916 resultados para Lubrication, Rail-Wheel Wear, Rolling Contact Fatigue (RCF), Rail-Wheel Life


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research aimed to analyze the viability of the minimum quantity of lubricant (MQL) technique towards different methods of lubri-refrigeration in surface grinding of steel, considering process quality, wheel life and the viability of using cutting fluids The proposal methods were the conventional (abundant fluid flow), the minimum quantity lubrication (MQL) and the optimized method with Webster nozzle (rounded) This analysis was carried out in equal machining conditions, through the assessment of variables such as grinding force, surface roughness, G ratio (volume of removed material/volume of wheel wear), and microhardness The results showed the possibility of improvement of the grinding process Besides, there is the opportunity for production of high quality workpieces with lower costs The MQL technique showed efficiency in machining with lower depths of cut The optimized method with Webster nozzle applies the fluid in a rational way, without considerable waste Hence, the results show that industry can rationalize and optimize the application of cutting fluids, avoiding inappropriate disposal, inadequate use and consequently environment pollution

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wear and galling are significant issues during production hot stamping processes. This paper uses thermo-mechanical finite element analysis to study the contact pressure, sliding distance and temperature conditions that occur at the wearing interface during hot stamping. Several hot stamping processes are studied, representing the numerous methods that are used in industry to form a typical hat-shaped channel component. These process include crash forming (without blankholder), stamping with a blank holder with an applied blank holder pressure, and stamping with a clearance blank holder (i.e. with spacer blocks). This paper identifies the distinct contact pressure and temperature conditions that occur for each of these forming methods. The regions of the most severe contact conditions are notably different for each of the forming methods. The work from this paper will form the basis for the development of suitable temperature dependent wear models and low cost wear tests for industrial hot stamping applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To investigate the clinical and subjective performance of asmofilcon A, a new third generation silicone hydrogel contact lens during 6-night extended wear (EW) over 6 months. Methods. A prospective, randomized, single-masked study was conducted. Sixty experienced daily wear soft contact lens wearers were randomly assigned to wear either asmofilcon A or senofilcon A contact lenses bilaterally for 6 months on an EW basis. Evaluations were conducted at contact lens delivery and after 1 week, 4 weeks, 3 and 6 months of EW. Results. Fifty subjects (83%) successfully completed the study. Two subjects experienced adverse events; one unilateral red eye with asmofilcon A and one asymptomatic infiltrate with senofilcon A. There were no significant differences in high or low contrast distance visual acuity between asmofilcon A and senofilcon A; however, low contrast distance visual acuity decreased significantly over time with both contact lens types (p < 0.05). The two lens types did not vary significantly with respect to any of the objective and subjective measures assessed (p > 0.05). Superior palpebral conjunctival injection showed a statistically significant increase over time with both lens types (p < 0.05). Both lens types were rated highly with respect to overall comfort, with subjects reporting 14 or 15 h of comfortable lens wearing time per day at each of the study visits (p > 0.05). Overall satisfaction ratings were also very high at all visits, with median scores of 95 (86 to 99) for asmofilcon A and 90 (85 to 96) for senofilcon A at 6 months (p > 0.05). Conclusions. Over 6 months of EW, the asmofilcon A contact lens performed in a similar manner to senofilcon A with respect to visual acuity, ocular health, and contact lens performance measures. Longer-term EW studies are required to investigate the changes over time observed with both lens types.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The European Union has set a target for 10% renewable energy in transport by 2020, which will be met using both biofuels and electric vehicles. In the case of biofuels, for the purposes of meeting the target, the biofuel must achieve greenhouse gas savings of 35% relative to the fossil fuel replaced. For biofuels, greenhouse gas savings can be calculated using life cycle analysis, or the European Union default values. In contrast, all electricity used in transport is considered to be the same, regardless of the source or the type of electric vehicle. However, the choice of the electric vehicle and electricity source will have a major impact on the greenhouse gas savings. This paper examines different electric-vehicle scenarios in terms of greenhouse gas savings, using a well-to-wheel life cycle analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Knowledge on the life span of the riveting dies used in the automotive industry is sparse. It is often the case that only when faulty products are produced are workers aware that their tool needs to be changed. This is of course costly both in terms of time and money. Responding to this challenge, this paper proposes a methodology which integrates wear and stress analysis to quantify the life of a riveting die. Experiments are carried out to measure the applied load required to split a rivet. The obtained results (i.e. force curves) are used to validate the wear mechanisms of the die observed using scanning electron microscopy. Sliding, impact, and adhesive wears are observed on the riveting die after a certain number of riveting cycles. The stress distribution on the die during riveting is simulated using a finite element (FE) approach. In order to confirm the accuracy of the FE model, the experimental force results are compared with the ones produced from FE simulation. The maximum and minimum von Mises' stresses generated from the FE model are input into a Goodman diagram and an S-N curve to compute the life of the riveting die. It is found that the riveting die is predicted to run for 4 980 000 cycles before failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die technischen Oberflächen werden oft als Bauteilversagungsorte definiert. Deswegen ist eine optimale Ausnutzung der Werkstoffeigenschaften ohne mechanische Oberflächenbehandlungsverfahren nicht mehr wegzudenken. Mechanische Randschichtoptimierungsverfahren sind vergleichsweise einfach, Kosten sparend und hocheffektiv. Gerade das Festwalzen wird wegen seiner günstigen Auswirkungen wie die exzellente Oberflächengüte, die hohen Druckeigenspannungen sowie die hohe Oberflächenverfestigung zunehmend an Bedeutung gewinnen. Außerdem wird durch das Festwalzen in einigen Legierungen eine nanokristalline Oberflächenschicht gebildet. Diese brillanten Eigenschaften führen nach einer mechanischen Oberflächenbehandlung zur Erhöhung des Werkstoffwiderstandes unter anderem gegen Verschleiß, Spannungsrisskorrosion und insbesondere zur Steigerung der Schwingfestigkeit. Ein etabliertes Beispiel zur Steigerung der Schwingfestigkeit ist das Festwalzen von Achsen und Kurbelwellen. Auch solche komplexen Komponenten wie Turbinenschaufeln werden zur Schwingfestigkeitssteigerung laserschockverfestigt oder festgewalzt. Die Laserschockverfestigung ist ein relativ neues Verfahren auf dem Gebiet der mechanischen Oberflächenbehandlungen, das z.B. bereits in der Flugturbinenindustrie Anwendung fand und zur Schwingfestigkeitsverbesserung beiträgt. Das Verfahrensprinzip besteht darin, dass ein kurzer Laserimpuls auf die zu verfestigende, mit einer Opferschicht versehene Materialoberfläche fokussiert wird. Das Auftreffen des Laserimpulses auf der verwendeten Opferschicht erzeugt ein expandierendes Plasma, welches eine Schockwelle in randnahen Werkstoffbereichen erzeugt, die elastisch-plastische Verformungen bewirkt. Eine konsekutive Wärmebehandlung, Auslagerung nach dem Festwalzen, nutzt den statischen Reckalterungseffekt. Hierdurch werden die Mikrostrukturen stabilisiert. Die Änderung der Mikrostrukturen kann jedoch zu einer beträchtlichen Abnahme der mittels Festwalzen entstandenen Druckeigenspannungen und der Kaltverfestigungsrate führen. Das Festwalzen bei erhöhter Temperatur bietet eine weitere Möglichkeit die Schwingfestigkeit von metallischen Werkstoffen zu verbessern. Die Mikrostruktur wird durch den Effekt der dynamischen Reckalterung stabilisiert. Die Effekte beim Festwalzen bei erhöhten Temperaturen sind ähnlich dem Warmstrahlen. Das Festwalzen erzeugt Oberflächenschichten mit sehr stabilen Kaltverfestigungen und Druckeigenspannungen. Diese Strukturen haben viele Vorteile im Vergleich zu den durch rein mechanische Verfahren erzeugten Strukturen in Bezug auf die Schwingfestigkeit und die Stabilität der Eigenspannungen. Die Aufgabe der vorliegenden Dissertation war es, Verfahren zur Verbesserung der Schwingfestigkeit im Temperaturbereich zwischen Raumtemperatur und 600 °C zu erforschen. Begleitende mikrostrukturelle sowie röntgenographische Untersuchungen sollen zum Verständnis der Ursachen der Verbesserung beitragen. Für diese Arbeit wurde der in der Praxis häufig verwendete Modellwerkstoff X5CrNi18-10 ausgewählt. Als Randschichtverfestigungsverfahren wurden das Festwalzen, eine Kombination der mechanischen und thermischen, thermomechanischen Verfahren auf der Basis des Festwalzens und eine Laserschockverfestigung verwendet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aims to structurally evaluate a support of graphite pastille for the lubrication of railway wheels. The proper lubrication of wheel flanges of the railway extends the life of this component, so it is very important that this occurs lubrication to reduce the costs involved in railway maintenance. To prepar the evaluation structural will be used to International Electrotechnical Comission standard (IEC 61373) establishing which load cases should be applied to this component. The applied loads on the support (accordance with IEC) are random accelerations and accelerations due to shocks, thus simulating the conditions that exist along the route of the train. The structural analyzes are performed by the finite element method, with the aid of the Cosmos software. Thus, it is possible to determine the stresses acting on the support, and so the allowable stresses compared with the standard proposed by the AISC. The stress in the structural analyzes are lower than allowable therefore considered for the configuration presented, unexpected structural problems

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Fisiopatologia em Clínica Médica - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background The purpose of the present study was to compare dynamic muscle strength, functional performance, fatigue, and quality of life in premenopausal systemic lupus erythematosus (SLE) patients with low disease activity versus matched-healthy controls and to determine the association of dynamic muscle strength with fatigue, functional performance, and quality of life in SLE patients. Methods We evaluated premenopausal (18–45 years) SLE patients with low disease activity (Systemic lupus erythematosus disease activity index [SLEDAI]: mean 1.5 ± 1.2). The control (n = 25) and patient (n = 25) groups were matched by age, physical characteristics, and the level of physical activities in daily life (International Physical Activity Questionnaire IPAQ). Both groups had not participated in regular exercise programs for at least six months prior to the study. Dynamic muscle strength was assessed by one-repetition maximum (1-RM) tests. Functional performance was assessed by the Timed Up and Go (TUG), in 30-s test a chair stand and arm curl using a 2-kg dumbbell and balance test, handgrip strength and a sit-and-reach flexibility test. Quality of life (SF-36) and fatigue were also measured. Results The SLE patients showed significantly lower dynamic muscle strength in all exercises (leg press 25.63%, leg extension 11.19%, leg curl 15.71%, chest press 18.33%, lat pulldown 13.56%, 1-RM total load 18.12%, P < 0.001-0.02) compared to the controls. The SLE patients also had lower functional performance, greater fatigue and poorer quality of life. In addition, fatigue, SF-36 and functional performance accounted for 52% of the variance in dynamic muscle strength in the SLE patients. Conclusions Premenopausal SLE patients with low disease activity showed lower dynamic muscle strength, along with increased fatigue, reduced functional performance, and poorer quality of life when compared to matched controls.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The year so far has been a slow start for many businesses, but at least we have not seen the collapse of as many businesses that we were seeing around two years ago. We are, however, still well and truly in the midst of a global recession. Interest rates are still at an all time low, UK house prices seem to be showing little signs of increase (except in London where everyone still seems to want to live!) and for the ardent shopper there are bargains to be had everywhere. It seems strange that prices on the high street do not seem to have increased in over ten years. Mobile phones, DVD players even furniture seems to be cheaper than they used to be. Whist much of this is down to cheaper manufacturing and the rest could probably be explained by competition within the market place. Does this mean that quality suffered too? Now that we live in a world when if a television is not working it is thrown away and replaced. There was a time when you would take it to some odd looking man that your father would know who could fix it for you. (I remember our local television fix-it man, with his thick rimmed bifocal spectacles and a poor comb-over; he had cardboard boxes full of resistors and electrical wires on the floor of his front room that smelt of soldering irons!) Is this consumerism at an extreme or has this move to disposability made us a better society? Before you think these are just ramblings there is a point to this. According to latest global figures of contact lens sales the vast majority of contact lenses fitted around the world are daily, fortnightly or monthly disposable hydrogel lenses. Certainly in the UK over 90% of lenses are disposable (with daily disposables being the most popular, having a market share of over 50%). This begs the question – is this a good thing? Maybe more importantly, do our patients benefit? I think it is worth reminding ourselves why we went down the disposability route with contact lenses in the first place, and unlike electrical goods it was not just so we did not have to take them for repair! There are the obvious advantages of overcoming problems of breakage and tearing of lenses and the lens deterioration with age. The lenses are less likely to be contaminated and the disinfection is either easier or not required at all (in the case of daily disposable lenses). Probably the landmark paper in the field was the work more commonly known as the ‘Gothenburg Study’. The paper, entitled ‘Strategies for minimizing the Ocular Effects of Extended Contact Lens Wear’ published in the American Journal of Optometry in 1987 (volume 64, pages 781-789) by Holden, B.A., Swarbrick, H.A., Sweeney, D.F., Ho, A., Efron, N., Vannas, A., Nilsson, K.T. They suggested that contact lens induced ocular effects were minimised by: •More frequently removed contact lenses •More regularly replaced contact lenses •A lens that was more mobile on the eye (to allow better removal of debris) •Better flow of oxygen through the lens All of these issues seem to be solved with disposability, except the oxygen issue which has been solved with the advent of silicone hydrogel materials. Newer issues have arisen and most can be solved in practice by the eye care practitioner. The emphasis now seems to be on making lenses more comfortable. The problems of contact lens related dry eyes symptoms seem to be ever present and maybe this would explain why in the UK we have a pretty constant contact lens wearing population of just over three million but every year we have over a million dropouts! That means we must be attracting a million new wearers every year (well done to the marketing departments!) but we are also losing a million wearers every year. We certainly are not losing them all to the refractive surgery clinics. We know that almost anyone can now wear a contact lens and we know that some lenses will solve problems of sharper vision, some will aid comfort, and some will be useful for patients with dry eyes. So if we still have so many dropouts then we must be doing something wrong! I think the take home message has to be ‘must try harder’! I must end with an apology for two errors in my editorial of issue 1 earlier this year. Firstly there was a typo in the first sentence; I meant to state that it was 40 years not 30 years since the first commercial soft lens was available in the UK. The second error was one that I was unaware of until colleagues Geoff Wilson (Birmingham, UK) and Tim Bowden (London, UK) wrote to me to explain that soft lenses were actually available in the UK before 1971 (please see their ‘Letters to the Editor’ in this issue). I am grateful to both of them for correcting the mistake.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Colorectal cancer survivors may suffer from a range of ongoing psychosocial and physical problems that negatively impact on quality of life. This paper presents the study protocol for a novel telephone-delivered intervention to improve lifestyle factors and health outcomes for colorectal cancer survivors. Methods/Design Approximately 350 recently diagnosed colorectal cancer survivors will be recruited through the Queensland Cancer Registry and randomised to the intervention or control condition. The intervention focuses on symptom management, lifestyle and psychosocial support to assist participants to make improvements in lifestyle factors (physical activity, healthy diet, weight management, and smoking cessation) and health outcomes. Participants will receive up to 11 telephone-delivered sessions over a 6 month period from a qualified health professional or 'health coach'. Data collection will occur at baseline (Time 1), post-intervention or six months follow-up (Time 2), and at 12 months follow-up for longer term effects (Time 3). Primary outcome measures will include physical activity, cancer-related fatigue and quality of life. A cost-effective analysis of the costs and outcomes for survivors in the intervention and control conditions will be conducted from the perspective of health care costs to the government. Discussion The study will provide valuable information about an innovative intervention to improve lifestyle factors and health outcomes for colorectal cancer survivors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Colorectal cancer (CRC) diagnosis and the ensuing treatments can have a substantial impact on the physical and psychological health of survivors. As the number of CRC survivors increases, so too does the need to develop viable rehabilitation programs to help these survivors return to good health as quickly as possible. Exercise has the potential to address many of the adverse effects of CRC treatment; however, to date, the role of exercise in the rehabilitation of cancer patients immediately after the completion of treatment has received limited research attention. This paper presents the design of a randomised controlled trial which will evaluate the feasibility and efficacy of a 12-week supervised aerobic exercise program (ImPACT Program) on the physiological and psychological markers of rehabilitation, in addition to biomarkers of standard haematological outcomes and the IGF axis. Methods/Design Forty CRC patients will be recruited through oncology clinics and randomised to an exercise group or a usual care control group. Baseline assessment will take place within 4 weeks of the patient completing adjuvant chemotherapy treatment. The exercise program for patients in the intervention group will commence a week after the baseline assessment. The program consists of three supervised moderate-intensity aerobic exercise sessions per week for 12 weeks. All participants will have assessments at baseline (0 wks), mid-intervention (6 wks), post-intervention (12 wks) and at a 6-week follow-up (18 wks). Outcome measures include cardio-respiratory fitness, biomarkers associated with health and survival, and indices of fatigue and quality of life. Process measures are participants' acceptability of, adherence to, and compliance with the exercise program, in addition to the safety of the program. Discussion The results of this study will provide valuable insight into the role of supervised exercise in improving life after CRC. Additionally, process analyses will inform the feasibility of implementing the program in a population of CRC patients immediately after completing chemotherapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article proposes a model to predict uniaxial and multiaxial ratcheting life by addressing the three primary parameters that influence failure life: fatigue damage, ratcheting damage and the multiaxial loading path. These three factors are addressed in the present model by (a) the stress amplitude for fatigue damage, (b) mean stress-dependent Goodman equation for ratcheting damage and (c) an inherent weight factor based on average equivalent stress to account for the multiaxial loading. The proposed model requires only two material constants which can be easily determined from uniaxial symmetric stress-controlled fatigue tests. Experimental ratcheting life data collected from the literature for 1025 and 42CrMo steel under multiaxial proportional and nonproportional constant amplitude loading ratcheting with triangular sinusoidal and trapezoidal waveform (i.e. linear, rhombic, circular, elliptical and square stress paths) have shown good agreement with the proposed model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)