949 resultados para Jamaica - Description and travel


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The new mineral francoisite-(Ce), (Ce,Nd,Ca)[(UO(2))(3)O(OH)(PO(4))(2)]center dot 6H(2)O is the Ce-analog of francoisite-(Nd). It has been discovered simultaneously at the La Creusaz uranium deposit near Les Marecottes in Valais, Switzerland, and at the Number 2 uranium Workings, Radium Ridge near Mt. Painter, Arkaroola area, Northern Flinders Ranges in South Australia. Francoisite-(Ce) is a uranyl-bearing supergene mineral that results from the alteration under oxidative conditions of REE- and U(4+)-bearing hypogene minerals: allanite-(Ce), monazite-(Ce), +/- uraninite at Les Marecottes; monazite-(Ce), ishikawaite-samarskite, and an unknown primary U-mineral at Radium Ridge. The REE composition of francoisite-(Ce) results from a short aqueous transport of REE leached out of primary minerals [most likely monazite-(Ce) at Radium Ridge and allanite-(Ce) at La Creusaz], with fractionation among REE resulting mainly from aqueous transport, with only limited Ce loss due to oxidation to Ce(4+) during transport.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new echinostome cercaria, Cercaria kuwaitae XI sp.n., from the prosobranch gastropod Cerithidea cingulata (Gmelin) from Kuwait Bay is described. The new cercaria is characterized by 23 collar spines and primary excretory tubules with distinct diverticula. The cercaria encysts in the snail host and is similar to those of Acanthoparyphium sp. The surface topography of the redia, cercaria and metacercarial cyst wall is studied by scanning electron microscopy. This is the first echinostome cercaria to be recorded in a gastropod from the Arabian Gulf region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Description and phylogenetic analysis of the Calycopidina (Lepidoptera, Lycaenidae, Theclinae, Eumaeini): a subtribe of detritivores. The purpose of this paper is to establish a phylogenetic basis for a new Eumaeini subtribe that includes those lycaenid genera in which detritivory has been recorded. Morphological characters were coded for 82 species of the previously proposed "Lamprospilus Section" of the Eumaeini (19 of these had coding identical to another species), and a phylogenetic analysis was performed using the 63 distinct ingroup terminal taxa and six outgroups belonging to four genera. Taxonomic results include the description in the Eumaeini of Calycopidina Duarte & Robbins new subtribe (type genus Calycopis Scudder, 1876), which contains Lamprospilus Geyer, Badecla Duarte & Robbins new genus (type species Thecla badaca Hewitson), Arzecla Duarte & Robbins new genus (type species Thecla arza Hewitson), Arumecla Robbins & Duarte, Camissecla Robbins & Duarte, Electrostrymon Clench, Rubroserrata K. Johnson & Kroenlein revalidated status, Ziegleria K. Johnson, Kisutam K. Johnson & Kroenlein revalidated status, and Calycopis. Previous "infratribe" names Angulopina K. Johnson & Kroenlein, 1993, and Calycopina K. Johnson & Kroenlein, 1993, are nomenclaturally unavailable and polyphyletic as proposed. New combinations include Badecla badaca (Hewitson), Badecla picentia (Hewitson), Badecla quadramacula (Austin & K. Johnson), Badecla lanckena (Schaus), Badecla argentinensis (K. Johnson & Kroenlein), Badecla clarissa (Draudt), Arzecla arza (Hewitson), Arzecla tarpa (Godman & Salvin), Arzecla canacha (Hewitson), Arzecla calatia (Hewitson), Arzecla tucumanensis (K. Johnson & Kroenlein), Arzecla sethon (Godman & Salvin), Arzecla nubilum (H. H. Druce), Arzecla paralus (Godman & Salvin), Arzecla taminella (Schaus), Arzecla albolineata (Lathy), Electrostrymon denarius (Butler & H.Druce), Electrostrymon guzanta (Schaus), Electrostrymon perisus (H. H. Druce), Rubroserrata mathewi (Hewitson), Rubroserrata ecbatana (Hewitson), Kisutam micandriana (K. Johnson), and Kisutam syllis (Godman & Salvin). The structure of the male genitalia lateral window, labides, and brush organs are described and discussed, as are the female genitalia signa of the corpus bursae and 8th abdominal tergum. Widespread wing pattern sexual dimorphism in the Calycopidina is noted and illustrated, and the presence of alternating dark and light bands on the ventral wings of both sexes is discussed. The evidence for detritivory in Lamprospilus, Badecla, Arzecla, Arumecla, Camissecla, Electrostrymon, Ziegleria, Kisutam, and Calycopis is summarized using the new classification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a model and solution methods, for locating a fixed number ofmultiple-server, congestible common service centers or congestible publicfacilities. Locations are chosen so to minimize consumers congestion (orqueuing) and travel costs, considering that all the demand must be served.Customers choose the facilities to which they travel in order to receiveservice at minimum travel and congestion cost. As a proxy for thiscriterion, total travel and waiting costs are minimized. The travel costis a general function of the origin and destination of the demand, whilethe congestion cost is a general function of the number of customers inqueue at the facilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The risk of contracting a sexually transmitted infection while traveling abroad is increased in certain populations. Pre-travel consultation should include the education of travelers on the prevalence of HIV in the countries visited and on appropriate prevention measures. In patients infected with HIV (PHIV), combined antiretroviral therapy (cART) improves immunity, enabling them to travel with less risk for their health. Pre-travel consultation of PVIH has the following objectives: to determine immune status, to update immunization and to decide on anti-malaria drug prophylaxis, taking into account potential drug interactions with antiretroviral therapy. Vaccine response and duration of protection is shorter-lived in PVIH, especially if the CD4 count is below 200 cells/mm3 and the HIV viral load is detectable. Therefore cART is a cornerstone for disease prevention among patients infected with HIV who travel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry. METHODS: Thirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student. RESULTS: The global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83. CONCLUSIONS: The described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACTMale, female, pupa, and last-instar larva of Palaeomystella beckeri (Moreira and Basilio) a new species from the Atlantic forest, southern Brazil, are described and illustrated with the aid of optical and scanning electron microscopy. Larvae induce galls on apical branches of Tibouchina trichopoda (DC.) Baill. (Melastomataceae) within which pupation occurs. Gall description and preliminary data on life history are also provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

l'imagerie par résonance magnétique (IRMC) est une technologie utilisée depuis les aimées quatre¬-vingts dans le monde de la cardiologie. Cette technique d'imagerie non-invasive permet d'acquérir Ses images du coeur en trois dimensions, dans n'importe quel, plan, sans application de radiation, et en haute résolution. Actuellement, cette technique est devenue un référence dans l'évaluation et 'l'investigation de différentes pathologies cardiaques. La morphologie cardiaque, la fonction des ventricules ainsi que leur contraction, la perfusion tissulaire ainsi que la viabilité tissulaire peuvent être caractérisés en utilisant différentes séquences d'imagerie. Cependant, cette technologie repose sur des principes physiques complexes et la mise en pratique de cette technique se heurte à la difficulté d'évaluer un organe en mouvement permanent. L'IRM cardiaque est donc sujette à différents artefacts qui perturbent l'interprétation des examens et peuvent diminuer la précision diagnostique de cette technique. A notre connaissance, la plupart des images d'IRMC sont analysées et interprétées sans évaluation rigoureuse de la qualité intrinsèque de l'examen. Jusqu'à présent, et à notre connaissance, aucun critère d'évaluation de la qualité des examens d'IRMC n'a été clairement déterminé. L'équipe d'IRMC du CHUV, dirigée par le Prof J. Schwitter, a recensé une liste de 35 critères qualitatifs et 12 critères quantitatifs évaluant la qualité d'un examen d'IRMC et les a introduit dans une grille d'évaluation. L'objet de cette étude est de décrire et de valider la reproductibilité des critères figurant dans cette grille d'évaluation, par l'interprétation simultanée d'examens IRMC par différents observateurs (cardiologues spécialisés en IRM, étudiant en médecine, infirmière spécialisée). Notre étude a permis de démontrer que les critères définis pour l'évaluation des examens d'IRMC sont robustes, et permettent une bonne reproductibilité intra- et inter-observateurs. Cette étude valide ainsi l'utilisation de ces critères de qualité dans le cadre de l'imagerie par résonance magnétique cardiaque. D'autres études sont encore nécessaires afin de déterminer l'impact de la qualité de l'image sur la précision diagnostique de cette technique. Les critères standardisés que nous avons validés seront utilisés pour évaluer la qualité des images dans le cadre d'une étude à échelle européenne relative à l'IRMC : "l'EuroCMR registry". Parmi les autres utilités visées par ces critères de qualité, citons notamment la possibilité d'avoir une référence d'évaluation de la qualité d'examen pour toutes les futures études cliniques utilisant la technologie d'IRMC, de permettre aux centres d'IRMC de quantifier leur niveau de qualité, voire de créer un certificat de standard de qualité pour ces centres, d'évaluer la reproductibilité de l'évaluation des images par différents observateurs d'un même centre, ou encore d'évaluer précisément la qualité des séquences développées à l'avenir dans le monde de l'IRMC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In August 2008, reactivation of the Little Salmon Lake landslide occurred. During this event, hundreds of conical mounds of variable size and composition formed in the deposition zone. The characteristics of these landforms are described and a potential mechanism for their formation is proposed. A preliminary slope stability analysis of the 2007 Mount Steele rock and ice avalanche was also undertaken. The orientation of very high persistence (>20 m long) structural planes (e.g., faults, joints and bedding) within bedrock in the source zone was obtained using an airborne-LiDAR digital elevation model and the software COLTOP-3D. Using these discontinuity orientation measurements, kinematic, surface wedge and simple three-dimensional distinct element slope stability analyses were performed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This issue review provides an analysis of the Economic Development Authority Tourism Office advertising funding and expenditures, along with a review of the methodology and results of the economic impact of travel on Iowa counties study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The production and use of false identity and travel documents in organized crime represent a serious and evolving threat. However, a case-by-case perspective, thus suffering from linkage blindness and a limited analysis capacity, essentially drives the present-day fight against this criminal problem. To assist in overcoming these limitations, a process model was developed using a forensic perspective. It guides the systematic analysis and management of seized false documents to generate forensic intelligence that supports strategic and tactical decision-making in an intelligence-led policing approach. The model is articulated on a three-level architecture that aims to assist in detecting and following-up on general trends, production methods and links between cases or series. Using analyses of a large dataset of counterfeit and forged identity and travel documents, it is possible to illustrate the model, its three levels and their contribution. Examples will point out how the proposed approach assists in detecting emerging trends, in evaluating the black market's degree of structure, in uncovering criminal networks, in monitoring the quality of false documents, and in identifying their weaknesses to orient the conception of more secured travel and identity documents. The process model proposed is thought to have a general application in forensic science and can readily be transposed to other fields of study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this article, I address epistemological questions regarding the status of linguistic rules and the pervasive--though seldom discussed--tension that arises between theory-driven object perception by linguists on the one hand, and ordinary speakers' possible intuitive knowledge on the other hand. Several issues will be discussed using examples from French verb morphology, based on the 6500 verbs from Le Petit Robert dictionary (2013).