0.42), anti-Hsp 65 (r = 0.05, p = 0.69), IgG anti-beta2-gpl (r = - 0.07, p = 0.57), IgM anti-beta2-gpl (r = - 0.05, p = 0.69), IgA anti-beta2-gpl (r = 0.03, p = 0.79), and anti-CCP (r = - 0.07, p = 0.57). RA patients with plaques had a significantly higher age compared to those without plaques (p = 0.001), as well as higher mean IMT (p < 0.001), total cholesterol (p = 0.001), and LDL (p = 0.003). Conclusions: In RA a clear association between all autoantibodies studied herein and increased IMT or presence of plaques was not observed. The great prevalence of carotid atherosclerosis in RA was related to age, total and LDL cholesterol, as identified in normal population. (c) 2008 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spatial and temporal evolution of a depleted atomic distribution created by laser enhanced ionisation (LEI) was employed to determine both a diffusion coefficient for sodium (Na) and an electron (e(-)) and sodium ion recombination rate coefficient in an analytical air-C2H2 flame. A depleted distribution of neutral sodium atoms was produced in a flame by ionising approximately 80% of the irradiated sodium atoms in a well defined region using a two step LEI excitation scheme. Following depletion by ionisation, planar laser induced fluorescence (PLIF) images of the depleted region recorded the diffusion and decay of the depleted Na distribution for different depletion-probe delays. From measurements of the diffused width of the distribution, an accurate diffusion coefficient D = (1.19 +/- 0.03) x 10(-3) m(2) s(-1) for Na was determined in teh burnt gases of the flame. Measurements of the integrated fluorescence intensity in the depleted region for different depletion-probe delays were related to an increase in atomic sodium concentration caused by electron-ion recombination. At high concentrations (greater than or equal to 50 mu g ml(-1)), where the electron and ion concentrations in the depleted region were assumed equal, a recombination rate coefficient of 4.2 x 10(-9) cm(3) s(-1) was calculated. (C) 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: