999 resultados para Mercury film electrodes


Relevância:

80.00% 80.00%

Publicador:

Resumo:

LixCoOy films with x < 1 and y > 2 have been prepared by radio-frequency (rf) sputtering from high temperature (HT) LiCoO2 targets. Their structures have been examined with high resolution electron microscopy. Conductivities have been studied between 77 and 400 K. The electrochemical behaviour of film electrodes have been investigated with Li/LiClO4-PC/LixCoOy cells. The annealed films consist of nanocrystalline domains with amorphous boundaries. Electrical conductivities appear to arise from variable-range hopping (VRH) of holes. The films form good electrodes with operating potentials between 2.7 and 3.8 V. The observations have been discussed on the basis of a tentative and heuristic molecular orbital based energy band diagram. (C) 2002 Published by Elsevier Science Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the present work, Li2-x MnO3-y (LMO) thin films have been deposited by radio frequency (RF) reactive magnetron sputtering using acid-treated Li2MnO3 powder target. Systematic investigations have been carried out to study the effect of RF power on the physicochemical properties of LMO thin films deposited on platinized silicon substrates. X-ray diffraction, electron microscopy, surface chemical analysis and electrochemical studies were carried out for the LMO films after post deposition annealing treatment at 500 A degrees C for 1 h in air ambience. Galvanostatic charge discharge studies carried out using the LMO thin film electrodes, delivered a highest discharge capacity of 139 mu Ah mu m(-1) cm(-2) in the potential window 2.0-3.5 V vs. Li/Li+ at 100 W RF power and lowest discharge capacity of 80 mu Ah mu m(-1) cm(-2) at 75 W RF power. Thereafter, the physicochemical properties of LMO films deposited using optimized RF power 100 W on stainless steel substrates has been studied in the thickness range of 70 to 300 nm as a case study. From the galvanostatic charge discharge experiments, a stable discharge capacity of 68 mu Ah mu m(-1) cm(-2) was achieved in the potential window 2.0-4.2 V vs. Li/Li+ tested up to 30 cycles. As the thickness increased, the specific discharge capacity started reducing with higher magnitude of capacity fading.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

随着我国工业的快速发展,环境污染日益严重,其中重金属已经成为最主要的污染物 之一。重金属具有分布广泛、半衰期长等特点,因而对人们的生产生活危害巨大。镉作为 一种常见的重金属污染物,它能够引发废用性萎缩、肾功能衰竭和感染等疾病,因此对环 境中存在的痕量镉的进行检测显得极为重要。传统的痕量分析方法包括光谱分析法和色谱 分析法,但这两方法所使用的仪器比较笨重,操作过程复杂,因而不适于在线分析。电化 学分析方法因其快速、便携、价格低廉、灵敏度高等特点而受到了人们的广泛关注,其中 较为常用的阳极溶出伏安法已经在镉离子等重金属离子的现场快速高灵敏检测中发挥了 重要作用。然而传统阳极溶出法中使用的汞电极因具有毒性而被许多国家禁止使用,所以 寻找汞电极的替代电极成为近年来的阳极溶出技术的研究热点。铋膜电极因具有类似汞电 极的分析性能且环境友好而受到了广泛重视,特别是各种化学修饰方法使得铋膜电极的性 能得到了显著提高。但是目前铋膜电极仍存在稳定性低、抗干扰能力差等问题,这些不足 严重制约了该类电极在重金属的阳极溶出分析中的应用。本文旨在通过新的化学修饰方法 解决铋膜电极应用中的瓶颈问题,发展具有优异分析性能的化学修饰铋膜电极应用于镉离 子等重金属离子的阳极溶出分析。本文的主要研究内容包括: l)以阳极溶出法测定镉离子为例,研究了化学修饰铋膜电极的响应特性,考察了富 集时间、富集电位、铋离子浓度、离子载体浓度和Nafion 浓度等实验条件对检测灵敏度的 影响。 2)将离子载体引入铋膜电极与Nafion 结合使用,研究了镉离子在该电极上的阳极溶 出响应,并探讨了铜、铅、铟三种金属离子对镉离子检测选择性的影响。将这种改良后的 化学修饰铋膜电极用于实际海水样品的检测,所得结果与ICP-MS 的测量结果基本一致。 3)将四氟硼酸钠引入铋膜电极与离子载体、碳纳米管结合使用,研究了镉离子在该 电极上的阳极溶出响应,考察了铜、铅、铟离子对镉离子测定的影响。 4)考察了电解富集和开路电位富集两种富集方式对电极灵敏度和选择性的影响。 实验表明:通过预富集,在未除氧的溶液中即可得到显著的镉离子溶出电流峰,且背 景噪音低;加入离子载体后,电极对目标金属有良好的选择性,可以在复杂基体条件下测 定重金属离子镉;电解富集条件下电极的的灵敏度较高,而开路电位富集条件下电极的选 择性较好。这种环保的无汞化学修饰电极为海水中重金属污染物的检测提供了新的手段。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two kinds of quantum computation systems using artificial molecules: quantum computer and quantum analog computer are described. The artificial molecule consists of two or three coupled quantum dots stacked along z direction and one single electron, In quantum computer, one-qubit and two-qubit gates are constructed by one molecule and two molecules, respectively. The coupling between two qubits in a quantum gate can be controlled by thin film electrodes. We also constructed a quantum analog computer by designing a three-dot molecule network and mapping a graph 3-colorability problem onto the network. The ground-state configuration of the single electrons in the network corresponds to one of the problem solutions, We numerically study the operations of the two kinds of the quantum computers and demonstrate that they quantum gates can perform the quantum computation and solve complex problems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Heterogeneous electrocatalytic reduction of hydrogen peroxide (H2O2) by C-60 is reported for the first time. C-60 is embedded in tetra octyl ammonium bromide (TOAB) film and is characterized by scanning electron microscopy and cyclic voltammetry. Electrocatalytic studies show that the trianion of C-60 mediates the electrocatalytic reduction of H2O2 in aqueous solution containing 0.1 M KCl. Application of such film modified electrode as an amperometric sensor for H2O2 determination is also examined.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work herein reports the approach for the simultaneous determination of heavy metal ions including cadmium (Cd(II)), lead (Pb(II)), and chromium (Cr(VI)) using a bismuth film electrode (BFE) by anodic stripping voltammertry (ASV). The BFE used was plated in situ. Due to the reduction of Cr(VI) with H2O2 in the acid medium, on one hand, the Cr(III) was produced and Cr(VI) was indirectly detected by monitoring the content of Cr(III) using square-wave ASV. On the other hand, Pb(II) was also released from the complex between Pb(II) and Cr(VI). Furthermore, the coexistence of the Cd(II) was also simultaneously detected with Pb(II) and Cr(VI) in this system as a result of the formation of an alloy with Bi. The detection limits of this method were 1.39 ppb for Cd(II), 2.47 ppb for Pb(II) and 5.27 ppb for Cr(VI) with a preconcentration time of 120 s under optimal conditions (S/N = 3), respectively. Furthermore, the sensitivity of this method can be improved by controlling the deposition time or by using a cation-exchange polymer (such as Nafion) modified electrode.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Based on the electrostatic attraction Keggin-type polyoxometalate H4SiW12O40 (SiW12) and small molecule 4-aminobenzo-15-crown-5 ether (4-AB15C5) were alternately deposited on poly (allylamine hydrochloride) (PAH)-derived indium tin oxide (ITO) substrate through a layer-by-layer (LBL) self-assembly, forming a supramolecular multilayer film (film-A). SiW12 was also deposited on a glassy carbon electrode (GCE) derived by 4-AB15C5 via covalent bonding in 0.1 M NaCl aqueous solution and formed a composite monolayer film (film-B). UV-vis absorption spectroscopy, X-ray photoelectron spectroscopy (XPS) and Fourier-transform infrared (FTIR) spectroscopy measurements demonstrated that the interactions between SiW12 and 4-AB15C5 in both two film electrodes were the same and caused by the bridging action of oxonium ions. But, the nanostructure in the two film electrodes was different. 4-AB15C5 in film-A was oriented horizontally to ITO substrate, however, that in film-B was oriented vertically to GCE. Namely film-A corresponded to a layer structure, and film-B corresponded to an intercalation structure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Through layer-by-layer assembly, a series of undecatungstozincates monosubstituted by first-row transition metals, ZnW11M(H2O)O-39(n-) (M=Cr, Mn, Fe, Co, Ni, Cu. or Zn) were first successfully immobilized on a 4-aminobenzoic acid modified glassy carbon electrode surface. The electrochemical behaviors of these polyoxometalates were investigated. They exhibit some special properties in the films different from those in homogeneous aqueous solution. The Cu-centered reaction mechanism in the ZnW11Cu multilayer film was described. The electrocatalytic behaviors of these multilayer film electrodes to the reduction of H2O2 and BrO3- were comparatively studied.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Through layer-by-layer assembly, the bis-Keggin-type heteropolyanion K10H3 [Nd(SiMo7W4O39)(2)] XH2O was successfully immobilized on a glassy carbon electrode surface grafted covalently by 4-aminobenzoic acid. The electrochemical behavior of the heteropolyanion was investigated. Cyclic voltammetry proved the uniform growth of the film. However, the characteristic redox peaks of the heteropolyanion in the film were deformed with increasing of the number of the multilayer film. The effect of pH on the redox behaviors of [Nd(SiMo7W4)(2)](13-) in the film was discussed. The multilayer film electrodes have excellent electrocatalytic activities to the reduction of BrO3-, HNO2 and H2O2.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new type of inorganic-organic hybrid material incorporating carbon powder and alpha -type 2:18-molybdodiphosphate (P2Mo18) in a methyltrimethoxysilane (MTMOS) based gel has been produced by a sol-gel process and used to fabricate a chemically modified electrode. The P2Mo18-doped carbon ceramic composite electrode was characterized using SEM and cyclic voltammetry. Square-wave voltammetry with an excellent sensitivity was exploited to conveniently investigate the dependence of current and half-wave potential (E-1/2) on pH. The chemically modified electrode has some advantages over the modified film electrodes constructed by the conventional methods, such as long-term stability, reproducibility, and especially repeatability of surface-renewal by simple polishing in the event of surface fouling or dopant leaching. In addition, the modified electrode shows a good catalytic activity for the electrochemical reduction of bromate in an acidic aqueous solution. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Through layer-by-layer assembly, undecatungstozincates monosubstituted by transition metals Mn, ZnW11 Mn (H2O) O-39(8-) was successfully immobilized on a glassy carbon electrode surface grafted covalently by 4-aminobenzoic acid. The electrochemical behavior of these polyoxometalates was investigated. Cyclic voltammetry proves the uniform growth of the film. They exhibit some special electrochemical properties in the films, different from those in homogeneous aqueous solution. The effect of pH on the redox behavior of ZnW11Mn(H2O)O-39(8-) in the film was discussed in detail. The multilayer film electrodes have an excellent electrocatalytic response to the reduction of H2O2 and BrO3-, and to the oxidation of ascorbic acid.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The volumetric behavior of a chloride complex of palladium was studied at a glassy carbon electrode (GCE). The Pd-IV complex existing on the GCE surface was found, which was proposed to form an octahedral surface complex through coordination to the oxygen atom of an oxygen functional group on the pretreated GCE surface. The ferri/ferrocyanide redox couple was used as a probe to examine the activity of the GCE. X-ray photoelectron spectroscopy provided the evidence of the surface complex existing on the GCE. Highly dispersed Pd particles can be obtained when the surface complexes were reduced electrochemically to Pd atoms. The Pd particles obtained in this way were in nanometer scale and exhibit high catalytic activity towards the oxidation of hydrazine. (C) 1997 Elsevier Science Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A bismuth/multi-walled carbon nanotube (Bi/MWNT) composite modified electrode for determination of cobalt by differential pulse adsorptive cathodic stripping voltammetry is described. The electrode is fabricated by potentiostatic pre-plating bismuth film on an MWNT modified glassy carbon (GC) electrode. The Bi/MWNT composite modified electrode exhibits enhanced sensitivity for cobalt detection as compared with the bare GC, MWNT modified and bismuth film electrodes. Numerous key experimental parameters have been examined for optimum analytical performance of the proposed electrode. With an adsorptive accumulation of the Co(II)-dimethylglyoxime complex at -0.8 V for 200 s, the reduction peak current is proportional to the concentration of cobalt in the range of 4.0x10(-11)-1.0x10(-7) mol/L with a lower detection limit of 8.1x10(-11) mol/L. The proposed method has been applied Successfully to cobalt determination in seawater and lake water samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals. The proposed system provides the facilities found in a traditional lab-based instrument in a hand held a design. In contrast to existing commercial systems, it can stand alone without the need of an associated computer. The electrochemical instrument uses anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise disposable screen-printed (solid working) electrodes rather than the more common hanging mercury drop electrodes. The system is reliable, easy to use, safe, avoids expensive and time-consuming procedures and may be used in a variety of situations to help in the fields of environmental assessment and control.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A methodology for the determination of the pesticide chlorfenvinphos by microwave-assisted solvent extraction and square-wave cathodic stripping voltammetry at a mercury film ultramicroelectrode in soil samples is proposed. Optimization of microwave solvent extraction performed with two soils, selected for having significantly different properties, indicated that the optimum solvent for extracting chlorfenvinphos is hexane-acetone (1:1, v/v). The voltammetric procedure is based on controlled adsorptive accumulation of the insecticide at the potential of -0.60 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 6.2). The detection limit obtained for a 10 s collection time was 3.0 x 10-8 mol l-1. The validity of the developed methodology was assessed by recovery experiments at the 0.100 µg g-1 level. The average recoveries and standard deviations for the global procedure reached byMASE-square-wave voltammetry were 90.2±2.8% and 92.1±3.4% for type I (soil rich in organic matter) and type II (sandy soil) samples, respectively. These results are in accordance to the expected values which show that the method has a good accuracy.