992 resultados para Infrared thermography


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Interfacial waves on the surface of a falling liquid film are known to modify heat and mass transfer. Under non-isothermal conditions, the wave topology is strongly influenced by the presence of thermocapillary (Marangoni) forces at the interface which leads to a destabilization of the film flow and potentially to critical film thinning. In this context, the present study investigates the evolution of the surface topology and the evolution of the surface temperature for the case of regularly excited solitary-type waves on a falling liquid film under the influence of a wall-side heat flux. Combining film thickness (chromatic confocal imaging) and surface temperature information (infrared thermography), interactions between hydrodynamics and thermocapillary forces are revealed. These include the formation of rivulets, film thinning and wave number doubling in spanwise direction. Distinct thermal structures on the films’ surface can be associated to characteristics of the surface topology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La termometría es una técnica no invasiva que permite cuantificar los cambios en la temperatura cutánea y evaluarla de forma cuantitativa. El aumento significativo de la temperatura puede indicar la existencia de patología. Se ha demostrado que la actividad muscular induce procesos de transferencia de calor entre los músculos y las capas superficiales de tejido. En este estudio queremos cuantificar los cambios de temperatura que se producen en los músculos del pie y miembro inferior tras una carrera de 30 km, para ello hemos utilizado una cámara termográfica de alta resolución. Contamos con la colaboración voluntaria de 32 sujetos sanos a los que procedimos a tomar fotografías de la planta del pie, parte anterior de la pierna, parte posterior de la pierna, parte anterior del muslo y parte posterior del muslo en dos etapas, primero antes de la carrera y segunda toma después de la carrera de 30 km, de esta manera pudimos valorar si había o no variación de temperatura en las zonas seleccionadas. Tras el análisis de los datos obtenidos encontramos significativas variaciones térmicas en Talón, cabeza primer metatarsiano, cabeza segundo metatarsiano, cabeza tercer metatarsiano, cabeza cuarto metatarsiano, cabeza quinto metatarsiano, apófisis estiloides quinto metatarsiano, arco longitudinal interno, maléolo interno, maléolo externo, peroneo lateral largo, vasto interno, vasto externo, recto femoral, tensor de la fascia lata, inserción cuádriceps, gemelo interno, tendón de Aquiles y Biceps femoral.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A civilização contemporânea, pelas suas características, é muito exigente em tudo o que diz respeito ao conforto dos edifícios, para trabalho ou habitação, e à necessidade de economizar e racionalizar o uso de energia. A térmica dos edifícios assume, por isso, uma importância acrescida na atividade profissional e no ensino. Para se conduzir ao aperfeiçoamento de soluções na envolvente dos edifícios a este nível, o trabalho aqui realizado centrou-se no estudo do funcionamento da termografia de infravermelhos e da importância da sua utilização na inspeção térmica de edifícios. Descoberta no início do século XIX e desenvolvendo os primeiros sistemas operativos desde a 1ª Guerra Mundial, a fim de determinar heterogeneidades de temperatura superficial, esta técnica não destrutiva permite identificar anomalias que não são visualizadas a olho nu. Com a análise dessas variações de temperatura é possível conhecer os problemas e a localização de irregularidades. Este trabalho baseia-se substancialmente no estudo de edifícios. A análise realizada teve como finalidade executar inspeções termográficas – visuais, com duas abordagens. Por um lado, avaliar salas pertencentes a estabelecimentos de ensino secundário, reabilitadas e não reabilitadas, todas construídas entre as décadas de 60 e 90, com o intuito de diagnosticar patologias construtivas, recorrendo à termografia. Por outro, a análise de edifícios de habitação, com a intenção de avaliar a necessidade de um equipamento complementar às inspeções termográficas – o sistema de porta ventiladora. As inspeções foram regidas pelas diretrizes da norma europeia EN 13187. A termografia é uma técnica importante na realização de ensaios in situ que requerem rapidez de execução, aliada à vantagem de disponibilizar resultados em tempo real, permitindo assim uma primeira análise das leituras no local. A inspeção termográfica complementada com o sistema de porta ventiladora permitiu, também, revelar a importância da necessidade de meios auxiliares em certos casos. A conjugação destas diferentes técnicas permite reduzir a subjetividade da análise in situ e aumentar a fiabilidade do diagnóstico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La guérison des plaies cutanées appendiculaires chez le cheval, à la différence de celle des plaies corporelles, se complique régulièrement. Un retard de cicatrisation s’y observe et un tissu de granulation exubérant tend à s’y développer, le tout menant à une cicatrice pathologique hypertrophiée. La pathogénie exacte du tissu de granulation exubérant chez le cheval demeure inconnue à ce jour. Une hypoxie tissulaire pourrait favoriser son développement tout comme elle semble contribuer au développement de cicatrices cutanées pathologiques similaires observées chez l’Homme. L’objectif de cette étude était d’évaluer la perfusion vasculaire et la disponibilité locale en oxygène de plaies cutanées appendiculaires et corporelles en cours de cicatrisation normale et pathologique chez le cheval, à l’aide de la thermographie infrarouge et de la spectroscopie par réflectance dans le proche infrarouge. Six juments âgées de 3 à 4 ans ont été utilisées. Trois plaies cutanées ont été créées à l’aspect dorso-latéral du canon des membres thoraciques (plaies appendiculaires), et sur la paroi costale de l’un des hémithorax (plaies corporelles). Chez chaque jument, un canon a été aléatoirement bandé dans le but d’induire la formation de tissu de granulation exubérant dans les plaies s’y trouvant, tel que rapporté. La perfusion vasculaire et la disponibilité locale en oxygène ont été évaluées séquentiellement par thermographie infrarouge et spectroscopie par réflectance dans le proche infrarouge pour chaque plaie de chaque site (thorax; membre bandé; membre non bandé) au cours du processus de cicatrisation cutanée. Un modèle linéaire à doubles mesures répétées associé à une correction séquentielle de Bonferroni a révélé des différences significatives de perfusion vasculaire et de disponibilité locale en oxygène entre les plaies appendiculaires et corporelles. Ainsi la perfusion vasculaire et la disponibilité locale en oxygène étaient significativement plus élevées dans les plaies corporelles (P<0.05) et la perfusion vasculaire était significativement plus élevée dans les plaies appendiculaires non bandées que dans celles bandées (P<0.05). Nous avons récemment rapporté une plus grande occlusion de la micro-vascularisation au niveau des plaies appendiculaires chez le cheval. Nous rapportons maintenant que la perfusion vasculaire et la disponibilité locale en oxygène sont significativement inférieures dans les plaies appendiculaires, en particulier lorsqu’un tissu de granulation exubérant s’y développe. Compilés, ces résultats sous-tendent l’hypothèse que les plaies appendiculaires souffrent d’une altération de la perfusion vasculaire à l’origine possible d’une hypoxie tissulaire qui pourrait favoriser une cicatrisation cutanée anormale, telle la formation d’un tissu de granulation exubérant.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main objective of this thesis was to determine the potential impact of heat stress (HS) on physiological traits of lactating cows and semen quality of bulls kept in a temperate climate. The thesis is comprised of three studies. An innovative statistical modeling aspect common to all three studies was the application of random regression methodology (RRM) to study the phenotypic and genetic trajectory of traits in dependency of a continuous temperature humidity index (THI). In the first study, semen quality and quantity traits of 562 Holstein sires kept on an AI station in northwestern Germany were analyzed in the course of THI calculated from data obtained from the nearest weather station. Heat stress was identified based on a decline in semen quality and quantity parameters. The identified general HS threshold (THI = 60) and the thermoneutal zone (THI in the range from 50 to 60) for semen production were lower than detected in studies conducted in tropical and subtropical climates. Even though adult bulls were characterized by higher semen productivity compared to younger bulls, they responded with a stronger semen production loss during harsh environments. Heritabilities (low to moderate range) and additive genetic variances of semen characteristics varied with different levels of THI. Also, based on genetic correlations genotype, by environment interactions were detected. Taken together, these findings suggest the application of specific selection strategies for specific climate conditions. In the second study, the effect of the continuous environmental descriptor THI as measured inside the barns on rectal temperatures (RT), skin temperatures (ST), vaginal temperatures (VT), respiration rates (RR), and pulse rate (PR) of lactating Holstein Friesian (HF) and dual-purpose German black pied cattle (DSN) was analyzed. Increasing HS from THI 65 (threshold) to THI 86 (maximal THI) resulted in an increase of RT by 0.6 °C (DSN) and 1 °C (HF), ST by 3.5 °C (HF) and 8 °C (DSN), VT by 0.3 °C (DSN), and RR by 47 breaths / minute (DSN), and decreased PR by 7 beats / minute (DSN). The undesired effects of rising THI on physiological traits were most pronounced for cows with high levels of milk yield and milk constituents, cows in early days in milk and later parities, and during summer seasons in the year 2014. In the third study of this dissertation, the genetic components of the cow’s physiological responses to HS were investigated. Heat stress was deduced from indoor THI measurements, and physiological traits were recorded on native DSN cows and their genetically upgraded crosses with Holstein Friesian sires in two experimental herds from pasture-based production systems reflecting a harsh environment of the northern part of Germany. Although heritabilities were in a low range (from 0.018 to 0.072), alterations of heritabilities, repeatabilities, and genetic components in the course of THI justify the implementation of genetic evaluations including heat stress components. However, low repeatabilities indicate the necessity of using repeated records for measuring physiological traits in German cattle. Moderate EBV correlations between different trait combinations indicate the potential of selection for one trait to simultaneously improve the other physiological attributes. In conclusion, bulls of AI centers and lactating cows suffer from HS during more extreme weather conditions also in the temperate climate of Northern Germany. Monitoring physiological traits during warm and humid conditions could provide precious information for detection of appropriate times for implementation of cooling systems and changes in feeding and management strategies. Subsequently, the inclusion of these physiological traits with THI specific breeding values into overall breeding goals could contribute to improving cattle adaptability by selecting the optimal animal for extreme hot and humid conditions. Furthermore, the recording of meteorological data in close distance to the cow and visualizing the surface body temperature by infrared thermography techniques might be helpful for recognizing heat tolerance and adaptability in cattle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper an analytical solution of the temperature of an opaque material containing two overlapping and parallel subsurface cylinders, illuminated by a modulated light beam, is presented. The method is based on the expansion of plane and cylindrical thermal waves in series of Bessel and Hankel functions. This model is addressed to the study of heat propagation in composite materials with interconnection between inclusions, as is the case of inverse opals and fiber reinforced composites. Measurements on calibrated samples using lock-in infrared thermography confirm the validity of the model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed at evaluating the thermographic changes associated with localized exercise in young and elderly subjects. An exercise protocol using 1 kg load was applied during 3 min to the knee flexors of 14 elderly (67 +/- 5 years) and 15 young (23 +/- 2 years) healthy subjects. The posterior thigh`s skin temperature of the exercised limb and contralateral limb were measured by infrared thermography on pre-exercise, immediately post-exercise, and during the 10-min period post-exercise. Difference (p < 0.01) between elderly and young subjects was observed on pre-exercise temperature. Although differences were not observed between pre-exercise and immediately post-exercise temperature in the exercised limb, thermographic profile displayed heat concentration in exercised areas for both groups. Temperature reduction was only observed for the young group on the 10-min post-exercise (p < 0.05) in the exercised limb (30.7 +/- 1.7 to 30.3 +/- 1.5 degrees C). In contrast, there was a temperature reduction post-exercise (p < 0.01) in the contralateral limb for both groups. These results present new evidences that elderly and young subjects display similar capacity of heat production; however, the elderly subjects presented a lower resting temperature and slower heat dissipation. This work contributes to improve the understanding about temperature changes in elderly subjects and may present implications to the sports and rehabilitation programs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Industrial application of infrared thermography is virtually boundless as it can be used in any situations where there are temperature differences. This technology has particularly been widely used in automotive industry for process evaluation and system design. In this work, thermal image processing technique will be introduced to quantitatively calculate the heat stored in a warm/hot object and consequently, a thermal control system will be proposed to accurately and actively manage the thermal distribution within the object in accordance with the heat calculated from the thermal images.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

High pressure die casting (HPDC) is a versatile process for producing engineered metal parts by forcing molten metal under high pressure into reusable steel dies. However there are a large number of attributes involved which contribute to the complexity of the process. A novel integrated approach is developed to optimize the high pressure die casting processes. The die temperature profiles will be studied with infrared thermograph technology and the internal cooling system will be optimized to provide even cooling to the components and the die. The heat stored in the die and the components is studied with image processing. Based on the geometrical profile of the components, cooling channels can be redesigned to improve the cooling efficiency while the cooling time is reduced. This will not only significantly improve the quality of the castings but also improve the productivity of the process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Multiwalled carbon nanotubes (MWCNTs) were dispersed in an aqueous solution of epichlohydrin based resin with the aid of a surfactant. The MWCNT-resin solutions were applied onto cotton fabrics to form a thin coating with different MWCNT contents (0, 11.1, 20.0, 33.3, and 50%). The thermal conductivity of the fabrics was measured based on the Newton’s law of cooling. The coating containing 50% MWCNTs showed 151% increase in the thermal conductivity. Infrared thermography was used to characterize the heating/cooling behavior of the fabrics. On contact with a 50°C hot surface, coated fabric that had 50% MWCNTs in the coating layer showed a 3.9°C lower equilibrium surface temperature than the untreated fabric. The cooling rate increased with increasing the MWCNT content within the coating layer. Such an effective cooling performance was attributed to the increased thermal conductivity and surface emissivity of the MWCNT-containing coating layer. The coating showed little influence on water contact angle of the coated fabrics, but slightly decreased the air permeability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Our goal was to investigate the surface temperature variations in the cervical region via infrared thermography, as well as the temperature within the pulp chamber via thermocouples, of mandibular incisors when subjected to dental bleaching using two different 35% hydrogen peroxide gels, red (HP) and green (HPM), when activated by halogen light (HL) and LED light.Background Data: Temperatures increases of more than 5.5 degrees C are considered to be potentially threatening to pulp vitality, while those higher than 10 degrees C can result in periodontal injury.Materials and Methods: Tooth samples were randomly divided into four groups (n = 10 each), according to the bleaching agent and catalyst light source used.Results: Mean values and standard deviations of the temperature increases inside the pulp chamber in the HL groups were 4.4 degrees +/- 2.1 degrees C with HP, and 4.5 degrees +/- 1.2 degrees C with HPM; whereas in the groups using LED light, they were 1.4 degrees +/- 0.3 degrees C for HP, and 1.5 degrees +/- 0.2 degrees C for HPM. For the root surfaces, the maximum temperature increases in the groups irradiated with HL were 6.5 degrees +/- 1.5 degrees C for HP, and 7.5 degrees +/- 1.1 degrees C with HPM; whereas in the groups irradiated with LED light, they were 2.8 degrees +/- 0.7 degrees C with HP, and 3 degrees +/- 0.8 degrees C with HPM. There were no statistically significant differences in pulp and surface temperature increases between the groups using different gels, although the mean temperature increases were significantly higher for the groups irradiated with HL when compared with those irradiated with the LED light (p < 0.05 with Tukey's test).Conclusion: LED light may be safe for periodontal and pulp tissue when using this method, but HL should be used with care.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)