951 resultados para Meios de contraste (Diagnóstico por imagem)
Resumo:
Subarachnoid infusion of most contrast mediums and the steps involved in performing a cervical myelography have adverse affects that can discourage its use in the radiographic diagnosis of spinal cord diseases. Thus, the cardiovascular and respiratory alterations associated with neck flexion, subarachnoid puncture, and cerebrospinal fluid drainage during subarachnoid infusion of ioversol (320mgI/mL) in dogs under general anesthesia using isoflurane were evaluated. The dogs received subarachnoid infusion of autologous cerebrospinal fluid kept at 38°C - control group (GC); ioversol 0.3mL/kg at 25°C (GI25) and ioversol 0.3mL/kg heated to 38°C (GI38). Each dog had its heart rate (HR), systolic arterial pressure (SAP), diastolic arterial pressure (DAP), respiratory rate (RR), oxyhemoglobin saturation (SaO2) and electrocardiography readings (PR and QT intervals) recorded. Group comparisons showed no statistical difference regarding neck positioning, subarachnoid puncture, and subarachnoid infusion of contrast medium on HR, RR and SaO2, cardiac rhythm or conduction. However, isoflurane significantly increased PR and QT intervals. Based on these findings, it is concluded that the steps involved in cervical myelography and the use of ioversol 320mgI/mL at 0.3mL/kg (25ºC and 38ºC) during cervical myelography did not result in relevant cardiovascular and respiratory alterations, except for an elevation in arterial pressure after injection of ioversol.
Resumo:
The modernization of image equipaments associate to the veterinary professionals qualification allowed an advance in diagnosis veterinary medicine, and, consequently, in premature pregnancy diagnosis in bitches. Currently, owners and creators search for information related to pregnancy detection, fetal development and viability and litter size determination. Through diagnosis methods as radiology and ultrasonography, associated to clinics aspects, the diagnosis of early pregnancy become more acurated and precise, allowing more quality in the accompaniment of prenatal of these bitches. Ultrasonographic exams help the accompaniment of these pregnancies through of visuals recourses, which can supply information related to pregnancy detection, embrionary and fetal development, fetal viability e litter size determination through fetals mensurations. The radiographic study has as principal indication the fetal counting, and has been the most acurated for this analyses. It may be done after the da s after the luteini ing hormone surge, when occurs the fetal mineralization. Due to its importance in the present time and in small animals clinic, the objective of this study is to discuss the main radiographics and ultrassonographics aspects of the diagnosis of pregnancy in bitches
Resumo:
Portosystemic shunt, an hepatobiliary anomaly, much common in dogs and less frequent in cats, can be detected by several diagnostic methods. Among them, the one which stands out is ultrasonography due to its numerous advantages: noninvasive, quick, accessible, relatively low cost and provides useful information relating to the other systems, apart from being a highly sensitive method. Portosystemic shunt diagnosis using ultrasonography becomes highly sensitive when associated with B-mode, color Doppler and pulsed Doppler. A bibliographic survey about portosystemic shunt ultrasonographic diagnosis was carried out, and the main ultrasonographic signals were: decreased hepatic size, difficulty in blood vessels visualization, presence of an anomalous vessel, tortuous with turbulent flow and, finally, increased portal blood flow velocity near the shunting vessel
Resumo:
This project aims the verification of doses in canines and felines to chest and coxal exams due to the transition from screen-film to computed radiography system. It also seeks a possible optimization of the new techniques employed in this new system. The study was carried out in Diagnostic Imaging service in Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo using a conventional x-ray equipment. Initially, data about the physical characteristics of animals and the technique currently used in computed radiography was collected for each of 80 chest and 16 coxal X-ray examinations. The animals were divided into different groups according to the body weight. For each group, were calculated the averages of each item: thickness of the region to be imaged, voltage, current, exposure time, current-time product, size of film used, presence or absence of bucky and focus (small or large). The techniques have been reproduced in phantoms (representative of the thickness of the animal) in order to collect the air kerma entrance. Based on the average of intermediate size M group (weights less than 5 kg for cats and from 10.1 kg and 20 kg for dogs) analysis of image quality using three devices test patterns were made consisting of the evaluation of spatial resolution, low-contrast resolution and contrast-detail. In general, the results showed the dose animals decreased with the use of computed radiography and was possible to preliminary optimization of some techniques used currently in CR
Resumo:
The equine locomotors system alterations are very frequent and corresponds a large portion of cases in equine medicine. The most equine veterinarian’s challenge is to do a precise diagnosis of lameness cause to perform a specific and proper treatment as early as possible. The navicular syndrome is considered responsible for one third of lameness causes and, although much studied, its etiology is still not fully understood. The most varied methods of diagnosis, such as x-ray, magnetic resonance, bursography, scintigraphy, computed tomography and ultrasound, have been used to assess podotrochlear apparatus situation in order to diagnose this syndrome. Among them transcuneal ultrasound can be used to observe some important structures such as the flexor surface of distal sesamoid bone, distal deep digital flexor tendon, distal sesamoid ligament entheses odd and the distal phalanx. The aim of this present paper is provide a brief review on the use and the technique of ultrasonography on third phalanx transcuneal region evaluation and its interpretation on navicular syndrome diagnosis in horses
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Objectives: The objective of this study was to evaluate the ability of endodontists and general practioners to perform the differential radiographic diagnosis between internal and external root resorptions, using digitized periapical radiographs. Methods: Thirty periapical radiographic images of external and internal resorption were selected. The evaluators were comprised of 15 endodontists and 29 general practitioners who answered a questionnaire with the following question: “What type of resorption in the following radiographics do you diagnose?” (1) Inflammatory external root resorption. (2) Internal root resorption. Statistical analysis was performed based on the Mann-Whitney test, with significance level of 5%. Results: There was no statistically significant difference in the percentage of correct answers from specialists in endodontics and general practitioners. Conclusions: Both groups demonstrated satisfactory skill in the radiographic interpretation of internal and external resorption and there was a higher percentage of correct diagnosis of internal resorption than the external.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O termo gossipiboma é usado para descrever uma massa formada a partir de uma matriz de algodão cercada por uma reação inflamatória/granulomatosa. Sua incidência é estimada em 0,15% a 0,2%. O corpo estranho na cavidade abdominal pode servir de nicho para a proliferação de microrganismos e agir como foco primário para formação de abscessos e de peritonite. Vários estudos têm demonstrado a importância da correlação clínica com os diversos métodos de imagem (radiografia convencional, ultrassonografia, tomografia computadorizada e ressonância magnética) no diagnóstico dos gossipibomas. Este ensaio tem por objetivo demonstrar uma série de casos típicos de gossipibomas abdominais e ilustrar suas diversas formas de apresentação, com ênfase nos achados dos diferentes métodos de imagem, visando a familiarizar os radiologistas com esta enfermidade e seus principais diagnósticos diferenciais.