965 resultados para LED light calibration system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The advantages offered by the electronic component LED (Light Emitting Diode) have caused a quick and wide application of this device in replacement of incandescent lights. However, in its combined application, the relationship between the design variables and the desired effect or result is very complex and it becomes difficult to model by conventional techniques. This work consists of the development of a technique, through artificial neural networks, to make possible to obtain the luminous intensity values of brake lights using LEDs from design data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. Purpose: This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux - Dabi Atlante) and three LED (Ultraled - Dabi Atlante, Ultrablue - DMC and Elipar Freelight - 3M ESPE). Methods: 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. Results: The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. Conclusion: Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To study the influence of color opacity and light-curing systems (halogen light vs blue LED) on the microhardness of a composite resin. Methods: Esthet-X composite resin (Dentsply), shades A2 and A2-O, was inserted in a stainless steel matrix (5 mm diameter and 2 mm deep) and was light cured for 40 seconds with a halogen light source (XL 3000; 3M/ESPE) or a blue LED (Optilight LD II; Gnatus). Eight groups of 15 specimens each were formed, and were further divided according to the light-curing systems, the exposed area (base and surface), and the opacity of the composite resin, producing 120 specimens. The specimens were next stored in distilled water for 24 hours, embedded in a chemically activated acrylic resin, then subjected to finishing and polishing with sandpaper and felt discs. Microhardness was measured with a Vickers Digital Microhardness meter, with a 50 g load for 30 seconds. The obtained microhardness means were analyzed by ANOVA and Tukey's multiple-comparison test at 5% significance level. Results: The surface microhardness was always greater than the base microhardness, regardless of the light-curing source. The halogen light lamp produced significantly higher composite resin microhardness means than the blue LED (57.61 vs. 42.53 HV) (p<0.05). Statistically significant differences (p<0.05) were obtained between the microhardness means for the different composite opacities; lowest microhardness in depth was produced by the A2-O shade. Conclusion: Composite resin opacity as well as the light-curing system influenced the microhardness of the material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A monoclonal antibody (mAb) is an important tool in medical biotechnology and the production of biopharmaceuticals, especially for disease diagnosis and treatment of infections, because the antibodies have a significant advantage over chemical agents used in conventional therapies . The last thirty years the technology of production of monoclonal antibodies developed mainly the technique of obtaining in vitro, but also of their production is laborious, the cost is high. A major element of the high cost of production is the fact that the long-term culture consumes a large amount of imported inputs with high added value. A major contribution of this work is to promote cell growth more quickly and efficiently. Currently, a great race to discover new technologies and techniques to synthesize new antibodies and significantly increase the production of murine mAbs. New technologies such as laser and LED are innovations and widespread in modern life, so much so that its use has proliferated worldwide, primarily in the medical field. Recent studies show a series of results from the influence of the LED light in biological tissues such as: increasing the rate of cell proliferation, increased production rate of fibroblasts, increasing the rate of synthesis of RNA and DNA synthesis of ATP, etc. To assess the contribution of the LED in the culture of Myeloma NS1murino compared to the standard procedure. - NS1 cells were provided and followed the criteria of culture medium of the Laboratory of Cellular Engineering Center of Botucatu (POPs). The same amount of cells was grown in bottles of 25 cm2 polystyrene Tissue Culture Treated, specifically marked and kept in special medium RPMI 1640 Gibco BRL  supplemented with fetal bovine serum 10%, essential amino acids and non-essential, glucose, insulin and antibiotics. It was used in LEDs Cromatek wavelength of 630nm, 475nm and 530nm. The groups were... (Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stem cells are defined as cells capable of self-renewal and differentiation into specialized cells when submited to external signalings in the enviroment. Among adult stem cells, mesenchymal cells occupy an important position because they can differentiate into mesodermal cells such as osteoblasts, adipocytes and chondrocytes. Cell therapy consists in the use of mesenchymal stem cells (MSC) in the treatment of degenerative diseases and harmed tissue reconstruction. Due to the longstanding and costly procedure for cultivation of MSC, it was proposed the use of low power light sources, such as light emitting diodes (LED), to optimize these factors. Recent works have shown a series of results from the influence of LED light on biological tissues such as increased rate of cell proliferation, increased RNA, DNA and ATP synthesis rate. The purpose of this study is to compare the biomodulator effect of LED light set at wavelengths 630nm ± 10nm and 805nm ± 10nm on the mesenchymal stem cells proliferation. For this, the mesenchymal stem cells culture adopted the procedure used in the Departament of Animal Reproduction and Veterinary Radiology of the Faculty of Veterinary Medicine and Animal Sciences of Botucatu. MSC were obtained from an adult horse bone marrow, and isolated by density gradient separation, with the FICOLL reagent and by centrifugation. The pellet containing the stem cells was removed and these were placed in low glucose DMEM culture medium, containing 10% fetal calf serum and antibiotics. The material was observed daily by inverted microscopy for monitoring the progression of the cells and subsequently the amount of cells were counted in a Neubauer counting chamber. The amount of MSC was obtained by cell culture seeded in 24 wells culture plate and segregated into three distinct groups: Group 1 was irradiated with wavelength set at 630nm ± 10 nm, Group... (Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to evaluate the photodynamic therapy (PDT) effect on root canals contaminated with Enterococcus faecalis using a light emitting diode (LED) light and a curcumin solution (CUR) as photosensitizer (PS). Eighty root canals from uniradicular human teeth were prepared with Protaper Universal rotary system and contaminated with E. faecalis for 21 days. They were divided as: GIa-PDT (CUR, pre-irradiation for 5 + 5 min of irradiation); GIb-PDT (CUR, pre-irradiation for 5 + 10 min of irradiation); GIIa-(CUR, pre-irradiation for 5 + 5 min without irradiation); GIIb-(CUR pre-irradiation for 5 + 10 min of irradiation); GIIIa-(physiological solution and irradiation for 5 min); and GIIIb-(physiological solution and irradiation for 10 min); positive and negative control groups. Collections from root canals were made at time intervals of 21 days after contamination, immediately after treatment, and 7 days after treatment, and submitted to colony forming units per milliter (CFU mL-1) counts. The data were submitted to ANOVA and Tukey multiple comparison tests, at a level of significance of 5 %. In the immediate post-treatment collection, group GIa showed greater bacterial reduction in comparison with GIIa, GIIb, GIIIa, GIIIb, and positive control (P < 0.05). At 7 days post-treatment, GIa showed significant bacterial reduction only in comparison with GIIIa (P < 0.05). Curcumin as sensitizer was effective by 5 min LED irradiation but not by 10 min irradiation PDT using LED light, and curcumin as PS was not effective in eliminating E. faecalis. No difference was observed for periods of irradiation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This aim of the present study was to evaluate the pulp chamber penetration of 35% hydrogen peroxide activated by LED (light-emitting diode) or Nd:YAG laser in bovine teeth, after an in-office bleaching technique. Forty-eight bovine lateral incisors were divided into four groups, acetate buffer was placed into the pulp chamber and bleaching agent was applied as follows: for group A (n = 12), activation was performed by LED; for group B (n = 12), activation was performed by Nd:YAG laser (60 mJ, 20 Hz); group C (n = 12) received no light or laser activation; and the control group (n = 12) received no bleaching gel application or light or laser activation. The acetate buffer solution was transferred to a glass tube and Leuco Crystal Violet and horseradish peroxidase were added, producing a blue solution. The optical density of this solution was determined spectrophotometrically and converted into microgram equivalents of hydrogen peroxide. The results were analysed using ANOVA and Tukey's test (5%). It was verified that the effect of activation was significant, as groups activated by LED or laser presented greater hydrogen peroxide penetration into the pulp chamber (0.499 +/- 0.622 microg) compared with groups that were not (0.198 +/- 0.218 microg). There was no statistically significant difference in the penetration of hydrogen peroxide into the pulp chamber between the two types of activation (LED or laser). The results suggest that activation by laser or LED caused an increase in hydrogen peroxide penetration into the pulp chamber.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ground-based Earth troposphere calibration systems play an important role in planetary exploration, especially to carry out radio science experiments aimed at the estimation of planetary gravity fields. In these experiments, the main observable is the spacecraft (S/C) range rate, measured from the Doppler shift of an electromagnetic wave transmitted from ground, received by the spacecraft and coherently retransmitted back to ground. If the solar corona and interplanetary plasma noise is already removed from Doppler data, the Earth troposphere remains one of the main error sources in tracking observables. Current Earth media calibration systems at NASA’s Deep Space Network (DSN) stations are based upon a combination of weather data and multidirectional, dual frequency GPS measurements acquired at each station complex. In order to support Cassini’s cruise radio science experiments, a new generation of media calibration systems were developed, driven by the need to achieve the goal of an end-to-end Allan deviation of the radio link in the order of 3×〖10〗^(-15) at 1000 s integration time. The future ESA’s Bepi Colombo mission to Mercury carries scientific instrumentation for radio science experiments (a Ka-band transponder and a three-axis accelerometer) which, in combination with the S/C telecommunication system (a X/X/Ka transponder) will provide the most advanced tracking system ever flown on an interplanetary probe. Current error budget for MORE (Mercury Orbiter Radioscience Experiment) allows the residual uncalibrated troposphere to contribute with a value of 8×〖10〗^(-15) to the two-way Allan deviation at 1000 s integration time. The current standard ESA/ESTRACK calibration system is based on a combination of surface meteorological measurements and mathematical algorithms, capable to reconstruct the Earth troposphere path delay, leaving an uncalibrated component of about 1-2% of the total delay. In order to satisfy the stringent MORE requirements, the short time-scale variations of the Earth troposphere water vapor content must be calibrated at ESA deep space antennas (DSA) with more precise and stable instruments (microwave radiometers). In parallel to this high performance instruments, ESA ground stations should be upgraded to media calibration systems at least capable to calibrate both troposphere path delay components (dry and wet) at sub-centimetre level, in order to reduce S/C navigation uncertainties. The natural choice is to provide a continuous troposphere calibration by processing GNSS data acquired at each complex by dual frequency receivers already installed for station location purposes. The work presented here outlines the troposphere calibration technique to support both Deep Space probe navigation and radio science experiments. After an introduction to deep space tracking techniques, observables and error sources, in Chapter 2 the troposphere path delay is widely investigated, reporting the estimation techniques and the state of the art of the ESA and NASA troposphere calibrations. Chapter 3 deals with an analysis of the status and the performances of the NASA Advanced Media Calibration (AMC) system referred to the Cassini data analysis. Chapter 4 describes the current release of a developed GNSS software (S/W) to estimate the troposphere calibration to be used for ESA S/C navigation purposes. During the development phase of the S/W a test campaign has been undertaken in order to evaluate the S/W performances. A description of the campaign and the main results are reported in Chapter 5. Chapter 6 presents a preliminary analysis of microwave radiometers to be used to support radio science experiments. The analysis has been carried out considering radiometric measurements of the ESA/ESTEC instruments installed in Cabauw (NL) and compared with the requirements of MORE. Finally, Chapter 7 summarizes the results obtained and defines some key technical aspects to be evaluated and taken into account for the development phase of future instrumentation.