977 resultados para Measurement results


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research extends the consumer-based brand equity measurement approach to the measurement of the equity associated with retailers. This paper also addresses some of the limitations associated with current retailer equity measurement such as a lack of clarity regarding its nature and dimensionality. We conceptualise retailer equity as a four-dimensional construct comprising retailer awareness, retailer associations, perceived retailer quality, and retailer loyalty. The paper reports the result of an empirical study of a convenience sample of 601 shopping mall consumers at an Australian state capital city. Following a confirmatory factor analysis using structural equation modelling to examine the dimensionality of the retailer equity construct, the proposed model is tested for two retailer categories: department stores and speciality stores. Results confirm the hypothesised four-dimensional structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The advection of relatively fresh Java Sea water through the Sunda Strait is presently responsible for the low-salinity "tongue" in the eastern tropical Indian Ocean with salinities as low as 32 per mil. The evolution of the hydrologic conditions in the eastern tropical Indian Ocean since the last glacial period, when the Sunda shelf was exposed and any advection via the Sunda Strait was cutoff, and the degree to which these conditions were affected by the Sunda Strait opening are not known. Here we have analyzed two sediment cores (GeoB 10042-1 and GeoB 10043-3) collected from the eastern tropical Indian Ocean off the Sunda Strait that cover the past ~40,000?years. We investigate the magnitude of terrigenous supply, sea surface temperature (SST), and seawater d18O (d18Osw) changes related to the sea level-driven opening of the Sunda Strait. Our new spliced records off the Sunda Strait show that during the last glacial, average SST was cooler and d18Osw was higher than elsewhere in the eastern tropical Indian Ocean. Seawater d18O decreased ~0.5 per mil after the opening of the Sunda Strait at ~10 kyr B.P. accompanied by an SST increase of 1.7°C. We suggest that fresher sea surface conditions have persisted ever since due to a continuous transport of low-salinity Java Sea water into the eastern tropical Indian Ocean via the Sunda Strait that additionally increased marine productivity through the concomitant increase in terrigenous supply.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

High-speed broadband internet access is widely recognised as a catalyst to social and economic development. However, the provision of broadband Internet services with the existing solutions to rural population, scattered over an extensive geographical area, remains both an economic and technical challenge. As a feasible solution, the Commonwealth Scientific and Industrial Research Organization (CSIRO) proposed a highly spectrally efficient, innovative and cost-effective fixed wireless broadband access technology, which uses analogue TV frequency spectrum and Multi-User MIMO (MUMIMO) technology with Orthogonal-Frequency-Division-Multiplexing (OFDM). MIMO systems have emerged as a promising solution for the increasing demand of higher data rates, better quality of service, and higher network capacity. However, the performance of MIMO systems can be significantly affected by different types of propagation environments e.g., indoor, outdoor urban, or outdoor rural and operating frequencies. For instance, large spectral efficiencies associated with MIMO systems, which assume a rich scattering environment in urban environments, may not be valid for all propagation environments, such as outdoor rural environments, due to the presence of less scatterer densities. Since this is the first time a MU-MIMO-OFDM fixed broadband wireless access solution is deployed in a rural environment, questions from both theoretical and practical standpoints arise; For example, what capacity gains are available for the proposed solution under realistic rural propagation conditions?. Currently, no comprehensive channel measurement and capacity analysis results are available for MU-MIMO-OFDM fixed broadband wireless access systems which employ large scale multiple antennas at the Access Point (AP) and analogue TV frequency spectrum in rural environments. Moreover, according to the literature, no deterministic MU-MIMO channel models exist that define rural wireless channels by accounting for terrain effects. This thesis fills the aforementioned knowledge gaps with channel measurements, channel modeling and comprehensive capacity analysis for MU-MIMO-OFDM fixed wireless broadband access systems in rural environments. For the first time, channel measurements were conducted in a rural farmland near Smithton, Tasmania using CSIRO's broadband wireless access solution. A novel deterministic MU-MIMO-OFDM channel model, which can be used for accurate performance prediction of rural MUMIMO channels with dominant Line-of-Sight (LoS) paths, was developed under this research. Results show that the proposed solution can achieve 43.7 bits/s/Hz at a Signal-to- Noise Ratio (SNR) of 20 dB in rural environments. Based on channel measurement results, this thesis verifies that the deterministic channel model accurately predicts channel capacity in rural environments with a Root Mean Square (RMS) error of 0.18 bits/s/Hz. Moreover, this study presents a comprehensive capacity analysis of rural MU-MIMOOFDM channels using experimental, simulated and theoretical models. Based on the validated deterministic model, further investigations on channel capacity and the eects of capacity variation, with different user distribution angles (θ) around the AP, were analysed. For instance, when SNR = 20dB, the capacity increases from 15.5 bits/s/Hz to 43.7 bits/s/Hz as θ increases from 10° to 360°. Strategies to mitigate these capacity degradation effects are also presented by employing a suitable user grouping method. Outcomes of this thesis have already been used by CSIRO scientists to determine optimum user distribution angles around the AP, and are of great significance for researchers and MU-MUMO-OFDM system developers to understand the advantages and potential capacity gains of MU-MIMO systems in rural environments. Also, results of this study are useful to further improve the performance of MU-MIMO-OFDM systems in rural environments. Ultimately, this knowledge contribution will be useful in delivering efficient, cost-effective high-speed wireless broadband systems that are tailor-made for rural environments, thus, improving the quality of life and economic prosperity of rural populations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A dynamic measurement system was developed by the Institute of Modern Physics (IMP) for the dipole prototype of Rapid Cycle Synchrotron (RCS) of China Spallation Neutron Source (CSNS). The repetition frequency of RCS is 25 Hz. The probe is a moving arc searching-coil, and the data acquisition system is based on the dynamic analysis modular of National Instrument. To get the error of high order harmonics of the field at basic frequency, the hardware integrator is replaced by a high speed ADC with software filter and integrator. A series of harmonic coefficients of field are used to express the varieties of dynamic fields in space and time simultaneously. The measurement system has been tested in Institute of High Energy Physics (IHEP), and the property of the dipole prototype of RCS has been measured. Some measurement results and the repeatability of system are illustrated in this paper.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We collaborate with environmental scientists to study the hydrodynamics and water quality in an urban district, where the surface wind distribution is an essential input but undergoes high spatial and temporal variations due to the complex urban landform created by surrounding buildings. In this work, we study an optimal sensor placement scheme to measure the wind distribution over a large urban reservoir with a limited number of wind sensors. Unlike existing sensor placement solutions that assume Gaussian process of target phenomena, this study measures the wind which inherently exhibits strong non-Gaussian yearly distribution. By leveraging the local monsoon characteristics of wind, we segment a year into different monsoon seasons which follow a unique distribution respectively. We also use computational fluid dynamics to learn the spatial correlation of wind in the presence of surrounding buildings. The output of sensor placement is a set of the most informative locations to deploy the wind sensors, based on the readings of which we can accurately predict the wind over the entire reservoir surface in real time. 10 wind sensors are finally deployed around or on the water surface of an urban reservoir. The in-field measurement results of more than 3 months suggest that the proposed sensor placement and spatial prediction approach provides accurate wind measurement which outperforms the state-of-the-art Gaussian model based or interpolation based approaches.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We study the water quality in an urban district, where the surface wind distribution is an essential input but undergoes high spatial and temporal variations due to the impact of surrounding buildings. In this work, we develop an optimal sensor placement scheme to measure the wind distribution over a large urban reservoir using a limited number of wind sensors. Unlike existing solutions that assume Gaussian process of target phenomena, this study measures the wind that inherently exhibits strong non-Gaussian yearly distribution. By leveraging the local monsoon characteristics of wind, we segment a year into different monsoon seasons that follow a unique distribution respectively. We also use computational fluid dynamics to learn the spatial correlation of wind. The output of sensor placement is a set of the most informative locations to deploy the wind sensors, based on the readings of which we can accurately predict the wind over the entire reservoir in real time. Ten wind sensors are deployed. The in-field measurement results of more than 3 months suggest that the proposed sensor placement and spatial prediction scheme provides accurate wind measurement that outperforms the state-of-the-art Gaussian model based on interpolation-based approaches.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Atmospheric aerosol particles serving as cloud condensation nuclei (CCN) are key elements of the hydrological cycle and climate. Knowledge of the spatial and temporal distribution of CCN in the atmosphere is essential to understand and describe the effects of aerosols in meteorological models. In this study, CCN properties were measured in polluted and pristine air of different continental regions, and the results were parameterized for efficient prediction of CCN concentrations.The continuous-flow CCN counter used for size-resolved measurements of CCN efficiency spectra (activation curves) was calibrated with ammonium sulfate and sodium chloride aerosols for a wide range of water vapor supersaturations (S=0.068% to 1.27%). A comprehensive uncertainty analysis showed that the instrument calibration depends strongly on the applied particle generation techniques, Köhler model calculations, and water activity parameterizations (relative deviations in S up to 25%). Laboratory experiments and a comparison with other CCN instruments confirmed the high accuracy and precision of the calibration and measurement procedures developed and applied in this study.The mean CCN number concentrations (NCCN,S) observed in polluted mega-city air and biomass burning smoke (Beijing and Pearl River Delta, China) ranged from 1000 cm−3 at S=0.068% to 16 000 cm−3 at S=1.27%, which is about two orders of magnitude higher than in pristine air at remote continental sites (Swiss Alps, Amazonian rainforest). Effective average hygroscopicity parameters, κ, describing the influence of chemical composition on the CCN activity of aerosol particles were derived from the measurement data. They varied in the range of 0.3±0.2, were size-dependent, and could be parameterized as a function of organic and inorganic aerosol mass fraction. At low S (≤0.27%), substantial portions of externally mixed CCN-inactive particles with much lower hygroscopicity were observed in polluted air (fresh soot particles with κ≈0.01). Thus, the aerosol particle mixing state needs to be known for highly accurate predictions of NCCN,S. Nevertheless, the observed CCN number concentrations could be efficiently approximated using measured aerosol particle number size distributions and a simple κ-Köhler model with a single proxy for the effective average particle hygroscopicity. The relative deviations between observations and model predictions were on average less than 20% when a constant average value of κ=0.3 was used in conjunction with variable size distribution data. With a constant average size distribution, however, the deviations increased up to 100% and more. The measurement and model results demonstrate that the aerosol particle number and size are the major predictors for the variability of the CCN concentration in continental boundary layer air, followed by particle composition and hygroscopicity as relatively minor modulators. Depending on the required and applicable level of detail, the measurement results and parameterizations presented in this study can be directly implemented in detailed process models as well as in large-scale atmospheric and climate models for efficient description of the CCN activity of atmospheric aerosols.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

One of the most significant aspects of a building’s acoustic behavior is the airborne sound insulation of the room façades, since this determines the protection of its inhabitants against environmental noise. For this reason, authorities in most countries have established in their acoustic regulations for buildings the minimum value of sound insulation that must be respected for façades. In order to verify compliance with legal requirements it is usual to perform acoustic measurements in the finished buildings and then compare the measurement results with the established limits. Since there is always a certain measurement uncertainty, this uncertainty must be calculated and taken into account in order to ensure compliance with specifications. The most commonly used method for measuring sound insulation on façades is the so-called Global Loudspeaker Method, specified in ISO 140-5:1998. This method uses a loudspeaker placed outside the building as a sound source. The loudspeaker directivity has a significant influence on the measurement results, and these results may change noticeably by choosing different loudspeakers, even though they all fulfill the directivity requirements of ISO 140-5. This work analyzes the influence of the loudspeaker directivity on the results of façade sound insulation measurement, and determines its contribution to measurement uncertainty. The theoretical analysis is experimentally validated by means of an intermediate precision test according to ISO 5725-3:1994, which compares the values of sound insulation obtained for a façade using various loudspeakers with different directivities

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Accurate characterization of the radio channel in tunnels is of great importance for new signaling and train control communications systems. To model this environment, measurements have been taken at 2.4 GHz in a real environment in Madrid subway. The measurements were carried out with four base station transmitters installed in a 2-km tunnel and using a mobile receiver installed on a standard train. First, with an optimum antenna configuration, all the propagation characteristics of a complex subway environment, including near shadowing, path loss,shadow fading, fast fading, level crossing rate (LCR), and average fade duration (AFD), have been measured and computed. Thereafter, comparisons of propagation characteristics in a double-track tunnel (9.8-m width) and a single-track tunnel (4.8-m width) have been made. Finally, all the measurement results have been shown in a complete table for accurate statistical modeling.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

One of the most significant aspects of a building?s acoustic behavior is the airborne sound insulation of the room façades, since this determines the protection of its inhabitants against environmental noise. For this reason, authorities in most countries have established in their acoustic regulations for buildings the minimum value of sound insulation that must be respected for façades. In order to verify compliance with legal requirements it is usual to perform acoustic measurements in the finished buildings and then compare the measurement results with the established limits. Since there is always a certain measurement uncertainty, this uncertainty must be calculated and taken into account in order to ensure compliance with specifications. The most commonly used method for measuring sound insulation on façades is the so-called Global Loudspeaker Method, specified in ISO 140-5:1998. This method uses a loudspeaker placed outside the building as a sound source. The loudspeaker directivity has a significant influence on the measurement results, and these results may change noticeably by choosing different loudspeakers, even though they all fulfill the directivity requirements of ISO 140-5. This work analyzes the influence of the loudspeaker directivity on the results of façade sound insulation measurement, and determines its contribution to measurement uncertainty. The theoretical analysis is experimentally validated by means of an intermediate precision test according to ISO 5725-3:1994, which compares the values of sound insulation obtained for a façade using various loudspeakers with different directivities. Keywords: Uncertainty, Façade, Insulation

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We present unified, systematic derivations of schemes in the two known measurement-based models of quantum computation. The first model (introduced by Raussendorf and Briegel, [Phys. Rev. Lett. 86, 5188 (2001)]) uses a fixed entangled state, adaptive measurements on single qubits, and feedforward of the measurement results. The second model (proposed by Nielsen, [Phys. Lett. A 308, 96 (2003)] and further simplified by Leung, [Int. J. Quant. Inf. 2, 33 (2004)]) uses adaptive two-qubit measurements that can be applied to arbitrary pairs of qubits, and feedforward of the measurement results. The underlying principle of our derivations is a variant of teleportation introduced by Zhou, Leung, and Chuang, [Phys. Rev. A 62, 052316 (2000)]. Our derivations unify these two measurement-based models of quantum computation and provide significantly simpler schemes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Multi-frequency eddy current measurements are employed in estimating pressure tube (PT) to calandria tube (CT) gap in CANDU fuel channels, a critical inspection activity required to ensure fitness for service of fuel channels. In this thesis, a comprehensive characterization of eddy current gap data is laid out, in order to extract further information on fuel channel condition, and to identify generalized applications for multi-frequency eddy current data. A surface profiling technique, generalizable to multiple probe and conductive material configurations has been developed. This technique has allowed for identification of various pressure tube artefacts, has been independently validated (using ultrasonic measurements), and has been deployed and commissioned at Ontario Power Generation. Dodd and Deeds solutions to the electromagnetic boundary value problem associated with the PT to CT gap probe configuration were experimentally validated for amplitude response to changes in gap. Using the validated Dodd and Deeds solutions, principal components analysis (PCA) has been employed to identify independence and redundancies in multi-frequency eddy current data. This has allowed for an enhanced visualization of factors affecting gap measurement. Results of the PCA of simulation data are consistent with the skin depth equation, and are validated against PCA of physical experiments. Finally, compressed data acquisition has been realized, allowing faster data acquisition for multi-frequency eddy current systems with hardware limitations, and is generalizable to other applications where real time acquisition of large data sets is prohibitive.