144 resultados para Osmosis.
Resumo:
Verification testing of two model technologies in pilot scale to remove arsenic and antimony based on reverse osmosis and chemical coagulation/filtration systems was conducted in Spiro Tunnel Water Filtration Plant located in Park City, Utah, US. The source water was groundwater in abandoned silver mine, naturally contaminated by 60-80 ppb of arsenic and antimony below 10 ppb. This water represents one of the sources of drinking water for Park City and constitutes about 44% of the water supply. The failure to remove antimony efficiently by coagulation/filtration (only 4.4% removal rate) under design conditions is discussed in terms of the chemistry differences between Sb (III, V) and As (III, V). Removal of Sb(V) at pH > 7, using coagulation/filtration technology, requires much higher (50 to 80 times) concentration of iron (III) than As. The stronger adsorption of arsenate over a wider pH range can be explained by the fact that arsenic acid is tri-protic, whereas antimonic acid is monoprotic. This difference in properties of As(V) and Sb(V) makes antimony (V) more difficult to be efficiently removed in low concentrations of iron hydroxide and alkaline pH waters, especially in concentration of Sb < 10 ppb.
Resumo:
Desalination processes to remove dissolved salts from seawater or brackish water includes common industrial scale processes such as reverse osmosis, thermal processes (i.e. multi-stage flash, multiple-effect distillation) and mechanical vapour compression. These processes are very energy intensive. The Institute for Future Environments (IFE) has evaluated various alternative processes to accomplish desalination using renewable or sustainable energy sources. A new process - a solar, thermally driven distillation system . based on the principles of a solar still – has been examined. This work presents an initial evaluation of the process.
Resumo:
This paper reports a study of ion exchange (IX) as an alternative CSG water treatment to the widely used reverse osmosis (RO) desalination process. An IX pilot plant facility has been constructed and operated using both synthetic and real CSG water samples. Application of appropriate synthetic resin technology has proved the effectiveness of IX processes.
Resumo:
Currently, open circuit Bayer refineries pump seawater directly into their operations to neutralise the caustic fraction of the Bayer residue. The resulting supernatant has a reduced pH and is pumped back to the marine environment. This investigation has assessed modified seawater sources generated from different ion filtration processes to compare their relative capacities to neutralise bauxite residues. An assessment of the chemical stability of the neutralisation products, neutralisation efficiency, discharge water quality, bauxite residue composition, and associated economic benefits have been considered to determine the most preferable seawater filtration process based on implementation costs, savings to operations and environmental benefits. The mechanism of neutralisation for each technology was determined to be predominately due to the formation of Bayer hydrotalcite and calcium carbonate, however variations in neutralisation capacity and efficiencies have been observed. The neutralisation efficiency of each feed source has been found to be dependent on the concentration of magnesium, aluminium, calcium and carbonate. These studies have revealed that multiple neutralisation steps occur throughout the process. Environmental, economic and social advantages and disadvantages of the different filtration technologies have been explored to determine the most sustainable method for the neutralisation of bauxite residues. The relative degree of “green” associated with nanofiltered seawater and reverse osmosis filtered seawater are discussed.
Resumo:
Poly sodium acrylate (PSA)-coated Magnetic Nanoparticles (PSA-MNPs) were synthesized as smart osmotic draw agent (SMDA) for water desalination by forward osmosis (FO) process. The PSA-coated MNPs demonstrated significantly higher osmotic pressure (~ 30 fold) as well as high FO water flux (~ 2–3 fold) when compared to their polymer (polyelectrolyte) counterpart, even at a very low concentration of ~ 0.13 wt.% in the draw solution. The PSA polymer chain conformation – coiled to extended – demonstrates a significant impact on the availability of the polymer hydrophilic groups in solution which is the driving force to attain higher osmotic pressure and water flux. When an optimum concentration of the polymer was anchored to a NP surface, the polymer chains assume an extended open conformation making the functional hydrophilic groups available to attract water molecules. This in turn boosts the osmotic pressure and FO water flux of the PSA-MNP draw agents. The low concentration of the PSA-MNP osmotic agent and the associated high water flux enhances the cost-effectiveness of our proposed SMDA system. In addition, easier magnetic separation and regeneration of the SMDA also improves its usability making it efficient, cost-effective and environment-friendly.
Resumo:
Common to many types of water and wastewater is the presence of sodium ions which can be removed by desalination technologies, such as reverse osmosis and ion exchange. The focus of this investigation was ion exchange as it potentially offered several advantages compared to competing methods. The equilibrium and column behaviour of a strong acid cation (SAC) resin was examined for the removal of sodium ions from aqueous sodium chloride solutions of varying normality as well as a coal seam gas water sample. The influence of the bottle-point method to generate the sorption isotherms was evaluated and data interpreted with the Langmuir Vageler, Competitive Langmuir, Freundlich, and Dubinin-Astakhov models. With the constant concentration bottle point method, the predicted maximum exchange levels of sodium ions on the resin ranged from 61.7 to 67.5 g Na/kg resin. The general trend was that the lower the initial concentration of sodium ions in the solution, the lower the maximum capacity of the resin for sodium ions. In contrast, the constant mass bottle point method was found to be problematic in that the isotherm profiles may not be complete, if experimental parameters were not chosen carefully. Column studies supported the observations of the equilibrium studies, with maximum sodium loading of ca. 62.9 g Na/kg resin measured, which was in excellent agreement with the predictions of the data from the constant concentration bottle point method. Equilibria involving coal seam gas water were more complex due to the presence of sodium bicarbonate in solution, albeit the maximum loading capacity for sodium ions was in agreement with the results from the more simple sodium chloride solutions.
Resumo:
This work explored the applicability of electrocoagulation (EC) using aluminium electrodes for the removal of contaminants which can scale and foul reverse osmosis membranes from a coal seam (CS) water sample, predominantly comprising sodium chloride, and sodium bicarbonate. In general, the removal efficiency of species responsible for scaling and fouling was enhanced by increasing the applied current density/voltage and contact times (30–60 s) in the EC chamber. High removal efficiencies of species potentially responsible for scale formation in reverse osmosis units such as calcium (100%), magnesium (87.9%), strontium (99.3%), barium (100%) and silicates (98.3%) were achieved. Boron was more difficult to eliminate (13.3%) and this was postulated to be due to the elevated solution pH. Similarly, fluoride removal from solution (44%) was also inhibited by the presence of hydroxide ions in the pH range 9–10. Analysis of produced flocs suggested the dominant presence of relatively amorphous boehmite (AlOOH), albeit the formation of Al(OH)3 was not ruled out as the drying process employed may have converted aluminium hydroxide to aluminium oxyhydroxide species. Evidence for adsorption of contaminants on floc surface sites was determined from FTIR studies. The quantity of aluminium released during the electrocoagulation process was higher than the Faradaic amount which suggested that the high salt concentrations in the coal seam water had chemically reacted with the aluminium electrodes.
Resumo:
The Coal Seam Gas (CSG) industry in Australia has grown significantly in recent years. During the gas extraction process, water is also recovered which is brackish in character. In order to facilitate beneficial reuse of the water, the CSG industry has primarily invested in Reverse Osmosis (RO) as the primary method for associated water desalination. However, the presence of alkaline earth ions in the water combined with the inherent alkalinity of the water may result in RO membrane scaling. Consequently, weak acid cation (WAC) synthetic ion exchange resins were investigated as a potential solution to this potential problem. It was shown that resins were indeed highly efficient at treating single and multi-component solutions of alkaline earth ions. The interaction of the ions with the resin was found to be considerably more complex that previously reported.
Resumo:
Coal seam gas (CSG) is a growing industry in Queensland and represents a potential major employer and deliverer of financial prosperity for years to come. CSG is a natural gas composed primarily of methane and is found trapped underground in coal beds. During the gas extraction process, significant volumes of associated water are also produced. This associated water could be a valuable resource, however, the associated water comprises of various salt constituents that make it problematic for beneficial use. Consequently, there is a need to implement various water treatment strategies to purify the associated water to comply with Queensland’s strict guidelines and to mitigate environmental risks. The resultant brine is also of importance as ultimately it also has to be dealt with in an economical manner. In some ways it can be considered that the CSG industry does not face a water problem, as this has inherent value to society, but rather has a “salt issue” to solve. This study analyzes the options involved in both the water treatment and salt recovery processes. A brief overview of the constituents present in Queensland CS water is made to illustrate the challenges involved and a range of treatment technologies discussed. Water treatment technologies examined include clarification (ballasted flocculation, dissolved air flotation, electrocoagulation), membrane filtration (ultrafiltration), ion exchange softening and desalination (ion exchange, reverse osmosis desalination and capacitance deionization). In terms of brine management we highlighted reinjection, brine concentration ponds, membrane techniques (membrane distillation, forward osmosis), thermal methods, electrodialysis, electrodialysis reversal, bipolar membrane electrodialysis, wind assisted intensive evaporation, membrane crystallization, eutectic freeze crystallization and vapor compression. As an entirety this investigation is designed to be an important tool in developing CS water treatment management strategies for effective management in Queensland and worldwide.
Resumo:
Reverse osmosis is the dominant technology utilized for desalination of saline water produced during the extraction of coal seam gas. Alternatively, ion exchange is of interest due to potential cost advantages. However, there is limited information regarding the column performance of strong acid cation resin for removal of sodium ions from both model and actual coal seam water samples. In particular, the impact of bed depth, flow rate, and regeneration was not clear. Consequently, this study applied Bed Depth Service Time (BDST) models to reveal that increasing sodium ion concentration and flow rates diminished the time required for breakthrough to occur. The loading of sodium ions on fresh resin was calculated to be ca. 71.1 g Na/kg resin. Difficulties in regeneration of the resin using hydrochloric acid solutions were discovered, with 86% recovery of exchange sites observed. The maximum concentration of sodium ions in the regenerant brine was found to be 47,400 mg/L under the conditions employed. The volume of regenerant waste formed was 6.2% of the total volume of water treated. A coal seam water sample was found to load the resin with only 53.5 g Na/kg resin, which was consistent with not only the co-presence of more favoured ions such as calcium, magnesium, barium and strontium, but also inefficient regeneration of the resin prior to the coal seam water test.
Resumo:
Desalination is one of the most traditional processes to generate potable water. With the rise in demand for potable water and paucity of fresh water resources, this process has gained special importance. Conventional thermal desalination processes involves evaporative methods such as multi-stage flash and solar distils, which are found to be energy intensive, whereas reverse osmosis based systems have high operating and maintenance costs. The present work describes the Adsorption Desalination (AD) system, which is an emerging process of thermal desalination cum refrigeration capable of utilizing low grade heat easily obtainable from even non-concentrating type solar collectors. The system employs a combination of flash evaporation and thermal compression to generate cooling and desalinated water. The current study analyses the system dynamics of a 4-bed single stage silica-gel plus water based AD system. A lumped model is developed using conservation of energy and mass coupled with the kinetics of adsorption/desorption process. The constitutive equations for the system components viz. evaporator, adsorber and condenser, are solved and the performance of the system is evaluated for a single stage AD system at various condenser temperatures and cycle times to determine optimum operating conditions required for desalination and cooling. (C) 2013 P. Dutta. Published by Elsevier Ltd.
Resumo:
Increasing nitrate concentrations in ground water is deleterious to human health as ingestion of such water can cause methemoglobinemia in infants and even cancer in adults (desirable limit for nitrate as NO3 - 45 mg/L, IS code 10500-1991). Excess nitrate concentrations in ground water is contributed by reason being disposal of sewage and excessive use of fertilizers. Though numerous technologies such as reverse osmosis, ion exchange, electro-dialysis, permeable reactive barriers using zerovalent iron etc exists, nitrate removal continues to be one of challenging issue as nitrate ion is highly mobile within the soil strata. The tapping the denitrification potential of soil denitrifiers which are inherently available in the soil matrix is the most sustainable approach to mitigate accumulation of nitrate in ground water. The insitu denitrification of sand and bentonite enhanced sand (bentonite content = 5%) in presence of easily assimilable organic carbon such as ethanol was studied. Batch studies showed that nitrate reduction by sand follows first order kinetics with a rate constant 5.3x10(-2) hr(-1) and rate constant 4.3 x 10(-2) hr(-1) was obtained for bentonite-enhanced sand (BS) at 25 degrees C. Filter columns (height = 5 cm and diameter = 8.2 cm) were constructed using sand and bentonite-enhanced sand as filter media. The filtration rate through both the filter columns was maintained at average value of 2.60 cm/h. The nitrate removal rates through both the filter media was assessed for solution containing 22.6 mg NO3-N/L concentrations while keeping C/N mass ratio as 3. For sand filter column, the nitrate removal efficiency reached the average value of 97.6% after passing 50 pore volumes of the nitrate solution. For bentonite-enhanced sand filter column, the average nitrate removal efficiency was 83.5%. The time required for effective operation for sand filter bed was 100 hours, while bentonite-enhanced sand filter bed did not require any maturation period as that of sand filter bed for effective performance because the presence of micropores in bentonite increases the hydraulic retention time of the solution inside the filter bed.
Resumo:
Research has proven that Shoreline Erosion is caused by excess water contained within the shore face. This Research presents an opportunity to control erosion by managing the near shore water table. Our Research on Bogue Banks North Carolina suggests that our buildings and other impervious surfaces collect and concentrate water from storm rain runoff into the surface water table and within the critical beach front water exit point. Presently our Potable Fresh Water is supplied from deep wells located beneath an impervious layer of Marl. After our use, the Waste water is drained into the Surface Aquifer, the combined waste and storm rain water raises the Surface Aquifer water table and produces Erosion. The Deep Aquifers presently supplying our Potable Water have an unknown recharge rate, with increasing reports of Salt Water intrusion. We believe our Vital Fresh water supply system should be modified to supply Reverse Osmosis treatment plants from shallow wells. This will lower the Surface Water Table. These Shallow wells, either horizontal or vertical, might be located within the beach front, adjacent to high erosion risk properties. Beach Drains and Reverse Osmosis Water systems are new and proven technologies. By combining these technologies we can reduce or reverse Shore Erosion, ensure a safe Potable Water supply, reduce requirements for periodic beach nourishment, reduce taxes and protect our property well into the Future. (PDF contains 5 pages)
Resumo:
O objetivo deste trabalho foi investigar o desempenho de uma membrana comercial na remoção de um metal pesado (níquel) de efluentes sintéticos, por osmose inversa. Na primeira etapa foi realizada uma comparação com os resultados obtidos com soluções de alimentação contendo sais, como NaCl, NaNO3 e Ni(NO3)2.6 H2O, nas concentrações de 50, 100 e 200 ppm, e nas pressões de 10, 20 e 26 bar. Os resultados mostraram que a influência da concentração e da pressão aplicada ao sistema não afetaram as rejeições de forma significativa. Na segunda etapa, como os parâmetros não influíram significativamente na rejeição dos sais, optou-se, pela aplicação de uma pressão de operação de 10 bar, para avaliar a eficiência de remoção de níquel. A membrana utilizada, constituída de poliamida, modelo HR98PP e fornecida pela DOW/Filmtec, apresentou uma boa permeabilidade hidráulica. Os resultados mostraram que para todas as concentrações testadas, as rejeições de níquel ultrapassaram 96%, comprovando a boa seletividade deste tipo de membrana na rejeição do referido metal, com fluxos de permeado variando entre 4,78 e 5,55 L/h.m2 , sob pressão de operação de 10 bar. Para estudar o efeito do tamanho iônico na rejeição da membrana, o níquel foi complexado pela adição de um agente quelante na solução de alimentação. O agente escolhido foi o Na2EDTA, devido à formação de um complexo estável com o níquel e por ser um agente não prejudicial à saúde humana. Os resultados com adição de EDTA indicaram um aumento na rejeição de níquel, atingindo o índice máximo de 98,22 %, partindo-se de uma solução com 40,39 ppm de Ni2+, e confirmam que o processo de osmose inversa com a membrana HR98PP é altamente adequado para o tratamento de efluentes contendo níquel
Resumo:
O objetivo deste estudo foi analisar o desempenho de um sistema de captação e tratamento de água do rio Sarapuí, por meio de uma estação de tratamento composta por um sistema de pré-tratamento convencional, ligado a um sistema de separação por membranas de osmose inversa, no Município de Belford Roxo RJ, instalado para fornecer água de processo a instalações industriais. Foi verificado que a água captada encontra-se em condição bastante degradada e que a unidade de tratamento removeu, em média, 97% do teor dos poluentes presentes na água, enquadrando-a nos parâmetros requeridos pelo processo industrial. Foi possível comprovar que o processo de separação por osmose inversa pode ser utilizado em escala industrial, proporcionando ganhos econômicos consideráveis, além de evitar o consumo de água potável para fins de processos industriais e, ainda, contribuir para a retirada de carga orgânica de uma fonte degradada