1000 resultados para PF-MEKC-MS
Resumo:
The novel asymmetric metallo-organic triads cis- and trans-[B(4-py)BPFPH(2){Ru(3)O(Ac)(6)(py)(2)}(Ru(bpy)(2)Cl}](PF(6))(2) (5a,b) for which cis- and trans-B(4-py)BPFPH(2)=5,10-bis(pentafluorophenyl)-15,20-bis(4-pyridyl)porphyrin and 5,15-bis(pentafluorophenyl)-10,20-bis(4-pyridyl)porphyrin, respectively; Ac = acetate; py = pyridine and bpy = 2,2`-bipyridine, as well as their corresponding monosubstituted dyads cis- and trans-[B(4-py)BPFPH(2){Ru(3)O(Ac)(6)(py)(2)}]PF(6) (4a,b) have been structurally characterized via electrospray ionization mass spectrometry (ESI-MS and ESI-MS/MS). The ESI-MS of dyads 4a,b display two characteristic Ru-multicomponent clusters of isotopologue ions corresponding to singly charged ions 4a,b(+) of m/z 1629 and doubly charged ions [4a,b+H](2+) of m/z 815 and the triads 5a,b are detected by ESI-MS as the intact doubly charged cluster of isotopologue ions of m/z 1039 [5a,b](2+). The ESI-MS/MS of 4a,b(+), [4a,b+H](2+) and [5a,b](2+) reveal characteristic dissociation pathways, which confirm the structural assignments providing additional information on the intrinsic binding strengths of the gaseous ions. Although the gas-phase behavior of each pair of isomers was rather similar, the less symmetric dyads 4a,b are distinguished via the (1)H NMR spectral profile of the pyrrolic signals. Exploratory photophysical assays have shown that both modifying motifs alter the porphyrinic core emission profile, opening the possibility to use these asymmetric systems as photophysical devices. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
The trans-[RUCl(2)(L)(4)], trans-[Ru(NO)Cl (L)(4)](PF(6))(2) (L = isonicotinamide and 4-acetylpyridine) and trans-[Ru(NO)(OH)(py)(4)]Cl(2) (py = pyridine) complexes have been prepared and characterized by elemental analysis, UV-visible, infrared, and (1)H NMR spectroscopies, and cyclic voltammetry. The MLCT band energies of trans-[RUCl(2)(L)(4) increase in the order 4-acpy < isn < py. The reduction potentials of trans-[RuCl(2)(L)(4)] and trans-[Ru(NO)Cl(L)(4)](2+) increase in the order py < isn < 4-acpy. The stretching band frequency. v(NO), of the nitrosyl complexes ranges from 1913 to 1852 cm(-1) indicating a nitrosonium character for the NO ligand. Due to the large pi-acceptor ability of the equatorial ligands, the coordinated water is much more acidic in the water soluble trans-[Ru(NO)(H(2)O)(py)(4)](3+) than in trans-[Ru(NO)(H(2)O)(NH(3))(4)](3+) (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
This article describes the enantioseleclive analysis of cyclophosphamide (CPA) in human plasma using LC-MS/MS. CPA enantiomers were extracted from plasma using a mixture of ethyl acetate and chloroform (75:25, v/v). The enantiomers were separated on a Chiralcel(R) OD-R column, with the mobile phase consisting of a mixture of acetonitrile and water (75:25, v/v) plus 0.2% formic acid. The protonaled ions and their respective product ions were monitored using two functions, 261 > 141 for CPA enantiomers and 189 > 104 for the internal standard (antipyrine). Recovery rates were higher than 95% and the quantification limit was 2.5-ng/ml plasma for both enantiomers. The coefficients of variation and the relative errors obtained for the validation of intra- and interassay precision and accuracy were less than 10%. The method was applied for the investigation of the enantioselective pharmacokinetics of CPA in a lupus nephritis patient treated with 1 g CPA infused over 2 h and in a breast cancer patient treated with 0.9 g infused over 1 h. No stereoselectivity in the pharmacokinetic parameters was observed for either patient. Clearance values of 2.63 and 2.93 l/h and of 3.36 and 3.61 l/h for (-)-(S) and (+)-(R)-CPA were obtained for the breast cancer and lupus nephritis patient., respectively. Chirality 21:383-389, 2009. (C) 2008 Wiley-Liss, Inc.
Resumo:
Labetalol is clinically available as a mixture of two racemates (four stereoisomers). The stereoisomer (R,R) has as main activity the beta(1)-antagonism and the stereoisomer (S,R) is highly selective for the alpha(1) adrenoceptor and is responsible for most of the alpha-blocker activity. In the present investigation, a method for the analysis of labetalol stereoisomers in human plasma was developed and applied to pharmacokinetic studies. Plasma samples (0.5 ml) were extracted with methyl tert-butyl ether at pH 9.5. The four labetalol stereoisomers were analyzed by LC-MS/MS on a Chirobiotic (R) V column using a mobile phase consisting of methanol, acetic acid, and diethylamine, with a recovery of more than 90% for all four. The quantitation limit was 0.5 ng/ml and linearity was observed at 250 ng/ml plasma for each stereoisomer. Studies of precision and accuracy presented coefficients of variation and percentage inaccuracy of less than 15%, indicating that the method is precise and accurate. The method was applied to the study of the kinetic disposition of labetalol over a period of 12 h after oral administration of a single 100 mg dose to a hypertensive pregnant woman. The clinical study revealed stereoselectivity in the pharmacokinetics of labetalol, with a lower plasma proportion for the active stereoisomers (R,R)-labetalol and (S,R)-labetalol. The stereoselectivity observed after oral administration is due to the hepatic metabolism and the first pass effect, with an AUC((R,R))/AUC((S,S)) ratio of 0.5. Chirality 21:738-744, 2009. (C) 2008 Wiley-Liss, Inc.
Resumo:
Quantitation of progesterone (P(4)) in biological fluids is often performed by radioimmunoassay (RIA), whereas liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) has been used much less often. Due to its autoconfirmatory nature, LC-MS/MS greatly minimizes false positives and interference. Herein we report and compare with RIA an optimized LC-MS/MS method for rapid, efficient, and cost-effective quantitation of P(4) in plasma of cattle with no sample derivatization. The quantitation of plasma P(4) released from three nonbiodegradable, commercial, intravaginal P(4)-releasing devices (IPRD) over 192 h in six ovariectomized cows was compared in a pairwise study as a test case. Both techniques showed similar P(4) kinetics (P > 0.05) whereas results of P(4) quantitation by RIA were consistently higher compared with LC-MS/MS (P < 0.05) due to interference and matrix effects. The LC-MS/MS method was validated according to the recommended analytical standards and displayed P(4) limits of detection (LOD) and quantitation (LOQ) of 0.08 and a 0.25 ng/mL, respectively. The high selective LC-MS/MS method proposed herein for P(4) quantitation eliminates the risks associated with radioactive handling; it also requires no sample derivatization, which is a common requirement for LC-MS/MS quantitation of steroid hormones. Its application to multisteroid assays is also viable, and it is envisaged that it may provide a gold standard technique for hormone quantitation in animal reproductive science studies. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
The Australian Coal Industry Research Laboratory (ACIRL) furnace is scaled to simulate slagging and fouling in operating boilers. This requires that the gas and target temperatures, the heat flux, and the flow pattern be the same as those in real boilers. The gas and target temperatures are maintained by insulating the wall and cooling the target respectively. The flow pattern of a small burner cannot be the same as a large furnace. However, this flow pattern is partially compensated for by placing the slagging panels in three vertical locations. The paper develops the models of radiant heat transfer from the flame to the deposits both in pilot-scale and full-scale furnaces. They are used to compare the effective radiant heat transfer of the pilot- and full-scale furnaces. The experimental data both from the pilot- and full-scale furnaces are used to verify the incident heat flux and temperature profiles in the pilot- and full-scale furnaces. The results showed that the thermal condition in the pilot-scale furnace meets the requirements for studying the slagging regarding the gas temperature and the incident heat flux, particularly for the panel #1. The gas temperature in the convective section also meets the requirement for studying the fouling.
Resumo:
The isotope composition of Ph is difficult to determine accurately due to the lack of a stable normalisation ratio. Double and triple-spike addition techniques provide one solution and presently yield the most accurate measurements. A number of recent studies have claimed that improved accuracy and precision could also be achieved by multi-collector ICP-MS (MC-ICP-MS) Pb-isotope analysis using the addition of Tl of known isotope composition to Pb samples. In this paper, we verify whether the known isotope composition of Tl can be used for correction of mass discrimination of Pb with an extensive dataset for the NIST standard SRM 981, comparison of MC-ICP-MS with TIMS data, and comparison with three isochrons from different geological environments. When all our NIST SRM 981 data are normalised with one constant Tl-205/Tl-203 of 2.38869, the following averages and reproducibilities were obtained: Pb-207/Pb-206=0.91461+/-18; Pb-208/Ph-206 = 2.1674+/-7; and (PbPh)-Pb-206-Ph-204 = 16.941+/-6. These two sigma standard deviations of the mean correspond to 149, 330, and 374 ppm, respectively. Accuracies relative to triple-spike values are 149, 157, and 52 ppm, respectively, and thus well within uncertainties. The largest component of the uncertainties stems from the Ph data alone and is not caused by differential mass discrimination behaviour of Ph and Tl. In routine operation, variation of sample introduction memory and production of isobaric molecular interferences in the spectrometer's collision cell currently appear to be the ultimate limitation to better reproducibility. Comparative study of five different datasets from actual samples (bullets, international rock standards, carbonates, metamorphic minerals, and sulphide minerals) demonstrates that in most cases geological scatter of the sample exceeds the achieved analytical reproducibility. We observe good agreement between TIMS and MC-ICP-MS data for international rock standards but find that such comparison does not constitute the ultimate. test for the validity of the MC-ICP-MS technique. Two attempted isochrons resulted in geological scatter (in one case small) in excess of analytical reproducibility. However, in one case (leached Great Dyke sulphides) we obtained a true isochron (MSWD = 0.63) age of 2578.3 +/- 0.9 Ma, which is identical to and more precise than a recently published U-Pb zircon age (2579 3 Ma) for a Great Dyke websterite [Earth Planet. Sci. Lett. 180 (2000) 1-12]. Reproducibility of this age by means of an isochron we regard as a robust test of accuracy over a wide dynamic range. We show that reliable and accurate Pb-isotope data can be obtained by careful operation of second-generation MC-ICP magnetic sector mass spectrometers. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
This study compared an enzyme-linked immunosorbent assay (ELISA) to a liquid chromatography-tandem mass spectrometry (LC/MS/MS) technique for measurement of tacrolimus concentrations in adult kidney and liver transplant recipients, and investigated how assay choice influenced pharmacokinetic parameter estimates and drug dosage decisions. Tacrolimus concentrations measured by both ELISA and LC/MS/MS from 29 kidney (n = 98 samples) and 27 liver (n = 97 samples) transplant recipients were used to evaluate the performance of these methods in the clinical setting. Tacrolimus concentrations measured by the two techniques were compared via regression analysis. Population pharmacokinetic models were developed independently using ELISA and LC/MS/MS data from 76 kidney recipients. Derived kinetic parameters were used to formulate typical dosing regimens for concentration targeting. Dosage recommendations for the two assays were compared. The relation between LC/MS/MS and ELISA measurements was best described by the regression equation ELISA = 1.02 . (LC/MS/MS) + 0.14 in kidney recipients, and ELISA = 1.12 . (LC/MS/MS) - 0.87 in liver recipients. ELISA displayed less accuracy than LC/MS/MS at lower tacrolimus concentrations. Population pharmacokinetic models based on ELISA and LC/MS/MS data were similar with residual random errors of 4.1 ng/mL and 3.7 ng/mL, respectively. Assay choice gave rise to dosage prediction differences ranging from 0% to 30%. ELISA measurements of tacrolimus are not automatically interchangeable with LC/MS/MS values. Assay differences were greatest in adult liver recipients, probably reflecting periods of liver dysfunction and impaired biliary secretion of metabolites. While the majority of data collected in this study suggested assay differences in adult kidney recipients were minimal, findings of ELISA dosage underpredictions of up to 25% in the long term must be investigated further.
Resumo:
A barracuda implicated in ciguatera fish poisoning in Guadeloupe was estimated to have an overall flesh toxicity of 15 MUg/g using mouse bioassay. A lipid soluble extract was separated into two toxic fractions, FrA and FrB, on a LH20 Sephadex column eluted with dichloromethane/methanol (1:1). When intraperitoneal injected into mice, FrA provoked symptoms characteristic of slow-acting ciguatoxins, whereas FrB produced symptoms indicative of fast-acting toxins (FAT). High performance liquid chromatography/mass spectrometry/radio-ligand binding (HPLC/MS/RLB) analysis confirmed the two fractions were distinct, because only a weak overlap of some compounds was observed. HPLC/MS/RLB analysis revealed C-CTX-1 as the potent toxin present in FrA, and two coeluting active compounds at m/z 809.43 and 857.42 in FrB, all displaying the characteristic pattern of ion formation for hydroxy-polyethers. Other C-CTX congeners and putative hydroxy-polyether-like compounds were detected in both fractions, however, the RLB found them inactive. C-CTX-1 accounted for >90% of total toxicity in this barracuda and was confirmed to be a competitive inhibitor of brevetoxin binding to voltage-sensitive sodium channels (VSSCs) with a potency two-times lower than P-CTX-1. However, FAT active on VSSCs and
Resumo:
mais consumida no país, e proscrita pela Lei n° 11.343 de 23 de agosto de 2006 (chamada de “nova lei de droga”), onde todos os isômeros, sais, éteres e ésteres do ∆9-Tetrahidrocannabinol (THC), princípio ativo, foram proscritos. O método utilizado pela Polícia Civil do Estado do Espírito Santo para a identificação de cannabinóides é o teste colorimétrico, por meio de solução básica de Salt Fast Blue B, o qual apresenta resultados falsos negativos e falsos positivos. A técnica de espectrometria de massas de altíssima resolução e exatidão de massas (ESI(-)FTICR MS), permite detectar os principais cannabinóides na forma de molécula desprotonada, íon [M-H]-. Alguns íons que podem ser identificados são: [CBN - H]- de m/z 309 (CBN = cannabinol); [THC - H]- de m/z 313 (THC = tetrahidrocannabinol) e [CBD - H]- de m/z 313; [CBC - H]- de m/z 327 (CBC = cannabicromeno); [CBEA - H]- de m/z 345 (CBEA = ácido cannabielsóico); [CBNA - H]- de m/z 353 (CBNA = ácido cannabinólico); [THCA - H]- de m/z 357 (THCA = ácido tetrahidrocannabinólico); [8α, 11-Bis-hydroxy-∆9-THC-A - H]- de m/z 389); [∆9-THCA +C2H2O - H]- de m/z 357; e dímeros com m/z de 637, 653, 673, 681, 685 e 717. Foram encontrados adulterantes identificados como [M + N + H]+ : 491; [2M + N + H]+ : 819 e [3M + N + H]+ : 1147, onde M = OTHC (328Da C21H28O3) e N = Nicotina (162Da C10H14N2), além de lidocaína e cocaína. Ainda foram identificados alguns noncannabinóides como Cannflavino A e B e ácidos graxos como palmítico, oleico, linolênico e gama-linolênico nos extratos de sementes de Cannabis. Este estudo tem o objetivo de identificar o perfil químico de amostras de maconha, apreendidas pela Polícia Civil do Estado do Espírito Santo, por ESI(±)-FT-ICR MS.
Resumo:
A análise de hidrocarbonetos por técnicas de ionização a pressão atmosférica ou ambiente continua a ser um desafio na espectrometria de massas. Normalmente, a ionização ocorre através de mecanismos de protonação e desprotonação. Para isso, as moléculas de interesse devem apresentar um grupo básico ou ácido que proporcionem a geração de íons [M+H]+ ou [M-H]-. Para superar essa limitação, um método analítico simples, fácil, rápido e poderoso foi desenvolvido com sucesso, adaptado a partir da literatura, para ionizar saturado e insaturado, linear, ramificado, e hidrocarbonetos cíclicos, bem como hidrocarbonetos poliaromáticos e heteroaromáticos presentes em frações de hidrocarbonetos e de misturas de parafina/petróleo bruto utilizando ionização química à pressão atmosférica (APCI), favorecido pela utilização de solventes alifáticos de cadeia curta em um espectrômetro de massas FT-ICR. Entre os reagentes alifáticos estudados, isoctano proporcionou os melhores resultados quando comparado com outros solventes. Além disso, foram estudados outros interferentes do processo de ionização, como concentração da solução injetada e misturas parafina/óleo, que influenciavam desde o perfil dos espectros até as principais classes de compostos identificados. O método torna possível a ionização de hidrocarbonetos pela produção de íons [M -H]+ sem ocorrência de fragmentação.
Resumo:
Os organoestânicos, principalmente o tributilestanho (TBT), são contaminantes ambientais, utilizados principalmente em tintas anti-incrustantes para navios. Eles sofrem bioacumulação e podem ser encontrados em mamíferos, inclusive em seres humanos. A principal fonte de exposição é a ingestão de alimentos contaminados. Esse estudo possuiu como objetivo a determinação de estanho em tecidos de ratas expostas cronicamente a TBT utilizando espectrometria de massas com plasma acoplado indutivamente (ICP-MS). Ratas Wistar adultas foram usadas na experimentação, sendo divididas dois grupos: o grupo exposto a 100 ng kg-1 dia-1 de TBT por 15 dias e o grupo de referência que recebeu somente o veículo durante o mesmo período de exposição. Ao final da exposição, os animais foram sacrificados e coletados plasma, coração, rim, pulmão, fígado e ovário para análise. As amostras foram secas em estufa por 72 horas e pulverizadas. A determinação de estanho foi realizada por ICP-MS após a digestão ácida assistida por micro-ondas de uma amostra com aproximadamente 100 mg. O limite de detecção (LD) calculado foi 4,3 ng L-1, o que permite a determinação de estanho em amostras de tecidos de animais usados para experimentação. A exatidão foi verificada pela análise do material de referência certificado de urina, Seronorm Urine (54,6 ± 2,7 μg L-1), tendo como resultado 50,1 ± 3,8 μg L-1. A concentração de estanho foi determinada em amostras de plasma, coração, rim, pulmão, fígado e ovário do grupo exposto a TBT e do grupo controle. Houve diferença estatisticamente significativa entre os dois grupos para todas as amostras analisadas. As diferenças entre os grupos foram mais pronunciadas nas amostras de fígado e rim. Além disso, este estudo mostrou que a presença de estanho no organismo de ratas distribui-se pelos tecidos acarretando em alterações morfofisiológicas já descritas em ovários, coração e fígado