The objective of this work was to study the morphology and biometry of the infraorbital foramen (FIO), variations in its shape, size and number as well as to obtain measurements of its location. 60 dry skulls were analyzed. The test of Qui-quadrant and the T Test were used in measurements with a 5% significance. On the right side, the FIO was measured at a distance of 6.49(+/- 1.68) mm from the lower, 39.65(+/- 3) mm from the upper, 17.7(+/- 2.97) mm from the medial and 20.46(+/- 2.9) mm from the lateral margin of the orbit; its pear-shaped opening distance was 13.67(+/- 2.17) mm. On the left side, the distance of the FIO to the lower margin of the orbit was 6.52(+/- 1.82) mm; to the upper margin was 39.9(+/- 2.62) mm and to the lateral and medial margin were 17.93(+/- 2.58) mm and 21.12(+/- 3) mm, respectively; its distance to the pear-shaped opening was 14.26(+/- 1.83) mm. It was found predominately in an oval shape, in 39 (65%) of the skulls, on both sides. Accessory foramens were present in 11 samples on the right and in 15 samples on the left side. The FIO was most frequently found on the side of, or laterally to the sagittal plane that passes through the middle of the supraorbital foramen/incisures, in 38 skulls (63.3%) on the right side and in 45 skulls (75%) on the left and middle to the zigomatic-maxillary suture, in 41 skulls (68.3%) on right and in 42 skulls (70%) on the left side, besides being most frequently found in a region between the first and second premolars, in 22 skulls (36.7%) on the right side and in 17 skulls (28.3%) on the left.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess, in vivo, the accuracy of the NovApex (R) electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex (R) was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex (R) locator and confirmed using the radiographic method. Differences between electronic and radiographic measurements ranging between 0.0 and 0.4 millimeters were classified as acceptable; differences equal to or greater than 0.5 millimeter were considered unacceptable. Pearson's chi-square test was used to assess the influence of pulp condition on the accuracy of NovApex (R) (alpha = 0.05). Regardless of pulp condition, differences between electronic and radiographic WL measurements were acceptable in 73.61% of the canals. No statistically significant differences in accuracy were observed when comparing vital and necrotic canals (p > 0.05). There were 38 unacceptable measurements. In none of these cases was the file tip located beyond the radiographic apex; in 32, it was located short of the NovApex (R) measurement. Pulp condition had no significant effect on the accuracy of NovApex (R).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate, ex vivo, the precision of five electronic root canal length measurement devices (ERCLMDs) with different operating systems: the Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15, and the possible influence of the positioning of the instrument tips short of the apical foramen. Material and Methods: Forty-two mandibular bicuspids had their real canal lengths (RL) previously determined. Electronic measurements were performed 1.0 mm short of the apical foramen (-1.0), followed by measurements at the apical foramen (0.0). The data resulting from the comparison of the ERCLMD measurements and the RL were evaluated by the Wilcoxon and Friedman tests at a significance level of 5%. Results: Considering the measurements performed at 0.0 and -1.0, the precision rates for the ERCLMDs were: 73.5% and 47.1% (Root ZX), 73.5% and 55.9% (Mini Apex Locator), 67.6% and 41.1% (Propex II), 61.7% and 44.1% (iPex), and 79.4% and 44.1% (RomiApex A-15), respectively, considering ±0.5 mm of tolerance. Regarding the mean discrepancies, no differences were observed at 0.0; however, in the measurements at -1.0, the iPex, a multi-frequency ERCLMD, had significantly more discrepant readings short of the apical foramen than the other devices, except for the Propex II, which had intermediate results. When the ERCLMDs measurements at -1.0 were compared with those at 0.0, the Propex II, iPex and RomiApex A-15 presented significantly higher discrepancies in their readings. Conclusions: Under the conditions of the present study, all the ERCLMDs provided acceptable measurements at the 0.0 position. However, at the -1.0 position, the ERCLMDs had a lower precision, with statistically significant differences for the Propex II, iPex, and RomiApex A-15.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since instrumentation of the apical foramen has been suggested for cleaning and disinfection of the cemental canal, selection of the file size and position of the apical foramen have challenging steps. This study analyzed the influence of apical foramen lateral opening and file size can exert on cemental canal instrumentation. Thirty-four human maxillary central incisors were divided in two groups: Group 1 (n=17), without flaring, and Group 2 (n=17), with flaring with LA Axxess burs. K-files of increasing diameters were progressively inserted into the canal until binding at the apical foramen was achieved and tips were visible and bonded with ethyl cyanoacrylate adhesive. Roots/files set were cross-sectioned 5 mm from the apex. Apices were examined by scanning electron microscopy at ×140 and digital images were captured. Data were analyzed statistically by Student’s t test and Fisher’s exact test at 5% significance level. SEM micrographs showed that 19 (56%) apical foramina emerged laterally to the root apex, whereas 15 (44%) coincided with it. Significantly more difficulty to reach the apical foramen was noted in Group 2. Results suggest that the larger the foraminal file size, the more difficult the apical foramen instrumentation may be in laterally emerged cemental canals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patent foramen ovale (PFO) has been linked to migraine, and an improvement in migraine prevalence or frequency has been reported after PFO closure for other reasons. We sought to identify whether there is a specific patient population of migraineurs which may be more susceptible to benefiting from PFO closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patent foramen ovale is found in 24% of healthy adults and 38% of patients with cryptogenic stroke. This ratio and case reports indicate that patent foramen ovale and stroke are associated, probably because of paradoxical embolism. In healthy people with patent foramen ovale, embolic events are not more frequent than in controls, and therefore no primary prevention is needed. However, once ischaemic events occur, the risk of recurrence is substantial and prevention becomes an issue. Acetylsalicylic acid and warfarin reduce this risk to the same level as in patients without patent foramen ovale. Patent foramen ovale with a coinciding atrial septal aneurysm, spontaneous or large right-to-left shunt, or multiple ischaemic events potentiates the risk of recurrence. Transcatheter device closure has therefore become an intriguing addition to medical treatment, but its therapeutic value still needs to be confirmed by randomised-controlled trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous closure of patent foramen ovale (PFO) has been shown safe and feasible using several devices. The Occlutech Figulla single layer PFO Occluder (FPO) constitutes an alternative to the Amplatzer PFO Occluder (APFO).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Migraine is a neurological disorder characterized by an increased individual susceptibility to respond to certain triggers by a propagating wave of neuronal depolarization that culminates in typical migraine headaches. Patients with a patent foramen ovale or any kind of right-to-left shunt are more likely to have migraine; and patients with migraine with aura are more likely to have a patent foramen ovale than patients without migraine. Nonrandomized reports of patent foramen ovale closure in divers, in patients with paradoxical embolism and in migraine patients with ischemic brain lesions have shown an impressive reduction in migraine headaches during follow-up. To date, the only double-blind, randomized controlled trial with a sham procedure in the control arm failed to show any benefit, probably owing to inadequate patient selection and maybe because of a high residual shunt rate. Two other randomized trials continue to enroll patients with migraine with aura and drug-refractory headaches and their results are awaited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Several studies have shown an association of cryptogenic stroke and embolism with patent foramen ovale (PFO), but the question how to prevent further events in such patients is unresolved. Options include antithrombotic treatment with warfarin or antiplatelet agents or surgical or endovascular closure of the PFO. The PC-Trial was set up to compare endovascular closure and best medical treatment for prevention of recurrent events. Methods The PC-Trial is a randomized clinical trial comparing the efficacy of percutaneous closure of the PFO using the Amplatzer PFO occluder with best medical treatment in patients with cryptogenic embolism, i.e. mostly cryptogenic stroke. Warfarin for 6 months followed by antiplatelet agents is recommended as medical treatment. Randomization is stratified according to patients age (<45 versus ≥45 years), presence of atrial septal aneurysm (ASA yes or no) and number of embolic events before randomization (one versus more than one event). Primary endpoints are death, nonfatal stroke and peripheral embolism. Discussion patients were randomized in 29 centers of Europe, Canada, and Australia. Randomization started February 2000. Enrollment of 414 patients was completed in February 2009. All patients will be followed-up longitudinally. Follow-up is maintained until the last enrolled patient is beyond 2.5 years of follow-up (expected in 2011).