887 resultados para Needle biopsy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: This study was undertaken to assess whether fine needle aspirates from non-Hodgkins lymphoma (NHL) could be used for growth fraction analysis with proliferating cell nuclear antigen (PCNA) staining and if there was a relationship between the growth fraction and cytomorphologic classification according to the Kiel classification.STUDY DESIGN: the study group consisted of 40 patients with NHL diagnosed by fine needle aspiration (FNA) cytology. The cytologic classification of the lymphomas was made by two cytopathologists on May-Grunwald-Giemsa-stained slides using the Kiel classification. There were 27 cases of low and 13 of high grade lymphoma. The estimation of the growth fraction was made by PCNA immunoreactivity. The PCNA index was quantitated in smears by counting an average of 1,000 cells, and the count teas correlated with the cytomorphologic classification.RESULTS: There was It strong correlation between the PCNA index and lymphoma grading. High grade lymphomas exhibited a mean PCNA positivity of 74.0%, which was significantly higher (P <.001) than that of low grade lymphomas (17.6%).CONCLUSION: Our study showed that PCNA evalua tion is suitable for smears obtained by FNA on NHL, correlates with increasing grades of lymphoma according to the Kiel classification and may offer a method of monitoring treatment of lymphoma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cytomorphologic characteristics of smears from fine-needle aspirates (FNA) of three cases of sinus histiocytosis with massive lymphadenopathy (SHML) (Rosai-Dorfman disease) are described. All aspirates showed mature lymphocytes, plasma cells, and large pale histiocytes with well-preserved lymphocytes within the cytoplasm (lymphocytophagocytosis). The cases were confirmed by surgical biopsy, and the immunohistochemical findings suggested a macrophage origin for this lesion. The value of FNA analysis as an aid to diagnosis of SHML is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sequelae due to testicular biopsy such as hemorrhage, adhesion and fibrosis may be limiting factors to the use of this surgical procedure. Fibrin glue (FG) derived from snake venom was used to minimize these sequelae, as well as to evaluate its healing property in tunica vaginalis and scrotal skin of rams. Applicability of fibrin glue derived from snake venom was tested in different tissues of other animals such as in sciatic nerve and colon of rats and skin of rabbits. In the present study, 30 healthy adult rams were used. They were divided into 3 groups of 10 animals each as follows: G1: fibrin glue group (application of fibrin glue on puncture sites and skin incisions after bilateral testicular biopsy with a Tru-Cut needle); G2: swab/nylon group (hemostasis by compression with a swab on puncture sites and skin suturing with nylon after biopsy) and G3: control group (the animals were not subjected either to biopsy or to surgery). On the 20th day after biopsy, the presence of adhesion strands between the sites of skin incision and testicle was evaluated by palpation Adhesion strands were found in three testicles (15%) in G1 and in two testicles (10%) in G2. One hundred days after biopsy, orchiectomy was carried out and the material collected was assessed for subcutaneous (SC) and/or tunica vaginalis adhesions. G3 did not present any abnormality. Groups G1 and G2 presented four testicles each (20%) with adhesion between the tunics at biopsy site. On the other hand, subcutaneous adhesions were found once (5%) in G1 and three times (15%) in G2. Fibrin glue showed to be of easy application, required short postoperative monitoring, presented fast and good-quality healing property and tended to reduce formation of subcutaneous adhesion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To evaluate the reliability of fine needle aspirate cell blocks in the assessment of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins by immunohistochemistry in comparison with surgical specimens. Materials and methods: This is a retrospective study of 62 cases of breast carcinoma diagnosed by fine needle aspiration cytology (FNAC) and confirmed using the surgical specimen. Immunohistochemical tests were performed to assess the presence of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins in cell blocks and the corresponding surgical specimens. The cell block method used alcohol prior to formalin fixation. Cases with 10% or more stained cells were considered positive for ER and PR. Positivity for HER-2/neu was assessed on a scale of 0-3+. The criterion for positivity was a score of 3+. Results: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the cell blocks in the investigation of ER, PR and HER-2/neu protein (3+) were (%): ER, 92.7, 85.7, 92.7, 85.7 and 90.3; PR, 92.7, 94.7, 97.4, 87.0 and 93.5; HER-2/neu, 70.0, 100.0, 100.0, 94.5 and 95.2. Discrepancies were seen in cell blocks in the 1+ and 2+ HER-2/neu staining scores: two of 12 cases scoring 2+ and one case of 26 scoring 1+ on cell blocks scored 3+ on surgical specimens. The correlation index between cell block and corresponding surgical specimen varied from 90% to 94%. Conclusion: Cell blocks provide a useful method of assessing ER, PR and HER-2/neu, mainly for inoperable and recurrent cases, but consideration should be given to carrying out FISH analysis on 1+ as well as 2+ HER-2/neu results. © 2012 Blackwell Publishing Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Metastases to the pancreas are rare, and usually mistaken for primary pancreatic cancers. This study aimed to describe the histology results of solid pancreatic tumours obtained by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosis of metastases to the pancreas. Methods In a retrospective review, patients with pancreatic solid tumours and history of previous extrapancreatic cancer underwent EUS-FNA from January/1997 to December/2010. Most patients were followed-up until death and some of them were still alive at the end of the study. The performance of EUS-FNA for diagnosis of pancreatic metastases was analyzed. Symptoms, time frame between primary tumour diagnosis and the finding of metastases, and survival after diagnosis were also analyzed. Results 37 patients underwent EUS-FNA for probable pancreas metastases. Most cases (65%) presented with symptoms, especially upper abdominal pain (46%). Median time between detection of the first tumour and the finding of pancreatic metastases was 36 months. Metastases were confirmed in 32 (1.6%) cases, 30 of them by EUS-FNA, and 2 by surgery. Other 5 cases were non-metastatic. Most metastases were from lymphoma, colon, lung, and kidney. Twelve (32%) patients were submitted to surgery. Median survival after diagnosis of pancreatic metastases was 9 months, with no difference of survival between surgical and non-surgical cases. Sensitivity, specificity, positive and negative predictive values, and accuracy of EUS-FNA with histology analysis of the specimens for diagnosis of pancreatic metastases were, respectively, 93.8%, 60%, 93.8%, 60% and 89%. Conclusion EUS-FNA with histology of the specimens is a sensitive and accurate method for definitive diagnosis of metastatic disease in patients with a previous history of extrapancreatic malignancies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a case of a 78-year-old female with a proximal femur fracture caused by an accidental fall who died suddenly 1h after orthopaedic prosthesis insertion. Post-mortem computed tomography (CT) scan and histological examination of samples obtained with post-mortem percutaneous needle biopsies of both lungs were performed. Analysis of the medical history and the clinical scenario immediately before death, imaging data, and biopsy histology established the cause of death without proceeding to traditional autopsy. It was determined to be acute right ventricular failure caused by massive pulmonary fat embolism. Although further research in post-mortem imaging and post-mortem tissue sampling by needle biopsies is necessary, we conclude that the use of CT techniques and percutaneous biopsy, as additional tools, can offer a viable alternative to traditional autopsy in selected cases and may increase the number of minimally invasive forensic examinations performed in the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Recent advances in medical imaging have brought post-mortem minimally invasive computed tomography (CT) guided percutaneous biopsy to public attention. AIMS: The goal of the following study was to facilitate and automate post-mortem biopsy, to suppress radiation exposure to the investigator, as may occur when tissue sampling under computer tomographic guidance, and to minimize the number of needle insertion attempts for each target for a single puncture. METHODS AND MATERIALS: Clinically approved and post-mortem tested ACN-III biopsy core needles (14 gauge x 160 mm) with an automatic pistol device (Bard Magnum, Medical Device Technologies, Denmark) were used for probe sampling. The needles were navigated in gelatine/peas phantom, ex vivo porcine model and subsequently in two human bodies using a navigation system (MEM centre/ISTB Medical Application Framework, Marvin, Bern, Switzerland) with guidance frame and a CT (Emotion 6, Siemens, Germany). RESULTS: Biopsy of all peas could be performed within a single attempt. The average distance between the inserted needle tip and the pea centre was 1.4mm (n=10; SD 0.065 mm; range 0-2.3 mm). The targets in the porcine liver were also accurately punctured. The average of the distance between the needle tip and the target was 0.5 mm (range 0-1 mm). Biopsies of brain, heart, lung, liver, pancreas, spleen, and kidney were performed on human corpses. For each target the biopsy needle was only inserted once. The examination of one body with sampling of tissue probes at the above-mentioned locations took approximately 45 min. CONCLUSIONS: Post-mortem navigated biopsy can reliably provide tissue samples from different body locations. Since the continuous update of positional data of the body and the biopsy needle is performed using optical tracking, no control CT images verifying the positional data are necessary and no radiation exposure to the investigator need be taken into account. Furthermore, the number of needle insertions for each target can be minimized to a single one with the ex vivo proven adequate accuracy and, in contrast to conventional CT guided biopsy, the insertion angle may be oblique. Navigation for minimally invasive tissue sampling is a useful addition to post-mortem CT guided biopsy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE This study presents the first in vivo real-time optical tissue characterization during image-guided percutaneous intervention using near-infrared diffuse optical spectroscopy sensing at the tip of a needle. The goal of this study was to indicate transition boundaries from healthy tissue to tumors, namely, hepatic carcinoma, based on the real-time feedback derived from the optical measurements. MATERIALS AND METHODS Five woodchucks with hepatic carcinoma were used for this study. The woodchucks were imaged with contrast-enhanced cone beam computed tomography with a flat panel detector C-arm system to visualize the carcinoma in the liver. In each animal, 3 insertions were performed, starting from the skin surface toward the hepatic carcinoma under image guidance. In 2 woodchucks, each end point of the insertion was confirmed with pathologic examination of a biopsy sample. While advancing the needle in the animals under image guidance such as fluoroscopy overlaid with cone beam computed tomography slice and ultrasound, optical spectra were acquired at the distal end of the needles. Optical tissue characterization was determined by translating the acquired optical spectra into clinical parameters such as blood, water, lipid, and bile fractions; tissue oxygenation levels; and scattering amplitude related to tissue density. The Kruskal-Wallis test was used to study the difference in the derived clinical parameters from the measurements performed within the healthy tissue and the hepatic carcinoma. Kurtoses were calculated to assess the dispersion of these parameters within the healthy and carcinoma tissues. RESULTS Blood and lipid volume fractions as well as tissue oxygenation and reduced scattering amplitude showed to be significantly different between the healthy part of the liver and the hepatic carcinoma (P < 0.05) being higher in normal liver tissue. A decrease in blood and lipid volume fractions and tissue oxygenation as well as an increase in scattering amplitude were observed when the tip of the needle crossed the margin from the healthy liver tissue to the carcinoma. The kurtosis for each derived clinical parameter was high in the hepatic tumor as compared with that in the healthy liver indicating intracarcinoma variability. CONCLUSIONS Tissue blood content, oxygenation level, lipid content, and tissue density all showed significant differences when the needle tip was guided from the healthy tissue to the carcinoma and can therefore be used to identify tissue boundaries during percutaneous image-guided interventions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Funding/Support and role of the sponsor: None.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Funding/Support and role of the sponsor: None.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The dichotomization of non-small cell carcinoma (NSCLC) subtype into squamous (SQCC) and adenocarcinoma (ADC) has become important in recent years and is increasingly required with regard to management. The aim of this study was to determine the utility of a panel of commercially available antibodies in refining the diagnosis on small biopsies and also to determine whether cytologic material is suitable for somatic EGFR genotyping in a prospectively analyzed series of patients undergoing investigation for suspected lung cancer. METHODS: Thirty-two consecutive cases of NSCLC were first tested using a panel comprising cytokeratin 5/6, P63, thyroid transcription factor-1, 34betaE12, and a D-PAS stain for mucin, to determine their value in refining diagnosis of NSCLC. After this test phase, two further pathologists independently reviewed the cases using a refined panel that excluded 34betaE12 because of its low specificity for SQCC, and refinement of diagnosis and concordance were assessed. Ten cases of ADC, including eight derived from cytologic samples, were sent for EGFR mutation analysis. RESULTS: There was refinement of diagnosis in 65% of cases of NSCLC to either SQCC or ADC in the test phase. This included 10 of 13 cases where cell pellets had been prepared from transbronchial needle aspirates. Validation by two further pathologists with varying expertise in lung pathology confirmed increased refinement and concordance of diagnosis. All samples were adequate for analysis, and they all showed a wild-type EGFR genotype. CONCLUSION: A panel comprising cytokeratin 5/6, P63, thyroid transcription factor-1, and a D-PAS stain for mucin increases diagnostic accuracy and agreement between pathologists when faced with refining a diagnosis of NSCLC to SQCC or ADC. These small samples, even cell pellets derived from transbronchial needle aspirates, seem to be adequate for EGFR mutation analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Describes case studies of 2 males (aged 28 and 30 yrs) in which in vivo practice was applied to needle phobia and associated vasovagal fainting. In vivo practice combines skill acquisition with an opportunity to disconfirm negative expectations. Substantial improvements in self-efficacy, anxiety, and performance were obtained. Treatment gains generalized to other settings and were maintained at 3–6 mo follow-up. In vivo practice is recommended for further research into needle phobias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utilising archival human breast cancer biopsy material we examined the stromal/epithelial interactions of several matrix metalloproteinases (MMPs) using in situ-RT-PCR (IS-RT-PCR). In breast cancer, the stromal/epithelial interactions that occur, and the site of production of these proteases, are central to understanding their role in invasive and metastatic processes. We examined MT1-MMP (MMP-14, membrane type-1-MMP), MMP-1 (interstitial collagenase) and MMP-3 (stromelysin-1) for their localisation profile in progressive breast cancer biopsy material (poorly differentiated invasive breast carcinoma (PDIBC), invasive breast carcinomas (IBC) and lymph node metastases (LNM)). Expression of MT1-MMP, MMP-1 and MMP-3 was observed in both the tumour epithelial and surrounding stromal cells in most tissue sections examined. MT1-MMP expression was predominantly localised to the tumour component in the pre-invasive lesions. MMP-1 gene expression was relatively well distributed between both tissue compartments, while MMP-3 demonstrated highest expression levels in the stromal tissue surrounding the epithelial tumour cells. The results demonstrate the ability to distinguish compartmental gene expression profiles using IS-RT-PCR. Further, we suggest a role for MT1-MMP in early tumour progression, expression of MMP-1 during metastasis and focal expression pattern of MMP-3 in areas of expansion. These expression profiles may provide markers for early breast cancer diagnoses and present potential therapeutic targets.