965 resultados para National standards


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. The general aim of this article is to describe the state-of-the-art of biocompatibility testing for dental materials, and present new strategies for improving operative dentistry techniques and the biocompatibility of dental materials as they relate to their interaction with the dentin-pulp complex.Methods. The literature was reviewed focusing on articles related to biocompatibilty testing, the dentin-pulp complex and new strategies and materials for operative dentistry. For this purpose, the PubMed database as well as 118 articles published in English from 1939 to 2014 were searched. Data concerning types of biological tests and standardization of in vitro and in vivo protocols employed to evaluate the cytotoxicity and biocompatibility of dental materials were also searched from the US Food and Drug Administration (FDA), International Standards Organization (ISO) and American National Standards Institute (ANSI).Results. While there is an ongoing search for feasible strategies in the molecular approach to direct the repair or regeneration of structures that form the oral tissues, it is necessary for professionals to master the clinical therapies available at present. In turn, these techniques must be applied based on knowledge of the morphological and physiological characteristics of the tissues involved, as well as the physical, mechanical and biologic properties of the biomaterials recommended for each specific situation. Thus, particularly within modern esthetic restorative dentistry, the use of minimally invasive operative techniques associated with the use of dental materials with excellent properties and scientifically proved by means of clinical and laboratory studies must be a routine for dentists. This professional and responsible attitude will certainly result in greater possibility of achieving clinical success, benefiting patients and dentists themselves.Signcance. This article provides a general and critical view of the relations that permeate the interaction between dental materials and the dentin-pulp complex, and establish real possibilities and strategies that favor biocompatibility of the present and new products used in Dentistry, which will certainly benefit clinicians and their patients. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This research aims to present a new method to get real attenuation of hearing protection devices, with good reproducibility and a small standard deviation, without relying on skills and cooperation individual. Thus the authors performed tests in 10 individuals without protection and after with two kinds of ear protections (ear plug and ear muffs), to get the threshold limit value in each of the 3 stages. For this, the research used an electrophysical exam, normally used in speech therapy, named ASSR (auditory steady-state response). The principle of this exam is put on individual’s head 3 electrodes, to capture electrical signs directly in auditory nerve. In summary, the authors presented the final results. The method proposed by ANSI (American National Standards Institute) indicated an attenuation of 27.6 dB for ear plugs, while the value found in this work was 16 dB; and for ear muffs, the ANSI method indicated 29.8 dB while the value found here was 28.5 dB.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The rising in greenhouse gases emission as consequence of industrial expansion especially in developing countries is appointed as one of those reasons responsible for global warming. High-level temperatures are set as responsible for low productivity and high levels of discomfort. With the increase of worldwide energy demand, due to the population growth, this work aims to be an introductory text revising the current ventilation (mechanical and natural) and refrigeration technologies as well as low energy cooling techniques and architectural alternatives that seeks offering good ventilation and ideal buildings temperatures, making them sustainable. In addition, the text deals with the measurement instruments used to evaluate the parameters defined by international and national standards. At last, a case of study applies few concepts and technologies described in the text, introducing the results achieved, the limitations and suggestions to future works

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The rising in greenhouse gases emission as consequence of industrial expansion especially in developing countries is appointed as one of those reasons responsible for global warming. High-level temperatures are set as responsible for low productivity and high levels of discomfort. With the increase of worldwide energy demand, due to the population growth, this work aims to be an introductory text revising the current ventilation (mechanical and natural) and refrigeration technologies as well as low energy cooling techniques and architectural alternatives that seeks offering good ventilation and ideal buildings temperatures, making them sustainable. In addition, the text deals with the measurement instruments used to evaluate the parameters defined by international and national standards. At last, a case of study applies few concepts and technologies described in the text, introducing the results achieved, the limitations and suggestions to future works

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the pH, calcium ion release, setting time, and solubility of white mineral trioxide aggregate (WMTA) and white Portland cement (WPC) combined with the following radiopacifying agents: bismuth oxide (BO), calcium tungstate (CT), and zirconium oxide (ZO). Methods: Fifty acrylic teeth with root-end filling material were immersed in ultrapure water for measurement of pH and calcium release (atomic absorption spectrophotometry) at 3, 24, 72, and 168 hours. For evaluation of setting time, each material was analyzed according to the American Society for Testing and Materials guidelines 266/08. The solubility test was performed according to American National Standards Institute/American Dental Association specification no. 57/2000. Solubility, setting time, and pH values were compared by using analysis of variance and Tukey test, and the values of calcium release were compared by the Kruskal-Wallis and Miller tests. The significance level was set at 5%. Results: The pH and calcium release were higher at 3 and 24 hours. WPC was the material with the higher values for both properties. WMTA had the greatest solubility among all materials (P < .05). All radiopacifiers increased the setting time of WPC, and WMTA had the shortest setting time among all materials (P < .05). Conclusions: All materials released calcium ions. Except for WPC/CT at 168 hours, all materials promoted an alkaline pH. On the basis of the obtained results, ZO and CT can be considered as potential radiopacifying agents to be used in combination with Portland cement. (J Endod 2012;38:394-397)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Baldi JV, Bernardes RA, Duarte MAH, Ordinola-Zapata R, Cavenago BC, Moraes JCS, de Moraes IG. Variability of physicochemical properties of an epoxy resin sealer taken from different parts of the same tube. International Endodontic Journal,similar to 45, 915920, 2012. Abstract Aim To analyse several physicochemical properties of AH Plus (Dentsply DeTrey, Konstanz, Germany), including setting time, flow, radiopacity and the degree of conversion (DC); and to correlate the results with the source of the material: from the beginning, middle or end of the tubes in which they were supplied. Methodology Three experimental groups were established for each property investigated. Group 1 corresponded to material taken from the beginning of tubes A and B; Group 2 corresponded to material taken from the middle of each tube; and group 3 corresponded to that from the end of each tube. The setting time, flow and radiopacity were studied according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. DC was determined from infrared spectra, which were recorded at 1-h intervals for the first 6 h; then, at 2-h intervals for the next 14 h; then, at 24 and 30 h. Data were analysed statistically by analysis of variance (anova), TukeyKramer, KruskalWallis and Dunn tests, with a significance level of 5%. Results Group 1 had a significantly longer setting time (2303 +/- 1058 min) (P < 0.05). Group 3 had the lowest flowability (30.0 +/- 0.7 mm) and the highest radiopacity (14.85 +/- 1.8 mm Al) (P < 0.05). No differences were found for the DC test (P > 0.05). Conclusion The results suggest that segregation occurs between the organic and inorganic components of AH Plus sealer, thereby changing the setting time, flow and radiopacity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Signs are used extensively in workplaces and on products to identify hazards and provide instructions for appropriate behavior. A fundamental element of these signs is the signal-word panel located at the top of the sign. The colors and words in this panel are intended to convey information about the hazard identified. One type of hazard information concerns the severity of injury/illness associated with the hazard. The standard of the American National Standards Institute (ANSI) for facility signs uses three severity categories: 1) death or serious injury, 2) minor or moderate injury, and 3) property damage. The standard specifies which signal-word panel format, including color, to use based in part on the severity category. The purpose of this study was to determine if college students associate color with severity. The sample population consisted of 59 students tested in nine small groups. Twelve signs were shown to them in random order. Five of the signs had a color for the background of the signal-word panel. The colors were red, orange, yellow, blue, and gray. The signal word was a nonsense word and the text panel contained repetitions of the letter x in sentence format. Subject rated their impressions of the colors using two ordered rating scales for severity. Results indicated that color had a highly significant effect on severity ratings. Median ratings were generally consistent with the ANSI standard, except for orange. Red rated highest on both scales. Blue and gray rated lowest. Yellow and orange were in between red and blue. According to the ANSI standard, orange should indicate the same severity as red. These results indicated that orange was associated with less severity than red. Apparently, the ANSI standard's use of orange to identify a hazard associated with death or a serious injury is questionable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The demand for international harmonization in medical education increases with the growing mobility of students and health professionals. Many medical societies and governmental offices have issued outcome frameworks (OF), which describe aims and contents of medical education based on competencies. These national standards affect the development of curricula as well as assessment and licensing procedures. Comparing OF and identifying factors that limit their comparability may thus foster international harmonization of medical education. Summary of Work: We conducted a systematic search for national OF in MedLine, EmBase and the internet. We included all OF in German or English that resulted from a national consensus process and were published or endorsed by a national society or governmental body. We extracted information in five predetermined categories: history of origin, audience, formal structure, medical schooling system and key terms. Summary of Results: Out of 1816 results, 13 OF were included into further analyses. OF reference each other, often without addressing existing differences (e.g. in target audiences). The two most cited OF are “CanMEDs” and “Scottish Doctor”. OF differ especially in their level of detail as well as in the underlying educational system. Discussion and Conclusions: Based on our results we propose a two-step blueprint for OF, that may help to establish comparability for internationally aligned key features – so-called “core competencies” – while at the same time allowing for necessary regional adaptations in terms of “secondary competencies”. Take-home messages: Considerable differences in at least five categories of OF currently hinder the comparability of outcome frameworks.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives. The objectives of this report were to describe current best standards in online education, class competencies, class objectives, class activities and to compare the class competencies, objectives and activities undertaken with the current best practices in online teaching and to provide a list of recommendations based on the most efficacious practices. ^ Methods. Utilizing the key words- online teaching, national standards, quality, online courses, I: (1) conducted a search on Google to find the best standard for quality online courses; the search yielded National Standards for Quality Online Teaching as the gold standard in online course quality; (2) specified class objectives and competencies as well as major activities undertaken as a part of the class. Utilizing the Southern Regional Education Board evaluation checklist for online courses, I: (1) performed an analysis comparing the class activities, objectives, and competencies with the current best standards; (2) utilized the information obtained from the analysis and class experiences to develop recommendations for the most efficacious online teaching practices. ^ Results. The class met the criteria set by the Southern Regional Education Board for evaluating online classes completely in 75%, partially in 16% and did not meet the criteria in 9% cases. The majority of the parameters in which the class did not meet the standards (4 of 5) were due to technological reasons beyond the scope of the class instructor, teaching assistant and instructional design. ^ Discussion. Successful online teaching requires awareness of technology, good communication, methods, collaboration, reflection and flexibility. Creation of an online community, engaging online learners and utilizing different learning styles and assessment methods promote learning. My report proposes that online teaching should actively engage the students and teachers with multiple interactive strategies as evidenced from current best standards of online education and my “hands-on” work experience. ^ Conclusion. The report and the ideas presented are intended to create a foundation for efficacious practice on the online teaching platform. By following many of the efficacious online practices described in the report and adding from their own experiences, online instructors and teaching assistants can contribute to effective online learning. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

All activities of an organization involve risks that should be managed. The risk management process aids decision making by taking account of uncertainty and the possibility of future events or circumstances (intended or unintended) and their effects on agreed objectives. With that idea, new ISO Standard has been drawn up. ISO 31010 has been recently issued which provides a structured process that identifies how objectives may be affected, and analyses the risk in term of consequences and their probabilities before deciding on whether further treatment is required. In this lecture, that ISO Standard has been adapted to Open Pit Blasting Operations, focusing in Environmental effects which can be managed properly. Technique used is Fault Tree Analysis (FTA), which is applied in all possible scenarios, providing to Blasting Professionals the tools to identify, analyze and manage environmental effects in blasting operations. Also this lecture can help to minimize each effect, studying each case. This paper also can be useful to Project Managers and Occupational Health and Safety Departments (OH&S) because blasting operations can be evaluated and compared one to each other to determine the risks that should be managed in different case studies. The environmental effects studied are: ground vibrations, flyrock and air overpressure (airblast). Sometimes, blasting operations are carried out near populated areas where environmental effects may impose several limitations on the use of explosives. In those cases, where these factors approach certain limits, National Standards and Regulations have to be applied.