900 resultados para Orbital fractures
Resumo:
Distal radius fractures stabilized by open reduction internal fixation (ORIF) have become increasingly common. There is currently no consensus on the optimal time to commence range of motion (ROM) exercises post-ORIF. A retrospective cohort review was conducted over a five-year period to compare wrist and forearm range of motion outcomes and number of therapy sessions between patients who commenced active ROM exercises within the first seven days and from day eight onward following ORIF of distal radius fractures. One hundred and twenty-one patient cases were identified. Clinical data, active ROM at initial and discharge therapy assessments, fracture type, surgical approaches, and number of therapy sessions attended were recorded. One hundred and seven (88.4%) cases had complete datasets. The early active ROM group (n = 37) commenced ROM a mean (SD) of 4.27 (1.8) days post-ORIF. The comparator group (n = 70) commenced ROM exercises 24.3 (13.6) days post-ORIF. No significant differences were identified between groups in ROM at initial or discharge assessments, or therapy sessions attended. The results from this study indicate that patients who commenced active ROM exercises an average of 24 days after surgery achieved comparable ROM outcomes with similar number of therapy sessions to those who commenced ROM exercises within the first week.
Resumo:
In most radicals the singly occupied molecular orbital (SOMO) is the highest-energy occupied molecular orbital (HOMO); however, in a small number of reported compounds this is not the case. In the present work we expand significantly the scope of this phenomenon, known as SOMO-HOMO energy-level conversion, by showing that it occurs in virtually any distonic radical anion that contains a sufficiently stabilized radical (aminoxyl, peroxyl, aminyl) non-pi-conjugated with a negative charge (carboxylate, phosphate, sulfate). Moreover, regular orbital order is restored on protonation of the anionic fragment, and hence the orbital configuration can be switched by pH. Most importantly, our theoretical and experimental results reveal a dramatically higher radical stability and proton acidity of such distonic radical anions. Changing radical stability by 3-4 orders of magnitude using pH-induced orbital conversion opens a variety of attractive industrial applications, including pH-switchable nitroxide-mediated polymerization, and it might be exploited in nature.
Resumo:
The aim of this research is to report initial experimental results and evaluation of a clinician-driven automated method that can address the issue of misdiagnosis from unstructured radiology reports. Timely diagnosis and reporting of patient symptoms in hospital emergency departments (ED) is a critical component of health services delivery. However, due to disperse information resources and vast amounts of manual processing of unstructured information, a point-of-care accurate diagnosis is often difficult. A rule-based method that considers the occurrence of clinician specified keywords related to radiological findings was developed to identify limb abnormalities, such as fractures. A dataset containing 99 narrative reports of radiological findings was sourced from a tertiary hospital. The rule-based method achieved an F-measure of 0.80 and an accuracy of 0.80. While our method achieves promising performance, a number of avenues for improvement were identified using advanced natural language processing (NLP) techniques.
Resumo:
Objective To develop and evaluate machine learning techniques that identify limb fractures and other abnormalities (e.g. dislocations) from radiology reports. Materials and Methods 99 free-text reports of limb radiology examinations were acquired from an Australian public hospital. Two clinicians were employed to identify fractures and abnormalities from the reports; a third senior clinician resolved disagreements. These assessors found that, of the 99 reports, 48 referred to fractures or abnormalities of limb structures. Automated methods were then used to extract features from these reports that could be useful for their automatic classification. The Naive Bayes classification algorithm and two implementations of the support vector machine algorithm were formally evaluated using cross-fold validation over the 99 reports. Result Results show that the Naive Bayes classifier accurately identifies fractures and other abnormalities from the radiology reports. These results were achieved when extracting stemmed token bigram and negation features, as well as using these features in combination with SNOMED CT concepts related to abnormalities and disorders. The latter feature has not been used in previous works that attempted classifying free-text radiology reports. Discussion Automated classification methods have proven effective at identifying fractures and other abnormalities from radiology reports (F-Measure up to 92.31%). Key to the success of these techniques are features such as stemmed token bigrams, negations, and SNOMED CT concepts associated with morphologic abnormalities and disorders. Conclusion This investigation shows early promising results and future work will further validate and strengthen the proposed approaches.
Resumo:
Background Timely diagnosis and reporting of patient symptoms in hospital emergency departments (ED) is a critical component of health services delivery. However, due to dispersed information resources and a vast amount of manual processing of unstructured information, accurate point-of-care diagnosis is often difficult. Aims The aim of this research is to report initial experimental evaluation of a clinician-informed automated method for the issue of initial misdiagnoses associated with delayed receipt of unstructured radiology reports. Method A method was developed that resembles clinical reasoning for identifying limb abnormalities. The method consists of a gazetteer of keywords related to radiological findings; the method classifies an X-ray report as abnormal if it contains evidence contained in the gazetteer. A set of 99 narrative reports of radiological findings was sourced from a tertiary hospital. Reports were manually assessed by two clinicians and discrepancies were validated by a third expert ED clinician; the final manual classification generated by the expert ED clinician was used as ground truth to empirically evaluate the approach. Results The automated method that attempts to individuate limb abnormalities by searching for keywords expressed by clinicians achieved an F-measure of 0.80 and an accuracy of 0.80. Conclusion While the automated clinician-driven method achieved promising performances, a number of avenues for improvement were identified using advanced natural language processing (NLP) and machine learning techniques.
Resumo:
The aim of this study was to assess the accuracy of placement of pelvic binders and to determine whether circumferential compression at the level of the greater trochanters is the best method of reducing a symphyseal diastasis. Patients were identified by a retrospective review of all pelvic radiographs performed at a military hospital over a period of 30 months. We analysed any pelvic radiograph on which the buckle of the pelvic binder was clearly visible. The patients were divided into groups according to the position of the buckle in relation to the greater trochanters: high, trochanteric or low. Reduction of the symphyseal diastasis was measured in a subgroup of patients with an open-book fracture, which consisted of an injury to the symphysis and disruption of the posterior pelvic arch (AO/OTA 61-B/C). We identified 172 radiographs with a visible pelvic binder. Five cases were excluded due to inadequate radiographs. In 83 (50%) the binder was positioned at the level of the greater trochanters. A high position was the most common site of inaccurate placement, occurring in 65 (39%). Seventeen patients were identified as a subgroup to assess the effect of the position of the binder on reduction of the diastasis. The mean gap was 2.8 times greater (mean difference 22 mm) in the high group compared with the trochanteric group (p < 0.01). Application of a pelvic binder above the level of the greater trochanters is common and is an inadequate method of reducing pelvic fractures and is likely to delay cardiovascular recovery in these seriously injured patients.
Resumo:
Introduction The risk for late periprosthetic fractures is higher in patients treated for a neck of femur fracture compared to those treated for osteoarthritis. It has been hypothesised that osteopenia and consequent decreased stiffness of the proximal femur are responsible for this. We investigated if a femoral component with a bigger body would increase the torque to failure in a biaxially loaded composite sawbone model. Method A biomechanical composite sawbone model was used. Two different body sizes (Exeter 44-1 vs 44-4) of a polished tapered cemented stem were implanted by an experienced surgeon, in 7 sawbones each and loaded at 40 deg/s internal rotation until failure. Torque to fracture and fracture energy were measured using a biaxial materials testing device (Instron 8874). Data are non-parametric and tested with Mann-Whitney U-test. Results The mean torque load to fracture was 154.1 NM (SD 4.4) for the 44-1 stem and 229 NM (SD10.9) for the 44-4 stem (p = 0.01). The mean fracture energy was 9.6 J (SD1.2) for the 44-1 stem and 17.2 J (SD2.0) for the 44-4 stem (p = 0.14). Conclusion the use of a large body polished tapered cemented stem for neck of femur fractures increases the torque to failure in a biomechanical model and therefore is likely to reduce late periprosthetic fracture risk in this vulnerable cohort.
In-hospital mortality rates after a cemented femoral component for displaced neck of femur fractures
Resumo:
Aim This prospective cohort study investigated whether the use of preoperative anticoagulants is an independent risk factor for the outcomes of surgical treatment of patients with a neck of femur fracture. Methods Data was obtained from a prospectively collected database. All patients admitted for a neck of femur fracture between Nov 2010 and Oct 2011 were included. This resulted in three hundred twenty-eight patients with 330 neck of femur fractures. Four groups were defined; patients preoperatively (i) on aspirin (n = 105); (ii) on clopidogrel (n = 28); (iii) on warfarin (n = 30), and; (iv) without any anticoagulation history (n = 167, the control group). The non-warfarin group included the aspirin group, clopidogrel group and the control group. Primary outcome was the in-hospital mortality. Secondary outcomes were the postoperative complications, return to theatre and length of stay. Results Thirteen in-hospital deaths were identified, 4 deaths in the aspirin group, 1 death in the clopidogrel group, 2 deaths in the warfarin group and 6 deaths in the control group. No significant difference in the mortality rates was found between the different groups. Also in the secondary outcomes, no significant difference was found between the four groups. A trend to a higher wound complication rate for the warfarin group was detected. Conclusion The use of clopidrogel or aspirin pre operatively is not an influence on short term patient outcome for patients with a neck of femur fracture. Surgical procedures should not be delayed to reverse their influence.
Resumo:
Objectives To determine the proportion of hip fracture patients who experience long-term disability and to re-estimate the resulting burden of disease associated with hip fractures in Australia in 2003. Methods A literature review of the functional outcome following a hip fracture (keywords: morbidity, treatment outcome, disability, quality of life, recovery of function, hip fractures, and femoral neck fractures) was carried out using PubMed and Ovid MEDLINE. Results A range of scales and outcome measures are used to evaluate recovery following a hip fracture. Based on the available evidence on restrictions in activities of daily living, 29% of hip fracture cases in the elderly do not reach their pre-fracture levels 1 year post-fracture. Those who do recover tend to reach their pre-fracture levels of functioning at around 6 months. These new assumptions result in 8251 years lived with disability for hip fractures in Australia in 2003, a 4.5-fold increase compared with the previous calculation based on Global Burden of Disease assumptions that only 5% of hip fractures lead to long-term disability and that the duration of short-term disability is just 51 days. Conclusions The original assumptions used in burden of disease studies grossly underestimate the long-term disability from hip fractures. The long-term consequences of other injuries may similarly have been underestimated and need to be re-examined. This has important implications for modelling the cost-effectiveness of preventive interventions where disability-adjusted life years are used as a measure of health outcome.
Resumo:
The prevalence of osteoporosis is expected to increase with the ageing of the world’s population. This article reviews the epidemiology, risk factors and health burden of osteoporosis. In the Global Burden of Disease (GBD) Study 2005, osteoporosis is studied as a risk factor for fracture by considering the bone-mineral-density (BMD) measurement as the continuous exposure variable. We have performed a systematic review seeking population-based studies with BMD data measured by dual-X-ray absorptiometry (DXA). The femoral neck was selected as the unique location and all values were converted into Hologic® to enable inclusion of worldwide data for analysis. Provisional results on mean BMD values for different world regions are shown in age breakdowns for males and females 50 years or over, as well as mean T-scores using the young, white, female reference of National Health and Nutrition Examination Survey (NHANES) III. Results show remarkable geographical differences and a time trend towards improvement of the BMD values in Asian and European populations.
Can larger-bodied cemented femoral components reduce periprosthetic fractures? A biomechanical study
Resumo:
Introduction: The risk for late periprosthetic femoral fractures is higher in patients treated for a neck of femur fracture compared to osteoarthritis. It has been hypothesised that osteopenia and consequent decreased stiffness of the proximal femur are responsible for this. We investigated whether a femoral component with a bigger body would increase the torque to failure in a biaxially loaded composite Sawbone model. Material and methods: A biomechanical bone analogue was used. Two different body sizes (Exeter 44-1 vs 44-4) of a polished tapered cemented femoral stem were implanted by an experienced surgeon in 7 bone analogues each and internally rotated at 40°/s until failure. Torque to fracture and fracture energy were measured using a biaxial materials testing device (Instron 8874, MI, USA). The data were non-parametric and therefore tested with the Mann-Whitney U-test. Results: The median torque to fracture was 156.7 Nm (IQR 19.7) for the 44-1 stem and 237.1 Nm (IQR 52.9) for the 44-4 stem (p=0.001). The median fracture energy was 8.5J (IQR 7.3) for the 44-1 stem and 19.5J (IQR 8.8) for the 44-4 stem (p=0.014). Conclusions: The use of a large body polished tapered cemented stems for neck of femur fractures increases the torque to failure in a biomechanical model and therefore is likely to reduce late periprosthetic fracture risk in this vulnerable cohort.
Resumo:
Background After being discharged from hospital following the acute management of a fragility fracture, older adults may re-present to hospital emergency departments in the post-discharge period. Early re-presentation to hospital, which includes hospital readmissions, and emergency department presentations without admission, may be considered undesirable for individuals, hospital institutions and society. The identification of modifiable risk factors for hospital re-representation following initial fracture management may prove useful for informing policy or practice initiatives that seek to minimise the need for older adults to re-present to hospital early after they have been discharged from their initial inpatient care. The purpose of this systematic review is to identify correlates of hospital re-presentation in older patients who have been discharged from hospital following clinical management of fragility fractures. Methods/Design The review will follow the PRISMA-P reporting guidelines for systematic reviews. Four electronic databases (Pubmed, CINAHL, Embase, and Scopus) will be searched. A suite of search terms will identify peer-reviewed articles that have examined the correlates of hospital re-presentation in older adults (mean age of 65 years or older) who have been discharged from hospital following treatment for fragility fractures. The Effective Public Health Practice Project Quality Assessment Tool for Quantitative Studies will be used to assess the quality of the studies. The strength of evidence will be assessed through best evidence synthesis. Clinical and methodological heterogeneity across studies are likely to impede meta-analyses. Discussion The best evidence synthesis will outline correlates of hospital re-presentations in this clinical group. This synthesis will take into account potential risks of bias for each study, while permitting inclusion of findings from a range of quantitative study designs. It is anticipated that findings from the review will be useful in identifying potentially modifiable risk factors that have relevance in policy, practice and research priorities to improve the management of patients with fragility fractures. Systematic Review Registration PROSPERO CRD42015019379
Resumo:
Graphitic like layered materials exhibit intriguing electronic structures and thus the search for new types of two-dimensional (2D) monolayer materials is of great interest for developing novel nano-devices. By using density functional theory (DFT) method, here we for the first time investigate the structure, stability, electronic and optical properties of monolayer lead iodide (PbI2). The stability of PbI2 monolayer is first confirmed by phonon dispersion calculation. Compared to the calculation using generalized gradient approximation, screened hybrid functional and spin–orbit coupling effects can not only predicts an accurate bandgap (2.63 eV), but also the correct position of valence and conduction band edges. The biaxial strain can tune its bandgap size in a wide range from 1 eV to 3 eV, which can be understood by the strain induced uniformly change of electric field between Pb and I atomic layer. The calculated imaginary part of the dielectric function of 2D graphene/PbI2 van der Waals type hetero-structure shows significant red shift of absorption edge compared to that of a pure monolayer PbI2. Our findings highlight a new interesting 2D material with potential applications in nanoelectronics and optoelectronics.
Resumo:
Objective The Nintendo Wii Fit integrates virtual gaming with body movement, and may be suitable as an adjunct to conventional physiotherapy following lower limb fractures. This study examined the feasibility and safety of using the Wii Fit as an adjunct to outpatient physiotherapy following lower limb fractures, and reports sample size considerations for an appropriately powered randomised trial. Methodology Ambulatory patients receiving physiotherapy following a lower limb fracture participated in this study (n = 18). All participants received usual care (individual physiotherapy). The first nine participants also used the Wii Fit under the supervision of their treating clinician as an adjunct to usual care. Adverse events, fracture malunion or exacerbation of symptoms were recorded. Pain, balance and patient-reported function were assessed at baseline and discharge from physiotherapy. Results No adverse events were attributed to either the usual care physiotherapy or Wii Fit intervention for any patient. Overall, 15 (83%) participants completed both assessments and interventions as scheduled. For 80% power in a clinical trial, the number of complete datasets required in each group to detect a small, medium or large effect of the Wii Fit at a post-intervention assessment was calculated at 175, 63 and 25, respectively. Conclusions The Nintendo Wii Fit was safe and feasible as an adjunct to ambulatory physiotherapy in this sample. When considering a likely small effect size and the 17% dropout rate observed in this study, 211 participants would be required in each clinical trial group. A larger effect size or multiple repeated measures design would require fewer participants.