828 resultados para POLY(DIMETHYLSILOXANE) MICROFLUIDIC DEVICES
Resumo:
The field of bioelectronics involves the use of electrodes to exchange electrical signals with biological systems for diagnostic and therapeutic purposes in biomedical devices and healthcare applications. However, the mechanical compatibility of implantable devices with the human body has been a challenge, particularly with long-term implantation into target organs. Current rigid bioelectronics can trigger inflammatory responses and cause unstable device functions due to the mechanical mismatch with the surrounding soft tissue. Recent advances in flexible and stretchable electronics have shown promise in making bioelectronic interfaces more biocompatible. To fully achieve this goal, material science and engineering of soft electronic devices must be combined with quantitative characterization and modeling tools to understand the mechanical issues at the interface between electronic technology and biological tissue. Local mechanical characterization is crucial to understand the activation of failure mechanisms and optimizing the devices. Experimental techniques for testing mechanical properties at the nanoscale are emerging, and the Atomic Force Microscope (AFM) is a good candidate for in situ local mechanical characterization of soft bioelectronic interfaces. In this work, in situ experimental techniques with solely AFM supported by interpretive models for the characterization of planar and three-dimensional devices suitable for in vivo and in vitro biomedical experimentations are reported. The combination of the proposed models and experimental techniques provides access to the local mechanical properties of soft bioelectronic interfaces. The study investigates the nanomechanics of hard thin gold films on soft polymeric substrates (Poly(dimethylsiloxane) PDMS) and 3D inkjet-printed micropillars under different deformation states. The proposed characterization methods provide a rapid and precise determination of mechanical properties, thus giving the possibility to parametrize the microfabrication steps and investigate their impact on the final device.
Resumo:
Single-point diamond turning of monocrystalline semiconductors is an important field of research within brittle materials machining. Monocrystalline silicon samples with a (100) orientation have been diamond turned under different cutting conditions (feed rate and depth of cut). Micro-Raman spectroscopy and atomic force microscopy have been used to assess structural alterations and surface finish of the samples diamond turned under ductile and brittle modes. It was found that silicon undergoes a phase transformation when machined in the ductile mode. This phase transformation is evidenced by the creation of an amorphous surface layer after machining which has been probed by Raman scattering. Compressive residual stresses are estimated for the machined surface and it is observed that they decrease with an increase in the feed rate and depth of cut. This behaviour has been attributed to the formation of subsurface cracks when the feed rate is higher than or equal to 2.5 mu m/rev. The surface roughness was observed to vary with the feed rate and the depth of cut. An increase in the surface roughness was influenced by microcrack formation when the feed rate reached 5.0 mu m/rev. Furthermore, a high-pressure phase transformation induced by the tool/material interaction and responsible for the ductile response of this typical brittle material is discussed based upon the presented Raman spectra. The application of this machining technology finds use for a wide range of high quality components, for example the creation of a micrometre-range channel for microfluidic devices as well as microlenses used in the infrared spectrum range.
Resumo:
The commercially available Jacobsen catalyst, Mn(salen), was occluded in hybrid polymeric membranes based on poly(dimethylsiloxane) (PDMS) and poly(vinyl alcohol) (PVA). The obtained systems were characterized by UV-vis spectroscopy and SEM techniques. The membranes were used as a catalytic barrier between two different phases: an organic substrate phase (cyclooctene or styrene) in the absence of solvent, and an aqueous solution of either t-BuOOH or H(2)O(2). Membranes containing different percentages of PVA were prepared, in order to modulate their hydrophilic/hydrophobic swelling properties. The occluded complex proved to be an efficient catalyst for the oxidation of alkenes. The new triphasic system containing a cheap and easily available catalyst allowed substrate oxidation and easy product separation using ""green"" oxidants. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
This thesis explores the development and employment of microfluidic devices as a tool for studying the effect of the surrounding environment on embryonic stem cells during the migration phenomena. Different single-cell microchips were designed and manufactured to study mouse embryonic fibroblasts (MEFs) migration towards an environmental variation (increase of serum concentration in the culture medium) that was expected to function as a motility stimuli. Considering the experimental, cells were injected into the microchips chambers and individually isolated by dedicated cell traps with view to a single-cell analysis. Once fribroblasts were attached to the surface, culture medium with an increased serum level was subsequently injected in an adjacent chamber to promote the formation of a serum concentration gradient. The gradient established between the chambers could be sensed by the fibroblasts and thus triggered the cells mobilization towards and in the direction of the richer serum medium. Additionally, the experiment allowed the observation of MEFs’ structural reorganization when migrating through micro-tunnels containing widths below the cell size, suggesting a cytoskeleton rearrangement on account of the nutritional stimulus introduced. Furthermore, results indicate that fibronectin promotes MEFs adhesion to the substrate and that MEFs migration is characterized as haptotactic.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Engenharia Clínica)
Resumo:
Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.
Resumo:
PDMS-based microfluidic devices combined with lanthanide-based immunocomplexes have been successfully tested for the multiplex detection of biomarkers on cancerous tissues, revealing an enhanced sensitivity compared to classical organic dyes.
Resumo:
Contamination with arsenic is a recurring problem in both industrialized and developing countries. Drinking water supplies for large populations can have concentrations much higher than the permissible levels (for most European countries and the United States, 10 μg As per L; elsewhere, 50 μg As per L). Arsenic analysis requires high-end instruments, which are largely unavailable in developing countries. Bioassays based on genetically engineered bacteria have been proposed as suitable alternatives but such tests would profit from better standardization and direct incorporation into sensing devices. The goal of this work was to develop and test microfluidic devices in which bacterial bioreporters could be embedded, exposed and reporter signals detected, as a further step towards a complete miniaturized bacterial biosensor. The signal element in the biosensor is a nonpathogenic laboratory strain of Escherichia coli, which produces a variant of the green fluorescent protein after contact to arsenite and arsenate. E. coli bioreporter cells were encapsulated in agarose beads and incorporated into a microfluidic device where they were captured in 500 × 500 μm(2) cages and exposed to aqueous samples containing arsenic. Cell-beads frozen at -20 °C in the microfluidic chip retained inducibility for up to a month and arsenic samples with 10 or 50 μg L(-1) could be reproducibly discriminated from the blank. In the 0-50 μg L(-1) range and with an exposure time of 200 minutes, the rate of signal increase was linearly proportional to the arsenic concentration. The time needed to reliably and reproducibly detect a concentration of 50 μg L(-1) was 75-120 minutes, and 120-180 minutes for a concentration of 10 μg L(-1).
Resumo:
The amazing world of micro total analysis systems has provided a true revolution in analytical chemistry in recent years. The application of the microfluidic devices for chemical and biochemical processing has attracted considerable interest due to its advantages such as reduced sample and reagent consumption, processing time, energy, waste, cost, and portability. The aim of the present report is to disseminate the state of the art related to the miniaturization science in Analytical Chemistry. Historical progress, microfabrication technologies, required instrumentation and applications of the mTAS are presented in the current article, with special attention to the Brazilian contributions.
Resumo:
C18 chemically bonded sorbents have been the main materials used in solid phase extraction (SPE). However, due their high hydrophobicity some hydrophobic solutes are strongly retained leading to the consumption of larger quantities of organic solvent for efficient recoveries. This work presents a sorbent with lower hydrophobicity but similar selectivity to the C18 sorbent, prepared by thermal immobilization of poly(dimethylsiloxane-co-alkylmethylsiloxane) (PDAS) on silica. PDAS has organic chains with methyl groups alternating with octadecyl or hexadecyl groups in its monomeric unities. For the Si(PDAS) sorbent presented, the polymeric layer was physically adsorbed on the silica surface with 12% carbon load. Although the coating of silica with the polymeric layer was incomplete, the PDAS provided better protection for the silica surface groups, promoting mostly hydrophobic interactions between analytes and the sorbent. Sorption isotherm studies revealed that the retention of hydrophobic solutes on Si(PDAS) was less intense than on conventional sorbents, confirming the lower hydrophobicity of the lab-made sorbent. Additional advantages of Si(PDAS) include simplicity and low cost of preparation, making this material a potential sorbent for the analysis of highly hydrophobic solutes.
Resumo:
During the last decade, large and costly instruments are being replaced by system based on microfluidic devices. Microfluidic devices hold the promise of combining a small analytical laboratory onto a chip-sized substrate to identify, immobilize, separate, and purify cells, bio-molecules, toxins, and other chemical and biological materials. Compared to conventional instruments, microfluidic devices would perform these tasks faster with higher sensitivity and efficiency, and greater affordability. Dielectrophoresis is one of the enabling technologies for these devices. It exploits the differences in particle dielectric properties to allow manipulation and characterization of particles suspended in a fluidic medium. Particles can be trapped or moved between regions of high or low electric fields due to the polarization effects in non-uniform electric fields. By varying the applied electric field frequency, the magnitude and direction of the dielectrophoretic force on the particle can be controlled. Dielectrophoresis has been successfully demonstrated in the separation, transportation, trapping, and sorting of various biological particles.
Resumo:
Els polímers són una sèrie de compostos que troben un ampli ventall d'aplicacions en la indústria actual. Un exemple són les espumes de poliuretà, estructures de tipus cel·lular obtingudes mitjançant la reacció química entre compostos de tipus isocianat i compostos de tipus poliol (polièters amb diferent nombre de grups hidroxil). És imprescindible l'ús d'additius d'estructura tensioactiva (surfactants de silicona) per estabilitzar el procés d'espumació i per proporcionar una estructura cel·lular ordenada i homogènia en mida i distribució. La síntesis i caracterització de les molècules precursores (polihidrosiloxans i polièters al·lílics), l'estudi de la reacció d'hidrosililació com a via d'obtenció dels diferents surfactants per reacció d'addició entre els polihidrosiloxans i els polièters al·lílics i la caracterització i avaluació en formulacions comercials de poliuretà dels surfactants sintetitzats han constituït els objectius del present treball. MEMÒRIA La Tesi Doctoral ha estat presentada seguint el següent esquema: CAPÍTOL I. INTRODUCCIÓ A LA QUÍMICA DEL POLIURETÀ. Es presenten els principis de la química del poliuretà, fent esment dels recents avenços en la síntesis i caracterització d'aquests compostos polimèrics, així com un apartat concret centrat en els surfactants de silicona. Es presenten les estructures habituals d'aquests compostos comercials i es detallen les reaccions de síntesi i les característiques físiques que aquests compostos proporcionen a les espumes de poliuretà. CAPÍTOL II. OBJECTIUS. 1.- Síntesis y caracterització d'una àmplia gamma de poliglicols al·lílics i de polihidrosiloxans amb grups hidrur reactius, ambdós precursors d'estructures polimèriques de tipus surfactant. 2.- Estudi de la reacció d'hidrosililació com a via de formació d'enllaços Si-C no hidrolitzables, mitjançant la reacció d'addició entre els substrats al·lílics insaturats i els polisiloxans amb grups hidrur reactius. 3.- Caracterització de les estructures polimèriques de tipus surfactant sintetitzades i avaluació d'aquestes en formulacions de poliuretà, a fi de relacionar l'estructura química d'aquests oligómers amb els efectes físics que originen en l'espuma de poliuretà. CAPÍTOL III. SÍNTESI I CARACTERITZACIÓ DE SUBSTRATS AL·LÍLICS INSATURATS DE TIPUS POLIGLICOL. S'han caracteritzat per HPLC-UV una sèrie de polietilenglicols comercials. S'ha estudiat la reacció de derivatització al·lílica sobre els grups hidroxil dels polièters comercials (PEG, PPG i copolímers PEG-PPG) i s'han caracteritzat exhaustivament els productes sintetitzats (1H,13C-RMN, GC, GC-MS, FTIR, ESI-MS, HPLC-UV). S'ha iniciat un estudi de polimerització aniònica sobre nous epòxids amb un punt de diversitat molecular, sintetitzant-se i caracteritzant-se els corresponents nous polièters obtinguts. CAPÍTOL IV. SÍNTESI I CARACTERITZACIÓ DE POLIHIDROSILOXANS REACTIUS. S'estudia la síntesis de polihidrosiloxans amb grups hidrur reactius, mitjançant la reacció de polimerització aniònica d'obertura d'anell ("AROP, anionic ring opening polimerization") i mitjançant la reacció de polimerització per equilibració catiònica. Es presenta una caracterització exhaustiva dels productes sintetitzats i es descriu la naturalesa de la microestructura polimèrica a partir de la distribució bivariant dels copolímers PDMS-co-PHMS (poli(dimetilsiloxà)-co-poli(hidrometilsiloxà)). CAPÍTOL V. ESTUDI SISTEMÀTIC DE LA REACCIÓ D'HIDROSILILACIÓ. S'ha estudiat la reacció d'hidrosililació amb la finalitat de sintetitzar estructures copolimèriques poliglicol-polisiloxà a partir de la reacció de polisiloxans hidrur reactius i polièters al·lílics. S'han provat diferents catalitzadors (Pt/C 5%, cat. de Speier i cat. de Karstedt), s'han sintetitzat diferents estructures tensoactives (lineals i ramificades) i s'ha modelitzat les diferents reaccions secundàries observades, per presentar un estudi mecanístic de la reacció d'hidrosililació aplicada a la síntesis de molècules d'elevat PM a partir de la reacció entre substrats al·lílics insaturats i polihidrosiloxans. CAPÍTOL VI. AVALUACIÓ DELS SURFACTANTS EN FORMULACIONS DE POLIURETÀ. S'ha estudiat la idoneïtat dels surfactants de silicona sintetitzats en diferents formulacions de poliuretà comercials. S'ha relacionat el comportament físic d'aquests surfactants en les espumes de poliuretà amb la seva estructura química a partir de l'anàlisi per microscòpia electrònica de rastreig. CAPÍTOL VII. CONCLUSIONS. S'han esposat les conclusions extretes de cada capítol.
Resumo:
In this report, we describe a rapid and reliable process to bond channels fabricated in glass substrates. Glass channels were fabricated by photolithography and wet chemical etching. The resulting channels were bonded against another glass plate containing a 50-mu m thick PDMS layer. This same PDMS layer was also used to provide the electrical insulation of planar electrodes to carry out capacitively coupled contactless conductivity detection. The analytical performance of the proposed device was shown by using both LIF and capacitively coupled contactless conductivity detection systems. Efficiency around 47 000 plates/m was achieved with good chip-to-chip repeatability and satisfactory long-term stability of EOF. The RSD for the EOF measured in three different devices was ca. 7%. For a chip-to-chip comparison, the RSD values for migration time, electrophoretic current and peak area were below 10%. With the proposed approach, a single chip can be fabricated in less than 30 min including patterning, etching and sealing steps. This fabrication process is faster and easier than the thermal bonding process. Besides, the proposed method does not require high temperatures and provides excellent day-to-day and device-to-device repeatability.
Resumo:
Bill & Melinda Gates Foundation[51308]
Resumo:
This technical note describes a detailed study on wax printing, a simple and inexpensive method for fabricating microfluidic devices in paper using a commercially available printer and hot plate. The printer prints patterns of solid wax on the surface of the paper, and the hot plate melts the wax so that it penetrates the full thickness of the paper. This process creates complete hydrophobic barriers in paper that define hydrophilic channels, fluid reservoirs, and reaction zones. The design of each device was based on a simple equation that accounts for the spreading of molten wax in paper.