909 resultados para Interval signals and systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fruit bat Rousettus aegyptiacus has highly mobile pinnae. Little is known about the role that such movements play in sound localisation however and whether they interact with the process of echolocation in this species. Here we report the correspondence of echolocation signals in free flight with the downward wingbeat and forward movement of the pinnae, and demonstrate that the ears have a greater sensitivity to click stimuli in front of the animal when directed forwards than when back and to the side. The potential significance of the production of echolocation signals whilst the ears are moving from their least sensitive to their most sensitive position is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Wing-Kristofferson (WK) model of movement timing emphasises the separation of central timer and motor processes. Several studies of repetitive timing have shown that increase in variability at longer intervals is attributable to timer processes; however, relatively little is known about the way motor aspects of timing are affected by task movement constraints. In the present study, we examined timing variability in finger tapping with differences in interval to assess central timer effects, and with differences in movement amplitude to assess motor implementation effects. Then, we investigated whether effects of motor timing observed at the point of response (flexion offset/tap) are also evident in extension, which would suggest that both phases are subject to timing control. Eleven participants performed bimanual simultaneous tapping, at two target intervals (400, 600 ms) with the index finger of each hand performing movements of equal (3 or 6 cm) or unequal amplitude (left hand 3, right hand 6 cm and vice versa). As expected, timer variability increased with the mean interval but showed only small, non-systematic effects with changes in movement amplitude. Motor implementation variability was greater in unequal amplitude conditions. The same pattern of motor variability was observed both at flexion and extension phases of movement. These results suggest that intervals are generated by a central timer, triggering a series of events at the motor output level including flexion and the following extension, which are explicitly represented in the timing system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Virtual metrology (VM) aims to predict metrology values using sensor data from production equipment and physical metrology values of preceding samples. VM is a promising technology for the semiconductor manufacturing industry as it can reduce the frequency of in-line metrology operations and provide supportive information for other operations such as fault detection, predictive maintenance and run-to-run control. Methods with minimal user intervention are required to perform VM in a real-time industrial process. In this paper we propose extreme learning machines (ELM) as a competitive alternative to popular methods like lasso and ridge regression for developing VM models. In addition, we propose a new way to choose the hidden layer weights of ELMs that leads to an improvement in its prediction performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The photoacoustic investigations carried out on different photonic materials are presented in this thesis. Photonic materials selected for the investigation are tape cast ceramics, muItilayer dielectric coatings, organic dye doped PVA films and PMMA matrix doped with dye mixtures. The studies are performed by the measurement of photoacoustic signal generated as a result of modulated cw laser irradiation of samples. The gas-microphone scheme is employed for the detection of photoacoustic signal. The different measurements reported here reveal the adaptability and utility of the PA technique for the characterization of photonic materials.Ceramics find applications in the field of microelectronics industry. Tape cast ceramics are the building blocks of many electronic components and certain ceramic tapes are used as thermal barriers. The thermal parameters of these tapes will not be the same as that of thin films of the same materials. Parameters are influenced by the presence of foreign bodies in the matrix and the sample preparation technique. Measurements are done on ceramic tapes of Zirconia, Zirconia-Alumina combination, barium titanate, barium tin titanate, silicon carbide, lead zirconate titanateil'Z'T) and lead magnesium niobate titanate(PMNPT). Various configurations viz. heat reflection geometry and heat transmission geometry of the photoacoustic technique have been used for the evaluation of different thermal parameters of the sample. Heat reflection geometry of the PA cell has been used for the evaluation of thermal effusivity and heat transmission geometry has been made use of in the evaluation of thermal diffusivity. From the thermal diffusivity and thermal effusivity values, thermal conductivity is also calculated. The calculated values are nearly the same as the values reported for pure materials. This shows the feasibility of photoacoustic technique for the thermal characterization of ceramic tapes.Organic dyes find applications as holographic recording medium and as active media for laser operations. Knowledge of the photochemical stability of the material is essential if it has to be used tor any of these applications. Mixing one dye with another can change the properties of the resulting system. Through careful mixing of the dyes in appropriate proportions and incorporating them in polymer matrices, media of required stability can be prepared. Investigations are carried out on Rhodamine 6GRhodamine B mixture doped PMMA samples. Addition of RhB in small amounts is found to stabilize Rh6G against photodegradation and addition of Rh6G into RhB increases the photosensitivity of the latter. The PA technique has been successfully employed for the monitoring of dye mixture doped PMMA sample. The same technique has been used for the monitoring of photodegradation ofa laser dye, cresyl violet doped polyvinyl alcohol also.Another important application of photoacoustic technique is in nondestructive evaluation of layered samples. Depth profiling capability of PA technique has been used for the non-destructive testing of multilayer dielectric films, which are highly reflecting in the wavelength range selected for investigations. Eventhough calculation of thickness of the film is not possible, number of layers present in the system can be found out using PA technique. The phase plot has clear step like discontinuities, the number of which coincides with the number of layers present in the multilayer stack. This shows the sensitivity of PA signal phase to boundaries in a layered structure. This aspect of PA signal can be utilized in non-destructive depth profiling of reflecting samples and for the identification of defects in layered structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interference with time estimation from concurrent nontemporal processing has been shown to depend on the short-term memory requirements of the concurrent task (Fortin Breton, 1995; Fortin, Rousseau, Bourque, & Kirouac, 1993). In particular, it has been claimed that active processing of information in short-term memory produces interference, whereas simply maintaining information does not. Here, four experiments are reported in which subjects were trained to produce a 2,500-msec interval and then perform concurrent memory tasks. Interference with timing was demonstrated for concurrent memory tasks involving only maintenance. In one experiment, increasing set size in a pitch memory task systematically lengthened temporal production. Two further experiments suggested that this was due to a specific interaction between the short-term memory requirements of the pitch task and those of temporal production. In the final experiment, subjects performed temporal production while concurrently remembering the durations of a set of tones. Interference with interval production was comparable to that produced by the pitch memory task. Results are discussed in terms of a pacemaker-counter model of temporal processing, in which the counter component is supported by short-term memory.

Relevância:

100.00% 100.00%

Publicador: