389 resultados para Multicomponent


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the design and assembly of multifunctional and cost-efficient composite fiber nonwovens as semi-occlusive wound dressings using a simple electrospinning process to incorporate a variety Of functional components into an Ultrathin fiber. These components include non-hydrophilic poly(L-lactide) (PLLA) as fibrous backbone, hydrophilic poly(vinyl pyrrolidone)iodine (PVP-I), TiO2 nanoparticles, zinc chloride as antimicrobial, odor-controlling, and antiphlogistic agents, respectively. The process of synthesis starts with a multicomponent solution Of PLLA, PVP, TiO2 nanoparticles plus zinc chloride, in which TiO2 nanoparticles are synthesized by in situ hydrolysis of TiO2 precursors in a PVP Solution for the sake of obtaining the particle-uniformly dispersive solution. Subsequent electrospinning generates the corresponding composite fibers. A further iodine vapor treatment to the composite fibers combines iodine with PVP to produce the PVP-I complexes. Experiments indicate that the assembled composite fibers (300-400 nm) possess the ointment-releasing characteristic and the phase-separate, core-sheath structures in which PVP-I residing in fiber Surface layer becomes the sheath, and PLLA distributing inside the fiber acts as the core.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of Li content in a series of multicomponent oxides LixLa0.5Ti0.5 For methane oxidative coupling has been studied. The catalytic activities of LiLa0.5Ti0.5 catalyst before and after washing with boiling water have been compared. The surface and

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports some definite evidence for the significance of wavelength positioning accuracy in multicomponent analysis techniques for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). Using scanning spectrometers commercially available today, a large relative error, DELTA(A) may occur in the estimated analyte concentration, owing to wavelength positioning errors, unless a procedure for data processing can eliminate the problem of optical instability. The emphasis is on the effect of the positioning error (deltalambda) in a model scan, which is evaluated theoretically and determined experimentally. A quantitative relation between DELTA(A) and deltalambda, the peak distance, and the effective widths of the analysis and interfering lines is established under the assumption of Gaussian line profiles. The agreement between calculated and experimental DELTA(A) is also illustrated. The DELTA(A) originating from deltalambda is independent of the net analyte/interferent signal ratio; this contrasts with the situation for the positioning error (dlambda) in a sample scan, where DELTA(A) decreases with an increase in the ratio. Compared with dlambda, the effect of deltalambda is generally less significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the evaluation of the relative error (DELTA(A)) in estimated analyte concentrations originating from the wavelength positioning error in a sample scan when multicomponent analysis (MCA) techniques are used for correcting line interferences in inductively coupled plasma atomic emission spectrometry. In the theoretical part, a quantitative relation of DELTA(A) with the extent of line overlap, bandwidth and the magnitude of the positioning error is developed under the assumption of Gaussian line profiles. The measurements of eleven samples covering various typical line interferences showed that the calculated DELTA(A) generally agrees well with the experimental one. An expression of the true detection limit associated with MCA techniques was thus formulated. With MCA techniques, the determination of the analyte and interferent concentrations depend on each other while with conventional correction techniques, such as the three-point method, the estimate of interfering signals is independent of the analyte signals. Therefore. a given positioning error results in a larger DELTA(A) and hence a higher true detection limit in the case of MCA techniques than that in the case of conventional correction methods. although the latter could be a reasonable approximation of the former when the peak distance expressed in the effective width of the interfering line is larger than 0.4. In the light of the effect of wavelength positioning errors, MCA techniques have no advantages over conventional correction methods unless the former can bring an essential reduction ot the positioning error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absorption spectra of W, Mo and Ti-phenylfluorone cetyltrimethylammonium bromide complexes and the optimum conditions for the simultaneous spectrophotometric determination of microamounts of W, Mo and Ti were studied. In order to examine the effect of the errors of calibration matrix on the analytical resulte, the approach of selecting the analytical wavelengths was investigated and the comparison of computation results between AKC method (the matrix representation of Beer-Lambert's Law) and ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Electronic Nose is being jointly developed between the University of Greenwich and the Institute of Intelligent Machines to detect the gases given off from an oil filled transformer when it begins to break down. The gas sensors being used are very simple, consisting of a layer of Tin Oxide (SnO2) which is heated to approximately 640 K and the conductivity varies with the gas concentrations. Some of the shortcomings introduced by the commercial gas sensors available are being overcome by the use of an integrated array of gas sensors and the use of artificial neural networks which can be 'taught' to recognize when the gas contains several components. At present simulated results have achieved up to a 94% success rate of recognizing two component gases and future work will investigate alternative neural network configurations to maintain this success rate with practical measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Size-fractionated filtration (SFF) is a direct method for estimating pigment concentration in various size classes. It is also common practice to infer the size structure of phytoplankton communities from diagnostic pigments estimated by high-performance liquid chromatography (HPLC). In this paper, the three-component model of Brewin et al. (2010) was fitted to coincident data from HPLC and from SFF collected along Atlantic Meridional Transect cruises. The model accounted for the variability in each data set, but the fitted model parameters differed for the two data sets. Both HPLC and SFF data supported the conceptual framework of the three-component model, which assumes that the chlorophyll concentration in small cells increases to an asymptotic maximum, beyond which further increase in chlorophyll is achieved by the addition of larger celled phytoplankton. The three-component model was extended to a multicomponent model of size structure using observed relationships between model parameters and assuming that the asymptotic concentration that can be reached by cells increased linearly with increase in the upper bound on the cell size. The multicomponent model was verified using independent SFF data for a variety of size fractions and found to perform well (0.628 ≤ r ≤ 0.989) lending support for the underlying assumptions. An advantage of the multicomponent model over the three-component model is that, for the same number of parameters, it can be applied to any size range in a continuous fashion. The multicomponent model provides a useful tool for studying the distribution of phytoplankton size structure at large scales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine the extent to which the use of a clinical informatics tool that implements prospective monitoring plans reduces the incidence of potential delirium, falls, hospitalizations potentially due to adverse drug events, and mortality.

DESIGN: Randomized cluster trial.

SETTING: Twenty-five nursing homes serviced by two long-term care pharmacies.

PARTICIPANTS: Residents living in nursing homes during 2003 (1,711 in 12 intervention; 1,491 in 13 usual care) and 2004 (1,769 in 12 intervention; 1,552 in 13 usual care).

INTERVENTION: The pharmacy automatically generated Geriatric Risk Assessment MedGuide (GRAM) reports and automated monitoring plans for falls and delirium within 24 hours of admission or as part of the normal time frame of federally mandated drug regimen review.

MEASUREMENTS: Incidence of potential delirium, falls, hospitalizations potentially due to adverse drug events, and mortality.

RESULTS: GRAM triggered monitoring plans for 491 residents. Newly admitted residents in the intervention homes experienced a lower rate of potential delirium onset than those in usual care homes (adjusted hazard ratio (HR)=0.42, 95% confidence interval (CI)=0.35–0.52), overall hospitalization (adjusted HR=0.89, 95% CI=0.72–1.09), and mortality (adjusted HR=0.88, 95% CI=0.66–1.16). In longer stay residents, the effects of the intervention were attenuated, and all estimates included unity.

CONCLUSION: Using health information technology in long-term care pharmacies to identify residents who might benefit from the implementation of prospective medication monitoring care plans when complex medication regimens carry potential risks for falls and delirium may reduce adverse effects associated with appropriate medication use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A printable, multicomponent, UV-sensitive indicator which provides different coloured, flag-like warnings of the approach to erythema is described.