146 resultados para Ligaments
Resumo:
Controlled breakup of droplets using heat or acoustics is pivotal in applications such as pharmaceutics, nanoparticle production, and combustion. In the current work we have identified distinct thermal acoustics-induced deformation regimes (ligaments and bubbles) and breakup dynamics in externally heated acoustically levitated bicomponent (benzene-dodecane) droplets with a wide variation in volatility of the two components (benzene is significantly more volatile than dodecane). We showcase the physical mechanism and universal behavior of droplet surface caving in leading to the inception and growth of ligaments. The caving of the top surface is governed by a balance between the acoustic pressure field and the restrictive surface tension of the droplet. The universal collapse of caving profiles for different benzene concentration (<70% by volume) is shown by using an appropriate time scale obtained from force balance. Continuous caving leads to the formation of a liquid membrane-type structure which undergoes radial extension due to inertia gained during the precursor phase. The membrane subsequently closes at the rim and the kinetic energy leads to ligament formation and growth. Subsequent ligament breakup is primarily Rayleigh-Plateau type. The breakup mode shifts to diffusional entrapment-induced boiling with an increase in concentration of the volatile component (benzene >70% by volume). The findings are portable to any similar bicomponent systems with differential volatility.
Resumo:
O prolapso uterino tem sua incidência aumentada na pós-menopausa. O objetivo deste estudo é identificar as alterações na matriz extracelular do ligamento cardinal associadas à menopausa e ao prolapso uterino. Ligamento cardinal de três diferentes grupos de mulheres, pré-menopausa, prolapso uterino e pós-menopausa, foram identificados e biopsiados durante 57 histerectomias abdominais ou vaginais. As amostras foram processadas por métodos bioquímicos para caracterização e quantificação de glicosaminoglicanos sulfatados e colágeno. As concentrações relativas de glicosaminoglicanos foram obtidas por eletroforese. Procedimentos histológicos foram feitos para identificar fibras elásticas (Weigert), distribuição de colágeno (Picro Sirius) e decorin (imunohistoquímica). Nossos resultados mostraram aumento na concentração de GAG de 72,2%, redução na concentração de colágeno de 37% e diminuição de 22% de fibras elásticas no grupo de prolapso uterino quando comparado ao grupo da pós-menopausa (p<0,05, p<0,04 e p<0,05 respectivamente). As concentrações relativas de glicosaminoglicanos sulfatados para condroitin sulfato, heparan sulfato e dermatan sulfato não mostraram diferenças entre os três grupos. A organização do colágeno foi similar entre os três grupos e a marcação do decorin pareceu estar diminuída no grupo de prolapso uterino. Nossos resultados indicam alterações no metabolismo do tecido conjuntivo. O ligamento cardinal da mulher na pós-menopausa possui uma matriz extracelular mais densa. Esta alteração não ocorre na mulher com prolapso uterino.
Resumo:
High speed photographic images of jets formed from dilute solutions of polystyrene in diethyl phthalate ejected from a piezoelectric drop-on-demand inkjet head have been analyzed in order to study the formation and distribution of drops as the ligament collapses. Particular attention has been paid to satellite drops, and their relative separation and sizes. The effect of polymer concentration was investigated. The distribution of nearest-neighbour centre spacing between the drops formed from the ligament is better described by a 2-parameter modified gamma distribution than by a Gaussian distribution. There are (at least) two different populations of satellite size relative to the main drop size formed at normal jetting velocities, with ratios of about three between the diameters of the main drop and the successive satellite sizes. The distribution of the differences in drop size between neighbouring drops is close to Gaussian, with a small non-zero mean for low polymer concentrations, which is associated with the conical shape of the ligament prior to its collapse and the formation of satellites. Higher polymer concentrations result in slower jets for the same driving impulse, and also a tendency to form ligaments with a near-constant width. Under these conditions the mean of the distribution of differences in nearest-neighbour drop size was zero.
Resumo:
A previous 1-D model for the shortening of an unbroken drop-on-demand ink-jet ligament has been extended to the case of an arbitrary attached tail mass, and can also include extensional viscosity (which has ∼ 2% effect) as well as linear elasticity in the fluid. Predictions from the improved model are shown to be very similar to results from 2-D axisymmetric numerical simulations of DoD ink-jet ligaments and also to the results of recent experiments on Newtonian fluids jetted without satellite formation.
Resumo:
The final stages of pinchoff and breakup of dripping droplets of near-inviscid Newtonian fluids are studied experimentally for pure water and ethanol. High-speed imaging and image analysis are used to determine the angle and the minimum neck size of the cone-shaped extrema of the ligaments attached to dripping droplets in the final microseconds before pinchoff. The angle is shown to steadily approach the value of 18.0 ±0.4, independently of the initial flow conditions or the type of breakup. The filament thins and necks following a τ2 /3 law in terms of the time remaining until pinchoff, regardless of the initial conditions. The observed behavior confirms theoretical predictions. © 2012 American Physical Society.
Resumo:
The final stages of pinchoff and breakup of dripping droplets of near-inviscid Newtonian fluids are studied experimentally for pure water and ethanol. High-speed imaging and image analysis are used to determine the angle and the minimum neck size of the cone-shaped extrema of the ligaments attached to dripping droplets in the final microseconds before pinchoff. The angle is shown to steadily approach the value of 18.0 ± 0.4°, independently of the initial flow conditions or the type of breakup. The filament thins and necks following a τ(2/3) law in terms of the time remaining until pinchoff, regardless of the initial conditions. The observed behavior confirms theoretical predictions.
Resumo:
The graft copolymer of high impact polystyrene (HIPS) grafted with malice anhydride (MA) (HIPS-g-MA) was prepared with melt mixing in the presence of a free-radical initiator. The grafting reaction was confirmed by IR analyses and the amount of MA grafted on HIPS was evaluated by a titration method. 1-5 wt% of MA can be grafted on HIPS. HIPS-g-MA is miscible with HIPS. Its anhydride group can react with the PA6 during melt mixing the two components. The compatibility of HIPS-g-MA in the HIPS/PA6 blends was evident. Evidence of reactions in the blends was confirmed in the morphology and mechanical properties of the blends. A significant reduction in domain size was observed because of the compatibilization of HIPS-g-MA in the blends of HIPS and PA6. The tensile mechanical properties of the prepared blends were investigated and the fracture surfaces of the blends were examined by means of the scanning electron microscope (SEM). The improved adhesion in a 16%HIPS/75%PA6 blend with 9%HIPS-g-MA copolymer was detected. The morphology of fibrillar ligaments formed by PA6 connecting HIPS particles was observed.
Resumo:
Initiation and termination of crazes in high impact polystyrene (HIPS) were studied by transmission electron microscope. Instead of the first initiation of crazes in the vicinity of the equator or rubber particles, ribbon-shaped crazes beyond the region were observed on the TEM photos. The starting point and the end point of each ribbon were noticed not to be randomly located on the surface of the cellar particles in HIPS. The spots connecting to the ligaments between the PS rigid inclusions in the cellar particle are found to be the locations where crazes were initiated and terminated preferentially. In addition, the crazes generated at those spots were much thicker and longer. The thoughness of high impact polystyrene was enhanced by the multiple crazes formed in the matrices, through the reduction of the craze stress at room temperature with increasing the volume fraction of polybutadiene at these spots in the dispersed phase. These results conducted that not only the cell structure of the domains in HIPS was not homogeneous but also the polybutadiene ligaments between PS rigid inclusions in the domains were inhomogeneous. Therefore, the responsibility of those polybutadiene ligaments with different thickness to the stresses was different and it forced the crazing initiation and growing preferentially. The crazes were created in some regions in the matrices; On the contrary, rare crazes were formed in the other regions in spite of these regions surrounded around the same dispersed particles. The relation between the spots on the surface and the inner structure of the cellar particle was discussed in this paper.
Resumo:
The graft copolymer of high-impact polystyrene (HIPS) grafted with maleic anhydride (MA) (HIPS-g-MA) was prepared with melt mixing in the presence of a free-radical initiator. The grafting reaction was confirmed by infrared analyses, and the amount of MA grafted on HIPS was evaluated by a titration method. 1-5% of MA can be grafted on HIPS. HIPS-g-MA is miscible with HIPS. Its anhydride group can react with polyamide 1010 (PA1010) during melt mixing of the two components. The compatibility of HIPS-g-MA. in the HIPS/PA1010 blends was evident. Evidence of reactions in the blends was confirmed in the morphology and mechanical behavior of the blends. A significant reduction in domain size was observed because of the compatibilization of HIPS-g-MA in the blends of HIPS and PA1010. The tensile mechanical properties of the prepared blends were investigated, and the fracture surfaces of the blends were examined by means of the scanning electron microscope. The improved adhesion in a 15% HIPS/75% PA1010 blend with 10% HIPS-g-MA copolymer was detected. The morphology of fibrillar ligaments formed by PA1010 connecting HIPS particles was observed. (C) 1999 John Wiley & Sons, Inc.
Resumo:
Trabalho apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária
Resumo:
Human adipose stem cells (hASCs) can differentiate into a variety of phenotypes. Native extracellular matrix (e.g., demineralized bone matrix or small intestinal submucosa) can influence the growth and differentiation of stem cells. The hypothesis of this study was that a novel ligament-derived matrix (LDM) would enhance expression of a ligamentous phenotype in hASCs compared to collagen gel alone. LDM prepared using phosphate-buffered saline or 0.1% peracetic acid was mixed with collagen gel (COL) and was evaluated for its ability to induce proliferation, differentiation, and extracellular matrix synthesis in hASCs over 28 days in culture at different seeding densities (0, 0.25 x 10(6), 1 x 10(6), or 2 x 10(6) hASC/mL). Biochemical and gene expression data were analyzed using analysis of variance. Fisher's least significant difference test was used to determine differences between treatments following analysis of variance. hASCs in either LDM or COL demonstrated changes in gene expression consistent with ligament development. hASCs cultured with LDM demonstrated more dsDNA content, sulfated-glycosaminoglycan accumulation, and type I and III collagen synthesis, and released more sulfated-glycosaminoglycan and collagen into the medium compared to hASCs in COL (p
Resumo:
In podiatric clinics is very common to find inflamatory process in metatarsophalangeal joint capsule , plantar plate and collateral ligaments damage, but it is not clearly recognized. Many authors hipotetized with joint instability of multiple aetiology and his concomitant evolution in different stages with own joint disease. This pathology has more incidence in second metatarsophalangeal joint than third and others and it is a common etiology of metatarsal pain. Bad biomechanics alters forefoot function and can produce overload in capsular joint, decreasing mobility and getting worse the pathology.
Resumo:
I undertook the 2012 ECOSEP travelling fellowship, sponsored by Bauerfeind, between May and August 2012, which involved visiting 5 European sport medicine centres and spending approximately one week in each centre. The 5 centres included: National Track and Field Centre, SEGAS, Thessaloniki, Greece; Professional School in Sport & Exercise Medicine, University of Barcelona, Spain; Sport Medicine Frankfurt Institute, Germany; Isokinetic Medical Group, FIFA Medical Centre of Excellence, Bologna, Italy, and Centre for Sports and Exercise Medicine, Barts and the London School of Medicine and Dentistry, Mile End Hospital, England. Throughout the fellowship, the clinical cases which were routinely encountered were documented. The following sections detail my experiences throughout the fellowship, the sports of the athletes and the injuries which were treated at each of the sport medicine centres during the fellowship visit and the different forms of management employed. © 2012, CIC Edizioni Internazionali
Resumo:
O presente trabalho teve como objetivo principal estudar o comportamento mecânico do disco intervertebral recorrendo a sensores em fibra ótica. Na expetativa de efetuar o melhor enquadramento do tema foi efetuada uma revisão exaustiva das várias configurações de sensores em fibra ótica que têm vindo a ser utilizadas em aplicações biomédicas e biomecânicas, nomeadamente para medição de temperatura, deformação, força e pressão. Nesse âmbito, procurou-se destacar as potencialidades dos sensores em fibra ótica e apresentá-los como uma tecnologia alternativa ou até de substituição das tecnologias associadas a sensores convencionais. Tendo em vista a aplicação de sensores em fibra ótica no estudo do comportamento do disco intervertebral efetuou-se também uma revisão exaustiva da coluna vertebral e, particularmente, do conceito de unidade funcional. A par de uma descrição anatómica e funcional centrada no disco intervertebral, vértebras adjacentes e ligamentos espinais foram ainda destacadas as suas propriedades mecânicas e descritos os procedimentos mais usuais no estudo dessas propriedades. A componente experimental do presente trabalho descreve um conjunto de experiências efetuadas com unidades funcionais cadavéricas utilizando sensores convencionais e sensores em fibra ótica com vista à medição da deformação do disco intervertebral sob cargas compressivas uniaxiais. Inclui ainda a medição in vivo da pressão intradiscal num disco lombar de uma ovelha sob efeito de anestesia. Para esse efeito utilizou-se um sensor comercial em fibra ótica e desenvolveu-se a respetiva unidade de interrogação. Finalmente apresenta-se os resultados da investigação em curso que tem como objetivo propor e desenvolver protótipos de sensores em fibra ótica para aplicações biomédicas e biomecânicas. Nesse sentido, são apresentadas duas soluções de sensores interferométricos para medição da pressão em fluídos corporais.
Resumo:
Les approches arthroscopiques et l’anatomie normale des articulations antébrachiocarpienne, carpienne moyenne et tarsocrurale n’ont jamais été décrites spécifiquement chez les bovins. Notre étude avait pour buts de définir les abords chirurgicaux et de décrire l’anatomie arthroscopique de ces trois articulations. Deux carpes et deux tarses issus du cadavre frais d’une vache adulte ont été injectés avec un mélange de latex, puis disséqués afin de déterminer les sites arthroscopiques d’intérêt. Par la suite, l’arthroscopie des articulations antébrachiocarpienne et carpienne moyenne (approche dorsale) et de l’articulation tarsocrurale (approches dorsale et plantaire) a été réalisée sur six cadavres frais de vaches adultes ne présentant ni boiterie ni distension articulaire avant leur euthanasie. Les approches dorsolatérale et dorsomédiale des articulations antébrachiocarpienne et carpienne moyenne ont été réalisées de part et d’autre de l’extenseur radial du carpe. Les structures observées étaient le radius distal, les os radial, intermédiaire, ulnaire, II et III fusionnés et IV du carpe, ainsi que des ligaments palmaires. Les approches dorsolatérale et dorsomédiale de l’articulation tarsocrurale ont été réalisées latéralement au long extenseur des doigts et médialement au troisième péronier respectivement. Les approches plantarolatérale et plantaromédiale ont été réalisées latéralement au fléchisseur latéral des doigts et latéralement au fléchisseur médial des doigts respectivement. Les structures observées étaient le tibia distal, les trochlées proximale et plantaire du talus, le processus coracoïde du calcanéus, l’articulation fibulo-calcanéenne et des ligaments articulaires. Quelle que soit l’articulation, l’approche latérale était préférée à l’approche médiale. L’arthroscopie du carpe et du tarse pourra être proposée dans un contexte hospitalier comme outil diagnostique, thérapeutique et pronostique des maladies articulaires bovines.