935 resultados para NMR pulse sequence design


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hepatitis C virus (HCV) vaccine efficacy may crucially depend on immunogen length and coverage of viral sequence diversity. However, covering a considerable proportion of the circulating viral sequence variants would likely require long immunogens, which for the conserved portions of the viral genome, would contain unnecessarily redundant sequence information. In this study, we present the design and in vitro performance analysis of a novel "epitome" approach that compresses frequent immune targets of the cellular immune response against HCV into a shorter immunogen sequence. Compression of immunological information is achieved by partial overlapping shared sequence motifs between individual epitopes. At the same time, sequence diversity coverage is provided by taking advantage of emerging cross-reactivity patterns among epitope variants so that epitope variants associated with the broadest variant cross-recognition are preferentially included. The processing and presentation analysis of specific epitopes included in such a compressed, in vitro-expressed HCV epitome indicated effective processing of a majority of tested epitopes, although re-presentation of some epitopes may require refined sequence design. Together, the present study establishes the epitome approach as a potential powerful tool for vaccine immunogen design, especially suitable for the induction of cellular immune responses against highly variable pathogens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A two-pronged approach for the automatic quantitation of multiple sclerosis (MS) lesions on magnetic resonance (MR) images has been developed. This method includes the design and use of a pulse sequence for improved lesion-to-tissue contrast (LTC) and seeks to identify and minimize the sources of false lesion classifications in segmented images. The new pulse sequence, referred to as AFFIRMATIVE (Attenuation of Fluid by Fast Inversion Recovery with MAgnetization Transfer Imaging with Variable Echoes), improves the LTC, relative to spin-echo images, by combining Fluid-Attenuated Inversion Recovery (FLAIR) and Magnetization Transfer Contrast (MTC). In addition to acquiring fast FLAIR/MTC images, the AFFIRMATIVE sequence simultaneously acquires fast spin-echo (FSE) images for spatial registration of images, which is necessary for accurate lesion quantitation. Flow has been found to be a primary source of false lesion classifications. Therefore, an imaging protocol and reconstruction methods are developed to generate "flow images" which depict both coherent (vascular) and incoherent (CSF) flow. An automatic technique is designed for the removal of extra-meningeal tissues, since these are known to be sources of false lesion classifications. A retrospective, three-dimensional (3D) registration algorithm is implemented to correct for patient movement which may have occurred between AFFIRMATIVE and flow imaging scans. Following application of these pre-processing steps, images are segmented into white matter, gray matter, cerebrospinal fluid, and MS lesions based on AFFIRMATIVE and flow images using an automatic algorithm. All algorithms are seamlessly integrated into a single MR image analysis software package. Lesion quantitation has been performed on images from 15 patient volunteers. The total processing time is less than two hours per patient on a SPARCstation 20. The automated nature of this approach should provide an objective means of monitoring the progression, stabilization, and/or regression of MS lesions in large-scale, multi-center clinical trials. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The intensity of long-range correlations observed with the classical HMBC pulse sequence using static optimization of the long-range coupling delay is directly related to the size of the coupling constant and is often set as a compromise. As such, some long-range correlations might appear with a reduced intensity or might even be completely absent from the spectra. After a short introduction, this third manuscript will give a detailed review of some selected HMBC variants dedicated to improve the detection of long-range correlations, such as the ACCORD-HMBC, CIGAR-HMBC, and Broadband HMBC experiments. Practical details about the accordion optimization, which affords a substantial improvement in both the number and intensity of the long-range correlations observed, but introduces a modulation in F1, will be discussed. The incorporation of the so-called constant time variable delay in the CIGAR-HMBC experiment, which can trigger or even completely suppress 1H–1H coupling modulation inherent to the utilization of the accordion principle, will be also discussed. The broadband HMBC scheme, which consists of recording a series of HMBC spectra with different delays set as a function of the long-range heteronuclear coupling constant ranges and transverse relaxation times T2, is also examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Bioinstrumentation Laboratory belongs to the Centre for Biomedical Technology (CTB) of the Technical University of Madrid and its main objective is to provide the scientific community with devices and techniques for the characterization of micro and nanostructures and consequently finding their best biomedical applications. Hyperthermia (greek word for “overheating”) is defined as the phenomenon that occurs when a body is exposed to an energy generating source that can produce a rise in temperature (42-45ºC) for a given time [1]. Specifically, the aim of the hyperthermia methods used in The Bioinstrumentation Laboratory is the development of thermal therapies, some of these using different kinds of nanoparticles, to kill cancer cells and reduce the damage on healthy tissues. The optical hyperthermia is based on noble metal nanoparticles and laser irradiation. This kind of nanoparticles has an immense potential associated to the development of therapies for cancer on account of their Surface Plasmon Resonance (SPR) enhanced light scattering and absorption. In a short period of time, the absorbed light is converted into localized heat, so we can take advantage of these characteristics to heat up tumor cells in order to obtain the cellular death [2]. In this case, the laboratory has an optical hyperthermia device based on a continuous wave laser used to kill glioblastoma cell lines (1321N1) in the presence of gold nanorods (Figure 1a). The wavelength of the laser light is 808 nm because the penetration of the light in the tissue is deeper in the Near Infrared Region. The first optical hyperthermia results show that the laser irradiation produces cellular death in the experimental samples of glioblastoma cell lines using gold nanorods but is not able to decrease the cellular viability of cancer cells in samples without the suitable nanorods (Figure 1b) [3]. The generation of magnetic hyperthermia is performed through changes of the magnetic induction in magnetic nanoparticles (MNPs) that are embedded in viscous medium. The Figure 2 shows a schematic design of the AC induction hyperthermia device in magnetic fluids. The equipment has been manufactured at The Bioinstrumentation Laboratory. The first block implies two steps: the signal selection with frequency manipulation option from 9 KHz to 2MHz, and a linear output up to 1500W. The second block is where magnetic field is generated ( 5mm, 10 turns). Finally, the third block is a software control where the user can establish initial parameters, and also shows the temperature response of MNPs due to the magnetic field applied [4-8]. The Bioinstrumentation Laboratory in collaboration with the Mexican company MRI-DT have recently implemented a new research line on Nuclear Magnetic Resonance Hyperthermia, which is sustained on the patent US 7,423,429B2 owned by this company. This investigation is based on the use of clinical MRI equipment not only for diagnosis but for therapy [9]. This idea consists of two main facts: Magnetic Resonance Imaging can cause focal heating [10], and the differentiation in resonant frequency between healthy and cancer cells [11]. To produce only heating in cancer cells when the whole body is irradiated, it is necessary to determine the specific resonant frequency of the target, using the information contained in the spectra of the area of interest. Then, special RF pulse sequence is applied to produce fast excitation and relaxation mechanism that generates temperature increase of the tumor, causing cellular death or metabolism malfunction that stops cellular division

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nesta dissertação apresentamos um trabalho de desenvolvimento e utilização de pulsos de radiofreqüência modulados simultaneamente em freqüência, amplitude e fase (pulsos fortemente modulados, SMP, do inglês Strongly Modulated Pulses) para criar estados iniciais e executar operações unitárias que servem como blocos básicos para processamento da informação quântica utilizando Ressonância Magnética Nuclear (RMN). As implementações experimentais foram realizas em um sistema de 3 q-bits constituído por spins nucleares de Césio 133 (spin nuclear 7/2) em uma amostra de cristal líquido em fase nemática. Os pulsos SMP´s foram construídos teoricamente utilizando um programa especialmente desenvolvido para esse fim, sendo o mesmo baseado no processo de otimização numérica Simplex Nelder-Mead. Através deste programa, os pulsos SMP foram otimizados de modo a executarem as operações lógicas desejadas com durações consideravelmente menores que aquelas realizadas usando o procedimento usual de RMN, ou seja, seqüências de pulsos e evoluções livres. Isso tem a vantagem de reduzir os efeitos de descoerência decorrentes da relaxação do sistema. Os conceitos teóricos envolvidos na criação dos SMPs são apresentados e as principais dificuldades (experimentais e teóricas) que podem surgir devido ao uso desses procedimentos são discutidas. Como exemplos de aplicação, foram produzidos os estados pseudo-puros usados como estados iniciais de operações lógicas em RMN, bem como operações lógicas que foram posteriormente aplicadas aos mesmos. Utilizando os SMP\'s também foi possível realizar experimentalmente os algoritmos quânticos de Grover e Deutsch-Jozsa para 3 q-bits. A fidelidade das implementações experimentais foi determinadas utilizando as matrizes densidade experimentais obtidas utilizando um método de tomografia da matriz densidade previamente desenvolvido.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laser micromachining is an important material processing technique used in industry and medicine to produce parts with high precision. Control of the material removal process is imperative to obtain the desired part with minimal thermal damage to the surrounding material. Longer pulsed lasers, with pulse durations of milli- and microseconds, are used primarily for laser through-cutting and welding. In this work, a two-pulse sequence using microsecond pulse durations is demonstrated to achieve consistent material removal during percussion drilling when the delay between the pulses is properly defined. The light-matter interaction moves from a regime of surface morphology changes to melt and vapour ejection. Inline coherent imaging (ICI), a broadband, spatially-coherent imaging technique, is used to monitor the ablation process. The pulse parameter space is explored and the key regimes are determined. Material removal is observed when the pulse delay is on the order of the pulse duration. ICI is also used to directly observe the ablation process. Melt dynamics are characterized by monitoring surface changes during and after laser processing at several positions in and around the interaction region. Ablation is enhanced when the melt has time to flow back into the hole before the interaction with the second pulse begins. A phenomenological model is developed to understand the relationship between material removal and pulse delay. Based on melt refilling the interaction region, described by logistic growth, and heat loss, described by exponential decay, the model is fit to several datasets. The fit parameters reflect the pulse energies and durations used in the ablation experiments. For pulse durations of 50 us with pulse energies of 7.32 mJ +/- 0.09 mJ, the logisitic growth component of the model reaches half maximum after 8.3 us +/- 1.1 us and the exponential decays with a rate of 64 us +/- 15 us. The phenomenological model offers an interpretation of the material removal process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rate-constrained power minimization (PMIN) over a code division multiple-access (CDMA) channel with correlated noise is studied. PMIN is. shown to be an instance of a separable convex optimization problem subject to linear ascending constraints. PMIN is further reduced to a dual problem of sum-rate maximization (RMAX). The results highlight the underlying unity between PMIN, RMAX, and a problem closely related to PMIN but with linear receiver constraints. Subsequently, conceptually simple sequence design algorithms are proposed to explicitly identify an assignment of sequences and powers that solve PMIN. The algorithms yield an upper bound of 2N - 1 on the number of distinct sequences where N is the processing gain. The sequences generated using the proposed algorithms are in general real-valued. If a rate-splitting and multi-dimensional CDMA approach is allowed, the upper bound reduces to N distinct sequences, in which case the sequences can form an orthogonal set and be binary +/- 1-valued.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sequence design problems are considered in this paper. The problem of sum power minimization in a spread spectrum system can be reduced to the problem of sum capacity maximization, and vice versa. A solution to one of the problems yields a solution to the other. Subsequently, conceptually simple sequence design algorithms known to hold for the white-noise case are extended to the colored noise case. The algorithms yield an upper bound of 2N - L on the number of sequences where N is the processing gain and L the number of non-interfering subsets of users. If some users (at most N - 1) are allowed to signal along a limited number of multiple dimensions, then N orthogonal sequences suffice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In phase encoding optical CDMA (OCDMA) the spreading is achieved by encoding the phase of signal spectrum. In this paper we first derive a mathematical model for the output of phase encoding OCDMA systems. Based on this model we introduce a metric to design spreading sequences for asynchronous transmission. Then we connect the phase encoding sequence design problem to OFDM PMEPR (peak to mean envelope power ratio) problem. Using this connection we conclude that designing sequences with good properties for samples of timing delay guarantees that the same sequence to be good for all timing delays. Finally using generalized bent function we manage to construct a family of sequences which are good for asynchronous phase encoding OCDMA systems and using these sequences we introduce an M-ary modulation scheme for phase encoding OCDMA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An in-depth understanding of biological processes often requires detailed atomic resolution structures of the molecules involved. However in solution where most of these processes occur the conformation of biomolecules like RNA, DNA and proteins is not static but fluctuates. Routinely used structural techniques like X-ray crystallography, NMR spectroscopy and cryo-electron microscopy have almost always been used to determine the structure of the dominant conformation or obtain an average structure of the biomolecule in solution with very little detailed information regarding the dynamics of these molecules in solution. Over the last few years, NMR based methods have been developed to study the dynamics of these biomolecules in solution in a site-specific manner with the aim of generating structures of the different conformations that these molecules can adopt in solution. One powerful technique is the Carr-Purcell-Meiboom-Gill (CPMG) relaxation dispersion experiment, which can be used to detect and characterize protein excited states that are populated for as less as 0.5% of the time with ∼0.5–10 millisecond lifetimes. Due to recent advances in NMR pulse sequences and labeling methodology, it is now possible to determine the structures of these transiently populated excited states with millisecond lifetimes by obtaining accurate chemical shifts, residual dipolar couplings (RDCs) and residual chemical shift anisotropies (RCSAs) of these excited states. In these excited states the dynamics of some methyl containing residues can also be studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PurposeTo extend the previously developed temporally constrained reconstruction (TCR) algorithm to allow for real-time availability of three-dimensional (3D) temperature maps capable of monitoring MR-guided high intensity focused ultrasound applications. MethodsA real-time TCR (RT-TCR) algorithm is developed that only uses current and previously acquired undersampled k-space data from a 3D segmented EPI pulse sequence, with the image reconstruction done in a graphics processing unit implementation to overcome computation burden. Simulated and experimental data sets of HIFU heating are used to evaluate the performance of the RT-TCR algorithm. ResultsThe simulation studies demonstrate that the RT-TCR algorithm has subsecond reconstruction time and can accurately measure HIFU-induced temperature rises of 20 degrees C in 15 s for 3D volumes of 16 slices (RMSE = 0.1 degrees C), 24 slices (RMSE = 0.2 degrees C), and 32 slices (RMSE = 0.3 degrees C). Experimental results in ex vivo porcine muscle demonstrate that the RT-TCR approach can reconstruct temperature maps with 192 x 162 x 66 mm 3D volume coverage, 1.5 x 1.5 x 3.0 mm resolution, and 1.2-s scan time with an accuracy of 0.5 degrees C. ConclusionThe RT-TCR algorithm offers an approach to obtaining large coverage 3D temperature maps in real-time for monitoring MR-guided high intensity focused ultrasound treatments. Magn Reson Med 71:1394-1404, 2014. (c) 2013 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

针对啁啾脉冲放大技术建成的钛宝石激光装置,提出一种获得高重复率激光脉冲列的方法.通过改变钛宝石再生放大器中泡克耳斯盒电光开关的传统工作模式,使得腔内放大的脉冲从某特定时刻起,每当在腔内往返一次就以一定的倒出比例(倒出率)倒出腔内脉冲能量的一部分,从而可以在有限的时间段内产生高重复率的啁啾激光脉冲列.基于Franz-Nodvik放大理论,建立了该高重复率再生放大器的理论模型,通过数值计算,系统地分析了初始增益、倒出时刻、倒出率对输出的脉冲序列的影响.在抽运功率为35mJ、倒出率为1/2的实验条件下,通过腔外

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Algorithmic DNA tiles systems are fascinating. From a theoretical perspective, they can result in simple systems that assemble themselves into beautiful, complex structures through fundamental interactions and logical rules. As an experimental technique, they provide a promising method for programmably assembling complex, precise crystals that can grow to considerable size while retaining nanoscale resolution. In the journey from theoretical abstractions to experimental demonstrations, however, lie numerous challenges and complications.

In this thesis, to examine these challenges, we consider the physical principles behind DNA tile self-assembly. We survey recent progress in experimental algorithmic self-assembly, and explain the simple physical models behind this progress. Using direct observation of individual tile attachments and detachments with an atomic force microscope, we test some of the fundamental assumptions of the widely-used kinetic Tile Assembly Model, obtaining results that fit the model to within error. We then depart from the simplest form of that model, examining the effects of DNA sticky end sequence energetics on tile system behavior. We develop theoretical models, sequence assignment algorithms, and a software package, StickyDesign, for sticky end sequence design.

As a demonstration of a specific tile system, we design a binary counting ribbon that can accurately count from a programmable starting value and stop growing after overflowing, resulting in a single system that can construct ribbons of precise and programmable length. In the process of designing the system, we explain numerous considerations that provide insight into more general tile system design, particularly with regards to tile concentrations, facet nucleation, the construction of finite assemblies, and design beyond the abstract Tile Assembly Model.

Finally, we present our crystals that count: experimental results with our binary counting system that represent a significant improvement in the accuracy of experimental algorithmic self-assembly, including crystals that count perfectly with 5 bits from 0 to 31. We show some preliminary experimental results on the construction of our capping system to stop growth after counters overflow, and offer some speculation on potential future directions of the field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Parametric fluctuations or stochastic signals are introduced into the rectangular pulse sequence to investigate the feasibility of random dynamical decoupling. In a large parameter region, we find that the out-of-order control pulses work as well as the regular pulses for dynamical decoupling and dissipation suppression. Calculations and analysis are enabled by and based on a nonperturbative dynamical decoupling approach allowed by an exact quantum-state-diffusion equation. When the average frequency and duration of the pulse sequence take proper values, the random control sequence is robust, fault-tolerant, and insensitive to pulse strength deviations and interpulse temporal separation in the quasi-periodic sequence. This relaxes the operational requirements placed on quantum control devices to a great deal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

为了满足单模尾纤输出脉冲半导体激光器及其后级光放大的要求,研制了一种重频、脉宽及峰值电流均连续可调的纳秒脉冲驱动电源。该电源使用功率场效应管作为开关,通过分析其驱动特性,采用合适的栅极驱动电路,从而缩短了脉冲宽度,增加了带负载能力;同时电源中的保护电路采用自断电等保护措施,能有效保证LD的安全工作。实验结果表明,该驱动电源工作稳定,能满足单模尾纤输出脉冲LD重频、脉宽、峰值可调的要求。