918 resultados para Multi-phase experiments


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The central product of the DRAMA (Dynamic Re-Allocation of Meshes for parallel Finite Element Applications) project is a library comprising a variety of tools for dynamic re-partitioning of unstructured Finite Element (FE) applications. The input to the DRAMA library is the computational mesh, and corresponding costs, partitioned into sub-domains. The core library functions then perform a parallel computation of a mesh re-allocation that will re-balance the costs based on the DRAMA cost model. We discuss the basic features of this cost model, which allows a general approach to load identification, modelling and imbalance minimisation. Results from crash simulations are presented which show the necessity for multi-phase/multi-constraint partitioning components.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The main purpose of this study is to evaluate the best set of features that automatically enables the identification of argumentative sentences from unstructured text. As corpus, we use case laws from the European Court of Human Rights (ECHR). Three kinds of experiments are conducted: Basic Experiments, Multi Feature Experiments and Tree Kernel Experiments. These experiments are basically categorized according to the type of features available in the corpus. The features are extracted from the corpus and Support Vector Machine (SVM) and Random Forest are the used as Machine learning algorithms. We achieved F1 score of 0.705 for identifying the argumentative sentences which is quite promising result and can be used as the basis for a general argument-mining framework.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The research project aims to study and develop control techniques for a generalized three-phase and multi-phase electric drive able to efficiently manage most of the drive types available for traction application. The generalized approach is expanded to both linear and non- linear machines in magnetic saturation region starting from experimental flux characterization and applying the general inductance definition. The algorithm is able to manage fragmented drives powered from different batteries or energy sources and will be able to ensure operability even in case of faults in parts of the system. The algorithm was tested using model-in-the-loop in software environment and then applied on experimental test benches with collaboration of an external company.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Many images consist of two or more 'phases', where a phase is a collection of homogeneous zones. For example, the phases may represent the presence of different sulphides in an ore sample. Frequently, these phases exhibit very little structure, though all connected components of a given phase may be similar in some sense. As a consequence, random set models are commonly used to model such images. The Boolean model and models derived from the Boolean model are often chosen. An alternative approach to modelling such images is to use the excursion sets of random fields to model each phase. In this paper, the properties of excursion sets will be firstly discussed in terms of modelling binary images. Ways of extending these models to multi-phase images will then be explored. A desirable feature of any model is to be able to fit it to data reasonably well. Different methods for fitting random set models based on excursion sets will be presented and some of the difficulties with these methods will be discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We derive a general thermo-mechanical theory for particulate materials consisting of granules of arbitrary whose material points possess three translational and three independent rotational degrees of freedom. Additional field variables are the translational and rotational granular temperatures, the kinetic energies shape and size. The kinematics of granulate is described within the framework of a polar continuum theory of the velocity and spin fluctuations respectively and the usual thermodynamic temperature. We distinguish between averages over particle categories (averages in mass/velocity and moment of inertia/spin space, respectively) and particle phases where the average extends over distinct subsets of particle categories (multi phase flows). The relationship between the thermal energy in the granular system and phonon energy in a molecular system is briefly discussed in the main body of the paper and discussed in detail in the Appendix A. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Different abrasive wear tests have been applied to materials with hardnesses ranging from 80 HV (aluminium) to 1700 HV (tungsten carbide). The tests were: dry sand rubber wheel (DSRbrW); a similar test using a steel wheel (DSStlW); a new combined impact-abrasion test (FIA). The DSRbrW results were as expected, giving generally decreasing wear with increasing hardness. White cast irons and tool steels containing coarse, hard carbide particles performed better than more homogeneous materials of comparable hardness. When normalized to load and distance, the DSStlW results for the homogeneous materials were similar to the DSRbrW results. The multi-phase materials performed poorly in the DSStlW test, with volume loss for high-speed steel (880 HV) higher than that of aluminium. Within this group, wear increased with increasing hardness. These unexpected results are explained in terms of (a) differential friction coefficients of wheel and specimen, (b) increased fracture of sand, and (c) introduction of microfracture wear mechanisms. The FIA combined impact-abrasion results lacked clear correlations with hardness. The span of relative wear rates was similar to that reported for materials in ball mills. White cast irons at maximum hardness performed fairly poorly and showed evidence of microfracture. (C) 1997 Elsevier Science S.A.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report the results of the growth of Cu-Sn-S ternary chalcogenide compounds by sulfurization of dc magnetron sputtered metallic precursors. Tetragonal Cu2SnS3 forms for a maximum sulfurization temperature of 350 ºC. Cubic Cu2SnS3 is obtained at sulfurization temperatures above 400 ºC. These results are supported by XRD analysis and Raman spectroscopy measurements. The latter analysis shows peaks at 336 cm-1, 351 cm-1 for tetragonal Cu2SnS3, and 303 cm-1, 355 cm-1 for cubic Cu2SnS3. Optical analysis shows that this phase change lowers the band gap from 1.35 eV to 0.98 eV. At higher sulfurization temperatures increased loss of Sn is expected in the sulphide form. As a consequence, higher Cu content ternary compounds like Cu3SnS4 grow. In these conditions, XRD and Raman analysis only detected orthorhombic (Pmn21) phase (petrukite). This compound has Raman peaks at 318 cm-1, 348 cm-1 and 295 cm-1. For a sulfurization temperature of 450 ºC the samples present a multi-phase structure mainly composed by cubic Cu2SnS3 and orthorhombic (Pmn21) Cu3SnS4. For higher temperatures, the samples are single phase and constituted by orthorhombic (Pmn21) Cu3SnS4. Transmittance and reflectance measurements were used to estimate a band gap of 1.60 eV. For comparison we also include the results for Cu2ZnSnS4 obtained using similar growth conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cu2ZnSnS4 (CZTS) is a p-type semiconductor that has been seen as a possible low-cost replacement for Cu(In,Ga)Se2 in thin film solar cells. So far compound has presented difficulties in its growth, mainly, because of the formation of secondary phases like ZnS, CuxSnSx+1, SnxSy, Cu2−xS and MoS2. X-ray diffraction analysis (XRD), which is mostly used for phase identification cannot resolve some of these phases from the kesterite/stannite CZTS and thus the use of a complementary technique is needed. Raman scattering analysis can help distinguishing these phases not only laterally but also in depth. Knowing the absorption coefficient and using different excitation wavelengths in Raman scattering analysis, one is capable of profiling the different phases present in multi-phase CZTS thin films. This work describes in a concise form the methods used to grow chalcogenide compounds, such as, CZTS, CuxSnSx+1, SnxSy and cubic ZnS based on the sulphurization of stacked metallic precursors. The results of the films’ characterization by XRD, electron backscatter diffraction and scanning electron microscopy/energy dispersive spectroscopy techniques are presented for the CZTS phase. The limitation of XRD to identify some of the possible phases that can remain after the sulphurization process are investigated. The results of the Raman analysis of the phases formed in this growth method and the advantage of using this technique in identifying them are presented. Using different excitation wavelengths it is also analysed the CZTS film in depth showing that this technique can be used as non destructive methods to detect secondary phases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The last decade has witnessed an increased research effort on multi-phase magnetoelectric (ME) composites. In this scope, this paper presents the application of novel materials for the development of anisotropic magnetoelectric (ME) sensors based on δ-FeO(OH)/P(VDF-TrFE) composites. The composite is able to precisely determine the amplitude and direction of the magnetic field. A new ME effect is reported in this study, as it emerges from the magnetic rotation of the δ-FeO(OH) nanosheets inside the piezoelectric P(VDF-TrFE) polymer matrix. δ-FeO(OH)/P(VDF-TrFE) composites with 1, 5, 10 and 20 δ-FeO(OH) filler weigh percentage in three δ-FeO(OH) alignment states (random, transversal and longitudinal) have been developed. Results shown that the modulus of the piezoelectric response (10-24 pC.N-1) is stable at least up to three months, the shape and magnetization maximum value (3 emu.g-1) is dependent on δ-FeO(OH) content and the obtained ME voltage coefficient, with a maximum of ≈0.4 mV.cm-1.Oe-1, is dependent on the incident magnetic field direction and intensity. In this way, the produced materials are suitable for innovative anisotropic sensor and actuator applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Staphylococcus aureus is a highly successful pathogen responsible of a wide variety of diseases, from minor skin infection to life-threatening sepsis or infective endocarditis, as well as food poisoning and toxic shock syndrome. This heterogeneity of infections and the ability of S. aureus to develop antibiotic-resistance to virtually any available drugs reflect its extraordinary capacity to adapt and survive in a great variety of environments. The pathogenesis of S. aureus infection involves a wide range of cell wall-associated adhesins and extracellular toxins that promote host colonization and invasion. In addition, S. aureus is extremely well equipped with regulatory systems that sense environmental conditions and respond by fine tuning the expression of metabolic and virulence determinants. Surface adhesins referred to MSCRAMMs - for Microbial Surface Component Recognizing Adherence Matrix Molecules - mediate binding to the host extracellular matrix or serum components, including fibrinogen, fibronectin, collagen and elastin, and promote tissue colonization and invasion. Major MSCRAMMs include a family of surface-attached proteins covalently bound to the cell wall peptidoglycan via a conserved LPXTG motif. Genomic analyses indicate that S. aureus contain up to 22 LPXTG surface proteins, which could potentially act individually or in synergy to promote infection. In the first part of this study we determined the range of adherence phenotypes to fibrinogen and fibronectin among 30 carriage isolates of S. aureus and compared it to the adherence phenotypes of 30 infective endocarditis and 30 blood culture isolates. Overall there were great variations in in vitro adherence, but no differences were observed between carriage and infection strains. We further determined the relation between in vitro adherence and in vivo infectivity in a rat model of experimental endocarditis, using 4 isolates that displayed either extremely low or high adherence phenotypes. Unexpectedly, no differences were observed between the in vivo infectivity of isolates that were poorly and highly adherent in vitro. We concluded that the natural variability of in vitro adherence to fibrinogen and fibronectin did not correlate with in vivo infectivity, and thus that pathogenic differences between various strains might only be expressed in in vivo conditions, but not in vitro. Therefore, considering the importance of adhesins expression for infection, direct measurement of those adhesins present on the bacterial surface were made by proteomic approach. 5 In the second series of experiments we assessed the physical presence of the LPXTG species at the staphylococcal surface, as measured at various time points during growth in different culture media. S. aureus Newman was grown in either tryptic soy broth (TSB) or in Roswell Park Memorial Institute (RPMI) culture medium, and samples were removed from early exponential growth phase to late stationary phase. Experiments were performed with mutants in the global accessory-gene regulator (agr), surface protein A (Spa) and clumping factor A (ClfA). Peptides of surface proteins were recovered by "trypsin-shaving" of live bacteria, and semi-quantitative proteomic analysis was performed by tandem liquid-chromatography and mass-spectrometry (LC-MS). We also determined in parallel the mRNA expression by microarrays analysis, as well as the phenotypic adherence of the bacteria to fibrinogen in vitro. The surface proteome was highly complex and contained numerous proteins theoretically not belonging to the bacterial envelope, including ribosomal proteins and metabolic enzymes. Sixteen of the 21 known LPXTG species were detected, but were differentially expressed. As expected, 9 known agr-regulated proteins (e.g. including Spa, FnBPA, ClfA, IsdA, IsdB, SasH, SasD, SasG and FmtB) increased up to the late exponential growth phase, and were abrogated in agr-negative mutants. However, only Spa and SasH modified their proteomic and mRNA profiles in parallel in the parent and its agr negative mutant, while all other LPXTG proteins modified their proteomic profiles independently of their mRNA. Moreover, ClfA became highly transcribed and active in in vitro fibrinogen adherence tests during late growth (24h), whereas it remained poorly detected by proteomics. Differential expression was also detected in iron-rich TSB versus iron-poor RPMI. Proteins from the iron-regulated surface determinant (isd) system, including IsdA, IsdB and IsdH were barely expressed in iron-rich TSB, whereas they increased their expression by >10 time in iron-poor RPMI. We conclude that semi-quantitative proteomic analysis of specific protein species is feasible in S. aureus and that proteomic, transcriptomic and adherence phenotypes demonstrated differential profiles in S. aureus. Furthermore, peptide signatures released by trypsin shaving suggested differential protein domain exposures in various environments, which might be relevant for antiadhesins vaccines. A comprehensive understanding of the S. aureus physiology should integrate all these approaches.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Investigation of violent death, especially cases of sharp trauma and gunshot, is an important part of medico-legal investigations. Beside the execution of a conventional autopsy, the performance of a post-mortem Multi-Detector Computed Tomography (MDCT)-scan has become a highly appreciated tool. In order to investigate also the vascular system, post-mortem CT-angiography has been introduced. The most studied and widespread technique is the Multi-phase post-mortem CT-angiography (MPMCTA). Its sensitivity to detect vascular lesions is even superior to conventional autopsy. The application of MPMCTA for cases of gunshot and sharp-trauma is therefore an obvious choice, as vascular lesions are common in such victims. In most cases of sharp trauma and in several cases of gunshots, death can be attributed to exsanguinations. MPMCTA is able to detect the exact source of bleeding and also to visualize trajectories, which are of most importance in these cases. The reconstructed images allow to clearly visualizing the trajectory in a way that is easily comprehensible for not medically trained legal professionals. The sensitivity of MPMCTA for soft tissue and organ lesions approximately matches the sensitivity of conventional autopsy. However, special care, experience and effective use of the imaging software is necessary for performing the reconstructions of the trajectory. Large volume consuming haemorrhages and shift of inner organs are sources of errors and misinterpretations. This presentation shall give an overview about the advantages and limitations of the use of MPMCTA for investigating cases of gunshot and sharp-trauma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to compare the diagnostic value of post-mortem computed tomography angiography (PMCTA) to conventional, ante-mortem computed tomography (CT)-scan, CT-angiography (CTA) and digital subtraction angiography (DSA) in the detection and localization of the source of bleeding in cases of acute hemorrhage with fatal outcomes. The medical records and imaging scans of nine individuals who underwent a conventional, ante-mortem CT-scan, CTA or DSA and later died in the hospital as a result of an acute hemorrhage were reviewed. Post-mortem computed tomography angiography, using multi-phase post-mortem CTA, as well as medico-legal autopsies were performed. Localization accuracy of the bleeding was assessed by comparing the diagnostic findings of the different techniques. The results revealed that data from ante-mortem and post-mortem radiological examinations were similar, though the PMCTA showed a higher sensitivity for detecting the hemorrhage source than did ante-mortem radiological investigations. By comparing the results of PMCTA and conventional autopsy, much higher sensitivity was noted in PMCTA in identifying the source of the bleeding. In fact, the vessels involved were identified in eight out of nine cases using PMCTA and only in three cases through conventional autopsy. Our study showed that PMCTA, similar to clinical radiological investigations, is able to precisely identify lesions of arterial and/or venous vessels and thus determine the source of bleeding in cases of acute hemorrhages with fatal outcomes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The World Wide Web, the world¿s largest resource for information, has evolved from organizing information using controlled, top-down taxonomies to a bottom up approach that emphasizes assigning meaning to data via mechanisms such as the Social Web (Web 2.0). Tagging adds meta-data, (weak semantics) to the content available on the web. This research investigates the potential for repurposing this layer of meta-data. We propose a multi-phase approach that exploits user-defined tags to identify and extract domain-level concepts. We operationalize this approach and assess its feasibility by application to a publicly available tag repository. The paper describes insights gained from implementing and applying the heuristics contained in the approach, as well as challenges and implications of repurposing tags for extraction of domain-level concepts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In bubbly flow simulations, bubble size distribution is an important factor in determination of hydrodynamics. Beside hydrodynamics, it is crucial in the prediction of interfacial area available for mass transfer and in the prediction of reaction rate in gas-liquid reactors such as bubble columns. Solution of population balance equations is a method which can help to model the size distribution by considering continuous bubble coalescence and breakage. Therefore, in Computational Fluid Dynamic simulations it is necessary to couple CFD and Population Balance Model (CFD-PBM) to get reliable distribution. In the current work a CFD-PBM coupled model is implemented as FORTRAN subroutines in ANSYS CFX 10 and it has been tested for bubbly flow. This model uses the idea of Multi Phase Multi Size Group approach which was previously presented by Sha et al. (2006) [18]. The current CFD-PBM coupled method considers inhomogeneous flow field for different bubble size groups in the Eulerian multi-dispersed phase systems. Considering different velocity field for bubbles can give the advantageof more accurate solution of hydrodynamics. It is also an improved method for prediction of bubble size distribution in multiphase flow compared to available commercial packages.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectifs pédagogiques :Savoir comment s'effectue un angio-scanner post-mortem multi-phases.Connaître les compétences du manipulateur forensique.Identifier les nouvelles technologies développées pour cette nouvelle méthode.Connaître les avantages et les limitations de cette technique.Apprendre les difficultés d'interprétation radiologiques des images obtenues.Messages à retenir :L'angio-scanner post-mortem permet de visualiser des pathologies qui ne sont pas visibles lors de l'autopsie , telles que la source exacte d'une hémorragie.L'angio-scanner post-mortem est indiqué pour les cas de mort subite d'origine cardiaque, des décès d'origine traumatique et des décès suites aux interventions médicales.Une nouvelle machine à injection dédiée à cette technique a été développée, qui permet aussi de sauvegarder toutes les données de la perfusion, telles que les différentes courbes de pression et les informations des corps examinés.Grâce à la formation spécifique de manipulateurs forensiques, qui sont capables d'effectuer l'examen de manière autonome, la technique peut être utilisée de façon routinière en médecine légale. L'interprétation radiologique nécessite la connaissance des artéfacts post-mortem pour éviter des interprétations erronées.Résumé :L'angio-scanner combiné à l'autopsie conventionnelle permet d'augmenter la qualité de l'examen post-mortem. L'examen est dirigé par le manipulateurforensique qui gère la machine à perfusion, la préparation du corps et la technique multi-phase. En cours de cette année, une machine à perfusion spécialisée a été développée. L'avantage de cette technique est notamment sa sensibilité supérieure à celle de l'autopsie pour la détection des lésions vasculaires . Les limitations s'expliquent par des artéfacts qui rendent difficile voire impossible l'interprétation de certaines pathologies telles que l'occlusion d'un vaisseau par un thrombus qui est imité par un caillot de sang post-mortem.