967 resultados para Packing-houses
Resumo:
Endovascular coiling is a well-established therapy for treating intracranial aneurysms. Nonetheless, postoperative hemodynamic changes induced by this therapy remain not fully understood. The purpose of this work is to assess the influence of coil configuration and packing density on intra-aneurysmal hemodynamics
Resumo:
The relationship between the structures of protein-ligand complexes existing in the crystal and in solution, essential in the case of fragment-based screening by X-ray crystallography (FBS-X), has been often an object of controversy. To address this question, simultaneous co-crystallization and soaking of two inhibitors with different ratios, Fidarestat (FID; K(d) = 6.5 nM) and IDD594 (594; K(d) = 61 nM), which bind to h-aldose reductase (AR), have been performed. The subatomic resolution of the crystal structures allows the differentiation of both inhibitors, even when the structures are almost superposed. We have determined the occupation ratio in solution by mass spectrometry (MS) Occ(FID)/Occ(594) = 2.7 and by X-ray crystallography Occ(FID)/Occ(594) = 0.6. The occupancies in the crystal and in solution differ 4.6 times, implying that ligand binding potency is influenced by crystal contacts. A structural analysis shows that the Loop A (residues 122-130), which is exposed to the solvent, is flexible in solution, and is involved in packing contacts within the crystal. Furthermore, inhibitor 594 contacts the base of Loop A, stabilizing it, while inhibitor FID does not. This is shown by the difference in B-factors of the Loop A between the AR-594 and AR-FID complexes. A stable loop diminishes the entropic energy barrier to binding, favoring 594 versus FID. Therefore, the effect of the crystal environment should be taken into consideration in the X-ray diffraction analysis of ligand binding to proteins. This conclusion highlights the need for additional methodologies in the case of FBS-X to validate this powerful screening technique, which is widely used.
Resumo:
Selostus: Maanviljelijöiden altistuminen pölyille ja kaasuille nykyaikaisissa navetoissa
Resumo:
PURPOSE: To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤ 12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. RESULTS: Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). CONCLUSION: Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.
Resumo:
Previous studies have demonstrated that poultry house workers are exposed to very high levels of organic dust and consequently have an increased prevalence of adverse respiratory symptoms. However, the influence of the age of broilers on bioaerosol concentrations has not been investigated. To evaluate the evolution of bioaerosol concentration during the fattening period, bioaerosol parameters (inhalable dust, endotoxin and bacteria) were measured in 12 poultry confinement buildings in Switzerland, at three different stages of the birds' growth; samples of air taken from within the breathing zones of individual poultry house employees as they caught the chickens ready to be transported for slaughter were also analysed. Quantitative polymerase chain reaction (Q-PCR) was used to assess the quantity of total airborne bacteria and total airborne Staphylococcus species. Bioaerosol levels increased significantly during the fattening period of the chickens. During the task of catching mature birds, the mean inhalable dust concentration for a worker was 26 +/- 1.9 mg m(-3) and endotoxin concentration was 6198 +/- 2.3 EU m(-3) air, >6-fold higher than the Swiss occupational recommended value (1000 EU m(-3)). The mean exposure level of bird catchers to total bacteria and Staphylococcus species measured by Q-PCR is also very high, respectively, reaching values of 53 (+/-2.6) x 10(7) cells m(-3) air and 62 (+/-1.9) x 10(6) m(-3) air. It was concluded that in the absence of wearing protective breathing apparatus, chicken catchers in Switzerland risk exposure beyond recommended limits for all measured bioaerosol parameters. Moreover, the use of Q-PCR to estimate total and specific numbers of airborne bacteria is a promising tool for evaluating any modifications intended to improve the safety of current working practices
Resumo:
Courtyard houses are attested at several sites in southern Gaul between the 5th and the 1st centuries BC. They represent a new concept when compared to the traditional protohistoric houses of the region and have often been interpreted in terms of Mediterranean, Greek or Italic influences. Regardless of their origin, exogenous influences or evolution, these houses suggest the emergence of social differentiation and elites in several of the main settlements. This article analyses the significance of the various courtyard house categories in the context of local, indigenous societies, while trying to understand the social implications of this new type of residence. In a wider context, the development of domestic architecture during the Iron Age is analysed alongside the relationships between changing uses of space and social changes.
Resumo:
Abstract
Resumo:
Previous studies have demonstrated that poultry-house workers are exposed to very high levels of organic dust and consequently have an increased prevalence of adverse respiratory symptoms. However, the influence of the age of broilers, on bioaerosol concentrations has not been investigated. To evaluate the evolution of bioaerosol concentration during the fattening period, bioaerosol parameters (inhalable dust, endotoxin and bacteria) were measured in 12 poultry confinement buildings in Switzerland, at 3 different stages of the birds' growth; Samples of air taken from within the breathing zones of individual poultry-house employees as they caught the chickens ready to be transported for slaughter, were also analysed. Quantitative PCR (Q-PCR) was used to assess the quantity of total airborne bacteria and total airborne Staphylococcus species. Bioaerosol levels increased significantly during the fattening period of the chickens. During the task of catching mature birds, the mean inhalable dust concentration for a worker was 31 ± 4.7 mg/m3, and endotoxin concentration was 11'080 ± 3436 UE/m3 air, more than ten-fold higher than the Swiss occupational recommended value (1000 UE/m3). The mean exposure level of bird catchers to total bacteria and Staphylococcus species measured by Q-PCR is also very high, respectively reaching values of 72 (± 11) x107 cells/m3 air and 70 (± 16) x106/m3 air. It was concluded that in the absence of wearing protective breathing apparatus, chicken catchers in Switzerland risk exposure beyond recommended limits for all measured bioaerosol parameters. Moreover, the use of Q-PCR to estimate total and specific numbers of airborne bacteria is a promising tool for evaluating any modifications intended to improve the safety of current working practices.
Principal components analysis for quality evaluation of cooled banana 'Nanicão' in different packing
Resumo:
This work aims determinate the evaluation of the quality of 'Nanicão' banana, submitted to two conditions of storage temperature and three different kinds of package, using the technique of the Analysis of Principal Components (ACP), as a basis for an Analysis of Variance. The fruits used were 'Nanicão' bananas, at ripening degree 3, that is, more green than yellow. The packages tested were: "Torito" wood boxes, load capacity: 18 kg; "½ box" wood boxes, load capacity: 13 kg; and cardboard boxes, load capacity: 18 kg. The temperatures assessed were: room temperature (control); and (13±1ºC), with humidity controlled to 90±2,5%. Fruits were discarded when a sensory analysis determined they had become unfit for consumption. Peel coloration, percentages of imperfection, fresh mass, total acidity, pH, total soluble solids and percentages of sucrose were assessed. A completely randomized design with a 2-factorial treatment structure (packing X temperature) was used. The obtained data were analyzed through a multivariate analysis known as Principal Components Analysis, using S-plus 4.2. The conclusion was that the best packages to preserve the fruit were the ½ box ones, which proves that it is necessary to reduce the number of fruits per package to allow better ventilation and decreases mechanical injuries and ensure quality for more time.
Resumo:
We present molecular dynamics simulations of a simple model for polymer melts with intramolecular barriers. We investigate structural relaxation as a function of the barrier strength. Dynamic correlators can be consistently analyzed within the framework of the mode coupling theory of the glass transition. Control parameters are tuned in order to induce a competition between general packing effects and polymer-specific intramolecular barriers as mechanisms for dynamic arrest. This competition yields unusually large values of the so-called mode coupling theory exponent parameter and rationalizes qualitatively different observations for simple bead-spring and realistic polymers. The systematic study of the effect of intramolecular barriers presented here also establishes a fundamental difference between the nature of the glass transition in polymers and in simple glass formers.
Resumo:
The problem of choosing the heating system is always relevant when building new houses. Type of energy source (solid fuel, liquid fuel, gas, electricity, alternative sources) is the main issue in choosing the heating system. The work gives a comprehensive overview of heating methods, determines their advantages and disadvantages taking into account economical and ecological situations in Finland and Russia. Quantitative contribution of single Finnish and Russian detached houses in the overall level of carbon dioxide emissions is estimated when using each method. Comparison of Russian and Finnish energy markets and their impact on electricity pricing is made in the work. The influence of air pollution on environmental offsets according to Russian and Finnish legislative and normative acts is determined.
Resumo:
The spatial distribution of illuminance and the electric consumption of artificial lighting system is one of the main problems related to broiler production. Therefore, the aim of this study was to evaluate the spatial distribution of luminance level and energy efficiency of different lighting systems for broiler houses. Six types of lamps were tested in two different configurations to find the minimum illuminance of 20 and 5 lux. The tested lamps were incandescent (IL) 100 W, compact fluorescent (CFL) 34 W, mixed (ML) 160 W, sodium vapor (SVL) 70 W, T8 fluorescent tube (T8 FTL) 40 W and T5 fluorescent tube (T5 FTL) 28 W. The first four were evaluated with and without reflective light fixture and the latter two without light fixture. It was observed that the tested system with light fixtures negatively affected the spatial distribution of illuminance inside the house. The systems composed by IL and ML without light fixture led to better results in meeting the minimum illuminance of 20 lux and 5 lux, respectively. T5 FTL presented the lowest energy demand.