Resumo:
Describir mediciones 3D y hallazgos estructurales de válvula mitral, en pacientes sanos, y con insuficiencia mitral grado 3 o 4, con enfermedad coronaria, patologías degenerativas o cardiopatía dilatada no isquémica, mediante uso de ecocardiografia transesofágica 3D en tiempo real.
Resumo:
OBJETIVOS: Describir y comparar los cambios dinámicos de la geometría del anillo mitral durante todo el ciclo cardiaco en pacientes con insuficiencia mitral isquémica y pacientes con válvula mitral normal. MATERIALES Y MÉTODOS: Los estudios ecocardiográficos analizados fueron 37, 23 con insuficiencia mitral isquémica y 14 con válvula mitral normal. La reconstrucción del anillo se realizó en la estación de trabajo Xcelera (Philips Medial Systems) mediante la herramienta de análisis mitral (MVQ), en 5 momentos del ciclo cardiaco: Comienzo de Sístole, Mitad de Sístole, Final de Sístole, Mitad de Diástole y Final de Diástole. RESULTADOS: El anillo del grupo control, fue más dinámico, con sus menores dimensiones al final de la diástole, presentando incremento progresivo durante la sístole. Los cambios en el perímetro y el área, fueron significativos entre el comienzo y mitad de la sístole (p:0.087 y p: 0.055). En el grupo con insuficiencia mitral isquémica, el anillo fue más estático. Todas las dimensiones en este grupo, fueron mayores en los cinco momentos del ciclo cardiaco. (p < 0.1). El anillo también fue más plano, con un índice morfológico anular menor al del grupo control (p:0.087). DISCUSIÓN Y CONCLUSIONES: En pacientes sin insuficiencia mitral, el anillo es una estructura dinámica. Durante la sístole, las menores dimensiones se produjeron al comienzo de este periodo y la conformación en silla de montar se mantuvo, protegiendo contra la insuficiencia mitral. El anillo del grupo con insuficiencia mitral fue más estático y plano, perdiendo los mecanismos protectores.
Resumo:
Objective: To report the outcome of partial external mitral annuloplasty in dogs with congestive heart failure (CHF) due to mitral regurgitation caused by myxomatous mitral valve degeneration (MMVD). Animals, materials and methods: Nine client-owned dogs with CHF due to mitral regurgitation caused by MMVD. Surgery consisted of a double row of pledget-butressed continuous suture lines placed into the left ventricle parallel and just ventral to the atrioventricular groove between the subsinuosal branch of the left circumflex coronary artery and the paraconal branch of the left coronary artery. Results: Two dogs died during surgery because of severe hemorrhage. Two dogs died 12 and 36 h after surgery because of acute myocardial infarction. Three dogs were euthanized 2 and 4 weeks after surgery because of progression of CHF, 1 was euthanized 30 days after surgery for non-cardiac disease, and 1 survived for 48 months. In the 5 dogs that survived to discharge there was no significant change in the left atrium to aortic ratio with surgery (3.6 ± 0.56 before surgery; 3.1 ± 0.4 after surgery; p = 0.182), and no significant change in mitral regurgitant fraction in 4 dogs in which this measurement was made (78.7 ± 2.0% before surgery; 68.7 ± 7.5% after surgery; p = 0.09). Conclusions: Partial external mitral annuloplasty in dogs with CHF due to MMVD was associated with high perioperative mortality and most dogs that survived to discharge failed to show clinically relevant palliation from this procedure. Consequently, partial external mitral annuloplasty is not a viable option for dogs with mitral regurgitation due to MMVD that has progressed to the stage of CHF. © 2011 Elsevier B.V. All rights reserved.
Resumo:
FUNDAMENTO: pacientes com valvopatia mitral podem evoluir com congestão pulmonar, que aumenta o trabalho dos músculos respiratórios; essa sobrecarga pode alterar o padrão respiratório com predomínio do deslocamento torácico ou presença de movimentos paradoxais. OBJETIVO: a) estudar o padrão respiratório e movimento toracoabdominal (MTA) em pacientes com doença mitral b) estudar o efeito do posicionamento nos parâmetros respiratórios c) correlacionar hipertensão pulmonar com presença de incoordenação do MTA. MÉTODOS: o padrão respiratório e o MTA de pacientes com doença mitral foram avaliados por pletismografia respiratória por indutância, nas posições dorsal e sentada, durante dois minutos de respiração tranquila. Analisou-se volume corrente (Vc) e tempos respiratórios e as variáveis do MTA. RESULTADOS: de 65 pacientes incluídos, 10 foram retirados, 29 participaram do grupo estenose mitral e 26 do grupo insuficiência mitral. O Vc, a ventilação pulmonar e o fluxo inspiratório médio aumentaram significantemente na posição sentada, sem diferenças entre os grupos. O MTA manteve-se coordenado entre os grupos e as posições; no entanto, cinco pacientes na posição dorsal apresentaram incoordenação (três no grupo estenose mitral; dois no grupo insuficiência mitral) com correlação significante com valores de pressão de artéria pulmonar (r = 0,992, p = 0,007). CONCLUSÃO: o padrão respiratório e o MTA não apresentam diferenças entre pacientes com estenose ou insuficiência mitral. A posição sentada aumenta o Vc sem alterar os tempos respiratórios. A presença de incoordenação toracoabdominal na posição dorsal esteve associação à hipertensão pulmonar.
Resumo:
An unusual case of localized amyloid light-chain (AL) amyloidosis and extramedullary plasmacytoma of the mitral valve is described. The worsening of a mitral regurgitation led to investigations and surgery. The valve presented marked distortion and thickening by type AL amyloid associated with a monotypic CD138+ immunoglobulin lambda plasma cell proliferation. Systemic staging showed a normal bone marrow and no evidence of amyloid deposition in other localizations. The patient's outcome after mitral valve replacement was excellent. To our knowledge, this is the first description of a localized AL amyloidosis as well as of a primary extramedullary plasmacytoma of the mitral valve.
Resumo:
Transcatheter aortic valve implantation (TAVI) has demonstrated the feasibility of treating valvular heart disease with transcatheter therapy. On the back of this success, various transcatheter concepts are being evaluated to treat other valvular disease, especially mitral regurgitation (MR). The concepts currently approved to treat MR replicate surgical mitral valve repair. However, most of them cannot eliminate MR completely. Similar to TAVI, a transcatheter mitral valve implantation may provide a valuable alternative. The FORTIS transcatheter mitral valve (Edwards Lifesciences, Irvine, CA, USA) is a self-expanding device implanted via a transapical approach. We describe our experience and early results in the first five patients treated on compassionate grounds. We also describe the details of the device, selection criteria and technical details of implantation.
Resumo:
BACKGROUND The use of transcatheter mitral valve repair (TMVR) has gained widespread acceptance in Europe, but data on immediate success, safety, and long-term echocardiographic follow-up in real-world patients are still limited. OBJECTIVES The aim of this multinational registry is to present a real-world overview of TMVR use in Europe. METHODS The Transcatheter Valve Treatment Sentinel Pilot Registry is a prospective, independent, consecutive collection of individual patient data. RESULTS A total of 628 patients (mean age 74.2 ± 9.7 years, 63.1% men) underwent TMVR between January 2011 and December 2012 in 25 centers in 8 European countries. The prevalent pathogenesis was functional mitral regurgitation (FMR) (n = 452 [72.0%]). The majority of patients (85.5%) were highly symptomatic (New York Heart Association functional class III or higher), with a high logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) (20.4 ± 16.7%). Acute procedural success was high (95.4%) and similar in FMR and degenerative mitral regurgitation (p = 0.662). One clip was implanted in 61.4% of patients. In-hospital mortality was low (2.9%), without significant differences between groups. The estimated 1-year mortality was 15.3%, which was similar for FMR and degenerative mitral regurgitation. The estimated 1-year rate of rehospitalization because of heart failure was 22.8%, significantly higher in the FMR group (25.8% vs. 12.0%, p[log-rank] = 0.009). Paired echocardiographic data from the 1-year follow-up, available for 368 consecutive patients in 15 centers, showed a persistent reduction in the degree of mitral regurgitation at 1 year (6.0% of patients with severe mitral regurgitation). CONCLUSIONS This independent, contemporary registry shows that TMVR is associated with high immediate success, low complication rates, and sustained 1-year reduction of the severity of mitral regurgitation and improvement of clinical symptoms.
Resumo:
Objective: Minimizing resection and preserving leaflet tissue has been previously shown to be beneficial for mitral valve function and leaflet kinematics after repair of acute posterior leaflet prolapse in porcine valves. We examined the effects of different additional methods of mitral valve repair (neochordoplasty, ring annuloplasty, edge-to-edge repair and triangular resection) on hemodynamics at different heart rates in an experimental model. Methods: Severe acute P2 prolapse was created in eight porcine mitral valves by resecting the posterior marginal chordae. Valve hemodynamics was quantified under pulsatile conditions in an in vitro heart simulator before and after surgical manipulation. Mitral regurgitation was corrected using four different methods of repair on the same valve: neochordoplasty with expanded polytetrafluoroethylene sutures alone and together with ring annuloplasty, edge-to-edge repair and triangular resection, both with non-restrictive annuloplasty. Residual mitral valve leak, trans-valvular pressure gradients, flow and cardiac output were measured at 60 and 80 beats/min. A validated statistical linear mixed model was used to analyze the effect of treatment. The p values were calculated using a two-sided Wald test. Results: Only neochordoplasty with expanded polytetrafluoroethylene sutures but without ring annuloplasty achieved similar hemodynamics compared to those of the native mitral valve (p range 0.071-0.901). Trans-valvular diastolic pressure gradients were within a physiologic range but significantly higher than those of the native valve following neochordoplasty with ring annuloplasty (p=0.000), triangular resection (p=0.000) and edge-to-edge repair (p=0.000). Neochordoplasty alone was significantly better in terms of hemodynamic than neochordoplasty with a ring annuloplasty (p=0.000). These values were stable regardless of heart rate or ring size. Conclusions: Neochordoplasty without ring annuloplasty is the only repair technique able to achieve almost native physiological hemodynamics after correction of leaflet prolapse in a porcine experimental model of acute chordal rupture.
Resumo:
AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.
Resumo:
Introduction. Advantages of the bicaval versus the biatrial technique have been reported, emphasizing atrial electrical stability and less tricuspid regurgitation. Objective. To analyze the impact of the surgical technique on long-term pulmonary pressures, contractility, and graft valvular behavior after heart transplantation. Methods. Among 400 orthotopic heart transplantation recipients from 1985 to 2010, we selected 30 consecutive patients who had survived beyond 3 years. The biatrial versus bicaval surgical technique groups included 15 patients each. Their preoperative clinical characteristics were similar. None of the patients displayed a pulmonary vascular resistance or pulmonary artery pressure over 6U Wood or 60 mm Hg, respectively. We evaluated invasive hemodynamic parameters during routine endomyocardial biopsies. Two-dimensional echocardiographic parameters were obtained from routine examinations. Results. There were no significant differences regarding right atrial pressure, systolic pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, cardiac index, systolic blood pressure, left ventricular ejection fraction, and mitral regurgitation (P > .05). Tricuspid regurgitation increased significantly over the 3 years of observation only among the biatrial group (P = .0212). In both groups, the right atrial pressure, pulmonary wedge capillary pressure, transpulmonary gradient, and pulmonary vascular resistance decreased significantly (P < .05) from the pre- to the postoperative examination. In both groups cardiac index and systemic blood pressure increased significantly after transplantation (P < .05). Comparative analysis of the groups only showed significant differences regarding right atrial pressure and degree of tricuspid regurgitation; the bicaval group showing the best performance. Conclusions. Both surgical techniques ensure adequate left ventricular function in the long term; however, the bicaval technique provided better trends in hemodynamic performance, as well as a lower incidence and severity of tricuspid valve dysfunction.
Resumo:
Background: There is only limited knowledge on how the quantification of valvular regurgitation by color Doppler is affected by changing blood viscosity. This study was designed to evaluate the effect of changing blood viscosity on the vena contracta width using an in vitro model of valvular insufficiency capable of providing ample variation in the rate and stroke volume. Methods: We constructed a pulsatile flow model filled with human blood at varying hematocrit (15%, 35%, and 55%) and corresponding blood viscosity (blood/water viscosity: 2.6, 4.8, 9.1) levels in which jets were driven through a known orifice (7 mm(2)) into a 110 mL compliant receiving chamber (compliance: 2.2 mL/mmHg) by a pulsatile pump. In addition, we used variable pump stroke volumes (5, 7.5, and 10 mL) and rates (40, 60, and 80 ppm). Vena contracta region was imaged using a 3.5 MHz transducer. Pressure and volume in the flow model were kept constant during each experimental condition, as well as ultrasound settings. Results: Blood viscosity variation in the experimental range did not induce significant changes in vena contracta dimensions. Also, vena contracta width did not change from normal to low hematocrit and viscosity levels. A very modest increase only in vena contracta dimension was observed at very high level of blood viscosity when hematocrit was set to 55% . Pump rate, in the evaluated range, did not influence vena contracta width. These results in controlled experimental settings suggest that the vena contracta is an accurate quantitative method for quantifying valvular regurgitation even when this condition is associated with anemia, a frequent finding in patients with valvular heart disease.
Resumo:
Background. Although digital and videotaped images are known to be comparable for the evaluation of left ventricular function, their relative accuracy for assessment of more complex anatomy is unclear. We sought to compare reading time, storage costs, and concordance of video and digital interpretations across multiple observers and sites. Methods. One hundred one patients with valvular (90 mitral, 48 aortic, 80 tricuspid) disease were selected prospectively, and studies were stored according to video and standardized digital protocols. The same reviewer interpreted video and digital images independently and at different times with the use of a standard report form to evaluate 40 items (eg, severity of stenosis or regurgitation, leaflet thickening, and calcification) as normal or mildly, moderately, or severely abnormal Concordance between modalities was expressed at kappa Major discordance (difference of >1 level of severity) was ascribed to the modality that gave the lesser severity. CD-ROM was used to store digital data (20:1 lossy compression), and super-VHS video-tape was used to store video data The reading time and storage costs for each modality were compared Results. Measured parameters were highly concordant (ejection fraction was 52% +/- 13% by both). Major discordance was rare, and lesser values were reported with digital rather than video interpretation in the categories of aortic and mitral valve thicken ing (1% to 2%) and severity of mitral regurgitation (2%). Digital reading time was 6.8 +/- 2.4 minutes, 38% shorter than with video (11.0 +/- 3.0, range 8 to 22 minutes, P < .001). Compressed digital studies had an average size of 60 <plus/minus> 14 megabytes (range 26 to 96 megabytes). Storage cost for video was A$0.62 per patient (18 studies per tape, total cost A$11.20), compared with A$0.31 per patient for digital storage (8 studies per CD-ROM, total cost A$2.50). Conclusion. Digital and video interpretation were highly concordant; in the few cases of major discordance, the digital scores were lower, perhaps reflecting undersampling. Use of additional views and longer clips may be indicated to minimize discordance with video in patients with complex problems. Digital interpretation offers a significant reduction in reading times and the cost of archiving.
Resumo:
A 75-year old female patient, with previous inferior acute myocardial infarction (AMI) in December 2000, was admitted in April 2001 with angina and heart failure. Transthoracic echocardiography (TTE) was suggestive of a postero-inferior pseudoaneurysm (PA) of the left ventricle (LV), with 61x49 mm. of size and mitral regurgitation. Cardiac catheterization was suspected of a PA of the LV and revealed a three vessels coronary artery disease. On 20th April she was submitted to cardiac surgery with resection of a large LV aneurysm (AN) and triple coronary artery bypass surgery. Afterwards, she was on NYHA class III and subsequent TTE and transesophagic echocardiography (TEE) were suggestive of a 90x60 mm LV posterior PA (confirmed by nuclear magnetic resonance) and severe mitral regurgitation, with good LV systolic function. She underwent a new cardiac surgery on 31st May 2002, with resuturing of the LV postero-inferior wall patch and removal of the PA. The patient is in good condition and on NYHA functional class I-II.