957 resultados para PRESSURE RANGE GIGA PA
Resumo:
The response of an originally developed catalytic sensor with a Nb2 O5 nanowire array at its outer surface to the varying density of O atoms is experimentally and numerically studied. This technique can be used to measure one order of magnitude lower densities of O atoms and achieve a stable linear response in a significantly broader pressure range compared to conventional catalytic probes with a flat surface. The nanostructured outer surface also acts as a thermal barrier against sensor overheating. This approach is generic and can be used for reactive species detection in other reactive gas environments.
Resumo:
Transitions between the two discharge modes in a low-frequency (∼460 kHz) inductively coupled plasma sustained by an internal oscillating radio frequency (rf) current sheet are studied. The unidirectional rf current sheet is generated by an internal antenna comprising two orthogonal sets of synphased rf currents driven in alternately reconnected copper litz wires. It is shown that in the low-to-intermediate pressure range the plasma source can be operated in the electrostatic (E) and electromagnetic (H) discharge modes. The brightness of the E -mode argon plasma glow is found remarkably higher than in inductively coupled plasmas with external flat spiral "pancake" coils. The cyclic variations of the input rf power result in pronounced hysteretic variations of the optical emission intensity and main circuit parameters of the plasma source. Under certain conditions, it appears possible to achieve a spontaneous E→H transition ("self-transition"). The observed phenomenon can be attributed to the thermal drift of the plasma parameters due to the overheating of the working gas. The discharge destabilizing factors due to the gas heating and step-wise ionization are also discussed. © 2005 American Vacuum Society.
Resumo:
Operation regimes, plasma parameters, and applications of the low-frequency (∼500 kHz) inductively coupled plasma (ICP) sources with a planar external coil are investigated. It is shown that highly uniform, high-density (ne∼9×1012 cm-3) plasmas can be produced in low-pressure argon discharges with moderate rf powers. The low-frequency ICP sources operate in either electrostatic (E) or electromagnetic (H) regimes in a wide pressure range without any Faraday shield or an external multipolar magnetic confinement, and exhibit high power transfer efficiency, and low circuit loss. In the H mode, the ICP features high level of uniformity over large processing areas and volumes, low electron temperatures, and plasma potentials. The low-density, highly uniform over the cross-section, plasmas with high electron temperatures and plasma and sheath potentials are characteristic to the electrostatic regime. Both operation regimes offer great potential for various plasma processing applications. As examples, the efficiency of the low-frequency ICP for steel nitriding and plasma-enhanced chemical vapor deposition of hydrogenated diamond-like carbon (DLC) films, is demonstrated. It appears possible to achieve very high nitriding rates and dramatically increase micro-hardness and wear resistance of the AISI 304 stainless steel. It is also shown that the deposition rates and mechanical properties of the DLC films can be efficiently controlled by selecting the discharge operating regime.
Resumo:
The sputter deposition of YBa2Cu3O7-x in a de-diode was performed in pure oxygen medium and an optical spectroscopic study of the resultant discharge revealed strong emissions from both metal atoms and oxygen ions. Emission intensities were studied in pressure range from 0.5 to 3 mbar, with substrate temperatures from 150 to 850 degrees C. Raising the substrate temperature to 850 degrees C increased the number of positive ions and excited neutral atoms. Raising the pressure decreased the emission intensities of excited neutral and ionic species. The results have been compared with those obtained from Langmuir probe measurements. The rise in emission intensities of excited neutrals and ions with temperature suggested the possibility of chemically enhanced physical sputtering of YBa2Cu3O7-x. The effect of process conditions on film composition and quality is also discussed.
Resumo:
Background: Autogenous vein grafting is widely used in regular bypassing procedures. Due to its mismatch with the host artery in both mechanical property and geometry, the graft often over expands under high arterial blood pressure and forms a step-depth where eddy flow develops, thus causing restenosis, fibrous graft wall, etc. External stents, such as sheaths being used to cuff the graft, have been introduced to eliminate these mismatches and increase the patency. Although histological and immunochemical studies have shown some positive effects of the external stent, the mechanical mismatch under the protection of an external stent remains poorly analyzed. Methods: In this study, the jugular veins taken from hypercholesterolemic rabbits were transplanted into the carotid arteries, and non-woven polyglycolic acid (PGA) fabric was used to fabricate the external stents to study the effect of the biodegradable external stent. Eight weeks after the operation, the grafts were harvested to perform mechanical tests and histological examinations. An arc tangent function was suggested to describe the relationship between pressure and cross-sectional area to analyse the compliance of the graft. Results: The results from the mechanical tests indicated that grafts either with or without external stents displayed large compliance in the low-pressure range and were almost inextensible in the high-pressure range. This was very different from the behavior of the arteries or veins in vivo. The data from histological tests showed that, with external stents, collagen fibers were more compact, whilst those in the graft without protection were looser and thicker. No elastic fiber was found in either kind of grafts. Furthermore, grafts without protection were over-expanded which resulted in much bigger cross-sectional areas. Conclusion: The PGA external extent contributes little to the reduction of the mechanical mismatch between the graft and its host artery while remodeling develops. For the geometric mismatch, it reduces the cross-section area, therefore matching with the host artery much better. Although there are some positive effects, conclusively the PGA is not an ideal material for external stent.
Resumo:
Measurement of the relation between polarisation and electric field for ferroelectric trissarcosine calcium chloride (TSCC) was made in the pressure range up to 6 kbar. The pressure dependence of the spontaneous polarisation and the coercive field were obtained, and the existence of a new pressure-induced phase and the paraelectric- ferroelectric-new phase triple point were found.
Resumo:
Controversy exists in the published literature as to the effect of silicon content and pressure on the dry sliding wear of Al---Si alloys. The present paper attempts to clarify the question by reporting a statistical analysis of data obtained from factorially designed experiments conducted on a pinon-disc machine in the pressure range 0.105–1.733 MPa and speed range 0.19–0.94 m s−1. Under these conditions it was found that, in the range 4–24 wt.% Si, wear of binary unmodified alloys does not significantly differ between the alloys. However, it is significantly less than that corresponding to an alloy containing no silicon. The effect of pressure on wear rate was found to be linear and monotonie and, over the narrow range of speeds used, the wear rate was found to be unaffected by speed. The coefficient of friction was found to be insensitive to variations in silicon content, pressure and speed.
Resumo:
A Burnett apparatus deslgned and fabrlcated was used to collect volumetric data for ethylene and ethylene-hydrogen mixtures. Measurements were made In the temperature range 298.15-423.15 K at Intervals of 25 K and In the pressure range 0.3-7.0 MPa. Vlrlal coefflclents derlved from the compresslblllty data are tabulated. The data are fltted to different equations of state.
Resumo:
Background Although guidelines suggest that vigorous physical activity (PA) confers “extra” benefits compared with those from moderate-intensity activity alone, the magnitude of this additional benefit is unclear. The aim was to compare the reduction in risk of hypertension (HT) and depressive symptoms (DS) for 12 yr in middle-age women who reported (a) only moderate-intensity PA (MOPA) and (b) a combination of moderate and vigorous PA (MVPA), after controlling for overall volume of activity. Methods The study involved 11,285 participants in the Australian Longitudinal Study on Women’s Health, who completed surveys in 1998 (age = 46–52 yr), 2001, 2004, 2007, and 2010. Generalized estimating equation models (with 3-yr time lag) were used to examine the relationship between PA in seven categories from 0 to >2000 MET·min·wk−1 and occurrence of HT and DS for women who reported MOPA or MVPA. Results For HT, risk was slightly lower for MVPA than for MOPA across the entire range of PA levels, but this difference was only significant at the highest PA level (>2000; odds ratio [OR] = 0.80 MOPA and 0.56 MVPA). For DS, OR values were similar in both groups up to 500 MET·min·wk−1, then slightly lower for MVPA than for MOPA at higher PA levels. Again, this difference was only significant at the highest PA level (>2000; OR = 0.57 MOPA and 0.42 MVPA). OR values were slightly attenuated in adjusted models. Conclusions Doing both vigorous and moderate activity does not have significant additional benefits in terms of HT and DS, above those from moderate-intensity activity alone, except at very high levels of PA.
Resumo:
An investigation of power frequency (50 Hz) surface partial discharges in dry air, using 21r/3 Rogowski profile electrodes in the low pressure range of 0.067 to 91.333 kPa, shows that for the discharges occurring symmetrically around the electrodes and just outside the uniform field region, the breakdown voltages are 20 to 30% lower than those accounted for by the usual Paschen values. Emphasis, therefore, has been given to modified values of breakdown voltages for any useful calculations. The effect of reduced pressure on inception voltage has been discussed and an attempt has been made to explain the difference between the observed and calculated values on the basis of a pressure-dependent secondary ionization coefficient. It is shown that increasing the insulation thickness in a critical pressure range (0.067 to 0.400 kPa) does not allow any significant increase in the discharge free working stress of the insulation system. At higher pressures (>0.400 kPa) the increase in inception voltage with thickness and pressure follows an equation which is expected to hold for other insulating materials as well.
Resumo:
The solubilities of three chlorophenols, namely, 4-chlorophenol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol, in supercritical carbon dioxide were determined at temperatures from (308 to 3 18) K in the pressure range of (8.8 to 15.6) MPa. The Solubilities were determined both in the absence of cosolvents and in the presence of two cosolvents, methanol and acetone. The solubilities (in the absence of cosolvents) in mole fraction of 4-chlorophenol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol at 308 K were in the range of (0.0113 to 0.0215), (0.0312 to 0.0645), and (0.008 to 0.0173), respectively. The Solubilities of the chlorophenols followed the order 2,4-dichlorophenol & 4-chlorophenol & phenol & 2,4,6-trichlorophenol & pentachlorophenol. The solubility data were correlated with the Charstil model and with the Mendez-Santiago and Teja model. The overall deviation between the experimental data and the correlated results Was less than 6 % in averaged absolute relative deviation (AARD) for both of the models.
Resumo:
Vapor-liquid equilibrium data for the systems diisopropyl ether-n-heptane and diisopropyl ether-carbon tetrachloride have been reported at pressures of 760, 1520, and 2280 mm. of Hg. The systems form ideal mixtures under the pressure range studied.
Resumo:
For highly compressible normally consolidated saturated soil the compression index, Cc, is not constant over the entire pressure range. However, the ratio of the compression index and the initial specific volume, generally known as the compression ratio, appears to be constant. Thus settlement seems to depend on Cc/(1 + e) rather than Cc alone. Using the theoretical zero air voids line and the generalized compressibility equation for normally consolidated saturated soils, a generalized and simple equation for compression has been derived in the form: C'c = 0.003wL.
Resumo:
The equilibrium solubility of a pharmaceutical compound. 1,5-dimethy1-2-phenyl-4-propan-2-ylpyrazol-3-one (propyphenazone, isopropylantipyrine) in supercritical carbon dioxide (SCCO2) was experimentally determined by a saturation method at 308, 318 and 328 K. over the pressure range of 9.0-19.0 MPa. The solubility data satisfied the self-consistency test, proposed by Mendez-Santiago and Teja. A new association model was derived to correlate the solubilities of pharmaceutical compounds in SCCO2. Solubility data from 54 different pharmaceutical compounds including steroids, antibiotics, anti-inflammatory, antioxidants, statins and specific functional drugs were collected from literature. The model successfully correlated the experimental results for the solubilities of all these compounds in SCCO2 within 12% AARD. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A compression moulded Kevlar-phenolic resin composite consisting of 30 wt% continuous fibres was slid against a steel disc such that the fibre axis was normal to the sliding plane. The sliding experiments were conducted in a normal pressure range of 0.47–4.27 MPa and at a sliding speed of 0.5 ms–1. The initial sliding interaction is abrasive. With further sliding, as patches of polymer transfer film develop on the polymer pin and counterface, the interaction becomes adhesive and steady-state friction is established. The wear resistance of the polymer was found to be related to the stability of this film.