994 resultados para Piezoelectric charge constant


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a practical scheme for performing ab initio supercell calculations of charged slabs at constant electron chemical potential mu, rather than at constant number of electrons N-e. To this end, we define the chemical potential relative to a plane (or "reference electrode") at a finite distance from the slab (the distance should reflect the particular geometry of the situation being modeled). To avoid a net charge in the supercell, and thus make possible a standard supercell calculation, we restore the electroneutrality of the periodically repeated unit by means of a compensating charge, whose contribution to the total energy and potential is subtracted afterwards. The "constant mu" mode enables one to perform supercell calculation on slabs, where the slab is kept at a fixed potential relative to the reference electrode. We expect this to be useful in modeling many experimental situations, especially in electro-chemistry. (C) 2001 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dusty plasma crystalline configuration with equal charge dust grains and mass is considered. Both charge and mass of each dust species are taken to be constant. Two differential equations for a two-dimensional hexagonal crystal on the basis of a Yukawa-type potential energy and a

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whilst there are a number of methods available to characterise the cell surface hydrophobicity (CSH) and cell surface charge (CSC) of microorganisms, there is still debate concerning the correlation of results between individual methods. In this study, the techniques of bacterial adherence to hydrocarbons (BATH) and hydrophobic interaction chromatography (HTC) were used to measure CSH. Electrostatic interaction chromatography (ESIC) and zeta potential (ZP) measurements were used to determine CSC. To allow meaningful comparisons between the BATH and HIC tests, between ESIC and ZP and also between CSH and CSC, the buffer systems employed in each test were standardised (phosphate buffered saline, pH 7.3, 0.01 mM). Isolates of Staphylococcus epidermidis derived from microbial biofilm were used as the test organism in this study. The isolates examined exhibited primarily medium to high CSH and a highly negative CSC. Good correlation of CSH measurement was observed between the BATH and HIC tests (r = 0.89). Good correlation was observed between ESIC (anionic exchange column) and ZP measurements. No correlations were observed between isolate CSC and either increased or decreased CSH. It is recommended that whenever comparisons of various methods to determine either CSC or CSH (by partitioning methods), the buffer systems should remain constant throughout to achieve consistency of results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les effets cardiovasculaires des alpha-2 agonistes, particulièrement importants chez les chiens, limitent leur utilisation en pratique vétérinaire. La perfusion à débit constant (PDC) de ces drogues, comme la médétomidine (MED) permettrait un contrôle plus précis de ces effets. Les effets hémodynamiques de plusieurs doses de MED en PDC ont été évalués chez le chien. Lors de cette étude prospective, réalisée en double aveugle, 24 chiens en santé, ont reçu de façon aléatoire une des 6 doses de MED PDC (4 chiens par groupe). Les chiens ont été ventilés mécaniquement pendant une anesthésie minimale standardisée avec de l’isoflurane dans de l’oxygène. Une dose de charge (DC) de médétomidine a été administrée aux doses de 0.2, 0.5, 1.0, 1.7, 4.0 ou 12.0 µg/kg pendant 10 minutes, après laquelle la MED PDC a été injectée à une dose identique à celle de la DC pendant 60 minutes. L’isoflurane a été administré seul pendant une heure après l’administration d’une combinaison d’ISO et de MED PDC pendant 70 minutes. La fréquence cardiaque (FC), la pression artérielle moyenne (PAM) et l’index du débit cardiaque (IC) ont été mesurés. Des prélèvements sanguins ont permis d’évaluer le profil pharmacocinétique. D’après ces études, les effets hémodynamiques de la MED PDC pendant une anesthésie à l’isoflurane ont été doses-dépendants. L’IC a diminué progressivement alors que la dose de MED augmentait avec: 14.9 (12.7), 21.7 (17.9), 27.1 (13.2), 44.2 (9.7), 47.9 (8.1), and 61.2 (14.1) % respectivement. Les quatre doses les plus basses n’ont provoqué que des changements minimes et transitoires de la FC, de la PAM et de l’IC. La pharmacocinétique apparaît clairement dose-dépendante. De nouvelles expériences seront nécessaires afin d’étudier l’utilisation clinique de la MED PDC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En démontrant sa capacité d’identifier les pneumothorax, de différencier les différentes causes d’insuffisance respiratoire chez les patients dyspnéiques et de confirmer la position d’un tube endotrachéal lors d’une intubation endotrachéale, l’échographie pulmonaire a pris une place prépondérante dans la prise en charge des patients de soins critiques. La majorité des études, notamment celles sur l’intubation endotrachéale, ont évalué la performance de cliniciens possédant une expérience considérable en échographie pulmonaire et souvent dans un cadre idéal permettant des examens d’une durée prolongée. Considérant la disponibilité grandissante de l’échographie ciblée lors des situations de stabilisation et de réanimation des patients de soins critiques, nous voulions évaluer la capacité d’un groupe de clinicien hétérogène en termes de formation échographique à identifier la présence ou l’absence de glissement pleural sur de courtes séquences (comparable à la durée probable d’un examen lors de condition de réanimation) d’échographie pulmonaire enregistrées chez des patients intubés. Un total de 280 courtes séquences (entre 4 et 7 secondes) d’échographie pulmonaire démontrant la présence ou l’absence de glissement pleural chez des patients intubés en salle d’opération ont été enregistrées puis présentées de façon aléatoire à deux groupes de cliniciens en médecine d’urgence. Le deuxième groupe avait la possibilité de s’abstenir advenant une incertitude de leur réponse. Nous avons comparé la performance selon le niveau de formation académique et échographique. Le taux moyen d’identification adéquate de la présence ou l’absence du glissement pleural par participant était de 67,5% (IC 95% : 65,7-69,4) dans le premier groupe et 73,1% (IC 95% : 70,7-75,5) dans le second (p<0,001). Le taux médian de réponse adéquate pour chacune des 280 séquences était de 74,0% (EIQ : 48,0-90,0) dans le premier groupe et 83,7% (EIQ : 53,3-96,2) dans le deuxième (p=0,006). Le taux d’identification adéquate de la présence ou absence d’un glissement pleural par les participants des deux groupes était nettement supérieur pour les séquences de l’hémithorax droit par rapport à celles de l’hémithorax gauche (p=0,001). Lorsque des médecins de formation académique et échographique variable utilisent de courtes séquences d’échographie pulmonaire (plus représentatives de l’utilisation réelle en clinique), le taux d’identification adéquate de la présence ou l’absence de glissement pleural est plus élevé lorsque les participants ont la possibilité de s’abstenir en cas de doute quant à leur réponse. Le taux de bonnes réponses est également plus élevé pour les séquences de l’hémithorax droit, probablement dû à la présence sous-jacente du cœur à gauche, la plus petite taille du poumon gauche et l’effet accru du pouls pulmonaire dans l’hémithorax gauche. Considérant ces trouvailles, la prudence est de mise lors de l’utilisation de l’identification du glissement pleural sur de courtes séquences échographique comme méthode de vérification de la position d’un tube endotrachéal lors d’une intubation endotrachéale, et ce, particulièrement pour l’hémithorax gauche. Aussi, une attention particulière devrait être mise sur la reconnaissance du pouls pulmonaire lors de l’enseignement de l’échographie pulmonaire.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The role of the bridging ligand on the effective Heisenberg coupling parameters is analyzed in detail. This analysis strongly suggests that the ligand-to-metal charge transfer excitations are responsible for a large part of the final value of the magnetic coupling constant. This permits us to suggest a variant of the difference dedicated configuration interaction (DDCI) method, presently one of the most accurate and reliable for the evaluation of magnetic effective interactions. This method treats the bridging ligand orbitals mediating the interaction at the same level than the magnetic orbitals and preserves the high quality of the DDCI results while being much less computationally demanding. The numerical accuracy of the new approach is illustrated on various systems with one or two magnetic electrons per magnetic center. The fact that accurate results can be obtained using a rather reduced configuration interaction space opens the possibility to study more complex systems with many magnetic centers and/or many electrons per center.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rhenium(bipyridine)(tricarbonyl)(picoline) units have been linked covalently to tetraphenylmetalloporphyrins of magnesium and zinc via an amide bond between the bipyridine and one phenyl substituent of the porphyrin. The resulting complexes, abbreviated as [Re(CO)(3)(Pic)Bpy-MgTPP][OTf] and [Re(CO)(3)(Pic)Bpy-ZnTPP][OTf], exhibit no signs of electronic interaction between the Re(CO)(3)(bpy) units and the metalloporphyrin units in their ground states. However, emission spectroscopy reveals solvent-dependent quenching of porphyrin emission on irradiation into the long-wavelength absorption bands localized on the porphyrin. The characteristics of the excited states have been probed by picosecond time-resolved absorption (TRVIS) spectroscopy and time-resolved infrared (TRIR) spectroscopy in nitrile solvents. The presence of the charge-separated state involving electron transfer from MgTPP or ZnTPP to Re(bpy) is signaled in the TRIR spectra by a low-frequency shift in the nu(CO) bands of the Re(CO)(3) moiety similar to that observed by spectroelectrochemical reduction. Long-wavelength excitation of [Re(CO)(3)(Pic)Bpy-MTPP][OTf] results in characteristic TRVIS spectra of the S-1 state of the porphyrin that decay with a time constant of 17 ps (M = Mg) or 24 ps (M = Zn). The IR bands of the CS state appear on a time scale of less than 1 ps (Mg) or ca. 5 ps (Zn) and decay giving way to a vibrationally excited (i.e., hot) ground state via back electron transfer. The IR bands of the precursors recover with a time constant of 35 ps (Mg) or 55 ps (Zn). The short lifetimes of the charge-transfer states carry implications for the mechanism of reaction in the presence of triethylamine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Understanding the origin of the properties of metal-supported metal thin films is important for the rational design of bimetallic catalysts and other applications, but it is generally difficult to separate effects related to strain from those arising from interface interactions. Here we use density functional (DFT) theory to examine the structure and electronic behavior of few-layer palladium films on the rhenium (0001) surface, where there is negligible interfacial strain and therefore other effects can be isolated. Our DFT calculations predict stacking sequences and interlayer separations in excellent agreement with quantitative low-energy electron diffraction experiments. By theoretically simulating the Pd core-level X-ray photoemission spectra (XPS) of the films, we are able to interpret and assign the basic features of both low-resolution and high-resolution XPS measurements. The core levels at the interface shift to more negative energies, rigidly following the shifts in the same direction of the valence d-band center. We demonstrate that the valence band shift at the interface is caused by charge transfer from Re to Pd, which occurs mainly to valence states of hybridized s-p character rather than to the Pd d-band. Since the d-band filling is roughly constant, there is a correlation between the d-band center shift and its bandwidth. The resulting effect of this charge transfer on the valence d-band is thus analogous to the application of a lateral compressive strain on the adlayers. Our analysis suggests that charge transfer should be considered when describing the origin of core and valence band shifts in other metal / metal adlayer systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Topological charge screening in the QCD vacuum is found to provide crucial nonperturbative contributions to the short-distance expansion of the pseudoscalar (0-+) glueball correlator. The screening contributions enter the Wilson coefficients and are an indispensable complement to the direct instanton contributions. They restore consistency with the anomalous axial Ward identity and remedy several flaws in the 0-+ glueball sum rules caused by direct instantons in the absence of screening (lack of resonance signals, violation of the positivity bound and of the underlying low-energy theorem). The impact of the finite width of the instanton size distribution and the (gauge-invariant) renormalization of the instanton contributions are also discussed. New predictions for the 0-+ glueball mass and decay constant are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experimental and theoretical study on the piezoelectric behaviour of PZT doped with a range of calcium ion concentrations is presented. A systematic study of the effect on the piezoelectric properties of PZT doped with various concentrations of CaO at constant sintering temperature and sintering time was carried out. The remanent polarization, planar coupling factor and frequency-thickness constant increase with calcium concentration. Ab initio perturbed ion calculations show that the lattice energy decreases with calcium addition for both tetragonal and rhombohedral phases of PZT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experimental and theoretical study of the ferroelectric and piezoelectric behavior of PZT doped with barium is presented. Ab initio perturbed ion calculations was carried out. The properties, such as remnant polarization, coercive field and the coupling factor of the PZT at constant sintering temperature was compared with the Zr4+/Ti4+ ions dislocation energy and the lattice interaction energy. An agreement between the experimental and theoretical results, with a decrease of the interaction energy and an inversion of the energy stability from tetragonal to rhombohedral phase was observed. (C) 1999 Kluwer Academic Publishers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Theoretical data using ab initio perturbed ion calculation were compared with ferroelectric and piezoelectric experimental data of strontium doped PZT. Various concentrations of SrO in PZT at constant temperature and sintering time were carried out. Experimental results, such as the remanent polarization, P-R of 6.9-8.9 muC/Cm-2, the coercive field, E-C of 6.6-7.8 kVcm, and the planar coupling factor, Kp of 0.45-0.53, were compared with the energy of Zr4+ and Ti4+ ion dislocation and the lattice interaction energy which show that strontium increment in PZT alter the energies and increase the values of piezoelectric and ferroelectric variables. Calculations of lattice energy of the rhombohedral phase show that a phase non-stability is coincident with increasing experimental values of the P-R, E-C and Kp. (C) 2001 Elsevier B.V. Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we report a study of the physicochemical, dielectric and piezoelectric properties of anionic collagen and collagen-hydroxyapatite (HA) composites, considering the development of new biomaterials which have potential applications in support for cellular growth and in systems for bone regeneration. The piezoelectric strain tensor element d(14), the elastic constant s(55) and the dielectric permittivity 8(11), were measured for the anionic collagen and collagen-HA films. The thermal analysis shows that the denaturation endotherm is at 59.47 degreesC for the collagen sample. The collagen-HA composite film shows two transitions, at 48.9 and 80.65 degreesC. The X-ray diffraction pattern of the collagen film shows a broad band characteristic of an amorphous material. The main peaks associated to the crystalline HA is present in the sample of collagen-HA. In the collagen-HA composite, one can also notice the presence of other peaks with low intensities which is an indication of the formation of other crystalline phases of apatite. The scanning electron photomicrograph of anionic collagen membranes shows very thin bundles of collagen. The scanning electron photomicrography of collagen-HA film also show deposits of hydroxyapatite on the collagen fibers forming larger bundles and suggesting that a collagenous structure of reconstituted collagen fibers could act as nucleators for the formation of apatite crystal similar to those of bone. The piezoelectric strain tensor element d(14) was measured for the anionic collagen, with a value of 0.062 pC N-1, which is in good agreement compared with values reported in the literature obtained with other techniques. For the collagen-HA composite membranes, a slight decrease of the value of the piezoelectricity (0.041 pC N-1) was observed. The anionic collagen membranes present the highest density, dielectric permittivity and lowest frequency constant f.L. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Piezoelectric actuators are widely used in positioning systems which demand high resolution such as scanning microscopy, fast mirror scanners, vibration cancellation, cell manipulation, etc. In this work a piezoelectric flextensional actuator (PFA), designed with the topology optimization method, is experimentally characterized by the measurement of its nanometric displacements using a Michelson interferometer. Because this detection process is non-linear, adequate techniques must be applied to obtain a linear relationship between an output electrical signal and the induced optical phase shift. Ideally, the bias phase shift in the interferometer should remain constant, but in practice it suffers from fading. The J1-J4 spectral analysis method provides a linear and direct measurement of dynamic phase shift in a no-feedback and no-phase bias optical homodyne interferometer. PFA application such as micromanipulation in biotechnology demands fast and precise movements. So, in order to operate with arbitrary control signals the PFA must have frequency bandwidth of several kHz. However as the natural frequencies of the PFA are low, unwanted dynamics of the structure are often a problem, especially for scanning motion, but also if trajectories have to be followed with high velocities, because of the tracking error phenomenon. So the PFA must be designed in such a manner that the first mechanical resonance occurs far beyond this band. Thus it is important to know all the PFA resonance frequencies. In this work the linearity and frequency response of the PFA are evaluated up to 50 kHz using optical interferometry and the J1-J4 method.