1000 resultados para PER assay


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A causal role has been inferred for ERBB2 overexpression in the etiology of breast cancer and other epithelial malignancies. The development of therapeutics that inhibit this tyrosine kinase cell surface receptor remains a high priority. This report describes the specific downregulation of ERBB2 protein and mRNA in the breast cancer cell line SK-BR-3 by using antisense DNA phosphorothioates. An approach was developed to examine antisense effects which allows simultaneous measurements of antisense dose and gene specific regulation on a per cell basis. A fluorescein isothiocyanate end-labeled tracer oligonucleotide was codelivered with antisense DNA followed by immunofluorescent staining for ERBB2 protein expression. Two-color flow cytometry measured the amount of both intracellular oligonucleotide and ERBB2 protein. In addition, populations of cells that received various doses of nucleic acids were physically separated and studied. In any given transfection, a 100-fold variation in oligonucleotide dosage was found. ERBB2 protein expression was reduced greater than 50%, but only in cells within a relatively narrow uptake range. Steady-state ERBB2 mRNA levels were selectively diminished, indicating a specific antisense effect. Cells receiving the optimal antisense dose were sorted and analyzed for cell cycle changes. After 2 days of ERBB2 suppression, breast cancer cells showed an accumulation in the G1 phase of the cell cycle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mutations in the p53 gene are implicated in the pathogenesis of half of all human tumors. We have developed a simple functional assay for p53 mutation in which human p53 expressed in Saccharomyces cerevisiae activates transcription of the ADE2 gene. Consequently, yeast colonies containing wild-type p53 are white and colonies containing mutant p53 are red. Since this assay tests the critical biological function of p53, it can distinguish inactivating mutations from functionally silent mutations. By combining this approach with gap repair techniques in which unpurified p53 reverse transcription-PCR products are cloned by homologous recombination in vivo it is possible to screen large numbers of samples and multiple clones per sample for biologically important mutations. This means that mutations can be detected in tumor specimens contaminated with large amounts of normal tissue. In addition, the assay detects temperature-sensitive mutants, which give pink colonies. We show here that this form of p53 functional assay can be used rapidly to detect germline mutations in blood samples, somatic mutations in tumors, and mutations in cell lines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to develop a simple, field-practical, and effective in vitro method for determining the sensitivity of fresh erythrocytic Plasmodium vivax isolates to a range of antimalarials. The method used is a modification of the standard World Health Organization (WHO) microtest for determination of P.falciparum drug sensitivity. The WHO method was modified by removing leukocytes and using a growth medium supplemented with AB(+) serum. We successfully carried out 34 in vitro drug assays on 39 P. vivax isolates collected from the Mae Sod malaria clinic, Tak Province, Thailand. The mean percentage of parasites maturing to schizonts (six or more merozoites) in control wells was 66.5% +/- 5.9% (standard deviation). This level of growth in the control wells enabled rapid microscopic determination (5 min per isolate per drug) of the MICs of chloroquine, dihydroartemisinin, WR238605 (tafenoquine), and sulfadoxine. P. vivax was relatively sensitive to chloroquine (MIC = 160 ng/ml, 50% inhibitory concentration [IC50] = 49.8 ng/ml) and dihydroartemisinin (MIC = 0.5 ng/ml, IC50 = 0.47 ng/ml). The poor response of P. vivax to both tafenoquine (MIC = 14,000 ng/ml, IC50 = 9,739 ng/ml) and sulfadoxine (MIC = 500,000 ng/ml, IC50 = 249,000 ng/ml) was due to the slow action of these drugs and the innate resistance of P. vivax to sulfadoxine. The in vitro assay developed in our study should be useful both for assessing the antimalarial sensitivity of P. vivax populations and for screening new antimalarials in the absence of long-term P. vivax cultures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Freshwater is extremely precious; but even more precious than freshwater is clean freshwater. From the time that 2/3 of our planet is covered in water, we have contaminated our globe with chemicals that have been used by industrial activities over the last century in a unprecedented way causing harm to humans and wildlife. We have to adopt a new scientific mindset in order to face this problem so to protect this important resource. The Water Framework Directive (European Parliament and the Council, 2000) is a milestone legislative document that transformed the way that water quality monitoring is undertaken across all Member States by introducing the Ecological and Chemical Status. A “good or higher” Ecological Status is expected to be achieved for all waterbodies in Europe by 2015. Yet, most of the European waterbodies, which are determined to be at risk, or of moderate to bad quality, further information will be required so that adequate remediation strategies can be implemented. To date, water quality evaluation is based on five biological components (phytoplankton, macrophytes and benthic algae, macroinvertebrates and fishes) and various hydromorphological and physicochemical elements. The evaluation of the chemical status is principally based on 33 priority substances and on 12 xenobiotics, considered as dangerous for the environment. This approach takes into account only a part of the numerous xenobiotics that can be present in surface waters and could not evidence all the possible causes of ecotoxicological stress that can act in a water section. The mixtures of toxic chemicals may constitute an ecological risk not predictable on the basis of the single component concentration. To improve water quality, sources of contamination and causes of ecological alterations need to be identified. On the other hand, the analysis of the community structure, which is the result of multiple processes, including hydrological constrains and physico-chemical stress, give back only a “photograph” of the actual status of a site without revealing causes and sources of the perturbation. A multidisciplinary approach, able to integrate the information obtained by different methods, such as community structure analysis and eco-genotoxicological studies, could help overcome some of the difficulties in properly identifying the different causes of stress in risk assessment. In synthesis, the river ecological status is the result of a combination of multiple pressures that, for management purposes and quality improvement, have to be disentangled from each other. To reduce actual uncertainty in risk assessment, methods that establish quantitative links between levels of contamination and community alterations are needed. The analysis of macrobenthic invertebrate community structure has been widely used to identify sites subjected to perturbation. Trait-based descriptors of community structure constitute a useful method in ecological risk assessment. The diagnostic capacity of freshwater biomonitoring could be improved by chronic sublethal toxicity testing of water and sediment samples. Requiring an exposure time that covers most of the species’ life cycle, chronic toxicity tests are able to reveal negative effects on life-history traits at contaminant concentrations well below the acute toxicity level. Furthermore, the responses of high-level endpoints (growth, fecundity, mortality) can be integrated in order to evaluate the impact on population’s dynamics, a highly relevant endpoint from the ecological point of view. To gain more accurate information about potential causes and consequences of environmental contamination, the evaluation of adverse effects at physiological, biochemical and genetic level is also needed. The use of different biomarkers and toxicity tests can give information about the sub-lethal and toxic load of environmental compartments. Biomarkers give essential information about the exposure to toxicants, such as endocrine disruptor compounds and genotoxic substances whose negative effects cannot be evidenced by using only high-level toxicological endpoints. The increasing presence of genotoxic pollutants in the environment has caused concern regarding the potential harmful effects of xenobiotics on human health, and interest on the development of new and more sensitive methods for the assessment of mutagenic and cancerogenic risk. Within the WFD, biomarkers and bioassays are regarded as important tools to gain lines of evidence for cause-effect relationship in ecological quality assessment. Despite the scientific community clearly addresses the advantages and necessity of an ecotoxicological approach within the ecological quality assessment, a recent review reports that, more than one decade after the publication of the WFD, only few studies have attempted to integrate ecological water status assessment and biological methods (namely biomarkers or bioassays). None of the fifteen reviewed studies included both biomarkers and bioassays. The integrated approach developed in this PhD Thesis comprises a set of laboratory bioassays (Daphnia magna acute and chronic toxicity tests, Comet Assay and FPG-Comet) newly-developed, modified tacking a cue from standardized existing protocols or applied for freshwater quality testing (ecotoxicological, genotoxicological and toxicogenomic assays), coupled with field investigations on macrobenthic community structures (SPEAR and EBI indexes). Together with the development of new bioassays with Daphnia magna, the feasibility of eco-genotoxicological testing of freshwater and sediment quality with Heterocypris incongruens was evaluated (Comet Assay and a protocol for chronic toxicity). However, the Comet Assay, although standardized, was not applied to freshwater samples due to the lack of sensitivity of this species observed after 24h of exposure to relatively high (and not environmentally relevant) concentrations of reference genotoxicants. Furthermore, this species demonstrated to be unsuitable also for chronic toxicity testing due to the difficult evaluation of fecundity as sub-lethal endpoint of exposure and complications due to its biology and behaviour. The study was applied to a pilot hydrographic sub-Basin, by selecting section subjected to different levels of anthropogenic pressure: this allowed us to establish the reference conditions, to select the most significant endpoints and to evaluate the coherence of the responses of the different lines of evidence (alteration of community structure, eco-genotoxicological responses, alteration of gene expression profiles) and, finally, the diagnostic capacity of the monitoring strategy. Significant correlations were found between the genotoxicological parameter Tail Intensity % (TI%) and macrobenthic community descriptors SPEAR (p<0.001) and EBI (p<0.05), between the genotoxicological parameter describing DNA oxidative stress (ΔTI%) and mean levels of nitrates (p<0.01) and between reproductive impairment (Failed Development % from D. magna chronic bioassays) and TI% (p<0.001) as well as EBI (p<0.001). While correlation among parameters demonstrates a general coherence in the response to increasing impacts, the concomitant ability of each single endpoint to be responsive to specific sources of stress is at the basis of the diagnostic capacity of the integrated approach as demonstrated by stations presenting a mismatch among the different lines of evidence. The chosen set of bioassays, as well as the selected endpoints, are not providing redundant indications on the water quality status but, on the contrary, are contributing with complementary pieces of information about the several stressors that insist simultaneously on a waterbody section providing this monitoring strategy with a solid diagnostic capacity. Our approach should provide opportunities for the integration of biological effects into monitoring programmes for surface water, especially in investigative monitoring. Moreover, it should provide a more realistic assessment of impact and exposure of aquatic organisms to contaminants. Finally this approach should provide an evaluation of drivers of change in biodiversity and its causalities on ecosystem function/services provision, that is the direct and indirect contributions to human well-being.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assays that assess cellular mediated immune responses performed under Good Clinical Laboratory Practice (GCLP) guidelines are required to provide specific and reproducible results. Defined validation procedures are required to establish the Standard Operating Procedure (SOP), include pass and fail criteria, as well as implement positivity criteria. However, little to no guidance is provided on how to perform longitudinal assessment of the key reagents utilized in the assay. Through the External Quality Assurance Program Oversight Laboratory (EQAPOL), an Interferon-gamma (IFN-γ) Enzyme-linked immunosorbent spot (ELISpot) assay proficiency testing program is administered. A limit of acceptable within site variability was estimated after six rounds of proficiency testing (PT). Previously, a PT send-out specific within site variability limit was calculated based on the dispersion (variance/mean) of the nine replicate wells of data. Now an overall 'dispersion limit' for the ELISpot PT program within site variability has been calculated as a dispersion of 3.3. The utility of this metric was assessed using a control sample to calculate the within (precision) and between (accuracy) experiment variability to determine if the dispersion limit could be applied to bridging studies (studies that assess lot-to-lot variations of key reagents) for comparing the accuracy of results with new lots to results with old lots. Finally, simulations were conducted to explore how this dispersion limit could provide guidance in the number of replicate wells needed for within and between experiment variability and the appropriate donor reactivity (number of antigen-specific cells) to be used for the evaluation of new reagents. Our bridging study simulations indicate using a minimum of six replicate wells of a control donor sample with reactivity of at least 150 spot forming cells per well is optimal. To determine significant lot-to-lot variations use the 3.3 dispersion limit for between and within experiment variability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Sepsis can lead to multiple organ failure and death. Timely and appropriate treatment can reduce in-hospital mortality and morbidity. Objectives: To determine the clinical effectiveness and cost-effectiveness of three tests [LightCycler SeptiFast Test MGRADE® (Roche Diagnostics, Risch-Rotkreuz, Switzerland); SepsiTest™ (Molzym Molecular Diagnostics, Bremen, Germany); and the IRIDICA BAC BSI assay (Abbott Diagnostics, Lake Forest, IL, USA)] for the rapid identification of bloodstream bacteria and fungi in patients with suspected sepsis compared with standard practice (blood culture with or without matrix-absorbed laser desorption/ionisation time-offlight mass spectrometry). Data sources: Thirteen electronic databases (including MEDLINE, EMBASE and The Cochrane Library) were searched from January 2006 to May 2015 and supplemented by hand-searching relevant articles. Review methods: A systematic review and meta-analysis of effectiveness studies were conducted. A review of published economic analyses was undertaken and a de novo health economic model was constructed. A decision tree was used to estimate the costs and quality-adjusted life-years (QALYs) associated with each test; all other parameters were estimated from published sources. The model was populated with evidence from the systematic review or individual studies, if this was considered more appropriate (base case 1). In a secondary analysis, estimates (based on experience and opinion) from seven clinicians regarding the benefits of earlier test results were sought (base case 2). A NHS and Personal Social Services perspective was taken, and costs and benefits were discounted at 3.5% per annum. Scenario analyses were used to assess uncertainty. Results: For the review of diagnostic test accuracy, 62 studies of varying methodological quality were included. A meta-analysis of 54 studies comparing SeptiFast with blood culture found that SeptiFast had an estimated summary specificity of 0.86 [95% credible interval (CrI) 0.84 to 0.89] and sensitivity of 0.65 (95% CrI 0.60 to 0.71). Four studies comparing SepsiTest with blood culture found that SepsiTest had an estimated summary specificity of 0.86 (95% CrI 0.78 to 0.92) and sensitivity of 0.48 (95% CrI 0.21 to 0.74), and four studies comparing IRIDICA with blood culture found that IRIDICA had an estimated summary specificity of 0.84 (95% CrI 0.71 to 0.92) and sensitivity of 0.81 (95% CrI 0.69 to 0.90). Owing to the deficiencies in study quality for all interventions, diagnostic accuracy data should be treated with caution. No randomised clinical trial evidence was identified that indicated that any of the tests significantly improved key patient outcomes, such as mortality or duration in an intensive care unit or hospital. Base case 1 estimated that none of the three tests provided a benefit to patients compared with standard practice and thus all tests were dominated. In contrast, in base case 2 it was estimated that all cost per QALY-gained values were below £20,000; the IRIDICA BAC BSI assay had the highest estimated incremental net benefit, but results from base case 2 should be treated with caution as these are not evidence based. Limitations: Robust data to accurately assess the clinical effectiveness and cost-effectiveness of the interventions are currently unavailable. Conclusions: The clinical effectiveness and cost-effectiveness of the interventions cannot be reliably determined with the current evidence base. Appropriate studies, which allow information from the tests to be implemented in clinical practice, are required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Styrene is a building-block of several compounds used in a wide array of materials and products. The most important human exposure to this substance occurs in industrial settings, especially among reinforced-plastics industry workers. The effect of occupational exposure to styrene on cytogenetics biomarkers has been previously reviewed with positive association observed for chromosomal aberrations, and inconclusive data for the micronucleus assay. Some limitations were noted in those studies, including inadequate exposure assessment and poor epidemiological design. Furthermore, in earlier studies micronuclei frequency was measured with protocols not as reliable as cytokinesis-block micronucleus (CBMN) assay. Aim of the present systematic review and meta-analysis is to investigate genomic instability and DNA damage as measured by the CBMN assay in lymphocytes of subjects exposed to styrene. A total of 11 studies published between 2004 and 2012 were included in the meta-analysis encompassing 479 styrene-exposed workers and 510 controls. The quality of each study was estimated by a quality scoring system which ranked studies according to the consideration of major confounders, exposure characterization, and technical parameters. An overall increase of micronuclei frequencies was found in styrene-exposure workers when compared to referents (meta-MR 1.34; 95% CI 1.18–1.52), with significant increases achieved in six individual studies. The consistency of results in individual studies, the independence of this result from major confounding factors and from the quality of the study strengthens the reliability of risk estimates and supports the use of the CBMN assay in monitoring genetic risk in styrene workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role that heparanase plays during metastasis and angiogenesis in tumors makes it an attractive target for cancer therapeutics. Despite this enzyme’s significance, most of the assays developed to measure its activity are complex. Moreover, they usually rely on labeling variable preparations of the natural substrate heparan sulfate, making comparisons across studies precarious. To overcome these problems, we have developed a convenient assay based on the cleavage of the synthetic heparin oligosaccharide fondaparinux. The assay measures the appearance of the disaccharide product of heparanase-catalyzed fondaparinux cleavage colorimetrically using the tetrazolium salt WST-1. Because this assay has a homogeneous substrate with a single point of cleavage, the kinetics of the enzyme can be reliably characterized, giving a Km of 46 μM and a kcat of 3.5 s−1 with fondaparinux as substrate. The inhibition of heparanase by the published inhibitor, PI-88, was also studied, and a Ki of 7.9 nM was determined. The simplicity and robustness of this method, should, not only greatly assist routine assay of heparanase activity but also could be adapted for high-throughput screening of compound libraries, with the data generated being directly comparable across studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A surface plasmon resonance-based solution affinity assay is described for measuring the Kd of binding of heparin/heparan sulfate-binding proteins with a variety of ligands. The assay involves the passage of a pre-equilibrated solution of protein and ligand over a sensor chip onto which heparin has been immobilised. Heparin sensor chips prepared by four different methods, including biotin–streptavidin affinity capture and direct covalent attachment to the chip surface, were successfully used in the assay and gave similar Kd values. The assay is applicable to a wide variety of heparin/HS-binding proteins of diverse structure and function (e.g., FGF-1, FGF-2, VEGF, IL-8, MCP-2, ATIII, PF4) and to ligands of varying molecular weight and degree of sulfation (e.g., heparin, PI-88, sucrose octasulfate, naphthalene trisulfonate) and is thus well suited for the rapid screening of ligands in drug discovery applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Influenza is commonly spread by infectious aerosols; however, detection of viruses in aerosols is not sensitive enough to confirm the characteristics of virus aerosols. The aim of this study was to develop an assay for respiratory viruses sufficiently sensitive to be used in epidemiological studies. Method: A two-step, nested real-time PCR assay was developed for MS2 bacteriophage, and for influenza A and B, parainfluenza 1 and human respiratory syncytial virus. Outer primer pairs were designed to nest each existing real-time PCR assay. The sensitivities of the nested real-time PCR assays were compared to those of existing real-time PCR assays. Both assays were applied in an aerosol study to compare their detection limits in air samples. Conclusions: The nested real-time PCR assays were found to be several logs more sensitive than the real-time PCR assays, with lower levels of virus detected at lower Ct values. The nested real-time PCR assay successfully detected MS2 in air samples, whereas the real-time assay did not. Significance and Impact of the Study: The sensitive assays for respiratory viruses will permit further research using air samples from naturally generated virus aerosols. This will inform current knowledge regarding the risks associated with the spread of viruses through aerosol transmission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insulin-like growth factor binding proteins (IGFBPs) are prime regulators of IGF-action in numerous cell types including the retinal pigment epithelium (RPE). The RPE performs several functions essential for vision, including growth factor secretion and waste removal via a phagocytic process mediated in part by vitronectin (Vn). In the course of studying the effects of IGFBPs on IGF-mediated VEGF secretion and Vn-mediated phagocytosis in the RPE cell line ARPE-19, we have discovered that these cells avidly ingest synthetic microspheres (2.0 μm diameter) coated with IGFBPs. Given the novelty of this finding and the established role for endocytosis in mediating IGFBP actions in other cell types, we have explored the potential role of candidate cell surface receptors. Moreover, we have examined the role of key IGFBP structural motifs, by comparing responses to three members of the IGFBP family (IGFBP-3, IGFBP-4 and IGFBP-5) which display overlapping variations in primary structure and glycosylation status. Coating of microspheres (FluoSpheres®, sulfate modified polystyrene filled with a fluorophore) was conducted at 37 °C for 1 h using 20 μg/mL of test protein, followed by extensive washing. Binding of proteins was confirmed using a microBCA assay. The negative control consisted of microspheres treated with 0.1% bovine serum albumin (BSA), and all test samples were post-treated with BSA in an effort to coat any remaining free protein binding sites, which might otherwise encourage non-specific interactions with the cell surface. Serum-starved cultures of ARPE-19 cells were incubated with microspheres for 24 h, using a ratio of approximately 100 microspheres per cell. Uptake of microspheres was quantified using a fluorometer and was confirmed visually by confocal fluorescence microscopy. The ARPE-19 cells displayed little affinity for BSA-treated microspheres, but avidly ingested large quantities of those pre-treated with Vn (ANOVA; p < 0.001). Strong responses were also observed towards recombinant formulations of non-glycosylated IGFBP-3, glycosylated IGFBP-3 and glycosylated IGFBP-5 (all p < 0.001), while glycosylated IGFBP-4 induced a relatively minor response (p < 0.05). The response to IGFBP-3 was unaffected in the presence of excess soluble IGFBP-3, IGF-I or Vn. Likewise, soluble IGFBP-3 did not induce uptake of BSA-treated microspheres. Antibodies to either the transferrin receptor or type 1 IGF-receptor displayed slight inhibitory effects on responses to IGFBPs and Vn. Heparin abolished responses to Vn, IGFBP-5 and non-glycosylated IGFBP-3, but only partially inhibited the response to glycosylated IGFBP-3. Our results demonstrate for the first time IGFBP-mediated endocytosis in ARPE-19 cells and suggest roles for the IGFBP-heparin-binding domain and glycosylation status. These findings have important implications for understanding the mechanisms of IGFBP actions on the RPE, and in particular suggest a role for IGFBP-endocytosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wide range of screening strategies have been employed to isolate antibodies and other proteins with specific attributes, including binding affinity, specificity, stability and improved expression. However, there remains no high-throughput system to screen for target-binding proteins in a mammalian, intracellular environment. Such a system would allow binding reagents to be isolated against intracellular clinical targets such as cell signalling proteins associated with tumour formation (p53, ras, cyclin E), proteins associated with neurodegenerative disorders (huntingtin, betaamyloid precursor protein), and various proteins crucial to viral replication (e.g. HIV-1 proteins such as Tat, Rev and Vif-1), which are difficult to screen by phage, ribosome or cell-surface display. This study used the β-lactamase protein complementation assay (PCA) as the display and selection component of a system for screening a protein library in the cytoplasm of HEK 293T cells. The colicin E7 (ColE7) and Immunity protein 7 (Imm7) *Escherichia coli* proteins were used as model interaction partners for developing the system. These proteins drove effective β-lactamase complementation, resulting in a signal-to-noise ratio (9:1 – 13:1) comparable to that of other β-lactamase PCAs described in the literature. The model Imm7-ColE7 interaction was then used to validate protocols for library screening. Single positive cells that harboured the Imm7 and ColE7 binding partners were identified and isolated using flow cytometric cell sorting in combination with the fluorescent β-lactamase substrate, CCF2/AM. A single-cell PCR was then used to amplify the Imm7 coding sequence directly from each sorted cell. With the screening system validated, it was then used to screen a protein library based the Imm7 scaffold against a proof-of-principle target. The wild-type Imm7 sequence, as well as mutants with wild-type residues in the ColE7- binding loop were enriched from the library after a single round of selection, which is consistent with other eukaryotic screening systems such as yeast and mammalian cell-surface display. In summary, this thesis describes a new technology for screening protein libraries in a mammalian, intracellular environment. This system has the potential to complement existing screening technologies by allowing access to intracellular proteins and expanding the range of targets available to the pharmaceutical industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have examined the associations between cancers and circulating 25-hydroxyvitamin D [25(OH)D], but little is known about the impact of different laboratory practices on 25(OH)D concentrations. We examined the potential impact of delayed blood centrifuging, choice of collection tube, and type of assay on 25(OH)D concentrations. Blood samples from 20 healthy volunteers underwent alternative laboratory procedures: four centrifuging times (2, 24, 72, and 96 h after blood draw); three types of collection tubes (red top serum tube, two different plasma anticoagulant tubes containing heparin or EDTA); and two types of assays (DiaSorin radioimmunoassay [RIA] and chemiluminescence immunoassay [CLIA/LIAISON®]). Log-transformed 25(OH)D concentrations were analyzed using the generalized estimating equations (GEE) linear regression models. We found no difference in 25(OH)D concentrations by centrifuging times or type of assay. There was some indication of a difference in 25(OH)D concentrations by tube type in CLIA/LIAISON®-assayed samples, with concentrations in heparinized plasma (geometric mean, 16.1 ng ml−1) higher than those in serum (geometric mean, 15.3 ng ml−1) (p = 0.01), but the difference was significant only after substantial centrifuging delays (96 h). Our study suggests no necessity for requiring immediate processing of blood samples after collection or for the choice of a tube type or assay.