970 resultados para Methodological analysis
Resumo:
Includes bibliography
Resumo:
This paper reports on a process to validate a revised version of a system for coding classroom discourse in foreign language lessons, a context in which the dual role of language (as content and means of communication) and the speakers' specific pedagogical aims lead to a certain degree of ambiguity in language analysis. The language used by teachers and students has been extensively studied, and a framework of concepts concerning classroom discourse well-established. Models for coding classroom language need, however, to be revised when they are applied to specific research contexts. The application and revision of an initial framework can lead to the development of earlier models, and to the re-definition of previously established categories of analysis that have to be validated. The procedures followed to validate a coding system are related here as guidelines for conducting research under similar circumstances. The advantages of using instruments that incorporate two types of data, that is, quantitative measures and qualitative information from raters' metadiscourse, are discussed, and it is suggested that such procedure can contribute to the process of validation itself, towards attaining reliability of research results, as well as indicate some constraints of the adopted research methodology.
Resumo:
Studies involving amplified fragment length polymorphism (cDNA-AFLP) have often used polyacrylamide gels with radiolabeled primers in order to establish best primer combinations, to analyze, and to recover transcript-derived fragments. Use of automatic sequencer to establish best primer combinations is convenient, because it saves time, reduces costs and risks of contamination with radioactive material and acrylamide, and allows objective band-matching and more precise evaluation of transcript-derived fragments intensities. This study aimed at examining the gene expression of commercial cultivars of P. guajava subjected to water and mechanical injury stresses, combining analyses by automatic sequencer and fluorescent kits for polyacrylamide gel electrophoresis. Firstly, 64 combinations of EcoRI and MseI primers were tested. Ten combinations with higher number of polymorphic fragments were then selected for transcript-derived fragments recovering and cluster analysis, involving 45 saplings of P. guajava. Two groups were obtained, one composed by the control samplings, and another formed by samplings undergoing stress, with no clear distinction between stress treatments. The results revealed the convenience of using a combination of automatic sequencer and fluorescent kits for polyacrylamide gel electrophoreses to examine gene expression profiles. The Unweighted Pair Group Method with Arithmetic Mean analysis using Euclidean distances points out a similar induced response mechanism of P. guajava undergoing water stress and mechanical injury.
Resumo:
3D video-fluoroscopy is an accurate but cumbersome technique to estimate natural or prosthetic human joint kinematics. This dissertation proposes innovative methodologies to improve the 3D fluoroscopic analysis reliability and usability. Being based on direct radiographic imaging of the joint, and avoiding soft tissue artefact that limits the accuracy of skin marker based techniques, the fluoroscopic analysis has a potential accuracy of the order of mm/deg or better. It can provide fundamental informations for clinical and methodological applications, but, notwithstanding the number of methodological protocols proposed in the literature, time consuming user interaction is exploited to obtain consistent results. The user-dependency prevented a reliable quantification of the actual accuracy and precision of the methods, and, consequently, slowed down the translation to the clinical practice. The objective of the present work was to speed up this process introducing methodological improvements in the analysis. In the thesis, the fluoroscopic analysis was characterized in depth, in order to evaluate its pros and cons, and to provide reliable solutions to overcome its limitations. To this aim, an analytical approach was followed. The major sources of error were isolated with in-silico preliminary studies as: (a) geometric distortion and calibration errors, (b) 2D images and 3D models resolutions, (c) incorrect contour extraction, (d) bone model symmetries, (e) optimization algorithm limitations, (f) user errors. The effect of each criticality was quantified, and verified with an in-vivo preliminary study on the elbow joint. The dominant source of error was identified in the limited extent of the convergence domain for the local optimization algorithms, which forced the user to manually specify the starting pose for the estimating process. To solve this problem, two different approaches were followed: to increase the optimal pose convergence basin, the local approach used sequential alignments of the 6 degrees of freedom in order of sensitivity, or a geometrical feature-based estimation of the initial conditions for the optimization; the global approach used an unsupervised memetic algorithm to optimally explore the search domain. The performances of the technique were evaluated with a series of in-silico studies and validated in-vitro with a phantom based comparison with a radiostereometric gold-standard. The accuracy of the method is joint-dependent, and for the intact knee joint, the new unsupervised algorithm guaranteed a maximum error lower than 0.5 mm for in-plane translations, 10 mm for out-of-plane translation, and of 3 deg for rotations in a mono-planar setup; and lower than 0.5 mm for translations and 1 deg for rotations in a bi-planar setups. The bi-planar setup is best suited when accurate results are needed, such as for methodological research studies. The mono-planar analysis may be enough for clinical application when the analysis time and cost may be an issue. A further reduction of the user interaction was obtained for prosthetic joints kinematics. A mixed region-growing and level-set segmentation method was proposed and halved the analysis time, delegating the computational burden to the machine. In-silico and in-vivo studies demonstrated that the reliability of the new semiautomatic method was comparable to a user defined manual gold-standard. The improved fluoroscopic analysis was finally applied to a first in-vivo methodological study on the foot kinematics. Preliminary evaluations showed that the presented methodology represents a feasible gold-standard for the validation of skin marker based foot kinematics protocols.
Resumo:
Dendrogeomorphology uses information sources recorded in the roots, trunks and branches of trees and bushes located in the fluvial system to complement (or sometimes even replace) systematic and palaeohydrological records of past floods. The application of dendrogeomorphic data sources and methods to palaeoflood analysis over nearly 40 years has allowed improvements to be made in frequency and magnitude estimations of past floods. Nevertheless, research carried out so far has shown that the dendrogeomorphic indicators traditionally used (mainly scar evidence), and their use to infer frequency and magnitude, have been restricted to a small, limited set of applications. New possibilities with enormous potential remain unexplored. New insights in future research of palaeoflood frequency and magnitude using dendrogeomorphic data sources should: (1) test the application of isotopic indicators (16O/18O ratio) to discover the meteorological origin of past floods; (2) use different dendrogeomorphic indicators to estimate peak flows with 2D (and 3D) hydraulic models and study how they relate to other palaeostage indicators; (3) investigate improved calibration of 2D hydraulic model parameters (roughness); and (4) apply statistics-based cost–benefit analysis to select optimal mitigation measures. This paper presents an overview of these innovative methodologies, with a focus on their capabilities and limitations in the reconstruction of recent floods and palaeofloods.