968 resultados para Osteochondral defects


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Topological defects in foam, either isolated (disclinations and dislocations) or in pairs, affect the energy and stress, and play an important role in foam deformation. Surface Evolver simulations were performed on large finite clusters of bubbles. These allow us to evaluate the effect of the topology of the defects, and the distance between defects, on the energy and pressure of foam clusters of different sizes. The energy of such defects follows trends similar to known analytical results for a continuous medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invariant integrals are derived for nematic liquid crystals and applied to materials with small Ericksen number and topological defects. The nematic material is confined between two infinite plates located at y = -h and y = h (h is an element of R+) with a semi-infinite plate at y = 0 and x < 0. Planar and homeotropic strong anchoring boundary conditions to the director field are assumed at these two infinite and semi-infinite plates, respectively. Thus, a line disclination appears in the system which coincides with the z-axis. Analytical solutions to the director field in the neighbourhood of the singularity are obtained. However, these solutions depend on an arbitrary parameter. The nematic elastic force is thus evaluated from an invariant integral of the energy-momentum tensor around a closed surface which does not contain the singularity. This allows one to determine this parameter which is a function of the nematic cell thickness and the strength of the disclination. Analytical solutions are also deduced for the director field in the whole region using the conformal mapping method. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Excision of large dermatofibrosarcoma protuberans in the anterior aspect of the trunk often results in large surgical defects that frequently dictate the need for microsurgical reconstruction. However, this option is not always available. PRESENTATION OF CASE: The authors describe two patients with very large anterior trunk dermatofibrosarcoma protuberans: one in the epigastric region and the other in the hypogastric region. In the patient with the hypogastric tumor, a classical abdominoplasty flap associated with umbilical transposition was used to cover the skin defect after muscle and fascial plication, and placement of a polypropylene mesh. In the patient with the epigastric tumor, a synthetic mesh was also placed, and the skin and subcutaneous defect was reconstructed with a reverse abdominoplasty flap and two thoraco-epigastric flaps. In both cases, complete closure was possible without immediate or late complications. DISCUSSION: The local options described in this paper present several potential advantages compared to microsurgical reconstruction, namely they are easier and faster to perform and teach; they provide a good skin color and texture match; they are not associated with distant donor site morbidity; follow-up is usually less cumbersome; the post-operative hospital stay tends to be shorter; they are less costly; they are less prone to complete failure. CONCLUSION: The authors believe that these two patients clearly show that local flaps, although frequently neglected, continue to be valid options for reconstructing large anterior trunk defects, even in the current era of microsurgery enthusiasm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial septal defects are the third most common type of congenital heart disease. Included in this group of malformations are several types of atrial communications that allow shunting of blood between the systemic and the pulmonary circulations. Most children with isolated atrial septal defects are free of symptoms, but the rates of exercise intolerance, atrial tachyarrhythmias, right ventricular dysfunction, and pulmonary hypertension increase with advancing age and life expectancy is reduced in adults with untreated defects. The risk of development of pulmonary vascular disease, a potentially lethal complication, is higher in female patients and in older adults with untreated defects. Surgical closure is safe and effective and when done before age 25 years is associated with normal life expectancy. Transcatheter closure offers a less invasive alternative for patients with a secundum defect who fulfil anatomical and size criteria. In this Seminar we review the causes, anatomy, pathophysiology, treatment, and outcomes of atrial septal defects in children and adult patients in whom this defect is the primary cardiac anomaly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the consequences of the chronic use of systemic corticosteroids in children with juvenile rheumatoid arthritis by means of evaluating osteochondral effects depicted by magnetic resonance imaging. PATIENTS AND METHODS: We reviewed clinical and magnetic resonance imaging findings in 69 children (72 knees) with juvenile rheumatoid arthritis. Two groups were studied. Group I: 34 (49.3%) children had previous or current use of systemic corticotherapy (22 girls; 12 boys; mean age: 11.3 years; mean disease duration: 5.9 years; mean corticotherapy duration: 2.9 years; mean cumulative dose of previous corticosteroids: 5000 mg); Group II: 35 (50.7%) children had no previous use of corticosteroids (27 girls; 8 boys; mean age: 11.7 years; mean disease duration: 5.3 years). The groups were compared statistically. RESULTS: In the group that had received corticotherapy (Group I), osteochondral abnormalities were significantly correlated to long-standing disease (>3.5 years; p<0.001). This correlation was not found in the group that had no previous history of corticotherapy (Group II). No correlations were established between median dose of corticosteroids and magnetic resonance imaging findings. CONCLUSION: It is important to further investigate the long-term intra-articular effects of systemic corticotherapy to ensure that the side effects of the aggressive therapy will not be more harmful for the joints than the symptoms suffered over the natural course of the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioactive glass nanoparticles (BGNPs) promote an apatite surface layer in physiologic conditions that lead to a good interfacial bonding with bone.1 A strategy to induce bioactivity in non-bioactive polymeric biomaterials is to incorporate BGNPs in the polymer matrix. This combination creates a nanocomposite material with increased osteoconductive properties. Chitosan (CHT) is a polymer obtained by deacetylation of chitin and is biodegradable, non-toxic and biocompatible. The combination of CHT and the BGNPs aims at designing biocompatible spheres promoting the formation of a calcium phosphate layer at the nanocomposite surface, thus enhancing the osteoconductivity behaviour of the biomaterial. Shape memory polymers (SMP) are stimuli-responsive materials that offer mechanical and geometrical action triggered by an external stimulus.2 They can be deformed and fixed into a temporary shape which remains stable unless exposed to a proper stimulus that triggers recovery of their original shape. This advanced functionality makes such SMPs suitable to be implanted using minimally invasive surgery procedures. Regarding that, the inclusion of therapeutic molecules becomes attractive.  We propose the synthesis of shape memory bioactive nanocomposite spheres with drug release capability.3   1.  L. L. Hench, Am. Ceram. Soc. Bull., 1993, 72, 93-98. 2.  A. Lendlein and S. Kelch, Angew Chem Int Edit, 2002, 41, 2034-2057. 3.  Ã . J. Leite, S. G. Caridade and J. F. Mano, Journal of Non-Crystalline Solids (in Press)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the low-energy electronic transport across grain boundaries in graphene ribbons and infinite flakes. Using the recursive Green’s function method, we calculate the electronic transmission across different types of grain boundaries in graphene ribbons. We show results for the charge density distribution and the current flow along the ribbon. We study linear defects at various angles with the ribbon direction, as well as overlaps of two monolayer ribbon domains forming a bilayer region. For a class of extended defect lines with periodicity 3, an analytic approach is developed to study transport in infinite flakes. This class of extended grain boundaries is particularly interesting, since the K and K0 Dirac points are superposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Evaluation of the role of transesophageal echocardiography in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS: Patients were selected for percutaneous closure of ASD by transesophageal echocardiography (TEE), which was also used to monitor the procedure, helping to select the appropriate size of the Amplatzer device, to verify its position, and to access the immediate results of the procedure. During the follow-up, TEE was used to evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiac chamber diameters. RESULTS: Twenty-two (40%) of a total of 55 studied patients were selected. Thirteen underwent Amplatzer device implantation, eight are still waiting for it, and one preferred the conventional surgical treatment. All procedures were successful, which was mainly due to proper patient selection. Six (23%) patients acutely developed RS, which spontaneously disapeared at the three-month follow-up examination in three patients. There was a significant reduction in the right ventricle diastolic diameter, from 27mm (average) to 24mm and 20mm, one and three months after the procedure, respectively (p<0.0076). CONCLUSION: With the aid of TEE, percutaneous closure of ASD can be successfully, safely, and effectively performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the frequency and prevalence of congenital heart defects in a tertiary care center for children with heart diseases. METHODS: We carried out an epidemiological assessment of the first medical visit of 4,538 children in a pediatric hospital from January 1995 to December 1997. All patients with congenital heart defects had their diagnoses confirmed at least on echocardiography. The frequency and prevalence of the anomalies were computed according to the classification of sequential analysis. Age, weight, and sex were compared between the groups of healthy individuals and those with congenital heart defects after distribution according to the age group. RESULTS: Of all the children assessed, 2,017 (44.4%) were diagnosed with congenital heart disease, 201 (4.4%) with acquired heart disease, 52 (1.2%) with arrhythmias, and 2,268 (50%) were healthy children. Congenital heart diseases predominated in neonates and infants, corresponding to 71.5% of the cases. Weight and age were significantly lower in children with congenital heart defects. Ventricular septal defect was the most frequent acyanotic anomaly, and tetralogy of Fallot was the most frequent cyanotic anomaly. CONCLUSION: Children with congenital heart defects are mainly referred during the neonatal period and infancy with impairment in gaining weight. Ventricular septal defect is the most frequent heart defect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 ± 3.3mm, and 15.2 ± 3.8mm, respectively. The Qp/Qs ratio was 1.9 ± 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Las Enfermedades de Atesoramiento de Glucógeno (EAGs) también llamadas Glucogenosis comprenden un grupo de entidades causadas por una deficiencia enzimática específica relacionada con la vía de síntesis o degradación de esta macromolécula. La heterogeneidad fenotípica de los pacientes afectados dificulta la identificación de las diferentes variantes de EAG y por ende la correcta definición nosológica. En el Centro de Estudio de las Metabolopatías Congénitas, CEMECO, se fueron definiendo los diferentes tipos de Glucogenosis a través de una estrategia multidisciplinaria que integra distintos niveles de investigación clínica y complementaria, laboratorio metabólico especializado, enzimático, histomorfológico y de análisis molecular. Sin embargo, en algunos enfermos, entre los que se encuentran aquellos con defectos en el sistema de la fosforilasa hepática (EAG-VI y EAG-IX), la exacta definición nosológica aún no está resulta. La EAG-VI se refiere a un defecto en la fosforilasa hepática, enzima codificada por el gen PYGL, mientras que la EAG-IX es causada por un defecto genético en una de las subunidades de la fosforilasa b quinasa hepática codicadas por los genes PHKA2, PHKB y PHKG2, respectivamente. El objetivo del presente trabajo es propender a la definición nosológica de pacientes con defectos en el sistema de la fosforilasa mediante una estrategia de análisis molecular investigando los genes PYGL, PHKA2, PHKB y PHKG2. Los pacientes incluidos en este estudio deberán ser compatibles de padecer una EAG-VI o EAG-IX sobre la base de síntomas clínicos y hallazgos bioquímicos. La metodología incluirá la determinación de la enzima fosforilasa b quinasa en glóbulos rojos y dentro del análisis molecular la extracción de DNA genómico a partir de sangre entera para la amplificación por PCR de los exones más las uniones exon/intron de los genes PHKG2 y PYGL y la extracción de RNA total y obtención de cDNA para posterior amplificación de los cDNA PHKA2 y PHKB. Todos los fragmentos amplificados serán sometidos a análisis de secuencia de nucleótidos. Resultados esperados. Este trabajo, primero en Argentina, permitirá establecer las bases moleculares de los defectos del sistema de la fosforilasa hepática (EAG-VI y EAG-IX). El poder lograr este nivel de investigación traerá aparejado, una oferta integrativa en el vasto capítulo de las glucogenosis hepáticas, con extraordinaria significación en la práctica asistencial para el manejo, pronóstico y correspondiente asesoramiento genético. Hepatic glycogen storage diseases (GSDs) are a group of disorders produced by a deficiency in a specific protein involved in the metabolism of glycogen causing different types of GSDs. Phenotypic heterogeneity of affected patients difficult to identify the different GSD variants and therefore the correct definition of the disease. In the “Centro de Estudio de las Metabolopatías Congénitas”, CEMECO, were defined the different GSD types by a protocol which included complex gradual levels of clinical, biochemical, enzymatic and morphological investigation. However, in some patients, like those one with defects in the hepatic phosphorylase system (GSD-VI and GSD-IX) the exact definition of the disease has not yet been resolved. The GSD-VI is produced by a defect in the PYGL gen that encode the liver phosphorylase, while the GSD-IX is caused by a genetic defect in one of the Phosphorylase b kinase subunits, encoded by the PHKA2, PHKB and PHKG2 genes, respectively. The aim of the present study is to define the phosphorylase system defects in argentinian patients through a molecular strategy that involve the investigation of PYGL, PHKA2, PHKB and PHKG2 genes. Patients included in the present study must be compatible with a GSD-VI or GSD-IX on the bases of clinical symptoms and biochemical findings. The phosphorylase b kinase activity will be assay on in blood red cells. The molecular study will include genomic DNA extraction for the amplification of PHKG2 and PYGL genes and the total RNA extraction for amplification of the PHKA2 and PHKB cDNA by PCR. All PCR-amplified fragments will be subjected to direct nucleotide sequencing. This work, first in Argentina, will make possible to establish the molecular basis of the defects on the hepatic phosphorylase system (GSD-VI and GSD IX). To achieve this level of research will entail advance in the study of the hepatic glycogen storage disease, with extraordinary significance in the treatment, prognosis and the genetic counselling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Congenital heart defects (CHD) are the most prevalent group of structural abnormalities at birth and one of the main causes of infant morbidity and mortality. Studies have shown a contribution of the copy number variation in the genesis of cardiac malformations.Objectives:Investigate gene copy number variation (CNV) in children with conotruncal heart defect.Methods:Multiplex ligation-dependent probe amplification (MLPA) was performed in 39 patients with conotruncal heart defect. Clinical and laboratory assessments were conducted in all patients. The parents of the probands who presented abnormal findings were also investigated.Results:Gene copy number variation was detected in 7/39 patients: 22q11.2 deletion, 22q11.2 duplication, 15q11.2 duplication, 20p12.2 duplication, 19p deletion, 15q and 8p23.2 duplication with 10p12.31 duplication. The clinical characteristics were consistent with those reported in the literature associated with the encountered microdeletion/microduplication. None of these changes was inherited from the parents.Conclusions:Our results demonstrate that the technique of MLPA is useful in the investigation of microdeletions and microduplications in conotruncal congenital heart defects. Early diagnosis of the copy number variation in patients with congenital heart defect assists in the prevention of morbidity and decreased mortality in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractIn children with structural congenital heart disease (CHD), the effects of chronic ventricular pacing on diastolic function are not well known. On the other hand, the beneficial effect of septal pacing over apical pacing is still controversial.The aim of this study was to evaluate the influence of different right ventricular (RV) pacing site on left ventricular (LV) diastolic function in children with cardiac defects.Twenty-nine pediatric patients with complete atrioventricular block (CAVB) and CHD undergoing permanent pacing were prospectively studied. Pacing sites were RV apex (n = 16) and RV septum (n = 13). Echocardiographic assessment was performed before pacemaker implantation and after it, during a mean follow‑up of 4.9 years.Compared to RV septum, transmitral E-wave was significantly affected in RV apical pacing (95.38 ± 9.19 vs 83 ± 18.75, p = 0.038). Likewise, parameters at the lateral annular tissue Doppler imaging (TDI) were significantly affected in children paced at the RV apex. The E´ wave correlated inversely with TDI lateral myocardial performance index (Tei index) (R2= 0.9849, p ≤ 0.001). RV apex pacing (Odds ratio, 0.648; confidence interval, 0.067-0.652; p = 0.003) and TDI lateral Tei index (Odds ratio, 31.21; confidence interval, 54.6-177.4; p = 0.025) predicted significantly decreased LV diastolic function.Of the two sites studied, RV septum prevents pacing-induced reduction of LV diastolic function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.