907 resultados para Metallic frameworks


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microwave assisted synthesis of the Cu(I) compound [Cu(µ4-4-ptz)]n [1, 4-ptz = 5-(4-pyridyl)tetrazolate] has been performed by employing a relatively easy method and within a shorter period of time compared to its sister compounds. The syntheses of the Cu(II) compounds [Cu3(µ3-4-ptz)4(µ2-N3)2(DMF)2]n∙(DMF)2n (2) and [Cu(µ2-4-ptz)2(H2O)2]n (3) using a similar method were reported previously by us. MOFs 1-3 revealed high catalytic activity toward oxidation of cyclic alkanes (cyclopentane, -hexane and -octane) with aqueous hydrogen peroxide, under very mild conditions (at room temperature), without any added solvent or additive. The most efficient system (2/H2O2) showed, for the oxidation of cyclohexane, a turnover number (TON) of 396 (TOF of 40 h−1), with an overall product yield (cyclohexanol and cyclohexanone) of 40% relative to the substrate. Moreover, the heterogeneous catalytic systems 1–3 allowed an easy catalyst recovery and reuse, at least for four consecutive cycles, maintaining ca. 90% of the initial high activity and concomitant high selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comunicação apresentada no 38º Congresso Mundial do Instituto Internacional de Sociologia, em Budapeste, Hungria, de 26 a 30 de Junho de 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho é o desenvolvimento de frameworks de testes automáticos de software. Este tipo de testes normalmente está associado ao modelo evolucionário e às metodologias ágeis de desenvolvimento de software, enquanto que os testes manuais estão relacionados com o modelo em cascata e as metodologias tradicionais. Como tal foi efetuado um estudo comparativo sobre os tipos de metodologias e de testes existentes, para decidir quais os que melhor se adequavam ao projeto e dar resposta à questão "Será que realmente compensa realizar testes (automáticos)?". Finalizado o estudo foram desenvolvidas duas frameworks, a primeira para a implementação de testes funcionais e unitários sem dependências a ser utilizada pelos estagiários curriculares da LabOrders, e a segunda para a implementação de testes unitários com dependências externas de base de dados e serviços, a ser utilizada pelos funcionários da empresa. Nas últimas duas décadas as metodologias ágeis de desenvolvimento de software não pararam de evoluir, no entanto as ferramentas de automação não conseguiram acompanhar este progresso. Muitas áreas não são abrangidas pelos testes e por isso alguns têm de ser feitos manualmente. Posto isto foram criadas várias funcionalidades inovadoras para aumentar a cobertura dos testes e tornar as frameworks o mais intuitivas possível, nomeadamente: 1. Download automático de ficheiros através do Internet Explorer 9 (e versões mais recentes). 2. Análise do conteúdo de ficheiros .pdf (através dos testes). 3. Obtenção de elementos web e respetivos atributos através de código jQuery utilizando a API WebDriver com PHP bindings. 4. Exibição de mensagens de erro personalizadas quando não é possível encontrar um determinado elemento. As frameworks implementadas estão também preparadas para a criação de outros testes (de carga, integração, regressão) que possam vir a ser necessários no futuro. Foram testadas em contexto de trabalho pelos colaboradores e clientes da empresa onde foi realizado o projeto de mestrado e os resultados permitiram concluir que a adoção de uma metodologia de desenvolvimento de software com testes automáticos pode aumentar a produtividade, reduzir as falhas e potenciar o cumprimento de orçamentos e prazos dos projetos das organizações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Disserta ção apresentada para obten ção do Grau de Mestre em Engenharia Química e Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os sistemas de informação integrados contribuem para a gestão eficiente das empresas, seja na organização e funcionamento internos ou nas relações externas. O mercado deste software é dominado pelas empresas que criam e distribuem sistemas proprietários. Existe uma alternativa, software livre, que disponibiliza aplicações em código aberto e maioritariamente de licença gratuita, que pode ser adaptado às necessidades das empresas. O objetivo do presente trabalho é avaliar a viabilidade de plataformas livres, de natureza vertical – OFBiz – e horizontal – Spring – como opção na escolha de um sistema de informação nas Pequenas e Médias Empresas portuguesas. Das áreas de negócio principais das organizações, foi selecionada a área de Recursos Humanos para efeitos de adaptação na aplicação OFBiz, com incidência em dois casos de uso: uma opção essencial, mas que atualmente não está prevista – Processamento de vencimentos – e outra já existente e que é avaliada em termos de necessidades de adaptação – Recrutamento. Sendo o idioma um requisito indispensável à internacionalização da aplicação, foi também analisada a sua implementação. A metodologia de investigação utilizada foi o Design Science Research, tendo sido implementado um protótipo para efeitos de teste e avaliação do projeto, com a elaboração de dois modelos: configuração e desenvolvimento. Implementado o protótipo, verificou-se que a framework vertical apresenta-se como uma alternativa mais viável do que a horizontal, pelas funcionalidades já existentes e que facilitam a adequação às necessidades de informação das Pequenas e Médias Empresas. A sua base tecnológica e de estrutura permite que a aplicação possa ser adaptada por técnicos especialistas das próprias empresas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes a study based on a research and evaluation of platforms (JavaScript frameworks and libraries carried out under the discipline of Tese/Dissertação/Estágio in the Master Degree Computer Science - area of expertise in Arquitecturas Sistemas e Redes, in Instituto Superior de Engenharia do Porto (ISEP). The JavaScript language is increasingly present in the development of software and particularly software for the web environment. For this reason there is a need to investigate the issue, as the platforms that are emerging in the market have a very low level of maturity compared to existing, it is crucial to identify the main differences so that we can save time, labor and other costs in research and experimentation developers. This project aims to inform a range of platforms and existing JavaScript libraries on the market. For further investigation, a study of use cases used at this point in the market was held. To assist the work were used qualitative research methods through the existing content of research related to the area, and quantitative research methods. It was thus conducted a survey sent via email to fifty regular users of the language, platforms, and JavaScript libraries, linking the functional and non-functional characteristics of the platforms and existing use cases in the market, in order to realize what is the use of these tools in his professional life. This study allowed developers to access information that will be compared and evaluated in order to achieve a more precise evaluation of the various analyzed platforms. It was also made an evaluation of adaptation of the various platforms to the various use cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flexible and low cost energy harvester device based on the magnetoelectric (ME) effect has been designed using Fe64Co17Si7B12 as amorphous magnetostrictive ribbons and PVDF as the piezoelectric element. Sandwich-type laminated composite of 3 cm long has been fabricated by gluing these ribbons to the PVDF with the Devcon 5 minute epoxy. Good power output and power density of 6.4 μW and 1.5 mW/cm3, respectively, have been obtained through a multiplier circuit. All values have been measured at the magnetomechanical resonance of the laminate. The effect of the length of the ME laminate on the power output has been also studied, exhibiting a decay as the length of the ME laminate does. Nevertheless, good performance of such device has been obtained for a 0.5 cm long device, working already at 337 KHz, within the low radio frequency (LRF) range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Companies and researchers involved in developing miniaturized electronic devices face the basic problem of the needed batteries size, finite life of time and environmental pollution caused by their final deposition. The current trends to overcome this situation point towards Energy Harvesting technology. These harvesters (or scavengers) store the energy from sources present in the ambient (as wind, solar, electromagnetic, etc) and are costless for us. Piezoelectric devices are the ones that show a higher power density, and materials as ceramic PZT or polymeric PVDF have already demonstrated their ability to act as such energy harvester elements. Combinations between piezoelectric and electromagnetic mechanism have been also extensively investigated. Nevertheless, the power generated by these combinations is limited under the application of small magnetic fields, reducing the performance of the energy harvester [1]. In the last years the appearance of magnetoelectric (ME) devices, in which the piezoelectric deformation is driven by the magnetostrictive element, enables to extract the energy of very small electromagnetic signals through the generated magnetoelectric voltage at the piezoelectric element. However, very little work has been done testing PVDF polymer as piezoelectric constituent of the ME energy harvester device, and only to be proposed as a possibility of application [2]. Among the advantages of using piezopolymers for vibrational energy harvesting we can remember that they are ductile, resilient to shock, deformable and lightweight. In this work we demonstrate the feasibility of using magnetostrictive Fe-rich magnetic amorphous alloys/piezoelectric PVDF sandwich-type laminated ME devices as energy harvesters. A very simple experimental set-up will show how these laminates can extract energy, in amounts of μW, from an external AC field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia e Gestão de Sistemas de Informação

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the immediate results of percutaneous mechanical mitral commissurotomy. METHODS: Thirty patients underwent percutaneous mechanical mitral commissurotomy performed with a Cribier's metallic valvulotome from 8/11/99 to 2/4/00. Mean age was 30.7 years, and 73.3% were women. With regards to functional class, 63.3% were class III, and 36.7% were class IV. The echocardiographic score had a mean value of 7.5± 1.8. RESULTS: The mitral valve area increased from 0.97±0.15cm² to 2.16±0.50cm² (p>0.0001). The mean diastolic gradient decreased from 17.9±5.0mmHg to 3.2±1.4mmHg. The mean left atrial pressure decreased from 23.6±5.4mmHg to 8.6±3.1mmHg, (p>0.0001). Systolic pressure in the pulmonary artery decreased from 52.7±18.3mmHg to 32.2±7.4mmHg. Twenty-nine cases were successful. One patient developed severe mitral regurgitation. Interatrial septal defect was observed and one patient. One patient had cardiac tamponade due to left ventricular perforation. No deaths occurred. CONCLUSION: This method has proven to be safe and efficient in the treatment of rheumatic mitral stenosis. The potential advantage is that it can be used multiple times after sterilization, which decreases procedural costs significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Characterisation of nanoparticles (NP) based on size distribution, surface area, reactivity, and aggregation status of nanoparticles (NP) are of prime importance because they are usually closely related to toxicity. To date, most of the toxicity studies are quite time and money consuming. In the present study we report the oxidative properties of a panel of various NP (four Carbonaceous, nine Metal oxides, and one Metal as showed in Table 1) assessed with an acellular reactivity test measuring dithiothreitol (DTT) consumption (Sauvain et al. 2008). Such a test allows determining the ability of NP to catalyse the transfer of electrons from DTT to oxygen. DTT is used as a reductant species. NP were diluted and sonicated in Tween 80® to a final concentration of 50 g/mL. Printex 90 was diluted 5 times before doing the DTT assay because of its expected higher activity. Suspensions were characterised for NP size distribution by Nanoparticle Tracking Analysis (Nanosight©). Fresh solutions were incubated with DTT (100 μM). Aliquots were taken every 5 min and the remaining DTT was determined by reacting it with DTNB. The reaction rate was determined for NP suspensions and blank in parallel. The mean Brownian size distribution of NP agglomerates in suspension is presented in Table 1. D values correspond to 10th, and 50th percentiles of the particle diameters. All the NP agglomerated in Tween 80 with a D50 size corresponding to at least twice their primary size, except for Al2O3 (300 nm). The DTT test showed Printex 90 sample to be the most reactive one, followed by Diesel EPA and Nanotubes. Most of the metallic NP was nonresponding toward this test, except for NiO and Ag which reacted positively and ZnO which presented the most negative reactivity (see Figure 1). This last observation suggests that electron transfer between DTT and oxygen is hindered in presence of ZnO compared with the blank. Such "stabilization" could be attributable to ZnO dissolution and complexation between Zn2+ ions and DTT.