958 resultados para LEAK DETECTORS
Resumo:
On average approximately 13% of the water that is withdrawn by Canadian municipal water suppliers is lost before it reaches final users. This is an important topic for several reasons: water losses cost money, losses force water agencies to draw more water from lakes and streams thereby putting more stress on aquatic ecosystems, leaks reduce system reliability, leaks may contribute to future pipe failures, and leaks may allow contaminants to enter water systems thereby reducing water quality and threatening the health of water users. Some benefits of leak detection fall outside water agencies’ accounting purview (e.g. reduced health risks to households connected to public water supply systems) and, as a result, may not be considered adequately in water agency decision-making. Because of the regulatory environment in which Canadian water agencies operate, some of these benefits-especially those external to the agency or those that may accrue to the agency in future time periods- may not be fully counted when agencies decide on leak detection efforts. Our analysis suggests potential reforms to promote increased efforts for leak detection: adoption of a Canada-wide goal of universal water metering; development of full-cost accounting and, pricing for water supplies; and co-operation amongst the provinces to promulgate standards for leak detection efforts and provide incentives to promote improved efficiency and rational investment decision-making.
Resumo:
En opération depuis 2008, l’expérience ATLAS est la plus grande de toutes les expériences au LHC. Les détecteurs ATLAS- MPX (MPX) installés dans ATLAS sont basés sur le détecteur au silicium à pixels Medipix2 qui a été développé par la collaboration Medipix au CERN pour faire de l’imagerie en temps réel. Les détecteurs MPX peuvent être utilisés pour mesurer la luminosité. Ils ont été installés à seize différents endroits dans les zones expérimentale et technique d’ATLAS en 2008. Le réseau MPX a recueilli avec succès des données indépendamment de la chaîne d’enregistrement des données ATLAS de 2008 à 2013. Chaque détecteur MPX fournit des mesures de la luminosité intégrée du LHC. Ce mémoire décrit la méthode d’étalonnage de la luminosité absolue mesurée avec les détectors MPX et la performance des détecteurs MPX pour les données de luminosité en 2012. Une constante d’étalonnage de la luminosité a été déterminée. L’étalonnage est basé sur technique de van der Meer (vdM). Cette technique permet la mesure de la taille des deux faisceaux en recouvrement dans le plan vertical et horizontal au point d’interaction d’ATLAS (IP1). La détermination de la luminosité absolue nécessite la connaissance précise de l’intensité des faisceaux et du nombre de trains de particules. Les trois balayages d’étalonnage ont été analysés et les résultats obtenus par les détecteurs MPX ont été comparés aux autres détecteurs d’ATLAS dédiés spécifiquement à la mesure de la luminosité. La luminosité obtenue à partir des balayages vdM a été comparée à la luminosité des collisions proton- proton avant et après les balayages vdM. Le réseau des détecteurs MPX donne des informations fiables pour la détermination de la luminosité de l’expérience ATLAS sur un large intervalle (luminosité de 5 × 10^29 cm−2 s−1 jusqu’à 7 × 10^33 cm−2 s−1 .
Resumo:
Within a drift-diffusion model we investigate the role of the self-consistent electric field in determining the impedance field of a macroscopic Ohmic (linear) resistor made by a compensated semi-insulating semiconductor at arbitrary values of the applied voltage. The presence of long-range Coulomb correlations is found to be responsible for a reshaping of the spatial profile of the impedance field. This reshaping gives a null contribution to the macroscopic impedance but modifies essentially the transition from thermal to shot noise of a macroscopic linear resistor. Theoretical calculations explain a set of noise experiments carried out in semi-insulating CdZnTe detectors.
Resumo:
La miniaturització de la industria microelectrònica és un fet del tot inqüestionables i la tecnologia CMOS no n'és una excepció. En conseqüència la comunitat científica s'ha plantejat dos grans reptes: En primer lloc portar la tecnologia CMOS el més lluny possible ('Beyond CMOS') tot desenvolupant sistemes d'altes prestacions com microprocessadors, micro - nanosistemes o bé sistemes de píxels. I en segon lloc encetar una nova generació electrònica basada en tecnologies totalment diferents dins l'àmbit de les Nanotecnologies. Tots aquests avanços exigeixen una recerca i innovació constant en la resta d'àrees complementaries com són les d'encapsulat. L'encapsulat ha de satisfer bàsicament tres funcions: Interfície elèctrica del sistema amb l'exterior, Proporcionar un suport mecànic al sistema i Proporcionar un camí de dissipació de calor. Per tant, si tenim en compte que la majoria d'aquests dispositius d'altes prestacions demanden un alt nombre d'entrades i sortides, els mòduls multixip (MCMs) i la tecnologia flip chip es presenten com una solució molt interessant per aquests tipus de dispositiu. L'objectiu d'aquesta tesi és la de desenvolupar una tecnologia de mòduls multixip basada en interconnexions flip chip per a la integració de detectors de píxels híbrids, que inclou: 1) El desenvolupament d'una tecnologia de bumping basada en bumps de soldadura Sn/Ag eutèctics dipositats per electrodeposició amb un pitch de 50µm, i 2) El desenvolupament d'una tecnologia de vies d'or en silici que permet interconnectar i apilar xips verticalment (3D packaging) amb un pitch de 100µm. Finalment aquesta alta capacitat d'interconnexió dels encapsulats flip chip ha permès que sistemes de píxels tradicionalment monolítics puguin evolucionar cap a sistemes híbrids més compactes i complexes, i que en aquesta tesi s'ha vist reflectit transferint la tecnologia desenvolupada al camp de la física d'altes energies, en concret implantant el sistema de bump bonding d'un mamògraf digital. Addicionalment s'ha implantat també un dispositiu detector híbrid modular per a la reconstrucció d'imatges 3D en temps real, que ha donat lloc a una patent.
Resumo:
Little has so far been reported on the performance of the near-far resistant CDMA detectors in the presence of the synchronization errors. Starting with the general mathematical model of matched filters, this paper examines the effects of three classes of synchronization errors (i.e. time-delay errors, carrier phase errors, and carrier frequency errors) on the performance (bit error rate and near-far resistance) of an emerging type of near-far resistant coherent DS/SSMA detectors, i.e. the linear decorrelating detector (LDD). For comparison, the corresponding results for the conventional detector are also presented. It is shown that the LDD can still maintain a considerable performance advantage over the conventional detector even when some synchronization errors exist. Finally, several computer simulations are carried out to verify the theoretical conclusions.
Resumo:
This paper addresses the effects of synchronisation errors (time delay, carrier phase, and carrier frequency) on the performance of linear decorrelating detectors (LDDs). A major effect is that all LDDs require certain degree of power control in the presence of synchronisation errors. The multi-shot sliding window algorithm (SLWA) and hard decision method (HDM) are analysed and their power control requirements are examined. Also, a more efficient one-shot detection scheme, called “hard-decision based coupling cancellation”, is proposed and analysed. These schemes are then compared with the isolation bit insertion (IBI) approach in terms of power control requirements.
Resumo:
Little has been reported on the performance of near-far resistant CDMA detectors in the presence of system parameter estimation errors (SPEEs). Starting with the general mathematical model of matched filters, the paper examines the effects of three classes of SPEEs, i.e., time-delay, carrier phase, and carrier frequency errors, on the performance (BER) of an emerging type of near-far resistant coherent DS/SSMA detector, i.e., the linear decorrelating detector. For comparison, the corresponding results for the conventional detector are also presented. It is shown that the linear decorrelating detector can still maintain a considerable performance advantage over the conventional detector even when some SPEEs exist.
Resumo:
This paper analyzes the convergence behavior of the least mean square (LMS) filter when used in an adaptive code division multiple access (CDMA) detector consisting of a tapped delay line with adjustable tap weights. The sampling rate may be equal to or higher than the chip rate, and these correspond to chip-spaced (CS) and fractionally spaced (FS) detection, respectively. It is shown that CS and FS detectors with the same time-span exhibit identical convergence behavior if the baseband received signal is strictly bandlimited to half the chip rate. Even in the practical case when this condition is not met, deviations from this observation are imperceptible unless the initial tap-weight vector gives an extremely large mean squared error (MSE). This phenomenon is carefully explained with reference to the eigenvalues of the correlation matrix when the input signal is not perfectly bandlimited. The inadequacy of the eigenvalue spread of the tap-input correlation matrix as an indicator of the transient behavior and the influence of the initial tap weight vector on convergence speed are highlighted. Specifically, a initialization within the signal subspace or to the origin leads to very much faster convergence compared with initialization in the a noise subspace.
Resumo:
Adaptive least mean square (LMS) filters with or without training sequences, which are known as training-based and blind detectors respectively, have been formulated to counter interference in CDMA systems. The convergence characteristics of these two LMS detectors are analyzed and compared in this paper. We show that the blind detector is superior to the training-based detector with respect to convergence rate. On the other hand, the training-based detector performs better in the steady state, giving a lower excess mean-square error (MSE) for a given adaptation step size. A novel decision-directed LMS detector which achieves the low excess MSE of the training-based detector and the superior convergence performance of the blind detector is proposed.
Resumo:
The triple- and quadruple-escape peaks of 6.128 MeV photons from the (19)F(p,alpha gamma)(16)O nuclear reaction were observed in an HPGe detector. The experimental peak areas, measured in spectra projected with a restriction function that allows quantitative comparison of data from different multiplicities, are in reasonably good agreement with those predicted by Monte Carlo simulations done with the general-purpose radiation-transport code PENELOPE. The behaviour of the escape intensities was simulated for some gamma-ray energies and detector dimensions; the results obtained can be extended to other energies using an empirical function and statistical properties related to the phenomenon. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The present paper describes the utilization of nickel hydroxide modified electrodes toward the catalytic oxidation of carbohydrates (glucose, fructose, lactose and sucrose) and their utilization as electrochemical sensor. The modified electrodes were employed as a detector in flow injection analysis for individual carbohydrate detection, and to an ionic column chromatography system for multi-analyte samples aiming a prior separation step. Kinetic studies were performed on a rotating disk electrode (RDE) in order to determine both the heterogeneous rate constant and number of electrons transferred for each carbohydrate. Many advantages were found for the proposed system including fast and easy handling of the electrode modification, low cost procedure, a wide range of linearity (0.5-50 ppm), low detection limits (ppb level) and high sensitivities. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
When an accurate hydraulic network model is available, direct modeling techniques are very straightforward and reliable for on-line leakage detection and localization applied to large class of water distribution networks. In general, this type of techniques based on analytical models can be seen as an application of the well-known fault detection and isolation theory for complex industrial systems. Nonetheless, the assumption of single leak scenarios is usually made considering a certain leak size pattern which may not hold in real applications. Upgrading a leak detection and localization method based on a direct modeling approach to handle multiple-leak scenarios can be, on one hand, quite straightforward but, on the other hand, highly computational demanding for large class of water distribution networks given the huge number of potential water loss hotspots. This paper presents a leakage detection and localization method suitable for multiple-leak scenarios and large class of water distribution networks. This method can be seen as an upgrade of the above mentioned method based on a direct modeling approach in which a global search method based on genetic algorithms has been integrated in order to estimate those network water loss hotspots and the size of the leaks. This is an inverse / direct modeling method which tries to take benefit from both approaches: on one hand, the exploration capability of genetic algorithms to estimate network water loss hotspots and the size of the leaks and on the other hand, the straightforwardness and reliability offered by the availability of an accurate hydraulic model to assess those close network areas around the estimated hotspots. The application of the resulting method in a DMA of the Barcelona water distribution network is provided and discussed. The obtained results show that leakage detection and localization under multiple-leak scenarios may be performed efficiently following an easy procedure.
Resumo:
We are presenting here p/n junctions obtained with a modified opened liquid-phase epitaxy (LPE) system, used to diffuse indium antimonide (InSb) doped with Cd over InSb doped with Te wafers, in order to make InSb infrared (IR) sensors. This technique has several advantages: the diffusion can be performed in bigger substrate areas improving the device production; this method decreases the device manipulation, decreasing human mistakes and increasing the process reproducibility. The opened LPE in this work produced sensors in the first case with vapor of the diffusion material, coming from a microholed carbon boat full of the diffusion material, over which is positioned the substrate at atmospheric pressure. In the second, the diffusion material is on the bottom of a quartz recipient, and the InSb/Te wafer works as its cover, and vacuum was used. The IR sensors produced with the first method measured 8.9 x 10(7) cm Hz(1/2)/W as detectivity value and higher IR spectral response at 4.6 mu m, and those produced with the second 2.8 x 10(9) cm Hz(1/2)/W, at 4.4 mu m. Besides the electrical-optical properties, the structural properties of diffused layers were investigated by X-ray diffraction (XRD), scanning electron and atomic force microscopy (SEM, AFM), energy-dispersive and secondary ion mass spectroscopy (EDS, SIMS). (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
This paper presents an experimental investigation of the characteristics of leak noise in plastic water-filled pipes. An experimental set-up was designed to identify the physical mechanisms of leak noise generation. Possible mechanisms include cavitation and turbulence. The experiments show that cavitation is not responsible for leak noise generation and clearly indicate that turbulence is the main mechanism, at least in the experiments conducted. An alternative experimental set-up was also designed to identify the characteristics of leak noise spectra and to investigate how the spectra are affected by the leak size and the leak flow velocity. A number of different hole sizes (leaks) starting from 1 mm diameter, increasing progressively every 0.5 mm until a size of 4 mm diameter were tested for different jet velocities and an empirical model that describes this behaviour is proposed.