997 resultados para LIQUID NORMAL-ALKANES
Resumo:
A filamentary model of “metallic” conduction in layered high temperature superconductive cuprates explains the concurrence of normal state resistivities (Hall mobilities) linear in T (T−2) with optimized superconductivity. The model predicts the lowest temperature T0 for which linearity holds and it also predicts the maximum superconductive transition temperature Tc. The theory abandons the effective medium approximation that includes Fermi liquid as well as all other nonpercolative models in favor of countable smart basis states.
Resumo:
Fluid and macromolecule secretion by submucosal glands in mammalian airways is believed to be important in normal airway physiology and in the pathophysiology of cystic fibrosis (CF). An in situ fluorescence method was applied to measure the ionic composition and viscosity of freshly secreted fluid from airway glands. Fragments of human large airways obtained at the time of lung transplantation were mounted in a humidified perfusion chamber and the mucosal surface was covered by a thin layer of oil. Individual droplets of secreted fluid were microinjected with fluorescent indicators for measurement of [Na+], [Cl−], and pH by ratio imaging fluorescence microscopy and viscosity by fluorescence recovery after photobleaching. After carbachol stimulation, 0.1–0.5 μl of fluid accumulated in spherical droplets at gland orifices in ≈3–5 min. In gland fluid from normal human airways, [Na+] was 94 ± 8 mM, [Cl−] was 92 ± 12 mM, and pH was 6.97 ± 0.06 (SE, n = 7 humans, more than five glands studied per sample). Apparent fluid viscosity was 2.7 ± 0.3-fold greater than that of saline. Neither [Na+] nor pH differed in gland fluid from CF airways, but viscosity was significantly elevated by ≈2-fold compared to normal airways. These results represent the first direct measurements of ionic composition and viscosity in uncontaminated human gland secretions and indicate similar [Na+], [Cl−], and pH to that in the airway surface liquid. The elevated gland fluid viscosity in CF may be an important factor promoting bacterial colonization and airway disease.
Resumo:
The retinoblastoma (RB) gene specifies a nuclear phosphoprotein (pRb 105), which is a prototype tumor suppressor inactivated in a variety of human tumors. Recent studies suggest that RB is also involved in embryonic development of murine central nervous and hematopoietic systems. We have investigated RB expression and function in human adult hematopoiesis--i.e., in liquid suspension culture of purified quiescent hematopoietic progenitor cells (HPCs) induced by growth factor stimulus to proliferation and unilinage differentiation/maturation through the erythroid or granulocytic lineage. In the initial HPC differentiation stages, the RB gene is gradually induced at the mRNA and protein level in both erythroid and granulopoietic cultures. In late HPC differentiation and then precursor maturation, RB gene expression is sustained in the erythroid lineage, whereas it is sharply downmodulated in the granulocytic series. Functional studies were performed by treatment of HPC differentiation culture with phosphorothioate antisense oligomer targeting Rb mRNA; coherent with the expression pattern, oligomer treatment of late HPCs causes a dose-dependent and selective inhibition of erythroid colony formation. These observations suggest that the RB gene plays an erythroid- and stage-specific functional role in normal adult hematopoiesis, particularly at the level of late erythroid HPCs.
Resumo:
Quaternary ammonium-functionalized silica materials were synthesized and applied for solid-phase extraction (SPE) of aromatic amines, which are classified as priority pollutants by US Environmental Protection Agency. Hexamethylenetetramine used for silica surface modification for the first time was employed as SPE sorbent under normal phase conditions. Hexaminium-functionalized silica demonstrated excellent extraction efficiencies for o-toluidine, 4-ethylaniline and quinoline (recoveries 101–107%), while for N,N-dimethylaniline and N-isopropylaniline recoveries were from low to moderate (14–46%). In addition, the suitability of 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica as SPE sorbent was tested under normal phase conditions. The recoveries achieved for the five aromatic amines ranged from 89 to 99%. The stability of the sorbent was evaluated during and after 150 extractions. Coefficients of variation between 4.5 and 10.2% proved a high stability of the synthesized sorbent. Elution was carried out using acetonitrile in the case of hexaminium-functionalized silica and water for 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica sorbent. After the extraction the analytes were separated and detected by liquid chromatography ultraviolet detection (LC-UV). The retention mechanism of the materials was primarily based on polar hydrogen bonding and π–π interactions. Comparison made with activated silica proved the quaternary ammonium-functionalized materials to offer different selectivity and better extraction efficiencies for aromatic amines. Finally, 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica sorbent was successfully tested for the extraction of wastewater and soil samples.
Resumo:
A novel approach is presented to determine mercury in urine samples, employing vortex-assisted ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction to prepare samples, and screen-printed electrodes modified with gold nanoparticles for voltammetric analysis. Mercury was extracted directly from non-digested urine samples in a water-immiscible ionic liquid, being back-extracted into an acidic aqueous solution. Subsequently, it was determined using gold nanoparticle-modified screen-printed electrodes. Under optimized microextraction conditions, standard addition calibration was applied to urine samples containing 5, 10 and 15 μg L−1 of mercury. Standard addition calibration curves using standards between 0 and 20 μg L−1 gave a high level of linearity with correlation coefficients ranging from 0.990 to 0.999 (N = 5). The limit of detection was empirical and statistically evaluated, obtaining values that ranged from 0.5 to 1.5 μg L−1, and from 1.1 to 1.3 μg L−1, respectively, which are significantly lower than the threshold level established by the World Health Organization for normal mercury content in urine (i.e., 10–20 μg L−1). A certified reference material (REC-8848/Level II) was analyzed to assess method accuracy finding 87% and 3 μg L−1 as the recovery (trueness) and standard deviation values, respectively. Finally, the method was used to analyze spiked urine samples, obtaining good agreement between spiked and found concentrations (recovery ranged from 97 to 100%).
Resumo:
In this paper we investigate the difference between the adsorption of spherical molecule argon (at 87.3 K) and the flexible normal butane (at an equivalent temperature of 150 K) in carbon slit pores. These temperatures are equivalent in the sense that they have the same relative distances between their respective triple points and critical points. Higher equivalent temperatures are also studied (122.67 K for argon and 303 K for n-butane) to investigate the effects of temperature on the 2D-transition in adsorbed density. The Grand Canonical Monte Carlo simulation is used to study the adsorption of these two model adsorbates. Beside the longer computation times involved in the computation of n-butane adsorption, n-butane exhibits many interesting behaviors such as: (i) the onset of adsorption occurs sooner (in terms of relative pressure), (ii) the hysteresis for 2D- and 3D-transitions is larger, (iii) liquid-solid transition is not possible, (iv) 2D-transition occurs for n-butane at 150 K while it does not happen for argon except for pores that accommodate two layers of molecules, (v) the maximum pore density is about four times less than that of argon and (vi) the sieving pore width is slightly larger than that for argon. Finally another feature obtained from the Grand Canonical Monte Carlo (GCMC) simulation is the configurational arrangement of molecules in pores. For spherical argon, the arrangement is rather well structured, while for n-butane the arrangement depends very much on the pore size. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The in situ real time measurement of the regression rate of a melting interface (RRMI) is performed by the ultrasonic measurement system reported here. The RRMI is the rate at which a solid/liquid interface (SLI) moves along a metallic rod while burning in an oxygen-enriched atmosphere and is an important flatnmability indicator. The ultrasonic transducer and associated equipment used to drive the transducer and record the echo signal is described, along with the process that transforms the acquired signals into a RRMI value. Test rods of various metals and geometric shapes were burned at several test conditions in different test facilities. The RRMI results with quantified errors are presented and reviewed. The effect of reduced gravity on burning metals is important to space-applications and RRMI results obtained in a reduced gravity environment are also presented.
Resumo:
A study has been undertaken of the vapor-phase adsorptive separation of n-alkanes from Kuwait kerosene (Kuwait National Petroleum Company, heavy kerosene) using zeolite molecular sieves. Due to the shortage of information on the adsorption of multicomponent systems in the open literature, the present investigation was initiated to study the effect of feed flowrate, temperature, and zeolite particle size on the height of mass transfer zone (MTZ) and the dynamic capacity of the adsorbent for multicomponent n-alkanes adsorption on a fixed-bed of zeolite type-5A. The optimum operating conditions for separation of the n-alkanes has been identified so that the effluent would also be of marketable quality. The effect of multicycle adsorption-desorption stages on the dynamic behaviour of zeolite using steam as a desorbing agent has been studied and compared with n-pentane and n-hexane as desorbing agents. The separation process comprised one cycle of adsorption using a fixed-bed of zeolite type-5A. The bed was fed with vaporized kerosene until saturation had been achieved whereby the n-alkanes were adsorbed and the denormalized material eluted. The process of adsorption-desorption was carried out isobarically at one atmosphere. A mathematical model has been developed to predict the breakthrough time using the method of characteristics. The results were in a reasonable agreement with the experimental values. This model has also been utilized to develop the equilibrium isotherm. Optimum operating conditions were achieved at a feed flowrate of 33.33 x 10-9 m3/s, a temperature of 643 K, and a particle size of (1.0 - 2.0) x 10-3 m. This yielded an HMTZ value and a dynamic capacity of 0.206 m and 9.6S3 x 10-2 kg n-alkanes/kg of zeolite respectively. These data will serve as a basis for design of a commercial plant. The purity of liquid-paraffin product desorbed using steam was 83.24 wt%. The dynamic capacity was noticed to decrease sharply with the cycle number, without intermediate reactivation of zeolite, while it was kept unchanged by intermediate reactivation. Normal hexane was found to be the best desorbing agent, the efficiency of which was mounted to 88.2%.
Resumo:
A study of the hydrodynamics and mass transfer characteristics of a liquid-liquid extraction process in a 450 mm diameter, 4.30 m high Rotating Disc Contactor (R.D.C.) has been undertaken. The literature relating to this type of extractor and the relevant phenomena, such as droplet break-up and coalescence, drop mass transfer and axial mixing has been revjewed. Experiments were performed using the system C1airsol-350-acetone-water and the effects of drop size, drop size-distribution and dispersed phase hold-up on the performance of the R.D.C. established. The results obtained for the two-phase system C1airso1-water have been compared with published correlations: since most of these correlations are based on data obtained from laboratory scale R.D.C.'s, a wide divergence was found. The hydrodynamics data from this study have therefore been correlated to predict the drop size and the dispersed phase hold-up and agreement has been obtained with the experimental data to within +8% for the drop size and +9% for the dispersed phase hold-up. The correlations obtained were modified to include terms involving column dimensions and the data have been correlated with the results obtained from this study together with published data; agreement was generally within +17% for drop size and within +14% for the dispersed phase hold-up. The experimental drop size distributions obtained were in excellent agreement with the upper limit log-normal distributions which should therefore be used in preference to other distribution functions. In the calculation of the overall experimental mass transfer coefficient the mean driving force was determined from the concentration profile along the column using Simpson's Rule and a novel method was developed to calculate the overall theoretical mass transfer coefficient Kca1, involving the drop size distribution diagram to determine the volume percentage of stagnant, circulating and oscillating drops in the sample population. Individual mass transfer coefficients were determined for the corresponding droplet state using different single drop mass transfer models. Kca1 was then calculated as the fractional sum of these individual coefficients and their proportions in the drop sample population. Very good agreement was found between the experimental and theoretical overall mass transfer coefficients. Drop sizes under mass transfer conditions were strongly dependant upon the direction of mass transfer. Drop Sizes in the absence of mass transfer were generally larger than those with solute transfer from the continuous to the dispersed phase, but smaller than those with solute transfer in the opposite direction at corresponding phase flowrates and rotor speed. Under similar operating conditions hold-up was also affected by mass transfer; it was higher when solute transfered from the continuous to the dispersed phase and lower when direction was reversed compared with non-mass transfer operation.
Resumo:
As a basis for the commercial separation of normal paraffins a detailed study has been made of factors affecting the adsorption of binary liquid mixtures of high molecular weight normal paraffins (C12, C16, and C20) from isooctane on type 5A molecular sieves. The literature relating to molecular sieve properties and applications, and to liquid-phase adsorption of high molecular weight normal paraffin compounds by zeolites, was reviewed. Equilibrium isotherms were determined experimentally for the normal paraffins under investigation at temperatures of 303oK, 323oK and 343oK and showed a non-linear, favourable- type of isotherm. A higher equilibrium amount was adsorbed with lower molecular weight normal paraffins. An increase in adsorption temperature resulted in a decrease in the adsorption value. Kinetics of adsorption were investigated for the three normal paraffins at different temperatures. The effective diffusivity and the rate of adsorption of each normal paraffin increased with an increase in temperature in the range 303 to 343oK. The value of activation energy was between 2 and 4 kcal/mole. The dynamic properties of the three systems were investigated over a range of operating conditions (i.e. temperature, flow rate, feed concentration, and molecular sieve size in the range 0.032 x 10-3 to 2 x 10-3m) with a packed column. The heights of adsorption zones calculated by two independent equations (one based on a constant width, constant velocity and adsorption zone and the second on a solute material balance within the adsorption zone) agreed within 3% which confirmed the validity of using the mass transfer zone concept to provide a simple design procedure for the systems under study. The dynamic capacity of type 5A sieves for n-eicosane was lower than for n-hexadecane and n-dodecane corresponding to a lower equilibrium loading capacity and lower overall mass transfer coefficient. The values of individual external, internal, theoretical and experimental overall mass transfer coefficient were determined. The internal resistance was in all cases rate-controlling. A mathematical model for the prediction of dynamic breakthrough curves was developed analytically and solved from the equilibrium isotherm and the mass transfer rate equation. The experimental breakthrough curves were tested against both the proposed model and a graphical method developed by Treybal. The model produced the best fit with mean relative percent deviations of 26, 22, and 13% for the n-dodecane, n-hexadecane, and n-eicosane systems respectively.
Resumo:
A total pressure apparatus has been developed to measure vapour-liquid equilibrium data on binary mixtures at atmospheric and sub-atmospheric pressures. The method gives isothermal data which can be obtained rapidly. Only measurements of total pressure are made as a direct function of composition of synthetic liquid phase composition, the vapour phase composition being deduced through the Gibbs-Duhem relationship. The need to analyse either of the phases is eliminated. As such the errors introduced by sampling and analysis are removed. The essential requirements are that the pure components be degassed completely since any deficiency in degassing would introduce errors into the measured pressures. A similarly essential requirement was that the central apparatus would have to be absolutely leak-tight as any leakage of air either in or out of the apparatus would introduce erroneous pressure readings. The apparatus was commissioned by measuring the saturated vapour pressures of both degassed water and ethanol as a function of temperature. The pressure-temperature data on degassed water measured were directly compared with data in the literature, with good agreement. Similarly the pressure-temperature data were measured for ethanol, methanol and cyclohexane and where possible a direct comparison made with the literature data. Good agreement between the pure component data of this work and those available in the literature demonstrates firstly that a satisfactory degassing procedure has been achieved and that secondly the measurements of pressure-temperature are consistent for any one component; since this is true for a number of components, the measurements of both temperature and pressure are both self-consistent and of sufficient accuracy, with an observed compatibility between the precision/accuracy of the separate means of measuring pressure and temperature. The liquid mixtures studied were of ethanol-water, methanol-water and ethanol-cyclohexane. The total pressure was measured as the composition inside the equilibrium cell was varied at a set temperature. This gave P-T-x data sets for each mixture at a range of temperatures. A standard fitting-package from the literature was used to reduce the raw data to yield y-values to complete the x-y-P-T data sets. A consistency test could not be applied to the P-T-x data set as no y-values were obtained during the experimental measurements. In general satisfactory agreement was found between the data of this work and those available in the literature. For some runs discrepancies were observed, and further work recommended to eliminate the problems identified.
Resumo:
The principles of High Performance Liquid Chromatography (HPLC) and pharmacokinetics were applied to the use of several clinically-important drugs at the East Birmingham Hospital. Amongst these was gentamicin, which was investigated over a two-year period by a multi-disciplinary team. It was found that there was considerable intra- and inter-patient variation that had not previously been reported and the causes and consequences of such variation were considered. A detailed evaluation of available pharmacokinetic techniques was undertaken and 1- and 2-compartment models were optimised with regard to sampling procedures, analytical error and model-error. The implications for control of therapy are discussed and an improved sampling regime is proposed for routine usage. Similar techniques were applied to trimethoprim, assayed by HPLC, in patients with normal renal function and investigations were also commenced into the penetration of drug into peritoneal dialysate. Novel assay techniques were also developed for a range of drugs including 4-aminopyridine, chloramphenicol, metronidazole and a series of penicillins and cephalosporins. Stability studies on cysteamine, reaction-rate studies on creatinine-picrate and structure-activity relationships in HPLC of aminopyridines are also reported.
Development of a multicellular co-culture model of normal and cystic fibrosis human airways in vitro
Resumo:
Cystic fibrosis (CF) is the most common lethal inherited disease among Caucasians and arises due to mutations in a chloride channel, called cystic fibrosis transmembrane conductance regulator. A hallmark of this disease is the chronic bacterial infection of the airways, which is usually, associated with pathogens such as Pseudomonas aeruginosa, S. aureus and recently becoming more prominent, B. cepacia. The excessive inflammatory response, which leads to irreversible lung damage, will in the long term lead to mortality of the patient at around the age of 40 years. Understanding the pathogenesis of CF currently relies on animal models, such as those employing genetically-modified mice, and on single cell culture models, which are grown either as polarised or non-polarised epithelium in vitro. Whilst these approaches partially enable the study of disease progression in CF, both types of models have inherent limitations. The overall aim of this thesis was to establish a multicellular co-culture model of normal and CF human airways in vitro, which helps to partially overcome these limitations and permits analysis of cell-to-cell communication in the airways. These models could then be used to examine the co-ordinated response of the airways to infection with relevant pathogens in order to validate this approach over animals/single cell models. Therefore epithelial cell lines of non-CF and CF background were employed in a co-culture model together with human pulmonary fibroblasts. Co-cultures were grown on collagen-coated permeable supports at air-liquid interface to promote epithelial cell differentiation. The models were characterised and essential features for investigating CF infections and inflammatory responses were investigated and analysed. A pseudostratified like epithelial cell layer was established at air liquid interface (ALI) of mono-and co-cultures and cell layer integrity was verified by tight junction (TJ) staining and transepithelial resistance measurements (TER). Mono- and co-cultures were also found to secrete the airway mucin MUC5AC. Influence of bacterial infections was found to be most challenging when intact S. aureus, B. cepacia and P. aeruginosa were used. CF mono- and co-cultures were found to mimic the hyperinflammatory state found in CF, which was confirmed by analysing IL-8 secretions of these models. These co-culture models will help to elucidate the role fibroblasts play in the inflammatory response to bacteria and will provide a useful testing platform to further investigate the dysregulated airway responses seen in CF.
Resumo:
The primary purpose of this study was to evaluate the effects of a single bout of moderate-intensity exercise on acute (ad libitum lunch) post-exercise energy intake (PE-EI) and 12-hour energy intake in normal-weight and overweight sedentary males. Accuracy in estimating energy intake (EI) and energy expenditure (EE), solid vs. liquid carbohydrate intake, mood, and perceived hunger were also assessed. The study consisted of two conditions, exercise and rest, with each subject participating in each condition, in a counterbalanced-crossover design on two days. The participants were randomly assigned to either the exercise or resting (seated) control condition on the first day of the experiment, and then the condition was reversed on the second day. Exercise consisted of walking on a treadmill at moderate-intensity for 60 minutes. Eighty males, mean age 30+8 years were categorized into five groups according to weight status (overweight/normal-weight), dietary restraint status (high/low), and dieting status (yes/no). The main effects of condition and group, and the interaction were not significant for acute (lunch) or 12-hour PE-EI. Overall, participants estimated EE for exercise at 46% higher than actual exercise EE, and they estimated EE for rest by 45% lower than actual resting EE. Participants significantly underestimated EI at lunch on both the exercise and rest days by 43% and 44%, respectively. Participants with high restraint were significantly better at estimating EE on the exercise day, and better at estimating EI on the rest day. Mood, perceived hunger, and solid vs. liquid carbohydrate intake were not influenced by dietary restraint, weight, or dieting status. In conclusion, a single bout of moderate-intensity exercise did not influence PE-EI in sedentary males in reference to dietary restraint, weight, and dieting status. Results also suggested that among sedentary males, there is a general inability to accurately estimate calories for moderate-intensity physical activity and EI. Inaccurate estimates of EE and EI have the potential to influence how males manage their weight.
Resumo:
The practices developed in the everyday life of obstetric services are sometimes out of step with the recommendations of the public health policies. Accordingly, this research had the objective of assessing the quality of the care provided to women and children during cases of natural childbirth in municipal public maternity wards of the city of Natal/RN, Brazilian Northeast. We developed a cross-sectional and quantitative study in two maternity wards that provide care actions to pregnant women at regular risk (maternity wards A and B). The participants were 314 puerperal women who were treated during the period between April and July 2014, whose children were born alive, through transpelvic way, with spontaneous or induced beginning of labor and that showed physical and emotional conditions to respond to the proposed questions. The data collection instrument was constructed on the basis of the recommendations of the World Health Organization focused on the care of normal childbirth and validated by skilled judges, and the final version has obtained optimum agreement (k = 0,96; IVC = 0,99). Associated with these recommendations, we used three indicators: percentage of women with induced labor or subjected to elective cesarean section (Indicator A); percentage of women served by a qualified health professional during labor and childbirth (Indicator B); and Bologna Index (Indicator C). The research obtained a favorable opinion of the Research Ethics Committee from the Federal University of Rio Grande do Norte, under the nº 562.313 and Certificate of Presentation for Ethics Appreciation: 25958513.0.0000.5537. The analysis of categories related to the recommendations of the World Health Organization was conducted by means of absolute and relative frequency and the Chi-square Pearson’s and Fisher’s exact tests made the comparison of the differences observed between the two maternity wards. Furthermore, we calculated the percentage of the indicators A and B and with the results of the Indicator C, the quality was assessed as follows: the closer to 5, the better will be the quality, and the closer to 0, the worst will be the quality, and the Mann-Whitney U test was used to compare the differences of the obtained averages. The significance level of 5% was considered in all statistical tests. The differences between the maternity wards were identified with regard to the provision of liquids orally (p=0,018), stimulus for non-supine positions (p=0,002), existence of partograph (p=0,001), support or welcoming by health professionals (p= 0,047), intravenous infusion (p<0,001), supine position (p<0,001), use of oxytocin (p<0,001), food and liquid restriction (p= 0,002) and, lastly, the fact of the touch is performed by more than 1 examiner (p=0,011). The indicators A and B showed percentages of 13,09% and 100%, respectively. The overall average of the Indicator C was equal to 2,07 (± 0,74). There was a statistically significant difference between the averages of the maternity wards (p<0,001). The care actions provided during the process of labor and childbirth is inappropriate, especially in the maternity ward B. It is necessary to implement improvements and redesign the obstetric model in force