99 resultados para NiTi]
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective. To evaluate the healing of experimentally induced chronic periapical lesions in dogs at 30, 75, and 120 days after root canal instrumentation with rotary NiTi files or manual K-files, with or without a calcium hydroxide/1% chlorhexidine paste intracanal dressing.Study design. The second, third, and fourth mandibular premolars and the second and third maxillary premolars of 5 dogs (12 to 18 months of age, weighing 8 to 15 kg) were selected for treatment (a total of 82 root canals). After pulp removal, the root canals were left exposed to the oral cavity for 7 days to allow microbial contamination, after which the root canals were sealed with ZOE cement until periapical lesions were confirmed with radiography. Group I and II teeth were instrumented with manual K-files using the crown-down technique. In group III and IV teeth, NiTi rotary files were used. The apical delta was perforated by using #20 to #30 K-files at the length of the tooth, thus creating a standardized apical opening. The apical stop was enlarged to size 70, with 2.5% sodium hypochlorite irrigation at each file change. Teeth in groups II and IV were dressed with calcium hydroxide (Ca(OH)(2))/1% chlorhexidine (CHX) paste for 15 days before root filling. Group I and III teeth did not receive an intracanal dressing. The access openings of the teeth were permanently restored with silver amalgam condensed on a glass ionomer cement base. Pairs of standardized periapical radiographs were taken at the beginning of the treatment (0 days) and at 30, 75, and 120 days after filling.Results. There was no significant difference in the rate of radiographic healing of the periapical lesions between manual and rotary instrumentation. Radiographs taken at 120 days showed that the treatment with Ca(OH)(2)/1% CHX paste resulted in a significant reduction in mean size of the periapical lesions in comparison to single-session treatment. These findings were also true for histologic observations.Conclusion. The findings support the hypothesis that, regardless of the instrumentation technique (manual or rotary), the use of an intracanal dressing is important in the endodontic treatment of dog's teeth with experimentally induced chronic periapical lesions.
Resumo:
Objective: the aim of this study was to evaluate the biomechanical preparation of flattened root canals using the following systems: Endo-Eze AET stainless steel oscillatory instruments (Ultradent) and RaCe rotary NiTi instruments (FKG Dentaire). Materials and Methods: Twenty extracted human mandibular incisors were randomly assigned to two groups: Group I Instrumentation with oscillatory Endo-Eze AET files (oscillatory technique); Group 2 - Instrumentation with rotary NiTi RaCe files (rotary technique). The teeth were decoronated, had their apices and coronal openings sealed with sticky wax and were embedded in crystal-clear orthophtalic polyester resin. The roots were sectioned transversally with diamond discs at 10 mm (middle third) and 5 mm (apical third) from the apex and the segments were reassembled for instrumentation. The sections were photographed before and after root canal instrumentation and evaluated with respect to whether the original root canal shape was modified by instrumentation. To evaluate the differences in the root canal shape before and after biomechanical preparation, scores were given regarding the instruments touch on the intracanal walls. Results: In middle third of the root canals instrumented with the rotary system, there was a change in the original canal anatomy (p < 0.05), with formation of a protuberance in the mesiodistal direction. This protuberance did not occur when the oscillatory instrumentation was used. The oscillatory system had better results in the middle and apical thirds as evaluated by Dunn's multiple-comparison test (p > 0.05). Conclusion: Under the tested conditions, Endo-Eze oscillatory system yielded the instrumentation of all flattened oot canal walls, maintaining the canal original shape throughout the biomechanical preparation, and was more effective than RaCe rotary system.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to evaluate the effectiveness of manual and rotary instrumentation techniques for removing root fillings after different storage times. Twenty-four canals from palatal roots of human maxillary molars were instrumented and filled with gutta-percha and zinc-oxide eugenol-based sealer (Endofill), and were stored in saline for 6 years. Non-aged control specimens were treated in the same manner and stored for 1 week. All canals were retreated using hand files or ProTaper Universal NiTi rotary system. Radiographs were taken to determine the amount of remaining material in the canals. The roots were vertically split, the halves were examined with a clinical microscope and the obtained images were digitized. The images were evaluated with AutoCAD software and the percentage of residual material was calculated. Data were analyzed with two-way ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) between the manual and rotary techniques for filling material removal regardless the ageing effect on endodontic sealers. When only the age of the filling material was analyzed microscopically, non-aged fillings that remained on the middle third of the canals presented a higher percentage of material remaining (p<0.05) compared to the aged sealers and to the other thirds of the roots. The apical third showed a higher percentage of residual filling material in both radiographic and microscopic analysis when compared to the other root thirds. In conclusion, all canals presented residual filling material after endodontic retreatment procedures. Microscopic analysis was more effective than radiographs for detection of residual filling material.
Resumo:
This study evaluated the efficacy of 2 types of rotary instruments employed in association with sodium hypochlorite (NaOCl) or EDTA in removing calcium hydroxide (CH) residues from root canals dentin walls. Forty-two mandibular human incisors were instrumented with the ProTaper System up to F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA and filled with a CH intracanal dressing. After 7 days, the CH dressing was removed using 4 techniques: NiTi rotary instrument size 25, 0.06 taper (K3 Endo) and irrigation with 17% EDTA (Group 1), NiTi rotary F1 instrument (ProTaper) and irrigation with 17% EDTA (Group 2), NiTi rotary instrument size 25, 0.06 taper and irrigation with 2.5% NaOCl (Group 3) and NiTi rotary F1 instrument and irrigation with 2.5% NaOCl (Group 4). Two roots without intracanal dressing were used as negative controls. Teeth were evaluated by scanning electron microscopy, in the cervical and apical canal thirds. None of the techniques removed the CH dressing completely. In the apical and cervical thirds, F1 instrument was better than instrument size 25, 0.06 taper in removing CH residues (p<0.05), regardless of the final irrigating solution. No difference was found between the irrigating solutions in the groups of F1 instrument and of instrument size 25, 0.06 taper (p>0.05). The negative controls had no CH residues on the dentin walls. In conclusion, the ProTaper F1 instrument was better than K3 Endo instrument size 25, 0.06 taper in the removal of CH intracanal medication, regardless of irrigating solution used.
Resumo:
Background/Aim: The present research evaluated the induction of ankylosis and the eruption rate in rat incisors, with the aim of achieving stable anchorage for orthodontic tooth movement (OTM) of the molars. Material and methods: Fifteen male Wistar rats were used. In the Experimental group, the right superior incisor of each animal was extracted, denuded of the PDL and the dental papilla, and reimplanted. The Control group was the left superior incisors. The eruption rate was measured at 7, 10, 12, 14, and 16 days after replantation. NiTi closed springs with a 50cN release force were installed for additional 9 days, and the eruption rate was determined. Then, the rats were sacrificed, and ankylosis was examined by microscopic analysis. Differences with P < 0.01 were defined as statistically significant. Results: The eruption rates were 0 and 0.39 mm day-1 in the Experimental group and Control group, respectively. All incisors of the Experimental group showed ankylosis according to histological analysis. Conclusions: The methodology used to induce ankylosis in this study was effective for anchoring the incisors during the OTM of rat molars, eliminating the undesirable effects consequent to continuous eruption. © 2013 John Wiley & Sons A/S.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O objetivo do presente estudo foi avaliar a resistência à fadiga cíclica de instrumentos rotatórios de níquel-titânio de diferentes características geométricas, antes e após o uso em canais artificiais. Foram selecionadas limas rotatórias do Sistema Race (FKG Dentaire) e do Sistema K3 (SybronEndo) de conicidade 0,04, com 25mm de comprimento e diâmetro de ponta de 25, padrão ISO. As mesmas foram divididas em quatro grupos experimentais, com doze limas cada, totalizando quarenta e oito instrumentos. Os grupos foram assim divididos: grupo A0, instrumentos Race sem nenhum uso; grupo A5, instrumentos Race de cinco usos; grupo B0, instrumentos K3 de nenhum uso e grupo B5, instrumentos K3 de cinco usos. A simulação de uso foi realizada em canais artificiais de resina, com curvatura de 40° e raio de 5mm, utilizando uma peça de mão com contra-ângulo, acionado por motor elétrico, na velocidade de 350 rpm e 1 N/cm de torque. Todos os grupos foram submetidos a ensaios de fadiga cíclica num dispositivo que permitia o instrumento girar livremente, reproduzindo uma instrumentação rotatória num canal curvo. O tempo despendido até a fratura foi aferido por um cronômetro. Para avaliação estatística empregou-se o teste ANOVA para dois fatores e foi observada diferença estatisticamente significante entre as amostras. O teste de Tukey foi utilizado para verificar a diferença entre as médias dos grupos. Os resultados mostraram que o uso e a característica geométrica dos instrumentos influenciam na sua resistência à fadiga cíclica (p<0,05). As limas do grupo B0 (K3 sem nenhum uso) apresentaram maior resistência à fadiga, quando comparadas às limas dos demais grupos experimentais, independente do número de uso.
Resumo:
O presente trabalho teve por objetivo a avaliação da ação dos instrumentos nas paredes do terço apical do canal radicular a 1 e 3mm do CRT, em incisivos inferiores, após preparo com limas NiTi-Flex em rotação alternada, e contínua pelo uso dos sistemas de NiTi: K3, Race, Protaper. Para avaliação da limpeza se utilizou cortes histológicos, na qual a luz do canal foi dividida em quatro quadrantes de acordo com a face (DL, DV, ML, MV). Os resultados mostraram que de modo geral, os melhores resultados foram encontrados para a rotação alternada, sendo seguido pelo sistema Protaper (p<0,05). Os piores resultados foram encontrados para K3 (62,5% sujos), não havendo diferenças estatísticas àqueles encontrados para o sistema Race (45%). Na avaliação dos quadrantes, o mésio-lingual foi considerado o mais sujo para os dois níveis avaliados (p<0,05). Ao final, foi observado que nenhuma das técnicas testadas foi capaz de limpar com efetividade as paredes dos canais radiculares de incisivos inferiores.