991 resultados para MECHANICAL FLOCCULATION UNIT


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stretching a stacked sPP lamellar morphology at room temperature leads to a mechanical induced transformation from the (t(2)g(2))(2) (helical) into the (tttt) (zigzag) chain conformation of the polymer. The so prepared samples exhibit after annealing above 80 degreesC a thermal induced retransformation into the cell I and cell III crystal structure of the helical chain conformation. The mechanical induced chain conformational transformation as well as the thermal induced retransformation was studied by means of transmission electron microscopy and electron diffraction. (C) 2001 Kluwer Academic Publishers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This experimental study examines the role of formulated molecular weight between crosslink sites on the temperature resistance and mechanical properties of composites based on a polyimide containing a diphenyl thioether unit (PTI). The composites are fabricated by in situ polymerization of monomer reactants (PMR) using three monomeric ingredients: bis(3,4-dicarboxyphenyl) sulfide dianhydride (TDPA); 4,4'-methylene dianiline (MDA); and the monomethyl ester of norbornene anhydride (NE). By changing monomeric molar ratio, three formulations are prepared, in which formulated molecular weight between crosslink sites varies from 1487 to 3446 g mol(-1). Unidirectional composite laminates from each formulation and T300 carbon fibres are compression moulded and cut into a series of test specimens. By measuring the glass transition temperature (T-g), Mode I interlaminar fracture toughness (G(IC)) and other mechanical properties at room and elevated temperatures, the influences of formulated molecular weight on the temperature resistance and mechanical properties of PTI-based composites are investigated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BackgroundMechanical ventilation is important in caring for patients with critical illness. Clinical complications, increased mortality, and high costs of health care are associated with prolonged ventilatory support or premature discontinuation of mechanical ventilation. Weaning refers to the process of gradually or abruptly withdrawing mechanical ventilation. the weaning process begins after partial or complete resolution of the underlying pathophysiology precipitating respiratory failure and ends with weaning success (successful extubation in intubated patients or permanent withdrawal of ventilatory support in tracheostomized patients).ObjectivesTo evaluate the effectiveness and safety of two strategies, a T-tube and pressure support ventilation, for weaning adult patients with respiratory failure that required invasive mechanical ventilation for at least 24 hours, measuring weaning success and other clinically important outcomes.Search methodsWe searched the following electronic databases: Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 6); MEDLINE (via PubMed) (1966 to June 2012); EMBASE (January 1980 to June 2012); LILACS (1986 to June 2012); CINAHL (1982 to June 2012); SciELO (from 1997 to August 2012); thesis repository of CAPES (Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior) (http://capesdw.capes.gov.br/capesdw/) (August 2012); and Current Controlled Trials (August 2012).We reran the search in December 2013. We will deal with any studies of interest when we update the review.Selection criteriaWe included randomized controlled trials (RCTs) that compared a T-tube with pressure support (PS) for the conduct of spontaneous breathing trials and as methods of gradual weaning of adult patients with respiratory failure of various aetiologies who received invasive mechanical ventilation for at least 24 hours.Data collection and analysisTwo authors extracted data and assessed the methodological quality of the included studies. Meta-analyses using the random-effects model were conducted for nine outcomes. Relative risk (RR) and mean difference (MD) or standardized mean difference (SMD) were used to estimate the treatment effect, with 95% confidence intervals (CI).Main resultsWe included nine RCTs with 1208 patients; 622 patients were randomized to a PS spontaneous breathing trial (SBT) and 586 to a T-tube SBT. the studies were classified into three categories of weaning: simple, difficult, and prolonged. Four studies placed patients in two categories of weaning. Pressure support ventilation (PSV) and a T-tube were used directly as SBTs in four studies (844 patients, 69.9% of the sample). in 186 patients (15.4%) both interventions were used along with gradual weaning from mechanical ventilation; the PS was gradually decreased, twice a day, until it was minimal and periods with a T-tube were gradually increased to two and eight hours for patients with difficult and prolonged weaning. in two studies (14.7% of patients) the PS was lowered to 2 to 4 cm H2O and 3 to 5 cm H2O based on ventilatory parameters until the minimal PS levels were reached. PS was then compared to the trial with the T-tube (TT).We identified 33 different reported outcomes in the included studies; we took 14 of them into consideration and performed meta-analyses on nine. With regard to the sequence of allocation generation, allocation concealment, selective reporting and attrition bias, no study presented a high risk of bias. We found no clear evidence of a difference between PS and TT for weaning success (RR 1.07, 95% CI 0.97 to 1.17, 9 studies, low quality of evidence), intensive care unit (ICU) mortality (RR 0.81, 95% CI 0.53 to 1.23, 5 studies, low quality of evidence), reintubation (RR 0.92, 95% CI 0.66 to 1.26, 7 studies, low quality evidence), ICU and long-term weaning unit (LWU) length of stay (MD -7.08 days, 95% CI -16.26 to 2.1, 2 studies, low quality of evidence) and pneumonia (RR 0.67, 95% CI 0.08 to 5.85, 2 studies, low quality of evidence). PS was significantly superior to the TT for successful SBTs (RR 1.09, 95% CI 1.02 to 1.17, 4 studies, moderate quality of evidence). Four studies reported on weaning duration, however we were unable to combined the study data because of differences in how the studies presented their data. One study was at high risk of other bias and four studies were at high risk for detection bias. Three studies reported that the weaning duration was shorter with PS, and in one study the duration was shorter in patients with a TT.Authors' conclusionsTo date, we have found evidence of generally low quality from studies comparing pressure support ventilation (PSV) and with a T-tube. the effects on weaning success, ICU mortality, reintubation, ICU and LWU length of stay, and pneumonia were imprecise. However, PSV was more effective than a T-tube for successful spontaneous breathing trials (SBTs) among patients with simple weaning. Based on the findings of single trials, three studies presented a shorter weaning duration in the group undergoing PS SBT, however a fourth study found a shorter weaning duration with a T-tube.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Web-based decision aids are increasingly important in medical research and clinical care. However, few have been studied in an intensive care unit setting. The objectives of this study were to develop a Web-based decision aid for family members of patients receiving prolonged mechanical ventilation and to evaluate its usability and acceptability. METHODS: Using an iterative process involving 48 critical illness survivors, family surrogate decision makers, and intensivists, we developed a Web-based decision aid addressing goals of care preferences for surrogate decision makers of patients with prolonged mechanical ventilation that could be either administered by study staff or completed independently by family members (Development Phase). After piloting the decision aid among 13 surrogate decision makers and seven intensivists, we assessed the decision aid's usability in the Evaluation Phase among a cohort of 30 surrogate decision makers using the Systems Usability Scale (SUS). Acceptability was assessed using measures of satisfaction and preference for electronic Collaborative Decision Support (eCODES) versus the original printed decision aid. RESULTS: The final decision aid, termed 'electronic Collaborative Decision Support', provides a framework for shared decision making, elicits relevant values and preferences, incorporates clinical data to personalize prognostic estimates generated from the ProVent prediction model, generates a printable document summarizing the user's interaction with the decision aid, and can digitally archive each user session. Usability was excellent (mean SUS, 80 ± 10) overall, but lower among those 56 years and older (73 ± 7) versus those who were younger (84 ± 9); p = 0.03. A total of 93% of users reported a preference for electronic versus printed versions. CONCLUSIONS: The Web-based decision aid for ICU surrogate decision makers can facilitate highly individualized information sharing with excellent usability and acceptability. Decision aids that employ an electronic format such as eCODES represent a strategy that could enhance patient-clinician collaboration and decision making quality in intensive care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:
Internationally, nurse-directed protocolised-weaning has been evaluated by measuring its impact on patient outcomes. The impact on nurses’ views and perceptions has been largely ignored.

Aim:
To determine the change in intensive care nurses’ perceptions, satisfaction, knowledge and attitudes following the introduction of nurse-directed weaning. Additionally, views were obtained on how useful protocolised-weaning was to practice.

Methods:
The sample comprised nurses working in general intensive care units in three university-affiliated hospitals. Nurse-directed protocolised-weaning was implemented in one unit (intervention group); two ICUs continued with usual doctor-led practice (control group). Nurses’ perceptions, satisfaction, knowledge and attitudes were measured by self-completed questionnaires before (Phase I) and after the implementation of nurse-directed weaning (Phase II) in all units.

Results:
Response rates were 79% (n=140n=140) for Phase 1 and 62% (n=132n=132) for Phase II. Regression-based analyses showed that changes from Phase I to Phase II were not significantly different between the intervention and control groups. Sixty-nine nurses responded to both Phase I and II questionnaires. In the intervention group, these nurses scored their mean perceived level of knowledge higher in Phase II (6.39 vs 7.17, p=0.01p=0.01). In the control group, role perception (4.41 vs 4.22, p=0.01p=0.01) was lower and, perceived knowledge (6.03 vs 6.63, p=0.04p=0.04), awareness of weaning plans (6.09 vs 7.06, p=0.01p=0.01) and satisfaction with communication (5.28 vs 6.19, p=0.01p=0.01) were higher in Phase II. The intervention group found protocolised weaning useful in their practice (75%): this was scored significantly higher by junior and senior nurses than middle grade nurses (p=0.02p=0.02).

Conclusion

We conclude that nurse-directed protocolised-weaning had no effect on nurses’ views and perceptions due to the high level of satisfaction which encouraged nurses’ participation in weaning throughout. Control group changes are attributed to a ‘reactive effect’ from being study participants. Weaning protocols provide a uniform method of weaning practice and are particularly beneficial in providing safe guidance for junior staff.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using a before and after study design, we compared protocolised weaning from mechanical ventilation with usual non-protocolised practice in intensive care. Outcomes (duration of mechanical ventilation, duration of intubation, intensive care stay) and complications (re-intubations, tracheostomy, mortality) were compared between baseline (Phase I) and following implementation of protocolised weaning (Phase II). Over the same period, we collected data in a second (reference) unit to monitor practice changes over time. In the intervention unit, outcomes were longer in Phase II compared with Phase I (all p < 0.005). When adjusted for admission APACHE II score and diagnostic category, only intensive care stay remained significantly longer (p = 0.002). There were significantly more tracheostomies in Phase II (p = 0.004). The reference unit demonstrated no statistically significant differences in study outcomes or complications between Phases. Protocolised weaning did not reduce the duration of mechanical ventilation and was not associated with an increased rate of re-intubation or intensive care unit mortality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective
Preliminary assessment of an automated weaning system (SmartCare™/PS) compared to usual management of weaning from mechanical ventilation performed in the absence of formal protocols.


Design and setting
A randomised, controlled pilot study in one Australian intensive care unit.


Patients
A total of 102 patients were equally divided between SmartCare/PS and Control.

Interventions
The automated system titrated pressure support, conducted a spontaneous breathing trial and provided notification of success (“separation potential”).

Measurements and results
The median time from the first identified point of suitability for weaning commencement to the state of “separation potential” using SmartCare/PS was 20 h (interquartile range, IQR, 2–40) compared to 8 h (IQR 2–43) with Control (log-rank P = 0.3). The median time to successful extubation was 43 h (IQR 6–169) using SmartCare/PS and 40 (14–87) with Control (log-rank P = 0.6). Unadjusted, the estimated probability of reaching “separation potential” was 21% lower (95% CI, 48% lower to 20% greater) with SmartCare/PS compared to Control. Adjusted for other covariates (age, gender, APACHE II, SOFAmax, neuromuscular blockade, corticosteroids, coma and elevated blood glucose), these estimates were 31% lower (95% CI, 56% lower to 9% greater) with SmartCare/PS. The study groups showed comparable rates of reintubation, non-invasive ventilation post-extubation, tracheostomy, sedation, neuromuscular blockade and use of corticosteroids.

Conclusions
Substantial reductions in weaning duration previously demonstrated were not confirmed when the SmartCare/PS system was compared to weaning managed by experienced critical care specialty nurses, using a 1:1 nurse-to-patient ratio. The effect of SmartCare/PS may be influenced by the local clinical organisational context.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The three-dimensional (3D) weaving process offers the ability to tailor the mechanical properties via design of the weave architecture. One repeat of the 3D woven fabric is represented by the unit cell. The model accepts basic weaver and material manufacturer data as inputs in order to calculate the geometric characteristics of the 3D woven unit cell. The specific weave architecture manufactured and subsequently modelled had an angle interlock type binding configuration. The modelled result was shown to have a close approximation compared to the experimentally measured values and highlighted the importance of the representation of the binder tow path.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A non-linear lumped model of the reed-mouthpiece-lip system of a clarinet is formulated, in which the lumped parameters are derived from numerical experiments with a finite-difference simulation based on a distributed reed model. The effective stiffness per unit area is formulated as a function of the pressure signal driving the reed, in order to simulate the effects of the reed bending against the lay, and mass and damping terms are added as a first approximation to the dynamic behaviour of the reed. A discrete-time formulation is presented, and its response is compared to that of the distributed model. In addition, the lumped model is applied in the simulation of clarinet tones, enabling the analysis of the effects of using a pressure-dependent stiffness per unit area on sustained oscillations. The analysed effects and features are in qualitative agreement with players' experiences and experimental results obtained in prior studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To investigate the effects of weaning protocols on the total duration of mechanical ventilation, mortality, adverse events, quality of life, weaning duration, and length of stay in the intensive care unit and hospital.

Design Systematic review.

Data sources Cochrane Central Register of Controlled Trials, Medline, Embase, CINAHL, LILACS, ISI Web of Science, ISI Conference Proceedings, Cambridge Scientific Abstracts, and reference lists of articles. We did not apply language restrictions.

Review methods We included randomised and quasi-randomised controlled trials of weaning from mechanical ventilation with and without protocols in critically ill adults.

Data selection Three authors independently assessed trial quality and extracted data. A priori subgroup and sensitivity analyses were performed. We contacted study authors for additional information.

Results Eleven trials that included 1971 patients met the inclusion criteria. Compared with usual care, the geometric mean duration of mechanical ventilation in the weaning protocol group was reduced by 25% (95% confidence interval 9% to 39%, P=0.006; 10 trials); the duration of weaning was reduced by 78% (31% to 93%, P=0.009; six trials); and stay in the intensive care unit length by 10% (2% to 19%, P=0.02; eight trials). There was significant heterogeneity among studies for total duration of mechanical ventilation (I(2)=76%, P

Conclusion There is evidence of a reduction in the duration of mechanical ventilation, weaning, and stay in the intensive care unit when standardised weaning protocols are used, but there is significant heterogeneity among studies and an insufficient number of studies to investigate the source of this heterogeneity. Some studies suggest that organisational context could influence outcomes, but this could not be evaluated as it was outside the scope of this review.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract
Background: Automated closed loop systems may improve adaptation of the mechanical support to a patient's ventilatory needs and
facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of
ventilation.

Objectives: To compare the duration of weaning from mechanical ventilation for critically ill ventilated adults and children when managed
with automated closed loop systems versus non-automated strategies. Secondary objectives were to determine differences
in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.

Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2011, Issue 2); MEDLINE (OvidSP) (1948 to August 2011); EMBASE (OvidSP) (1980 to August 2011); CINAHL (EBSCOhost) (1982 to August 2011); and the Latin American and Caribbean Health Sciences Literature (LILACS). In addition we received and reviewed auto-alerts for our search strategy in MEDLINE, EMBASE, and CINAHL up to August 2012. Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles.

Selection criteria: We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning
strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an intensive care unit (ICU).

Data collection and analysis: Two authors independently extracted study data and assessed risk of bias. We combined data into forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria.

Main results: Pooled data from 15 eligible trials (14 adult, one paediatric) totalling 1173 participants (1143 adults, 30 children) indicated that automated closed loop systems reduced the geometric mean duration of weaning by 32% (95% CI 19% to 46%, P =0.002), however heterogeneity was substantial (I2 = 89%, P < 0.00001). Reduced weaning duration was found with mixed or
medical ICU populations (43%, 95% CI 8% to 65%, P = 0.02) and Smartcare/PS™ (31%, 95% CI 7% to 49%, P = 0.02) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (17%, 95% CI 8% to 26%) and ICU length of stay (LOS) (11%, 95% CI 0% to 21%). There was no difference in mortality rates or hospital LOS. Overall the quality of evidence was high with the majority of trials rated as low risk.

Authors' conclusions: Automated closed loop systems may result in reduced duration of weaning, ventilation, and ICU stay. Reductions are more
likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized
controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study reports the use of texture profile analysis (TPA) to mechanically characterize polymeric, pharmaceutical semisolids containing at least one bioadhesive polymer and to determine interactions between formulation components. The hardness, adhesiveness, force per unit time required for compression (compressibility), and elasticity of polymeric, pharmaceutical semisolids containing polycarbophil (1 or 5% w/w), polyvinylpyrrolidone (3 or 5% w/w), and hydroxyethylcellulose (3, 5, or 10% w/w) in phosphate buffer (pH 6.8) were determined using a texture analyzer in the TPA mode (compression depth 15 mm, compression rate 8 mm s(-1) 15 s delay period). Increasing concentrations of polycarbophil, poly vinylpyrrolidone, and hydroxyethylcellulose significantly increased product hardness, adhesiveness, and compressibility but decreased product elasticity. Statistically, interactions between polymeric formulation components were observed within the experimental design and were probably due to relative differences in the physical states of polyvinylpyrrolidone and polycarbophil in the formulations, i.e., dispersed/dissolved and unswollen/swollen, respectively. Increased product hardness and compressibility were possibly due to the effects of hydroxyethylcellulose, polyvinylpyrrolidone, and polycarbophil on the viscosity of the formulations. Increased adhesiveness was related to the concentration and, more importantly, to the physical state of polycarbophil. Decreased product elasticity was due to the increased semisolid nature of the product. TPA is a rapid, straightforward analytical technique that may be applied to the mechanical characterization of polymeric, pharmaceutical semisolids. It provides a convenient means to rapidly identify physicochemical interactions between formulation components. (C) 1996 John Wiley & Sons, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanical fatigue due to environmental loads and spectrum analysis due to launch loads of the primary structure of a low cost, low-earth orbit small satellite intended for earth observation missions are presented. The payload of the satellite under consideration is a precise optical unit to image the earth’s surface having a mass of 45 kg. 3-D Finite Element Model for the satellite structure is generated by applying substructure method. Modal analysis is required to determine natural frequencies of the satellite and define its mode shape. Then, ranking of mode shapes according to specific constraint is performed. Harmonic analysis at resonance frequencies with the highest ranking is done and cumulative fatigue damage analysis is performed. Spectrum analysis is performed for Small Sat structure to verify the satellite structure reliability under all dynamic random vibration loads applied during transportation and launch cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The geometry of tree branches can have considerable effect on their efficiency in terms of carbon export per unit carbon investment in structure. The purpose of this study was to evaluate different design criteria using data describing the form of Picea sitchensis branches. Allometric analysis of the data suggests that resources are distributed to favour shoots with the greatest opportunity for extension into new space, with priority to the extension of the leader. The distribution of allometric relations of links (branch elements) was tested against two models: the pipe model, based on hydraulic transport requirements, and a static load model based on the requirement of shoots to provide mechanical resistance to static loads. Static load resistance required the load parameter to be proportional to the link radius raised to the power of 4. This was shown to be true within a 95% statistical confidence limit. The pipe model would require total distal length to be proportional to link radius squared but the measured branches did not conform well to this model. The comparison suggests that the diameters of branch elements were more related to the requirements for mechanical load. The cost of following a hydraulic design principle (the pipe model) in terms of mechanical efficiency was estimated and suggested that the pipe model branch would not be mechanically compromised but would use structural resources inefficiently. Resource allocation among branch elements was found to be consistent with mechanical stability criteria but also indicated the possibility of allocation based on other criteria, such as potential light interception by shoots. The evidence suggests that whilst branch topology increments by reiteration of units of morphogenesis, the geometry follows a functional design pattern.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent.

OBJECTIVES: To assess the effects of protocolized weaning from mechanical ventilation on the total duration of mechanical ventilation for critically ill adults; ascertain differences between protocolized and non-protocolized weaning in terms of mortality, adverse events, quality of life, weaning duration, intensive care unit (ICU) and hospital length of stay (LOS); and explore variation in outcomes by type of ICU, type of protocol and approach to delivering the protocol.

SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 1, 2010), MEDLINE (1950 to 2010), EMBASE (1988 to 2010), CINAHL (1937 to 2010), LILACS (1982 to 2010), ISI Web of Science and ISI Conference Proceedings (1970 to 2010), Cambridge Scientific Abstracts (inception to 2010) and reference lists of articles. We did not apply language restrictions.

SELECTION CRITERIA: We included randomized and quasi-randomized controlled trials of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults.

DATA COLLECTION AND ANALYSIS: Three authors independently assessed trial quality and extracted data. A priori subgroup and sensitivity analyses were performed. We contacted study authors for additional information.

MAIN RESULTS: Eleven trials that included 1971 patients met the inclusion criteria. The total duration of mechanical ventilation geometric mean in the protocolized weaning group was on average reduced by 25% compared with the usual care group (N = 10 trials, 95% CI 9% to 39%, P = 0.006); weaning duration was reduced by 78% (N = 6 trials, 95% CI 31% to 93%, P = 0.009); and ICU LOS by 10% (N = 8 trials, 95% CI 2% to 19%, P = 0.02). There was significant heterogeneity among studies for total duration of mechanical ventilation (I(2) = 76%, P <0.01) and weaning duration (I(2) = 97%, P <0.01), which could not be explained by subgroup analyses based on type of unit or type of approach.

AUTHORS' CONCLUSIONS: There is some evidence of a reduction in the duration of mechanical ventilation, weaning duration and ICU LOS with use of standardized protocols, but there is significant heterogeneity among studies and an insufficient number of studies to investigate the source of this heterogeneity. Although some study authors suggest that organizational context may influence outcomes, these factors were not considered in all included studies and therefore could not be evaluated.