959 resultados para Multiple-target sputtering
Resumo:
Hypoxia-inducible factor-1 alpha (HIF-1α) plays a critical role in survival and is associated with poor prognosis in solid tumors. The role of HIF-1α in multiple myeloma is not completely known. In the present study, we explored the effect of EZN2968, an locked nucleic acid antisense oligonucleotide against HIF-1α, as a molecular target in MM. A panel of MM cell lines and primary samples from MM patients were cultured in vitro in the presence of EZN2968 . Under normoxia culture condition, HIF-1α mRNA and protein expression was detectable in all MM cell lines and in CD138+ cells from newly diagnosed MM patients samples. Significant up-regulation of HIF-1α protein expression was observed after incubation with IL6 or IGF-I, confirming that HIF-1α can be further induced by biological stimuli. EZN2968 efficiently induces a selective and stable down-modulation of HIF-1α and decreased the secretion of VEGF released by MM cell. Treatment with EZN2968 gave rise to a progressive accumulation of cells in the S and subG0 phase. The analysis of p21, a cyclin-dependent kinase inhibitors controlling cell cycle check point, shows upregulation of protein levels. These results suggest that HIF-1α inhibition is sufficient for cell cycle arrest in normoxia, and for inducing an apoptotic pathways.. In the presence of bone marrow microenvironment, HIF-1α inhibition blocks MAPK kinase pathway and secretion of pro-surviaval cytokines ( IL6,VEGF,IL8) In this study we provide evidence that HIF-1α, even in the absence of hypoxia signal, is expressed in MM plasma cells and further inducible by bone marrow milieu stimuli; moreover its inhibition is sufficient to induce a permanent cell cycle arrest. Our data support the hypothesis that HIF-1α inhibition may suppress tumor growth by preventing proliferation of plasma cells through p21 activation and blocking pro-survival stimuli from bone marrow microenvironment.
Resumo:
In sports games, it is often necessary to perceive a large number of moving objects (e.g., the ball and players). In this context, the role of peripheral vision for processing motion information in the periphery is often discussed especially when motor responses are required. In an attempt to test the basal functionality of peripheral vision in those sports-games situations, a Multiple Object Tracking (MOT) task that requires to track a certain number of targets amidst distractors, was chosen. Participants’ primary task was to recall four targets (out of 10 rectangular stimuli) after six seconds of quasi-random motion. As a second task, a button had to be pressed if a target change occurred (Exp 1: stop vs. form change to a diamond for 0.5 s; Exp 2: stop vs. slowdown for 0.5 s). While eccentricities of changes (5-10° vs. 15-20°) were manipulated, decision accuracy (recall and button press correct), motor response time as well as saccadic reaction time were calculated as dependent variables. Results show that participants indeed used peripheral vision to detect changes, because either no or very late saccades to the changed target were executed in correct trials. Moreover, a saccade was more often executed when eccentricities were small. Response accuracies were higher and response times were lower in the stop conditions of both experiments while larger eccentricities led to higher response times in all conditions. Summing up, it could be shown that monitoring targets and detecting changes can be processed by peripheral vision only and that a monitoring strategy on the basis of peripheral vision may be the optimal one as saccades may be afflicted with certain costs. Further research is planned to address the question whether this functionality is also evident in sports tasks.
Resumo:
In sports games, it is often necessary to perceive a large number of moving objects (e.g., the ball and players). In this context, the role of peripheral vision for processing motion information in the periphery is often discussed especially when motor responses are required. In an attempt to test the capability of using peripheral vision in those sports-games situations, a Multiple-Object-Tracking task that requires to track a certain number of targets amidst distractors, was chosen to determine the sensitivity of detecting target changes with peripheral vision only. Participants’ primary task was to recall four targets (out of 10 rectangular stimuli) after six seconds of quasi-random motion. As a second task, a button had to be pressed if a target change occurred (Exp 1: stop vs. form change to a diamond for 0.5 s; Exp 2: stop vs. slowdown for 0.5 s). Eccentricities of changes (5-10° vs. 15-20°) were manipulated, decision accuracy (recall and button press correct), motor response time and saccadic reaction time (change onset to saccade onset) were calculated and eye-movements were recorded. Results show that participants indeed used peripheral vision to detect changes, because either no or very late saccades to the changed target were executed in correct trials. Moreover, a saccade was more often executed when eccentricities were small. Response accuracies were higher and response times were lower in the stop conditions of both experiments while larger eccentricities led to higher response times in all conditions. Summing up, it could be shown that monitoring targets and detecting changes can be processed by peripheral vision only and that a monitoring strategy on the basis of peripheral vision may be the optimal one as saccades may be afflicted with certain costs. Further research is planned to address the question whether this functionality is also evident in sports tasks.
Resumo:
In the current study it is investigated whether peripheral vision can be used to monitor multi-ple moving objects and to detect single-target changes. For this purpose, in Experiment 1, a modified MOT setup with a large projection and a constant-position centroid phase had to be checked first. Classical findings regarding the use of a virtual centroid to track multiple ob-jects and the dependency of tracking accuracy on target speed could be successfully replicat-ed. Thereafter, the main experimental variations regarding the manipulation of to-be-detected target changes could be introduced in Experiment 2. In addition to a button press used for the detection task, gaze behavior was assessed using an integrated eye-tracking system. The anal-ysis of saccadic reaction times in relation to the motor response shows that peripheral vision is naturally used to detect motion and form changes in MOT because the saccade to the target occurred after target-change offset. Furthermore, for changes of comparable task difficulties, motion changes are detected better by peripheral vision than form changes. Findings indicate that capabilities of the visual system (e.g., visual acuity) affect change detection rates and that covert-attention processes may be affected by vision-related aspects like spatial uncertainty. Moreover, it is argued that a centroid-MOT strategy might reduce the amount of saccade-related costs and that eye-tracking seems to be generally valuable to test predictions derived from theories on MOT. Finally, implications for testing covert attention in applied settings are proposed.
Resumo:
In this work, we analyze the influence of the processing pressure and the substrate–target distance on the synthesis by reactive sputtering of c-axis oriented polycrystalline aluminum nitride thin films deposited on Si(100) wafers. The crystalline quality of AlN has been characterized by high-resolution X-ray diffraction (HR-XRD). The films exhibited a very high degree of c-axis orientation especially when a low process pressure was used. After growth, residual stress measurements obtained indirectly from radius of curvature measurements of the wafer prior and after deposition are also provided. Two different techniques are used to determine the curvature—an optically levered laser beam and a method based on X-ray diffraction. There is a transition from compressive to tensile stress at a processing pressure around 2 mTorr. The transition occurs at different pressures for thin films of different thickness. The degree of c-axis orientation was not affected by the target–substrate distance as it was varied in between 30 and 70 mm.
Resumo:
This paper discusses the target localization problem in wireless visual sensor networks. Additive noises and measurement errors will affect the accuracy of target localization when the visual nodes are equipped with low-resolution cameras. In the goal of improving the accuracy of target localization without prior knowledge of the target, each node extracts multiple feature points from images to represent the target at the sensor node level. A statistical method is presented to match the most correlated feature point pair for merging the position information of different sensor nodes at the base station. Besides, in the case that more than one target exists in the field of interest, a scheme for locating multiple targets is provided. Simulation results show that, our proposed method has desirable performance in improving the accuracy of locating single target or multiple targets. Results also show that the proposed method has a better trade-off between camera node usage and localization accuracy.
Resumo:
"December 1989."
Resumo:
In this study, we developed a DEA-based performance measurement methodology that is consistent with performance assessment frameworks such as the Balanced Scorecard. The methodology developed in this paper takes into account the direct or inverse relationships that may exist among the dimensions of performance to construct appropriate production frontiers. The production frontiers we obtained are deemed appropriate as they consist solely of firms with desirable levels for all dimensions of performance. These levels should be at least equal to the critical values set by decision makers. The properties and advantages of our methodology against competing methodologies are presented through an application to a real-world case study from retail firms operating in the US. A comparative analysis between the new methodology and existing methodologies explains the failure of the existing approaches to define appropriate production frontiers when directly or inversely related dimensions of performance are present and to express the interrelationships between the dimensions of performance.
Resumo:
In this paper we analyze the structure of Fe-Ga layers with a Ga content of ∼30 at.% deposited by the sputtering technique under two different regimes. We also studied the correlation between the structure and magnetic behavior of the samples. Keeping the Ar pressure fixed, we modified the flow regime from ballistic to diffusive by increasing the distance between the target and the substrate. X-ray diffraction measurements have shown a lower structural quality when growing in the diffusive flow. We investigated the impact of the growth regime by means of x-ray absorption fine structure (XAFS) measurements and obtained signs of its influence on the local atomic order. Full multiple scattering and finite difference calculations based on XAFS measurements point to a more relevant presence of a disordered A2 phase and of orthorhombic Ga clusters on the Fe-Ga alloy deposited under a diffusive regime; however, in the ballistic sample, a higher presence of D0_3/B2 phases is evidenced. Structural characteristics, from local to long range, seem to determine the magnetic behavior of the layers. Whereas a clear in-plane magnetic anisotropy is observed in the film deposited under ballistic flow, the diffusive sample is magnetically isotropic. Therefore, our experimental results provide evidence of a correlation between flow regime and structural properties and its impact on the magnetic behavior of a rather unexplored compositional region of Fe-Ga compounds.
Resumo:
The hypervariable regions of immunoglobulin heavy-chain (IgH) rearrangements provide a specific tumor marker in multiple myeloma (MM). Recently, real-time PCR assays have been developed in order to quantify the number of tumor cells after treatment. However, these strategies are hampered by the presence of somatic hypermutation (SH) in VDJH rearrangements from multiple myeloma (MM) patients, which causes mismatches between primers and/or probes and the target, leading to a nonaccurate quantification of tumor cells. Our group has recently described a 60% incidence of incomplete DJH rearrangements in MM patients, with no or very low rates of SH. In this study, we compare the efficiency of a real-time PCR approach for the analysis of both complete and incomplete IgH rearrangements in eight MM patients using only three JH consensus probes. We were able to design an allele-specific oligonucleotide for both the complete and incomplete rearrangement in all patients. DJH rearrangements fulfilled the criteria of effectiveness for real-time PCR in all samples (ie no unspecific amplification, detection of less than 10 tumor cells within 10(5) polyclonal background and correlation coefficients of standard curves higher than 0.98). By contrast, only three out of eight VDJH rearrangements fulfilled these criteria. Further analyses showed that the remaining five VDJH rearrangements carried three or more somatic mutations in the probe and primer sites, leading to a dramatic decrease in the melting temperature. These results support the use of incomplete DJH rearrangements instead of complete somatically mutated VDJH rearrangements for investigation of minimal residual disease in multiple myeloma.
Resumo:
BACKGROUND AND PURPOSE: To assess the impact of a standardized delineation protocol and training interventions on PET/CT-based target volume delineation (TVD) in NSCLC in a multicenter setting.
MATERIAL AND METHODS: Over a one-year period, 11 pairs, comprised each of a radiation oncologist and nuclear medicine physician with limited experience in PET/CT-based TVD for NSCLC from nine different countries took part in a training program through an International Atomic Energy Agency (IAEA) study (NCT02247713). Teams delineated gross tumor volume of the primary tumor, during and after training interventions, according to a provided delineation protocol. In-house developed software recorded the performed delineations, to allow visual inspection of strategies and to assess delineation accuracy.
RESULTS: Following the first training, overall concordance indices for 3 repetitive cases increased from 0.57±0.07 to 0.66±0.07. The overall mean surface distance between observer and expert contours decreased from -0.40±0.03 cm to -0.01±0.33 cm. After further training overall concordance indices for another 3 repetitive cases further increased from 0.64±0.06 to 0.80±0.05 (p=0.01). Mean surface distances decreased from -0.34±0.16 cm to -0.05±0.20 cm (p=0.01).
CONCLUSION: Multiple training interventions improve PET/CT-based TVD delineation accuracy in NSCLC and reduces interobserver variation.