988 resultados para Microtomografia de raios-X
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Química - IQ
Resumo:
In chemical industry, petrochemical and oil refinery may be found situations that working pressures and very high temperatures, and alloys that comprise such equipment must have specific characteristics such. As a way to ensure that the materials are as designed, companies have some specific techniques, and one of them is X-ray fluorescence spectrometry, which allows its application in devices small and lightweight, which ensures its portability in field use. This technique however, has some shortcomings such as the impossibility of detecting carbon and other elements of low atomic number which can generate false identifications of elements that are not in the league or non-detection of existing elements. Therefore, this study investigated the reliability of this method using the apparatus Niton XL3t 800 and may conclude that their results are reliable and can be used to assist in ensuring the operational integrity of the production units of these companies
Resumo:
Snakes from Bothrops genus are responsible for more than 90% of the ophidian accidents in Brazil. One of the main complications from this kind of accident is muscular necrosis, which is related to the action of phospholipases A2 and metalloproteases, two groups of enzymes found in the venom of these animals. Although this complication cannot be solved by serum therapy administration, a great number of studies have been performed with the attempt to know the pharmacological sites of these toxins aiming, in the future, the development of complementary treatments to serum therapy. This work proposes structural studies of bothropic phospholipases A2 (PLA2s) in the presence of ions relevant to their activity, using the X-ray crystallography technique. Recently, it was demonstrated ions, as manganese, calcium and others, interfere in the biological activity of the PLA2s. Particularly, Lys49-PLA2s in the presence of manganese ions have miotoxicity reduced. Asp49-PLA2s show catalytic activity dependent of calcium, although structural studies with a miotoxic Asp49-PLA2, BthTX-II, suggest a possible catalytic mechanism independent of calcium. Therefore, co-crystallization of BthTX-II in the presence of calcium ions and of PrTX-I in the presence of manganese ions were performed. Comparative structural studies among obtained results and others already published in the literature were performed aiming a better understanding of the structure-function relationship of these toxins. The BthTX-II with the presence of calcium do not show this ion in the loop of coordination of calcium, presence necessary to develop the catalyses. After comparison of this model with the native one, only one distortion was found, but no apparent relationship with the residues responsible for its activity. In the PrTX-I structure, regions candidates of manganese ions were also found... (Complete abstract click electronic access below)
Resumo:
Apoptosis is a form of programmed cell death selectively removes abnormal cells, and thus contributes to maintaining the balance of the dynamics of cell reproduction. Therefore the verification of the occurrence of apoptotic cell death after a pathological stimulus is crucial for the analysis of the maintenance of normal cell cycle of a given tissue or organ. In this experiment were used cells lines human mammary tumor MDAMB231, T47, MCF7, which were irradiated with X-rays at a dose of 5 Gy in a time interval of 15 seconds, and filtration of 1mm aluminum. Samples containing the cells were grown in a specific culture medium, containing fetal bovine serum and growth factor, and two samples were prepared with each of the cell lines, one to be irradiated, and another that has not been irradiated, which denoted by negative control of the irradiation. The primary goal of the experiment was to verify and compare the rates of apoptosis in each cell lines, in which were irradiated and that were not irradiated, using flow cytometry as a method for detecting apoptotic cell death in together with specific markers annexin V and propidium iodide. Data from the readings made by flow cytometry were analyzed and interpreted using the software WinMDI statistical graph. By comparing the indices relating to the readings of positive and negative for specific markers of apoptosis, based on differences in the statistical data presented lectures regarding the cellular irradiated and not irradiated, collude cells in question once... (Complete abstract click electronic access below)
Resumo:
The small angle X-ray scattering (SAXS) technique has been used with very much versatility and success in the structural characterization of nanostructured materials. The present work deals with a study of the principles of the SAXS technique and of some classical models employed in the structural characterization of nanostructured materials. Particularly, the study of the models and of the associated methodologies is applied to a set of samples of silica gels, of varied typical structures, prepared in the Laboratório de Novos Materiais of the Departamento de Física of the IGCE. The work discusses in an introductory chapter the principles of the SAXS technique and the foundation of classical models often used in the structural characterization of materials. The classical models and the associated methodologies were applied to a variety of silica gel structures. The studies include: i) the scattering from a system of particles - Guinier's law; ii) the asymptotic scattering from a two-phase system - Porod's law; iii) systematic deviation from Porod's law - Surface Fractal; iv) heterogeneities in solids with random size distribution - DAB Model; and v) the scattering from mass fractal structures. The analyses were carried out from experimental SAXS data obtained in several opportunities at the Laboratório Nacional de Luz Síncrotron (LNLS)
Resumo:
The huge demand for procedures involving ionizing radiation promotes the need for safe methods of experimentation considering the danger of their biological e ects with consequent risk to humans. Brazilian's legislation prohibits experiments involving this type of radiation in humans through Decree 453 of Ministry of Health with determines that such procedures comply with the principles of justi cation, optimization and dose limitation. In this line, concurrently with the advancement of available computer processing power, computing simulations have become relevant in those situations where experimental procedures are too cost or impractical. The Monte Carlo method, created along the Manhattan Project duringWorldWar II, is a powerful strategy to simulations in computational physics. In medical physics, this technique has been extensively used with applications in diagnostics and cancer treatment. The objective of this work is to simulate the production and detection of X-rays for the energy range of diagnostic radiology, for molybdenum target, using the Geant4 toolkit. X-ray tubes with this kind of target material are used in diagnostic radiology, speci cally in mammography, one of the most used techniques for screening of breast cancer in women. During the simulations, we used di erent models for bremsstrahlung available in physical models for low energy, in situations already covered by the literature in earlier versions of Geant4. Our results show that although the physical situations seems qualitatively adequate, quantitative comparisons to available analytical data shows aws in the code of Geant4 Low Energy source
Resumo:
The quality assurance control program (QACP) in clinical radiology is very important to acquire, image quality, patient dose reduction and cost for the institution. The verification of the real tension on the x ray tube, it is one of many parameters that may be determined on a QACP. This act on image quality as absorbed dose in patient. Once proved the importance of this fact, this study come up with the determination of tension to any X ray tube used on medical routine, on quick, safe and low cost manner. To reach the aim of this study, the methodology consisted on measuring expose rates (ER) using different thicknesses of copper (Cu) plates like filters and relating these results with Half Layer Value (HLV). Afterwards, the HLV was associated to real tension that was acquired with kilo voltage of peak (kVp) measurers used on clinical routine. So walking in this path, when performed the ER, on any X ray tube, it’s possible acquire the HLV and consequently the real kVp, considering measures obtained before, on the methodology of kVp estimative development
Resumo:
The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public
Resumo:
To determinate the multielemental concentrations in biological samples using the technique of total reflection X-ray fluorescence (TRFX) is essential the use of standard samples. The aim of this study is the determination of the sensitivities of the relevant elements in standard samples (Multi Element atomic spectroscopy standard solution in HNO3 I) prepared in three solutions with different and known concentrations. Based on the sensitivities of the elements contained in the multilelementar standard sample, it can estimate the sensitivity for an element found in the biological sample and consequently it is possible to determinate the concentration, even though the standard does not contain this element. The measurement of fluorescence was performed at the Brazilian Synchrotron Light Laboratory (LNLS) in Campinas
Resumo:
As normas nacionais e internacionais prevêem que a manutenção dos níveis de radiação deve estar abaixo do permitido. Sendo assim, a ICRP [1] (International Commission on Radiological Protection) exige métodos de otimização para garantir que o público esteja exposto aos menores níveis de radiação possíveis. Como método de otimização, aproximações teóricas e semi-empiricas podem realizar uma determinação do espectro de raios-X, sendo fundamental para o diagnóstico de energia, estimando a dose de radiações em pacientes e formulando modelos de blindagem. Métodos adequados de radioproteção foram desenvolvidos na física médica como a medicina nuclear, a radioterapia e a radiologia diagnóstica. Um dos métodos semi-empiricos utilizados é o modelo de TBC que é capaz de reproduzir e calcular os espectros gerados pelo anodo de tungstênio. Com o modelo de TBC modificado é possível também obedecer às exigências das barreiras protetoras presentes na radiologia, levando em conta a forma de onda arbitrária e a filtração adicional na geração do espectro não presente no modelo original. Além disso, realiza-se a calibração do espectro gerado para que o modelo de TBC represente a quantidade e comportamento de radiações típicas. Dessa forma, realiza-se uma revisão do modelo de TBC implementando-o ao programa matemático Matlab e comparando-o com os resultados adquiridos pelo Código MCNP-5 no Método de Monte Carlo. Os resultados encontrados são bastante satisfatórios, tanto em termos quantitativos quanto qualitativos dos feixes. Para a calibração, desenvolve-se uma análise dos espectros gerados pelo TBC Modificado aplicado ao programa Mathcad e Matlab sob as mesmas condições. Os espectros gerados apresentam o mesmo comportamento, diferindo em até 12% nos valores encontrados para camadas semi-redutoras, coeficiente de homogeneidade e energia efetiva
Resumo:
The progress in radiology is related with the development of new systems of image formation with the lesser dose in the pacient. The improve of the dose in the pacient, without compromising the quality of the image, is one of the responsibilities of a medical physicist in a sector of diagnosis for image. This research has as objective to evaluate the conditions of use of an equipment of x-rays, from tests of quality control. The results gotten in this work have been part of data of an Effective Program of Quality Control (PECQ) of the sector of diagnosis for image of the Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP (HCFMB-UNESP)
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
By the early 20th century, the blood vessels could only be seen by anatomical studies. Shortly after the discovery of X-rays by Conrad Roentgen in 1895, the first experiments with radiographic imaging were performed with blood vessels. In 1905, the first experiment involving catheterization of arterial and venous system in dogs was performed and only in 1914 performed on living human patients. Parallel to these landmarks, there were advances in diagnostic imaging devices and the evolution of contrast substances was of utmost importance to the current angiography occupy a prominent role not only in terms of diagnosis, but also in the treatment of various disorders. The main objective of this review is to weave historical considerations and comparisons between the different methodologies used in angiography, because its importance; that may be in future, a veterinary diagnostic decisive test