1000 resultados para Interpretação de imagem radiográfica
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Imaging diagnosis is a medical specialty that uses imaging techniques to perform diagnosis. In diagnostic imaging various methods are used such as direct absorption of photons - SPA and DPA, radiographic photometry, the dual-energy radiographic absorptiometry - DEXA, ultrasound, magnetic resonance imaging, computed tomography and optical densitometry in radiographic image. The dog can be considered one of the most widely used animals in the study of bone diseases and searching for a reliable diagnosis, although not an ideal model for the study of osteoporosis, because these animals tend not to develop a decrease in bone mineral density. The objective of this study was to analyze bone density in mongrel dogs from the determination of the variation of density along the radio-ulna bone and also the mean value related to gender, weight and age of individuals. The density analysis carried out showed that for this data set, there is a significant difference in the case of gender and age of the animal and may generalize according to these variables. The only significant difference was found in the weight, which increases bone mass is related to weight gain through the growth of the animal
Resumo:
Computed Radiography (CR) is a term used to describe the system that electronically records a radiographic image. CR systems use receivers or IP (imaging plate) to capture the analog signals and then allow the readers to do the image processing and converted into digital information. With the increasing expansion of the CR for medical diagnostics it is necessary that these systems receive the same type of monitoring related to Quality Control and Acceptance to the conventional processing systems. The current legislation fails to specify the parameters and procedures to be tested, allowing that somehow, some equipment is not fully able to use in clinical routine. In this project we used the standard AAPM Report Number 93, which is already fully established outside the country and displays all test parameters in CR. From there were chosen three types of tests that were performed in a satisfactory sampling of IP´s. With this procedure it was possible to establish which of those IP's should be out of use, which reveals the important purpose of the study, demonstrating the need for Quality Control Testing and Acceptance in Computerized Radiography as soon as possible are included in the legislation regulator in the country
Resumo:
Paediatric diagnostic radiology can be considered as a separate specialty and with distinct characteristics of the radiology applied in adult patients. This in reason of the variability in the anatomical structures size and bigger sensitivity of tissues. The literature present in its majority methodologies for segmentation and tissue classification in adult patients, and works on tissue quantification are rare. This work had for objective the development of a biological tissue classifier and quantifier algorithm, from histograms, and that converts the quantified average thickness of these tissues for its respective simulator materials. The results will be used in the optimization process of paediatrics images, in future works, since these patients are frequently over exposed to the radiation in the repeated attempts of if getting considered good quality radiographic images. The developed algorithm was capable to read and store the name of all the archives, in the operational system, to filter artifacs, to count and quantify each biological tissues from the histogram of the examination, to obtain the biological tissues average thicknesses and to convert this value into its respective simulator material. The results show that it is possible to distinguish bone, soft, fat and pulmonary tissues from histograms of tomographic examinations of thorax. The quantification of the constituent materials of anthropomorphic phantom made by the algorithm, compared with the data of literature shows that the biggest difference was of 21,6% for bone. However, the literature shows that variations of up to 30% in bone thickness do not influence of significant form in the radiographic image quality. The average thicknesses of biological tissues, quantified for paediatrics patients, show that one phantom can simulate patients with distinct DAP ranges, since variations... (Complete abstract click electronic access below)
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
By the early 20th century, the blood vessels could only be seen by anatomical studies. Shortly after the discovery of X-rays by Conrad Roentgen in 1895, the first experiments with radiographic imaging were performed with blood vessels. In 1905, the first experiment involving catheterization of arterial and venous system in dogs was performed and only in 1914 performed on living human patients. Parallel to these landmarks, there were advances in diagnostic imaging devices and the evolution of contrast substances was of utmost importance to the current angiography occupy a prominent role not only in terms of diagnosis, but also in the treatment of various disorders. The main objective of this review is to weave historical considerations and comparisons between the different methodologies used in angiography, because its importance; that may be in future, a veterinary diagnostic decisive test
Resumo:
STRATIGRAPHIC SUCCESSION OF ALAGOAS STAGE ON SERRA DO TONÃ, TUCANO BASIN (BAHIA). Located in northeast of Bahia, serra do Tonã is a NS elongated plateau that standsout in the flattened relief of Tucano Basin. The stratigraphic succession belongs to the Aptian post-rift sequence of this basin. Based on facies analysis, vertical stratigraphic profiles and satelite images interpretation, three stacked stratigraphic units were recognized: (1) lower carbonate unit, composed by laminated limestones and breccias, 5 m thick, correlated with Camadas Batateira of Arripe Basin; (2) intermediate siliciclastic unit, 100m thick and made of sandstones exhibiting finning upward cycles, overlaid by mudstones and sandstones wich sedimentary structures suggest action of tidal currents and (3) upper carbonate unit, composed by laminated limestones, 2-10 m thick, related with Santana Formation, that record lacustrine environment with possible marine influence. Paleocurrent analysis indicates proviniance from north and paleoflows towards south, similar to the Aptian fluvial facies of Araripe Basin, showing that both basins integrated the same continental paleodrainage
Resumo:
This paper considers a study of the anatomical features of the cardiac system and a three-dimensional model of the different tunics that comprise the heart wall, for processing and quality control of radiological images. The structures are built by the layer overlapping method, where a layer can be understood as a slice of the three-dimensional object. The pericardium, myocardium and endocardium were represented with three-dimensional cylinders and hexagons. The spatial arrangement of the cardiac system is determined by an background image of a real model, which values are defined according to the shape of the region and on the anatomical patients characteristics. The results are significant, considering the anatomical structures details, as well as the representation of the thicknesses of the regions of the heart wall. The validation of the anatomical model was accomplished through comparisons with dimensions obtained from a real model and allows verifying that the model is appropriate. The degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the diseases on the quality of the images, as well as on the performance of the Computer-Aided Diagnosis (CAD).
Resumo:
O exame radiográfico é um procedimento simples e relativamente barato que pode ser utilizado para observação de estruturas ósseas e tecidos moles, incluindo suas alterações, sendo muito empregado em casos de suspeita de aumento de volume ósseo devido a tumores e inflamações. Osteossarcoma e osteomielite, além de causarem a alteração radiográfica acima citada, possuem imagem radiográfica muito semelhante na maioria dos casos, como proliferação e/ou lise óssea, presença do triângulo de Codman e perda do padrão trabecular ósseo, além de sintomas clínicos similares como claudicação e possível presença de fraturas patológicas. A necessidade de se realizar outros métodos de exame complementar paralelos à radiografia é muito importante na determinação de um diagnóstico seguro, o que implica em um tratamento precoce da doença evitando-se assim grande piora no estado geral do paciente. Esta revisão sistemática de literatura visa a comparação radiográfica entre osteomielite e osteossarcoma em cães, para auxilio do médico veterinário na diferenciação de seu diagnóstico.
Resumo:
The author has verified the average depth of the mandibular fossa, in the X-ray image, using the oblique lateral transcranial technique from the right and left sides samples of each patient, which included a total of 176 patients, 87 male and 89 female. The patients were in following phases: deciduous dentítion (the patients had only deciduous teeth in the oral cavity or, if they had any permanent teeth, they could not be in occlusion), mixed dentition (the patients presented deciduous and permanent in the oral cavity) and permanent dentition (the patients had only permanent teeth in the oral cavity), until the eruption of the permanent third molars, in the region from São José dos Campos. São Paulo. Brazil. The patients were under treatment at the Dental School. UNESP (São Paulo State University). ln order to measure the depth of the mandibular fossa in millimeters an imaginary line was traced on the X-ray image, perpendicular to the other line that served as a reference, which was traced from the botton part of the articular eminence up to the tympanosquamous fissure. After the data were obtained and put in a data sheet, they underwent statistical analysis. The results showed that, in the average, the depth of the mandibular fossa in masculine sex is non-statistically signíficant larger than what was observed in feminíne sex, and the right side is larger than the left side, with significant statistical differences. However, only in permanent dentition, in masculine sex, the depth of the mandibular fossa on the right side is larger than on the left side with significant statistical differences