896 resultados para Non-contact


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Wheel-rail rolling contact at railhead edge, such as a gap in an insulated rail joint, is a complex problem; there are only limited analytical, numerical and experimental studies available on this problem in the academic literature. This paper describes experimental and numerical investigations of railhead strains in the vicinity of the edge under the contact of a loaded wheel. A full-scale test rig was developed to cyclically apply wheel/rail rolling contact load to the edge zone of the railhead. An image analysis technique was employed to determine the railhead vertical, lateral and shear strain components. The vertical strains determined using the image analysis method have been validated with the strain gauge measurements and used for the calibration of a 3D nonlinear Finite Element Model (FEM) that simulates the wheel/rail contact at the railhead edge and use suitable boundary conditions commensurate to the experimental setup. The FEM was then used to determine other states of strains.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: This study investigated the influence of injury cause, contact-sport participation, and prior knowledge of mild traumatic brain injury (mTBI) on injury beliefs and chronic symptom expectations of mTBI. Method: A total of 185 non-contact-sport players (non-CSPs) and 59 contact-sport players (CSPs) with no history of mTBI were randomly allocated to one of two conditions in which they read either a vignette depicting a sport-related mTBI (mTBIsport) or a motor-vehicle-accident-related mTBI (mTBIMVA). The vignettes were otherwise standardized to convey the same injury parameters (e.g., duration of loss of consciousness). After reading a vignette, participants reported their injury beliefs (i.e., perceptions of injury undesirability, chronicity, and consequences) and their expectations of chronic postconcussion syndrome (PCS) and posttraumatic stress disorder (PTSD) symptoms. Results: Non-CSPs held significantly more negative beliefs and expected greater PTSD symptomatology and greater PCS affective symptomatology from an mTBIMVA vignette thann mTBIsport vignette, but this difference was not found for CSPs. Unlike CSPs, non-CSPs who personally knew someone who had sustained an mTBI expected significantly less PCS symptomatology than those who did not. Despite these different results for non-CSPs and CSPs, overall, contact-sport participation did not significantly affect injury beliefs and symptom expectations from an mTBIsport. Conclusions: Expectations of persistent problems after an mTBI are influenced by factors such as injury cause even when injury parameters are held constant. Personal knowledge of mTBI, but not contact sport participation, may account for some variability in mTBI beliefs and expectations. These factors require consideration when assessing mTBI outcome.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Rail joints are provided with a gap to account for thermal movement and to maintain electrical insulation for the control of signals and/or broken rail detection circuits. The gap in the rail joint is regarded as a source of significant problems for the rail industry since it leads to a very short rail service life compared with other track components due to the various, and difficult to predict, failure modes – thus increasing the risk for train operations. Many attempts to improve the life of rail joints have led to a large number of patents around the world; notable attempts include strengthening through larger-sized joint bars, an increased number of bolts and the use of high yield materials. Unfortunately, no design to date has shown the ability to prolong the life of the rail joints to values close to those for continuously welded rail (CWR). This paper reports the results of a fundamental study that has revealed that the wheel contact at the free edge of the railhead is a major problem since it generates a singularity in the contact pressure and railhead stresses. A design was therefore developed using an optimisation framework that prevents wheel contact at the railhead edge. Finite element modelling of the design has shown that the contact pressure and railhead stress singularities are eliminated, thus increasing the potential to work as effectively as a CWR that does not have a geometric gap. An experimental validation of the finite element results is presented through an innovative non-contact measurement of strains. Some practical issues related to grinding rails to the optimal design are also discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Methods of diagnosis in Biomedical applications can be broadly divided into contact and non-contact based methods. So far, ultrasound based methods have been found to be most favorable for non-contact, non-invasive diagnosis, especially in the case of tissue stiffness analysis. We report here, the fabrication and characterization details of a new contact based transducer system for qualitative determination of the stiffnesses of non-piezoelectric substrates using the phenomenon of Surface Acoustic Waves (SAW). Preliminary trials to study the functionality of this system were carried out on various metallic and non-metallic substrates, and the results were found to be satisfactory. To confirm the suitability of this system for biomedical applications, similar trials have been conducted on tissue mimicking phantoms with varying degrees of stiffness.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Infrared thermography is a non-invasive technique that measures mid to long-wave infrared radiation emanating from all objects and converts this to temperature. As an imaging technique, the value of modern infrared thermography is its ability to produce a digitized image or high speed video rendering a thermal map of the scene in false colour. Since temperature is an important environmental parameter influencing animal physiology and metabolic heat production an energetically expensive process, measuring temperature and energy exchange in animals is critical to understanding physiology, especially under field conditions. As a non-contact approach, infrared thermography provides a non-invasive complement to physiological data gathering. One caveat, however, is that only surface temperatures are measured, which guides much research to those thermal events occurring at the skin and insulating regions of the body. As an imaging technique, infrared thermal imaging is also subject to certain uncertainties that require physical modeling, which is typically done via built-in software approaches. Infrared thermal imaging has enabled different insights into the comparative physiology of phenomena ranging from thermogenesis, peripheral blood flow adjustments, evaporative cooling, and to respiratory physiology. In this review, I provide background and guidelines for the use of thermal imaging, primarily aimed at field physiologists and biologists interested in thermal biology. I also discuss some of the better known approaches and discoveries revealed from using thermal imaging with the objective of encouraging more quantitative assessment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Non-destructive testing (NDT) is the use of non-invasive techniques to determine the integrity of a material, component, or structure. Engineers and scientists use NDT in a variety of applications, including medical imaging, materials analysis, and process control.Photothermal beam deflection technique is one of the most promising NDT technologies. Tremendous R&D effort has been made for improving the efficiency and simplicity of this technique. It is a popular technique because it can probe surfaces irrespective of the size of the sample and its surroundings. This technique has been used to characterize several semiconductor materials, because of its non-destructive and non-contact evaluation strategy. Its application further extends to analysis of wide variety of materials. Instrumentation of a NDT technique is very crucial for any material analysis. Chapter two explores the various excitation sources, source modulation techniques, detection and signal processing schemes currently practised. The features of the experimental arrangement including the steps for alignment, automation, data acquisition and data analysis are explained giving due importance to details.Theoretical studies form the backbone of photothermal techniques. The outcome of a theoretical work is the foundation of an application.The reliability of the theoretical model developed and used is proven from the studies done on crystalline.The technique is applied for analysis of transport properties such as thermal diffusivity, mobility, surface recombination velocity and minority carrier life time of the material and thermal imaging of solar cell absorber layer materials like CuInS2, CuInSe2 and SnS thin films.analysis of In2S3 thin films, which are used as buffer layer material in solar cells. The various influences of film composition, chlorine and silver incorporation in this material is brought out from the measurement of transport properties and analysis of sub band gap levels.The application of photothermal deflection technique for characterization of solar cells is a relatively new area that requires considerable attention.The application of photothermal deflection technique for characterization of solar cells is a relatively new area that requires considerable attention. Chapter six thus elucidates the theoretical aspects of application of photothermal techniques for solar cell analysis. The experimental design and method for determination of solar cell efficiency, optimum load resistance and series resistance with results from the analysis of CuInS2/In2S3 based solar cell forms the skeleton of this chapter.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Quality control on fruits requires reliable methods, able to assess with reasonable accuracy and possibly in a non-destructive way their physical and chemical characteristics. More specifically, a decreased firmness indicates the presence of damage or defects in the fruit or else that the fruit has exceeded its “best before date”, becoming unsuitable for consumption. In high-value exotic fruits, such as mangoes, where firmness cannot be easily measured from a simple observation of texture, colour changes and unevenness of fruits surface, the use of non-destructive techniques is highly recommendable. In particular, the application of Laser vibrometry, based on the Doppler effect, a non-contact technique sensitive to differences in displacements inferior to the nanometre, appears ideal for a possible on-line control on food. Previous results indicated that a phase shift can be in a repeatable way associated with the presence of damage on the fruit, whilst a decreased firmness results in significant differences in the displacement of the fruits under the same excitation signal. In this work, frequency ranges for quality control via the application of a sound chirp are suggested, based on the measurement of the signal coherence. The variations of the average vibration spectrum of a grid of points, or of point-by-point signal velocity allows the go-no go recognition of “firm” and “over-ripe” fruits, with notable success in the particular case of mangoes. The future exploitation of this work will include the application of this method to allow on-line control during conveyor belt distribution of fruits.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Hand hygiene is critical in the healthcare setting and it is believed that methicillin-resistant Staphylococcus aureus (MRSA), for example, is transmitted from patient to patient largely via the hands of health professionals. A study has been carried out at a large teaching hospital to estimate how often the gloves of a healthcare worker are contaminated with MRSA after contact with a colonized patient. The effectiveness of handwashing procedures to decontaminate the health professionals' hands was also investigated, together with how well different healthcare professional groups complied with handwashing procedures. The study showed that about 17% (9-25%) of contacts between a healthcare worker and a MRSA-colonized patient results in transmission of MRSA from a patient to the gloves of a healthcare worker. Different health professional groups have different rates of compliance with infection control procedures. Non-contact staff (cleaners, food services) had the shortest handwashing times. In this study, glove use compliance rates were 75% or above in all healthcare worker groups except doctors whose compliance was only 27%. (C) 2004 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Contact lenses have become a popular method of vision correction for millions of people globally. As with all devices designed for use within the body, interactions occur between the implanted material and the surrounding biological fluid. A common complaint of lens wearers is that they often experience symptoms of dry eye whilst wearing lenses. This sensation is often heightened towards the end of the day. Through the course of this study, various analytical techniques have been utilised including one dimensional electrophoresis and Western Blotting to study the protein profiles of tear samples. By studying the tears of non-contact lens wearers, it was possible to analyse what could be considered normal, healthy, individuals. A clinical study was also undertaken which followed a population of individuals from the neophyte stage to one whereby they were accustomed lens wearers. Tears were monitored at regular intervals throughout the course of this study and worn contact lenses were also analysed for proteins that had been deposited both on and within the lens. Contact lenses disrupt the tear film in a physical manner by their very presence. They are also thought to cause the normal protein profile to deviate from what would be considered normal. The tear film deposits proteins and lipids onto and within the lens. The lens may therefore be depriving the tear film of certain necessary components. The ultimate aim of this thesis was to discover how, and to what extent, lenses affected tear proteins and if there were any proteins in the tear fluid that had the potential to be used as biochemical markers. Should this be achievable it may be possible to identify those individuals who were more likely to become intolerant lens wearers. This study followed the changes taking place to the tear film as an effect of wearing contact lenses. Twenty-eight patients wore two different types of silicone hydrogel lenses in both a daily wear and a continuous wear regime. The tear protein profiles of the lens-wearers were compared with a control group of non-lens wearing individuals. The considerable amount of data that was generated enabled the clearly observable changes to the four main tear proteins to be monitored.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The thesis investigates the ocular response to silicone-hydrogel (SiH) contact lens wear, a relatively new contact lens material that has a higher modulus of rigidity and different surface coating than used in conventional hydrogel materials. The properties of SiH materials differ significantly from conventional hydrogels and, using subjective and objective means of assessment, the thesis examines how these properties affect reflection and biometry, ocular physiology, tear film characteristics, symptomatology, adverse events and complications. A range of standard and newly designed investigative techniques were employed, and latter involving novel imaging techniques, for the objective assessment of physiological changes which occur with contact lens wear. The study is the first to combine these techniques with biochemical analyses of the tear film composition. Forty-seven subjects were fitted with SiH lenses and randomly allocated to one of the two materials currently on the market (Lotrafilcon A or Balafilcon A) on an either daily or continuous wear basis. An additional control group of 14 age-matched non-contact lens wearers were monitored over the same period. Measurements were taken before and 1, 3, 6, 12 and 18 months after initial fitting. The findings reported in this thesis will enable contact lens practitioners and manufacturers to understand further the optical, physiological and biochemical nature of the ocular response to SiH contact lenses and hence facilitate the development of this important generation of contact lens material.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The limbal vascular response to extended contact lens wear was examined in a group comparative study initially intended to last eighteen months. After six months all patients wearing contact lenses had presented with micro-epithelial cysts. This unanticipated occurrence of the micro-epithelial-cysts necessitated termination of the study, and limited the quantity of data collected. However, sufficient results were available to allow a limited description of •the vascular response to this form of contact lens wear. Interpretations of the date collected ore discussed in relation to suggested vasostimulating factors in the cornea. The micro-epithelial cysts observed after extended wear were classified and their rate of recovery recorded. A further clinical study was undertaken to observe cysts in both contact lens - and non contact lens-wearing eyes. Cysts were observed in every category of patient, although the characteristic patterns varied. These observations of micro-epithelial cysts are discussed with respect to the aetiopathogeneses of corneal epithelial cystic disorders. Subsequently, attempts were made to induce cysts in rabbit corneae by extended contact lens wear. Clinical observations revealed cyst-like appearances. Histological sections did not contain cysts but did exhibit signs characteristic •of cystic disorders of the corneal epithelium. In general, the results from the study indicate that extended wear is subjectively acceptable to contact lens wearers. However, the objective findings of significant vascular changes, micro-epithelial cysts and cases of acute red eye response cast considerable doubt on the recommendation of extended wear contact lenses for purely cosmetic applications.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Contact lenses seem to be the ideal method of vision correction for ametropic people who participate in sporting activities. This thesis sets out to evaluate the viewpoint of the optometric professional and that of the patient on the use of contact lenses in sport and to establish if education is needed within this area. It also aims to provide some scientific evidence on the effect of exercise on the physiology of the cornea with and without contact lenses. Silicone hydrogel contact lenses have previously been suggested to impede heat dissipation from the cornea compared to mid water hydrogels. This was further demonstrated with exercise. The physiological integrity of the cornea is dependant on the amount of oxygen available to its surfaces. Contact lenses can disrupt the diffusion of oxygen to the cornea. Previous methods of measuring the oxygen consumption of the cornea have been limited by their invasive nature and assessment of only a small surface area of the cornea. They are not suitable to measure corneal oxygen consumption during exercise with and without contact lenses. A new method needed to be established. This was achieved by designing a novel method by the use of an oxygen sensor inside an airtight goggle using dynamic quenching of luminescence method. This established a non-contact way of measuring the effect oxygen uptake with and without contact lenses in vivo, allowing the contact lens to be undisturbed in their natural environment. The new method differentiated between the closed-eye and the open-eye condition with a good within-visit repeatability. It also illustrated that the cornea utilises oxygen at a faster rate during controlled aerobic exercise at moderate intensity. New contact lenses are available specifically for sport, these claim to reduce glare and increase contrast for daylight outdoor sports. However, visual benefits of these types of contact lenses cannot be measured easily in an indoor clinical environment, such as the optometric practice. To demonstrate any potential benefits of these lenses emulation of them should be conducted outdoors.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: To determine the dynamic emitted temperature changes of the anterior eye during and immediately after wearing different materials and modalities of soft contact lenses. Method: A dynamic, non-contact infrared camera (Thermo-Tracer TH7102MX, NEC San-ei) was used to record the ocular surface temperature (OST) in 48 subjects (mean age 21.7 ± 1.9 years) wearing: lotrafilcon-A contact lenses on a daily wear (LDW; n = 8) or continuous wear (LCW; n = 8) basis; balafilcon-A contact lenses on a daily wear (BDW; n = 8) or continuous wear (BCW; n = 8) basis; etafilcon-A contact lenses on a daily disposable regimen (EDW; n = 8); and no lenses (controls; n = 8). OST was measured continuously five times, for 8 s after a blink, following a minimum of 2 h wear and immediately following lens removal. Absolute temperature, changes in temperature post-blink and the dynamics of temperature changes were calculated. Results: OST immediately following contact lens wear was significantly greater compared to non-lens wearers (37.1 ± 1.7 °C versus 35.0 ± 1.1 °C; p < 0.005), predominantly in the LCW group (38.6 ± 1.0 °C; p < 0.0001). Lens surface temperature was highly correlated (r = 0.97) to, but lower than OST (by -0.62 ± 0.3 °C). There was no difference with modality of wear (DW 37.5 ± 1.6 °C versus CW 37.8 ± 1.9 °C; p = 0.63), but significant differences were found between etafilcon A and silicone hydrogel lens materials (35.3 ± 1.1 °C versus 37.5 ± 1.5 °C; p < 0.0005). Ocular surface cooling following a blink was not significantly affected by contact lens wear with (p = 0.07) or without (p = 0.47) lenses in situ. Conclusions: Ocular surface temperature is greater with hydrogel and greater still with silicone hydrogel contact lenses in situ, regardless of modality of wear. The effect is likely to be due to the thermal transmission properties of a contact lens. © 2004 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ABSTRACT: Neuropathy is a cause of significant disability in patients with Fabry disease, yet its diagnosis is difficult. In this study we compared the novel noninvasive techniques of corneal confocal microscopy (CCM) to quantify small-fiber pathology, and non-contact corneal esthesiometry (NCCA) to quantify loss of corneal sensation, with established tests of neuropathy in patients with Fabry disease. Ten heterozygous females with Fabry disease not on enzyme replacement therapy (ERT), 6 heterozygous females, 6 hemizygous males on ERT, and 14 age-matched, healthy volunteers underwent detailed quantification of neuropathic symptoms, neurological deficits, neurophysiology, quantitative sensory testing (QST), NCCA, and CCM. All patients with Fabry disease had significant neuropathic symptoms and an elevated Mainz score. Peroneal nerve amplitude was reduced in all patients and vibration perception threshold was elevated in both male and female patients on ERT. Cold sensation (CS) threshold was significantly reduced in both male and female patients on ERT (P < 0.02), but warm sensation (WS)and heat-induced pain (HIP) were only significantly increased in males onERT (P<0.01). However, corneal sensation assessed withNCCAwas significantly reduced in female (P < 0.02) and male (P < 0.04) patients on ERT compared with control subjects. According to CCM, corneal nerve fiber and branch density was significantly reduced in female (P < 0.03) and male (P < 0.02) patients on ERT compared with control subjects. Furthermore, the severity of neuropathic symptoms and the neurological component of the Mainz Severity Score Index correlated significantly with QSTand CCM. This study shows that CCM and NCCA provide a novel means to detect early nerve fiber damage and dysfunction, respectively, in patients with Fabry disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims: To investigate IOP measurements with the dynamic contour tonometer (DCT) and non contact tonometer (NCT) in subjects with keratoconus. Methods: Twenty keratoconic subjects and 20 age-matched control subjects had IOP measurements taken using DCT and NCT instruments. Central and offcentre measures were taken with the DCT in order to highlight any systematic errors associated with corneal biomechanical factors. Measures of anterior and posterior corneal topography and thickness were also taken for each subject. Results: No significant difference was found between the central and off-centre DCT IOP readings for the keratoconics and age-matched controls (p>0.05). The average DCT IOP for the keratoconics was 14.2 ± 1.4 mmHg and for the agematched controls was 14.2 ± 1.6 mmHg. However, the average NCT readings differed significantly (p<0.001) between the keratoconics (9.2 ± 1.5 mmHg) and age-matched controls (12.9 ± 2.4 mmHg). DCT IOP showed no significant (p>0.05) correlation with the severity of keratoconus, as determined through measures of corneal topography and thickness. NCT IOP was correlated significantly with certain measures of corneal curvature and thickness in the keratoconic population. The difference between DCT and NCT IOP was strongly correlated with measures of corneal topography and thickness, with differences increasing for more advanced keratoconus. Conclusions: The measurements from the DCT do not appear to be dependent upon corneal factors, unlike the NCT. The presence or severity of keratoconus was not correlated with DCT IOP values.