855 resultados para Measurement in Bacteriology
Resumo:
For radiation protection purposes, the neutron dose in carbon ion radiation therapy at the HIRFL (Heavy Ion Research Facility in Lanzhou) was investigated. The neutron dose from primary C-12 ions with a specific energy of 100 MeV/u delivered from SSC was roughly measured with a standard Anderson-Broun rem-meter using a polyethylene target at various distances. The result shows that a maximum neutron dose contribution of 19 mSv in a typically surface tumor treatment was obtained, which is less than 1% of the planed heavy ion dose and is in reasonable agreement with other reports. Also the gamma-ray dose was measured in this experiment using a thermo luminescent detector.
Resumo:
In this paper we study the ion transfer across the liquid/liquid interface by impedance spectrum technique in the four - electrode system. We present a method of getting the real interfacial impedance curve from the apparent impedance curve obtained in the four - electrode system. A practical kinetics investigation on the transfer of tetramethylammonium ion at the water/nitrobenzene interface was done with the method to verify the validity of the method. The transfer of tetramethylammonium ion at the W/O interface is really a reversible transfer.
Resumo:
Applying impedance spectrum technique to liquid/liquid interfacial electrochemistry, we present the theoretical expression of the liquid/liquid interfacial impedance in the four - electrode electrolytic cell measured by alternating current impedance method. The influence of the electrolytic cell parameters and input passage parameters of the impedance apparatus on impedance spectrum curves are theoretically studied.
Resumo:
The method for the measurement of the pure mechanical wear loss for 321 stainless steel, 1045 steel and pure iron in the study of the synergy between corrosion and wear was studied, The methods studied included the measurement in distilled water, by cathodic protection and by adding inhibitor KI, and all were compared with the wear loss in air. The experiment showed that the pure mechanical wear losses and friction coefficients obtained by the three methods were close to each other and can be used to calculate the various wear components in the study of the interaction of corrosion and wear, but the measurements in distilled water for pure iron and 1045 steel are not recommended due to their corrosion.
Resumo:
Traditional motion capture techniques, for instance, those employing optical technology, have long been used in the area of rehabilitation, sports medicine and performance analysis, where accurately capturing bio-mechanical data is of crucial importance. However their size, cost, complexity and lack of portability mean that their use is often impractical. Low cost MEMS inertial sensors when combined and assembled into a Wireless Inertial Measurement Unit (WIMU) present a possible solution for low cost and highly portable motion capture. However due to the large variability inherent to MEMS sensors, such a system would need extensive characterization to calibrate each sensor and ensure good quality data capture. A completely calibrated WIMU system would allow for motion capture in a wider range of real-world, non-laboratory based applications. Calibration can be a complex task, particularly for newer, multi-sensing range capable inertial sensors. As such we present an automated system for quickly and easily calibrating inertial sensors in a packaged WIMU, demonstrating some of the improvements in accuracy attainable.