356 resultados para Imãs


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, a machine learning technique called anomaly detection is employed for wind turbine bearing fault detection. Basically, the anomaly detection algorithm is used to recognize the presence of unusual and potentially faulty data in a dataset, which contains two phases: a training phase and a testing phase. Two bearing datasets were used to validate the proposed technique, fault-seeded bearing from a test rig located at Case Western Reserve University to validate the accuracy of the anomaly detection method, and a test to failure data of bearings from the NSF I/UCR Center for Intelligent Maintenance Systems (IMS). The latter data set was used to compare anomaly detection with SVM, a previously well-known applied method, in rapidly finding the incipient faults.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with a finite element modelling method for thin layer mortared masonry systems. In this method, the mortar layers including the interfaces are represented using a zero thickness interface element and the masonry units are modelled using an elasto-plastic, damaging solid element. The interface element is formulated using two regimes; i) shear-tension and ii) shearcompression. In the shear-tension regime, the failure of joint is consiedered through an eliptical failure criteria and in shear-compression it is considered through Mohr Coulomb type failure criterion. An explicit integration scheme is used in an implicit finite element framework for the formulation of the interface element. The model is calibrated with an experimental dataset from thin layer mortared masonry prism subjected to uniaxial compression, a triplet subjected to shear loads a beam subjected to flexural loads and used to predict the response of thin layer mortared masonry wallettes under orthotropic loading. The model is found to simulate the behaviour of a thin layer mortated masonry shear wall tested under pre-compression and inplane shear quite adequately. The model is shown to reproduce the failure of masonry panels under uniform biaxial state of stresses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The inverse temperature hyperparameter of the hidden Potts model governs the strength of spatial cohesion and therefore has a substantial influence over the resulting model fit. The difficulty arises from the dependence of an intractable normalising constant on the value of the inverse temperature, thus there is no closed form solution for sampling from the distribution directly. We review three computational approaches for addressing this issue, namely pseudolikelihood, path sampling, and the approximate exchange algorithm. We compare the accuracy and scalability of these methods using a simulation study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experiments were conducted to determine the fate of bensulfuron-methyl (BSM) and imazosulfuron (IMS) under paddy conditions. Initially, laboratory experiments were conducted and the photolysis half-lives of the two herbicides were found to be much shorter than their hydrolysis half-lives in aqueous solutions. In the aerobic water–soil system, dissipation followed first-order kinetics with water half-lives of 9.1 and 11.0 days and soil half-lives of 12.4 and 18.5 days (first phase) and 35.0 and 44.1 days (second phase) for bensulfuron-methyl and imazosulfuron, respectively. However, the anaerobic soil half-lives were only 12.7 and 9.8 days for BSM and IMS, respectively. The values of K d were determined to be 16.0 and 13.8 for BSM and IMS, respectively. Subsequent field measurements for the two herbicides revealed that dissipation of both herbicides in paddy water involved biphasic first-order kinetics, with the dissipation rates in the first phase being much faster than those in the second phase. The dissipation of bensulfuron-methyl and imazosulfuron in the paddy surface soil were also followed biphasic first-order kinetics. These results were then used as input parameters for the PCPF-1 model to simulate the fate and transport of BSM and IMS in the paddy environment (water and 1-cm surface soil layer). The measured and simulated values agreed well and the mass balance error during the simulation period was −1.2 and 2.8% of applied pesticide, respectively, for BSM and IMS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A geometrical structure called the implied minterm structure (IMS) has been developed from the properties of minterms of a threshold function. The IMS is useful for the manual testing of linear separability of switching functions of up to six variables. This testing is done just by inspection of the plot of the function on the IMS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The conferencing systems in IP Multimedia (IM) networks are going through restructuring, accomplished in the near future. One of the changes introduced is the concept of floors and floor control in its current form with matching entity roles. The Binary Floor Control Protocol (BFCP) is a novelty to be exploited in distributed tightly coupled conferencing services. The protocol defines the floor control server (FCS), which implements floor control giving access to shared resources. As the newest tendency is to distribute the conferencing services, the locations of different functionality units play an important role in developing the standards. The floor control server location is not yet single-mindedly fixed in different standardization bodies, and the debate goes on where to place it within the media server, providing the conferencing service. The thesis main objective is to evaluate two distinctive alternatives in respect the Mp interface protocol between the respective nodes, as the interface in relation to floor control is under standardization work at the moment. The thesis gives a straightforward preamble in IMS network, nodes of interest including floor control server and conferencing. Knowledge on several protocols – BFCP, SDP, SIP and H.248 provides an important background for understanding the functionality changes introduced in the Mp interface and therefore introductions on those protocols and how they are connected to the full picture is given. The actual analysis on the impact of the floor control server into the Mp reference point is concluded in relation to the locations, giving basic flows, requirements analysis including a limited implementation proposal on supporting protocol parameters. The overall conclusion of the thesis is that even if both choices are seemingly useful, not one of the locations is clearly the most suitable in the light of this work. The thesis suggests a solution having both possibilities available to be chosen from in separate circumstances, realized with consistent standardization. It is evident, that if the preliminary assumption for the analysis is kept regarding to only one right place for the floor control server, more work is to be done in connected areas to discover the one most appropriate location.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a five-level inverter scheme with four two-level inverters for a four-pole induction motor (IM) drive. In a conventional three-phase four-pole IM, there exists two identical voltage-profile winding coil groups per phase around the armature, which are connected in series and spatially apart by two pole pitches. In this paper, these two identical voltage-profile pole-pair winding coils in each phase of the IM are disconnected and fed from four two-level inverters from four sides of the windings with one-fourth dc-link voltage as compared to a conventional five-level neutral-point-clamped inverter. The scheme presented in this paper does not require any special design modification for the induction machine. For this paper, a four-pole IM drive is used, and the scheme can be easily extended to IMs with more than four poles. The proposed scheme is experimentally verified on a four-pole 5-hp IM drive.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study is focused on the development and evaluation of ion mobility instrumentation with various atmospheric pressure ionization techniques and includes the following work. First, a high-resolution drift tube ion mobility spectrometer (IMS), coupled with a commercial triple quadrupole mass spectrometer (MS), was developed. This drift tube IMS is compatible with the front-end of commercial Sciex mass spectrometers (e.g., Sciex API-300, 365, and 3000) and also allows easy (only minor modifications are needed) installation between the original atmospheric pressure ion source and the triple quadrupole mass spectrometer. Performance haracteristics (e.g.,resolving power, detection limit, transmission efficiency of ions) of this IMS-MS instrument were evaluated. Development of the IMS-MS instrument also led to a study where a proposal was made that tetraalkylammonium ions can be used as chemical standards for ESI-IMS. Second, the same drift tube design was also used to build a standalone ion mobility spectrometer equipped with a Faraday plate detector. For this highresolution (resolving power about 100 shown) IMS device, a multi-ion source platform was built, which allows the use of a range of atmospheric pressure ionization methods, such as: corona discharge chemical ionization (CD-APCI), atmospheric pressure photoionization (APPI), and radioactive atmospheric pressure chemical ionization (R-APCI). The multi-ion source platform provides easy switching between ionization methods and both positive and negative ionization modes can be used. Third, a simple desorpion/ionization on silicon (DIOS) ion source set-up for use with the developed IMS and IMS-MS instruments was built and its operation demonstrated. Fourth, a prototype of a commercial aspiration-type ion mobility spectrometer was mounted in front of a commercial triple quadrupole mass spectrometer. The set-up, which is simple, easy to install, and requires no major modifications to the MS, provides the possibility of gathering fundamental information about aspiration mobility spectrometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN]A study was conducted on crossbred steers (n=275; 376±924 kg) to evaluate performance and carcass quality of cattle fed wheat or corn dried distillers’ grains with solubles (DDGS). The control ration contained 86.6% rolled barley grain, 5.7% supplement and 7.7% barley silage (DM basis). The four treatments included replacement of barley grain at 20 or 40% of the diet (DM basis) with wheat or corn DDGS. Steers were slaughtered at a common end weight of 645 kg with 100 steers randomly (n=20 per treatment) selected for determination of the retail yield of sub-primal boneless boxed beef (SPBBB). Data were analyzed as a completely randomized design using pen as the experimental unit. Feeding increasing levels of wheat DDGS led to a quadratic increase in dry matter intake (DMI) (P<0.01), whereas increasing levels of corn DDGS led to a quadratic decrease in DMI (P=0.01). Average daily gain was not influenced (P=0.13) by feeding wheat or corn DDGS, but cattle fed corn DDGS exhibited a quadratic increase (P=0.01) in gain:feed. As a result, a quadratic increase (P<0.01) in calculated NEg of the diet was observed as corn DDGS levels increased. A linear decrease (P=0.04) in days on feed (169, 166 and 154 d) was noted when increasing levels of wheat DDGS (0, 20 and 40%) were fed. Dressing percentage increased in a linear fashion with wheat DDGS (P<0.01) inclusion level and in a quadratic fashion (P=0.01) as corn DDGS inclusion level increased although other carcass traits were not affected (P=0.10) by treatment. The results indicate that replacement of barley grain with corn or wheat DDGS up to 40% of the diet (DM) can lead to superior performance (improved gain:feed or reduced days on feed, respectively) with no detrimental effect on quality grade or carcass SPBBB yield.