995 resultados para Internal conical interface connection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper results are shown to indicate the efficacy of a direct connection between the human nervous system and a computer network. Experimental results obtained thus far from a study lasting for over 3 months are presented, with particular emphasis placed on the direct interaction between the human nervous system and a piece of wearable technology. An overview of the present state of neural implants is given, as well as a range of application areas considered thus far. A view is also taken as to what may be possible with implant technology as a general purpose human-computer interface for the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The impact of the variation of the Coriolis parameter f on the drag exerted by internal Rossby-gravity waves on elliptical mountains is evaluated using linear theory, assuming constant wind and static stability and a beta-plane approximation. Previous calculations of inertia-gravity wave drag are thus extended in an attempt to establish a connection with existing studies on planetary wave drag, developed primarily for fluids topped by a rigid lid. It is found that the internal wave drag for zonal westerly flow strongly increases relative to that given by the calculation where f is assumed to be a constant, particularly at high latitudes and for mountains aligned meridionally. Drag increases with mountain width for sufficiently wide mountains, reaching values much larger than those valid in the non-rotating limit. This occurs because the drag receives contributions from a low wavenumber range, controlled by the beta effect, which accounts for the drag amplification found here. This drag amplification is shown to be considerable for idealized analogues of real mountain ranges, such as the Himalayas and the Rocky mountains, and comparable to the barotropic Rossby wave drag addressed in previous studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-drag states produced in stratified flow over a 2D ridge and an axisymmetric mountain are investigated using a linear, hydrostatic, analytical model. A wind profile is assumed where the background velocity is constant up to a height z1 and then decreases linearly, and the internal gravity-wave solutions are calculated exactly. In flow over a 2D ridge, the normalized surface drag is given by a closed-form analytical expression, while in flow over an axisymmetric mountain it is given by an expression involving a simple 1D integral. The drag is found to depend on two dimensionless parameters: a dimensionless height formed with z_1, and the Richardson number, Ri, in the shear layer. The drag oscillates as z_1 increases, with a period of half the hydrostatic vertical wavelength of the gravity waves. The amplitude of this modulation increases as Ri decreases. This behaviour is due to wave reflection at z_1. Drag maxima correspond to constructive interference of the upward- and downward-propagating waves in the region z < z_1, while drag minima correspond to destructive interference. The reflection coefficient at the interface z = z_1 increases as Ri decreases. The critical level, z_c, plays no role in the drag amplification. A preliminary numerical treatment of nonlinear effects is presented, where z_c appears to become more relevant, and flow over a 2D ridge qualitatively changes its character. But these effects, and their connection with linear theory, still need to be better understood.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The problem of the world greatest lake, the Caspian Sea, level changes attracts the increased attention due to its environmental consequences and unique natural characteristics. Despite the huge number of studies aimed to explain the reasons of the sea level variations the underlying mechanism has not yet been clarified. The important question is to what extent the CSL variability is linked to changes in the global climate system and to what extent it can be explained by internal natural variations in the Caspian regional hydrological system. In this study an evidence of a link between the El Niño/Southern Oscillation phenomenon and changes of the Caspian Sea level is presented. This link was also found to be dominating in numerical experiments with the ECHAM4 atmospheric general circulation model on the 20th century climate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the checkerboard DNA-DNA hybridization method for detection and quantitation of bacteria from the internal parts of dental implants and to compare bacterial leakage from implants connected either to cast or to pre-machined abutments. Nine plastic abutments cast in a Ni-Cr alloy and nine pre-machined Co-Cr alloy abutments with plastic sleeves cast in Ni-Cr were connected to Branemark-compatible implants. A group of nine implants was used as control. The implants were inoculated with 3 mu l of a solution containing 10(8) cells/ml of Streptococcus sobrinus. Bacterial samples were immediately collected from the control implants while assemblies were completely immersed in 5 ml of sterile Tripty Soy Broth (TSB) medium. After 14 days of anaerobic incubation, occurrence of leakage at the implant-abutment interface was evaluated by assessing contamination of the TSB medium. Internal contamination of the implants was evaluated with the checkerboard DNA-DNA hybridization method. DNA-DNA hybridization was sensitive enough to detect and quantify the microorganism from the internal parts of the implants. No differences in leakage and in internal contamination were found between cast and pre-machined abutments. Bacterial scores in the control group were significantly higher than in the other groups (P < 0.05). Bacterial leakage through the implant-abutment interface does not significantly differ when cast or pre-machined abutments are used. The checkerboard DNA-DNA hybridization technique is suitable for the evaluation of the internal contamination of dental implants although further studies are necessary to validate the use of computational methods for the improvement of the test accuracy. To cite this article:do Nascimento C, Barbosa RES, Issa JPM, Watanabe E, Ito IY, Albuquerque Junior RF. Use of checkerboard DNA-DNA hybridization to evaluate the internal contamination of dental implants and comparison of bacterial leakage with cast or pre-machined abutments.Clin. Oral Impl. Res. 20, 2009; 571-577.doi: 10.1111/j.1600-0501.2008.01663.x.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent clinical studies, contamination of the inner parts of dental implants through bacterial penetration along the implant components has been observed. The aim of the present in-vitro study was to investigate leakage of Fusobacterium. nucleatum through the interface between implants and premachined or cast abutments. Both premachined (n = 10) and cast (n = 10) implant abutment assemblies were inoculated with 3.0 mu L of microbial inoculum. The assemblies were completely immersed in 5.0 mL of tryptic soy broth culture medium to observe leakage at the implant-abutment interface after 14 days of anaerobic incubation. Bacterial growth in the medium, indicative of microbial leakage, was found only in 1 out of 9 samples (11.1%) in each group. Both premachined and cast abutments connected to external hexagonal implants provide low percentages of bacterial leakage through the interface in in vitro unloaded conditions if the manufacturer`s instructions and casting procedures are properly followed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel biosensor for glucose was prepared by adsorption of 1,1`-bis(4-carboxybenzyl)-4,4`-bipyridinium di-bromide compound (H(2)BpybcBr(2)) onto the surface of a nanocrystalline TiO(2) film deposited onto FTO glasses, which was used as a platform to assemble the enzyme glucose oxidase to the electrode surface. The H(2)BpybcBr(2)/TiO(2)/FTO modified electrode was characterized by scanning electron microscopy, X-ray fluorescence image, cyclic voltammograms and spectroelectrochemical measurements. The immobilization of GOD on functionalized TiO(2) film led to stable amperometric biosensing for glucose with a linear range from 153 mu mol L(-1) to 1.30 mmol L(-1) and a detection limit of 51 mu mol L(-1). The apparent Michaelis-Menten constant (K(m)) was estimated to be 3.76 mmol L(-1), which suggested a high enzyme-substrate affinity. The maximum electrode sensitivity was 1.25 mu A mmol L(-1). The study proved that the combination of viologen mediators with TiO(2) film retains the electrocatalytic activity of the enzyme, and also enhances the electron transfer process, and hence regenerating the enzyme in the reaction with glucose. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of implant-supported prosthesis to replace missing teeth became a predictable treatment. Although high success rate has been reported, implant treatment is suitable to complications, failures, and limitations such as peri-implant bone loss after implant loading. Stress evaluation on the bone-abutment-implant interface has been carried out to develop new designs of prosthetic platform and to understand the stress distribution in this interface. Several types of prosthetic platforms are available such as external and internal hexagon, Morse cone connection, and the concept of platform switching. Therefore, this study aimed to critically describe the different options of prosthetic platforms in implant dentistry, by discussing their biomechanical concepts, clinical use, and advantages and disadvantages. It was observed that all types of prosthetic platforms provided high success rate of the implant treatment by following a strict criteria of indication and limitation. In conclusion, a reverse planning of implant treatment is strongly indicated to reduce implant overload, and the use of advanced surgical-prosthetic techniques is required to obtain a long-term success of oral rehabilitations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse taper were embedded in the center of each polyurethane block in straight placement and offset placement. Four strain gauges (SGs) were bonded on the surface of polyurethane block, which was designated SG1 placed mesially adjacent to implant A, SG2 and SG3 were placed mesially and distally adjacent to the implant B and SG4 was placed distally adjacent to the implant C. The 30 superstructures' occlusal screws were tightened onto the Microunit abutments with a torque of 10 N cm using the manufacturers' manual torque-controlling device.Results: There were statistically significant differences in prosthetic connection (P value = 0.0074 < 0.5). There were no statistically significant differences in placement configuration/alignment (P value = 0.7812 > 0.5).Conclusion: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants. (Implant Dent 2011; 20:e24-e32)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este artigo propõe a construção de uma interface entre história e ensino de matemática a partir de um diálogo entre historiadores e educadores da matemática. Para tanto, consideramos aspectos epistemológicos e metodológicos ligados à história da matemática, pautada em tendências historiográficas atuais, juntamente com a metodologia baseada no movimento lógico-histórico. A interface contemplou o movimento do pensamento na formação dos conceitos e o contexto no qual tais conceitos foram desenvolvidos, de modo a conduzir à reflexão sobre o processo histórico da construção do conhecimento para a elaboração de atividade didática. Esta atividade teve por base um documento do século XVI dedicado à construção e uso de instrumentos matemáticos, e sua elaboração levou em consideração uma intencionalidade e um plano de ação que viabilizaram o seu desenvolvimento. A organização do ensino articulou as conexões internas e externas trazidas pela análise do documento e a forma do pensamento do desenvolvimento do conceito.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Estudar as alterações agudas da interface entre os parafusos e o tecido ósseo vertebral, considerando o diâmetro do orifício-piloto em relação ao diâmetro interno do parafuso. MÉTODOS: O estudo foi realizado em carneiros e a segunda vértebra cervical selecionada para o estudo. Foram utilizados parafusos corticais de 3,5mm de diâmetro externo (2,4mm de diâmetro interno) e 14mm de comprimento. Foram formados quatro grupos experimentais: 1) orifício-piloto de 2,0mm e colocação do parafuso de 3,5mm; 2) orifício-piloto de 2,5mm e colocação do parafuso de 2,5mm; 3) orifício-piloto de 2mm sem colocação do parafuso; e 4) orifício-piloto de 2,5mm sem colocação do parafuso. RESULTADOS: O grupo 1 (orifício-piloto menor do que o diâmetro interno do parafuso) apresentou maior densidade óssea no interior da rosca do implante e maior densidade óssea na área em espelho do que o grupo 2 (orifício-piloto maior que o diâmetro interno do parafuso). A superfície de contato entre o tecido ósseo e o implante foi maior no grupo 2 em relação ao grupo 1. A comparação da densidade óssea na área em espelho entre os grupos com e sem implante (1 e 3) e (2 e 4) mostrou que a densidade óssea era maior nos grupos com o implante. Não foi observada diferença estatística entre as comparações dos grupos experimentais. CONCLUSÃO: A utilização de orifício-piloto de menor diâmetro em relação ao diâmetro interno do parafuso apresentou tendência a provocar maior compactação do osso ao redor do implante.