983 resultados para Massenspektrometrie, CE-ICP-MS, Actiniden
Resumo:
LA-MC-ICP-MS U-Pb zircon dating was performed on syntectonic, early post-collisional granitic and associated mafic rocks that are intrusive in the Brusque Metamorphic Complex and in the Florianopolis Batholith, major tectonic domains separated by the Neoproterozoic Major Gercino Shear Zone (MGSZ) in south Brazil. The inferred ages of magmatic crystallization are consistent with field relationships, and show that the syntectonic granites from both domains are similar, with ages around 630-620 Ma for high-K calc-alkaline metaluminous granites and ca. 610 Ma for slightly peraluminous granites. Although ca. 650 Ma inherited zircon components are identified in granites from both domains, important contrasts on the crustal architecture in each domain are revealed by the patterns of zircon inheritance, indicating different crustal sources for the granites in each domain. The granites from the southern domain (Floriandpolis Batholith) have essentially Neoproterozoic (650-700 Ma and 900-950 Ma) inheritance; with a single 2.0-2.2 Ga inherited age obtained in the peraluminous Mariscal Granite. In the northern Brusque Metamorphic Complex, the metaluminous Rio Pequeno Granite and associated mafic rocks have scarce inherited cores with ages around 1.65 Ga, whereas the slightly peraluminous Serra dos Macacos Granite has abundant Paleoproterozoic (1.8-2.2 Ga) and Archean (2.9-3.4 Ga) inherited zircons. Our results are consistent with the hypothesis that the MGSZ separates domains with distinct geologic evolution; however, the contemporaneity of 630-610 Ma granitic magmatism with similar structural and geochemical patterns on both sides of this major shear zone indicates that these domains were already part of a single continental mass at 630 Ma, reinforcing the post-collisional character of these granites. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
The LA-MC-ICP-MS method applied to U-Pb in situ dating is still rapidly evolving due to improvements in both lasers and ICP-MS. To test the validity and reproducibility of the method, 5 different zircon samples, including the standard Temora-2, ranging in age between 2.2 Ga and 246 Ma, were dated using both LA-MC-ICP-MS and SHRIMP. The selected zircons were dated by SHRIMP and, after gentle polishing, the laser spot was driven to the same site or on the same zircon phase with a 213 nm laser microprobe coupled to a multi-collector mixed system. The data were collected with a routine spot size of 25 μm and, in some cases, of 15 and 40 μm. A careful cross-calibration using a diluted U-Th-Pb solution to calculate the Faraday reading to counting rate conversion factors and the highly suitable GJ-1 standard zircon for external calibrations were of paramount importance for obtaining reliable results. All age results were concordant within the experimental errors. The assigned age errors using the LA-MC-ICP-MS technique were, in most cases, higher than those obtained by SHRIMP, but if we are not faced with a high resolution stratigraphy, the laser technique has certain advantages.
Resumo:
Im Rahmen dieser Arbeit ist es gelungen, ein GC/ICP-MSIVA-Verfahren zur zuverlässigen und richtigen Bestimmung von Methylquecksilbergehalten (MeHg+) in aquatischen Systemen zu entwickeln. Unter Verwendung eines hergestellten Me201Hg+-Indikators konnte bei der Überprüfung der weltweit gängigen Probenaufbereitung mittels NaBEt4 zur Überführung von MeHg+ in MeEtHg gezeigt werden, daß während dieser Probenaufbereitung in Gegenwart von Halogeniden eine MeHg+-Speziesumwandlung zu Hg0 stattfinden kann. Es konnte mit Hilfe von Modellösungen erstmalig eindeutig nachgewiesen werden, daß die MeHg+-Speziesumwandlungen ihre Ursache nur im Zusammenwirken von vorliegenden Halogeniden mit dem verwendeten Derivatisierungsreagenz NaBEt4 haben. Ebenso wie in Modellösungen wurden auch MeHg+-Speziesumwandlungen in Realproben bei der Derivatisierung mit NaBEt4 überprüft. Die Proben, die bei der Derivatisierung mit NaBEt4 eine MeHg+-Umwandlung zeigten, wurden auch mit dem weltweit bisher wenig eingesetzten Reagenz NaBPr4 derivatisiert. Hier konnte bei keiner der Untersuchungen eine MeHg+-Umwandlung festgestellt werden. Des weiteren wurden MeHg+-Gehalte in Süßwasserproben unter Verwendung von NaBEt4 und NaBPr4 bestimmt. Die Ergebnisse hinsichtlich beider Derivatisierungsreagenzien stimmten sehr gut überein. Diese Resultate zeigten eindrucksvoll, daß Substanzverluste durch die Speziesumwandlung bei MeHg+-Bestimmungen mit MSIVA keine Rolle spielen, da die Umwandlung erst nach der Isotopenvermischung einsetzte. Mit dem entwickelten GC/ICP-MSIVA-Verfahrens wurde der MeHg+-Gehalt im Referenzmaterial CRM 463 analysiert, der sehr gut mit dem zertifizierten Wert übereinstimmte.
Resumo:
Deutsch:Schwerpunkt dieser Arbeit war die Entwicklung einer Methode zur Spurenbestimmung von Silicium in organischen und anorganischen Matrices unter Verwendung der massenspektrometrischen Isotopenverdünnungsanalyse (MSIVA) an einem hochauflösenden induktiv gekoppelten Plasma-Massenspektrometer (HR-ICP-MS). Zusätzlich zur Elementspurenbestimmung wurde eine GC/HR-ICP-MS Kopplung entwickelt, die zur Analyse linearer und cyclischer Siloxane verwendet wurde.Die hier entwickelte Analysenmethode erlaubt Nachweisgrenzen für Silicium sowohl in organischen als auch in anorganischen Matrices im oberen ng/g-Bereich und ergab für die im Rahmen dieser Arbeit analysierten Proben Reproduzierbarkeiten von < 20%. Durch einfache Verdünnung nach der Probenvorbereitung in Verbindung mit dem sehr empfindlichen Detektionsverfahren sowie der internen Standardisierung mittels MSIVA erlaubt das Verfahren eine präzise Bestimmung von Silicium in jeglicher Matrix. Neben der Schnelligkeit und Einfachheit eignet sich die hier entwickelte Methode besonders für die Routineanalytik. Die gute Reproduzierbarkeit und der Vergleich mit Ergebnissen von zwei Interlaborstudien unterstreicht zusätzlich die Fähigkeit präzise und richtige Ergebnisse zur Zertifizierung an Standardreferenzmaterialien bezüglich des Siliciums im Spurenbereich zu liefern.Neben dem Gesamtgehalt von Silicium konnten medizinisch relevante Siliciumverbindungen analysiert und quantifiziert werden. Hierbei wurden niedermolekulare Polydimethlysiloxane (PDMS) untersucht, die als Nebenprodukte vor allem in Brustimplantaten auftreten. Grundlage für die Bestimmung dieser Siliciumspezies ist die Kopplung eines hochauflösenden ICP-MS an einen Gaschromatographen. Der hohe Ionisierungsgrad des ICP, gerade unter trockenen Plasmabedingungen, und der elementspezifische und sehr empfindliche massenspektrometrische Detektor erlauben in Verbindung mit dem GC die Bestimmung von Siloxanen bis in den pg/g-Bereich. Aus der Bestimmung des Gesamtgehalts an Silicium und der Bestimmung des Gehalts an den untersuchten Siliciumverbindungen können Vergleiche gemacht werden. Die Analyse beider Parameter ist mit Hilfe in dieser Arbeit entwickelten Methode möglich.Zusätzlich zur Siliciumbestimmung wurde der Gehalt an Platin in Humanproben analysiert, da bei der Herstellung der Füllung von Siliconimplantaten Platinkatalysatoren verwendet werden.
Resumo:
Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.
Resumo:
Plutonium represents the major contribution to the radiotoxicity of spent nuclear fuel over storage times of up to several hundred thousand years. The speciation of plutonium in aquifer systems is important in order to assess the risks of high-level nuclear waste disposal and to acquire a deep knowledge of the mobilization and immobilization behavior of plutonium. In aqueous solutions, plutonium can coexist in four oxidation states and each one of them has different chemical and physical behavior. Tetravalent plutonium is the most abundant under natural conditions. Therefore, detailed speciation studies of tetravalent plutonium in contact with humic substances (HS) and kaolinite as a model clay mineral have been performed in this work. Plutonium is present in the environment at an ultratrace level. Therefore, speciation of Pu at the ultratrace level is mandatory. Capillary electrophoresis (CE) coupled to resonance ionization mass spectrometry (RIMS) was used as a new speciation method. CE-RIMS enables to improve the detection limit for plutonium species by 2 to 3 orders of magnitude compared to the previously developed CE-ICP-MS. For understanding the behavior of Pu(IV) in aqueous systems, redox reactions, complexation, and sorption behavior of plutonium were studied. The redox behavior of plutonium in contact with humic acid (HA) and fulvic acid (FA) was investigated. A relatively fast reduction of Pu(VI) in contact with HS was observed. It was mainly reduced to Pu(IV) and Pu(III) within a couple of weeks. The time dependence of the Pu(IV) complexation with Aldrich HA was investigated and a complex constant (logßLC) between 6.4 - 8.4 of Pu(IV) was determined by means of ultrafiltration taking into account the loading capacity (LC). The sorption of tetravalent plutonium onto kaolinite was investigated as a function of pH in batch experiments under aerobic and anaerobic conditions. The sorption edge was found at about pH = 1 and a maximum sorption at around pH = 8.5. In the presence of CO2 at pH > 8.5, the sorption of plutonium was decreased probably due to the formation of soluble carbonate complexes. For comparison, the sorption of Th(IV) onto kaolinite was also investigated and consistent results were found. The Pu(IV) sorption onto kaolinite was studied by XANES and EXAFS at pH 1, 4, 9 and the sorbed species on kaolinite surface was Pu(IV). Depending on the pH, only 1 - 10 % of the sorbed plutonium is desorbed from kaolinite and released into a fresh solution at the same pH value. Furthermore, the sorption of HS onto kaolinite was studied as a function of pH at varying concentrations of HS, as a prerequisite to understand the more complex ternary system. The sorption of HA onto kaolinite was found to be higher than that of FA. The investigation of the ternary systems (plutonium-kaolinite-humic substances) is performed as a function of pH, concentration of HS, and the sequences of adding the reactants. The presence of HS strongly influences the sorption of Pu(IV) onto kaolinite over the entire pH range. For comparison, the influence of HS on the sorption of Th(IV) onto kaolinite was also investigated and a good agreement with the results of Pu(IV) was obtained.
Resumo:
Die qualitative und quantitative Analyse von Biomolekülen hat in den letzten Jahren und Jahrzehnten immer mehr an Bedeutung gewonnen. Durch das Aufkommen und die kontinuierliche Weiterentwicklung neuer Separations- und Detektionsmethoden und deren Verbindung miteinander zu leistungsfähigen Einheiten, erlangte man Schritt für Schritt neue Erkenntnisse bei ihrer Untersuchung. Die Elementmassenspektrometrie als nachweisstarke Detektionsmethode wird von vielen wissenschaftlichen Arbeitsgruppen bei der Trennung und Quantifizierung von Proteinen und Metalloproteinen mittels Detektion der in den Biomolekülen vorkommenden Metalle und Heteroatome angewendet. Heteroatome (z.B. Schwefel, Phosphor) haben im Plasma des ICP-MS (inductively coupled plasma - mass spectrometer) schlechte Ionisationseigenschaften und dementsprechend deutlich höhere Nachweisgrenzen als Metalle. Ein Ansatz, schlecht oder nicht detektierbare Verbindungen (also solche, die keine Metalle oder Heteroatome enthalten) mit dem ICP-MS sichtbar zu machen, ist die Markierung der selbigen mit Metallionen oder -cluster. rnIn dieser Arbeit ist es gelungen, der Analyse ganz unterschiedlicher Substanzklassen, zum einen metallische Nanopartikel und zum anderen Proteine, neue Impulse zu geben und zukünftiges Potential bei der Anwendung gekoppelter Techniken zur Separation und Detektion aufzuzeigen. Durch die Verwendung einer alten, aber neu konzipierten Trenntechnik, der Gelelektrophorese (GE), und deren Kopplung an einen modernen Detektor, dem ICP-MS, kann die für die Proteinanalytik weit verbreitete Gelelektrophorese ihr enormes Potential bei der Trennung verschiedenster Verbindungsklassen mit der exzellenten Nachweisstärke und Elementspezifität des ICP-MS verbinden und dadurch mit deutlich weniger Arbeitsaufwand als bisher qualitative und auch quantitative Ergebnisse produzieren. Bisher war dies nur mit großem präparativem Aufwand unter Verwendung der laser ablation möglich. Bei der Analyse von Nanopartikeln konnte aufgezeigt werden, dass durch die GE-ICP-MS-Kopplung aufgrund der guten Trenneigenschaften der GE vorhandene Spezies bzw. Fraktionen voneinander separiert werden und mit Hilfe des ICP-MS Informationen auf atomarem Niveau gewonnen werden können. Es war möglich, das atomare Verhältnis der Metallatome im Kern und der Schwefelatome in der Ligandenhülle eines Nanopartikels zu bestimmen und damit die Größe des Partikels abzuschätzen. Auch konnte die Anzahl der Goldatome in einem dem Schmid-Cluster ähnlichen Nanopartikel bestimmt werden, was vorher nur mit Hilfe von MALDI-TOF möglich war. Bei der Analyse von Biomolekülen konnte auf einfache Weise der Phosphorylierungsgrad verschiedener Proteine bestimmt werden. Auch bei kleinen Molekülen erzielt die Gelelektrophorese ausgezeichnete Trennergebnisse, wie z. B. bei der Analyse verschiedener Brom- und Iodspezies.rnDie stöchiometrische Kopplung eines Proteins an einen Nanopartikel, ohne eine der beiden Verbindungen in einem größeren Maße zu verändern, stellte jedoch eine Herausforderung dar, die im Rahmen dieser Arbeit nicht vollständig gelöst werden konnte. Verschiedene Ansätze zur Kopplung der beiden Substanzen wurden erprobt, jedoch führte keine zu dem gewünschten Ergebnis einer stöchiometrisch vollständigen und spezifischen Modifikation eines Proteins mit einem Nanopartikel. Durch das Potential der GE-ICP-MS-Kopplung bei der Analyse beider Substanz-klassen und dem Beweis der Praktikabilität und Zuverlässigkeit der Methode ist jedoch der Grundstein für weitere Forschungen auf diesem Gebiet gelegt worden. Ist eine geeignete chemische Kopplung der beiden Substanzklassen gefunden und beherrscht, steht auf analytischer Seite eine leistungsstarke Kombination aus Trennung und Detektion zur Verfügung, um die Quantifizierung von Proteinen entscheidend zu verbessern.rn