953 resultados para Intervertebral disk displacement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate measurement of intervertebral kinematics of the cervical spine can support the diagnosis of widespread diseases related to neck pain, such as chronic whiplash dysfunction, arthritis, and segmental degeneration. The natural inaccessibility of the spine, its complex anatomy, and the small range of motion only permit concise measurement in vivo. Low dose X-ray fluoroscopy allows time-continuous screening of cervical spine during patient's spontaneous motion. To obtain accurate motion measurements, each vertebra was tracked by means of image processing along a sequence of radiographic images. To obtain a time-continuous representation of motion and to reduce noise in the experimental data, smoothing spline interpolation was used. Estimation of intervertebral motion for cervical segments was obtained by processing patient's fluoroscopic sequence; intervertebral angle and displacement and the instantaneous centre of rotation were computed. The RMS value of fitting errors resulted in about 0.2 degree for rotation and 0.2 mm for displacements. © 2013 Paolo Bifulco et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We revisit the classical Karman rotating disk problem. A series analysis is used to derive estimates of boundary conditions at the surface. Using these estimates, computed thermal and flow fields for large mass transfer through the disk are readily obtained using a shooting method. The relevance of the problem to practical flows is discussed briefly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract—Corneal topography estimation that is based on the Placido disk principle relies on good quality of precorneal tear film and sufficiently wide eyelid (palpebral) aperture to avoid reflections from eyelashes. However, in practice, these conditions are not always fulfilled resulting in missing regions, smaller corneal coverage, and subsequently poorer estimates of corneal topography. Our aim was to enhance the standard operating range of a Placido disk videokeratoscope to obtain reliable corneal topography estimates in patients with poor tear film quality, such as encountered in those diagnosed with dry eye, and with narrower palpebral apertures as in the case of Asian subjects. This was achieved by incorporating in the instrument’s own topography estimation algorithm an image processing technique that comprises a polar-domain adaptive filter and amorphological closing operator. The experimental results from measurements of test surfaces and real corneas showed that the incorporation of the proposed technique results in better estimates of corneal topography, and, in many cases, to a significant increase in the estimated coverage area making such an enhanced videokeratoscope a better tool for clinicians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis investigates Theatre for Young People (TYP) as a site of performance innovation. The inquiry is focused on contemporary dramaturgy and its fieldwork aims to identify new dramaturgical principles operating in the creation and presentation of TYP. The research then seeks to assess how these new principles contribute to Postdramatic Theatre theory. This research inquiry springs from an imperative based in practice: Young people under 25 years have a literacy based on online hypertextual experiences which take the reader outside the frames of a dramatic narrative and beyond principles such as linearity, dramatic unity, teleology and resolution. As a dramaturg and educator I wanted to understand the new ways that young people engage in cultural products, to identify and utilize the new principles of dramaturgy that are now in evidence. My research examines how two playwright/directors approach their work and the new principles that can be identified in their dramaturgy. The fieldwork is scoped into two case studies: the first on TJ Eckleberg working in Australian Theatre for Young People and the second on Kristo Šagor working in German Children’s and Young People’s Theatre (KJT). These case studies address both types of production dramaturgy - the dramaturgy emergent through process in devised performance making, and that emergent in a performance based on a written playscript. On Case Study One the researcher, as participant observer, worked as production dramaturg on a large scale, site specific performance, observing the dramaturgy in process of its director and chief devisor. On Case Study Two the researcher, as observer and analyst, undertook a performance analysis of three playscripts and productions by a contemporary German playwright and director. Utilizing participant observation, reflective practice and grounded analysis the case studies have identified two new principles animating the dramaturgy of these TYP practitioners, namely ‘displacement’ and ‘installation.’ Taking practice into theory, the thesis concludes by demonstrating how displacement and installation contribute to Postdramatic Theatre’s “arsenal of expressive gestures which serve as theatre’s response to changed social communication under the conditions of generalized communication technologies” (Lehmann, H.-T., 2006, p.23). This research makes an original contribution to knowledge by evidencing that the principles of Postdramatic Theory lie within the practice of contemporary Theatre for Young People. It also contributes valuable research to a specialized, often overlooked terrain, namely Dramaturgy in Theatre for Young People, presented here with a contemporary, international and intercultural perspective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forensic imaging has been facing scalability challenges for some time. As disk capacity growth continues to outpace storage IO bandwidth, the demands placed on storage and time are ever increasing. Data reduction and de-duplication technologies are now commonplace in the Enterprise space, and are potentially applicable to forensic acquisition. Using the new AFF4 forensic file format we employ a hash based compression scheme to leverage an existing corpus of images, reducing both acquisition time and storage requirements. This paper additionally describes some of the recent evolution in the AFF4 file format making the efficient implementation of hash based imaging a reality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since 2000-2001, dengue virus type 1 has circulated in the Pacific region. However, in 2007, type 4 reemerged and has almost completely displaced the strains of type 1. If only 1 serotype circulates at any time and is replaced approximately every 5 years, DENV-3 may reappear in 2012.