Doxorubicin (DOX), a member of the anthracycline group, is a widely used drug in cancer therapy. The mechanisms of DOX action include topoisomerase II-poisoning, free radical release, DNA adducts and interstrand cross-link (ICL) formation. Nucleotide excision repair(NER) is involved in the removal of helix-distorting lesions and chemical adducts, however, little is known about the response of NER-deficient cell lines to anti-tumoral drugs like DOX. Wild type and XPD-mutated cells, harbouring mutations in different regions of this gene and leading to XP-D, XP/CS or TTD diseases, were treated with this drug and analyzed for cell cycle arrest and DNA damage by comet assay. The formation of DSBs was also investigated by determination of gamma H2AX foci. Our results indicate that all three NER-deficient cell lines tested are more sensitive to DOX treatment, when compared to wild type cells or XP cells complemented by the wild type XPD cDNA, suggesting that NER is involved in the removal of DOX-induced lesions. The cell cycle analysis showed the characteristic G2 arrest in repair-proficient MRC5 cell line after DOX treatment, whereas the repair-deficient cell lines presented significant increase in sub-G1 fraction. The NER-deficient cell lines do not show different patterns of DNA damage formation as assayed by comet assay and phosphorylated H2AX foci formation. Knock-down of topoisomerase II alpha with siRNA leads to increased survival in both MRC5 and XP cells, however, XP cell line still remained significantly more sensitive to the treatment by DOX. Our study suggests that the enhanced sensitivity is due to DOX-induced DNA damage that is subject to NER, as we observed decreased unscheduled DNA synthesis in XP-deficient cells upon DOX treatment. Furthermore, the complementation of the XPD-function abolished the observed sensitivity at lower DOX concentrations, suggesting that the XPD helicase activity is involved in the repair of DOX-induced lesions. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To review the effects of contact lenses on the corneal surface.

Methods: A review of the literature and in-house research of corneal staining and its various forms of presentation.

Results: Corneal staining manifests in many different forms. The severity of staining or insult of the cornea is usually determined by the extent (area of coverage), density, and depth. The cause of staining is multifactorial, and its location is often linked to the type of lens that is being worn, the solution used to clean/disinfect the lens, the state of hydration of the soft lens, and the state of the cornea that has been affected by the lens.

Conclusions: Sodium fluorescein dye effectively highlights corneal integrity changes referred to as corneal staining. This review describes the manifestations, the cause, the mechanisms, and the methods of remediation of corneal staining.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Tear meniscus height (TMH) is an indirect measurement of tear film volume. This study investigated the temporal changes in the TMH during the blink interval in the morning (8–9 am) and at the end of the day (5–6 pm) in both soft contact lens (CL) and nonlens wearers (NLW).

Methods: Fifty participants (25 CL; 25 NLW) were evaluated for their subjective symptoms, TMH, noninvasive break up time, and bulbar hyperemia at the am and pm visits on the same day. The TMH was measured at set intervals between 2 and 15 sec during the blink interval, using an optical coherence tomographer.

Results: The NLW group revealed no changes in a variety of symptoms during the day, whereas the CL group reported an increase in dryness (P=0.03) and grittiness (P=0.02) over the day. For both groups, the TMH and calculated tear meniscus volume revealed lower values immediately after the blink and increased progressively afterwards, mainly due to reflex tearing. The am tear meniscus volume values tended to be higher than the pm values for both groups, but this was not significant (NLW P=0.13; CL P=0.82). Noninvasive break up time deteriorated during the day for both groups but was only significant for the CL group (P=0.002), whereas bulbar hyperemia revealed no statistically significant change for either group.

Conclusions: Reflex tearing may play a substantial role in the TMH differences observed over the blink interval. Standardization of the time when a TMH measurement is performed will be valuable in comparing tear film clinical studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine whether the refractive index (RI) of a soft contact lens can be evaluated using refractometry while the lens remains on the eye and to compare this with more traditional ex vivo RI measurements.

Methods: A slitlamp apparatus was modified to incorporate a customized Atago hand refractometer. With a double-masked study design, nine adapted symptomatic soft contact lens wearers wore a contact lens in each eye (lotrafilcon B and etafilcon A) in a randomized order. In vivo RI was determined from the relative Brix scale measurements immediately after lens insertion and after 1 and 10 hr of lens wear. Ex vivo refractometry was performed after 10 hr of lens wear for comparison. Means ± standard errors of the means are reported.

Results: In vivo RI values at baseline were 1.422 ± 0.0004 (lotrafilcon B) and 1.405 ± 0.0021 (etafilcon A); after 1 hr of lens wear, values were 1.423 ± 0.0006 and 1.408 ± 0.0007, respectively; and after 10 hr of lens wear, values were 1.424 ± 0.0004 and 1.411 ± 0.0010, respectively. Ex vivo RI values at the end of the 10 hr wearing period were 1.424 ± 0.0003 (lotrafilcon B) and 1.412 ± 0.0017 (etafilcon A). The change in in vivo RI across the day was statistically significant for the etafilcon A lens (repeated-measures analysis of variance, P<0.01) but not for the lotrafilcon B lens (P>0.05).

Conclusions: This novel adaptation of refractometry was able to measure the RI of soft contact lenses during wear (without lens removal). End of day RI measurements using in vivo and ex vivo refractometry were comparable with each other. Future work is required to determine whether this in vivo method can improve our understanding of the relationships between soft contact lens RI, hydration, on-eye lens performance, and symptomology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare the performance of a low-addition silicone hydrogel multifocal soft lens with other soft lens correction options in a group of habitual soft lens wearers of distance correction who are symptomatic of early presbyopia.

Method: This clinical study was designed as a prospective, double-masked, randomized, crossover, dispensing trial consisting of four 1-week phases, one for each of the correction modalities: a low-addition silicone hydrogel multifocal soft lens, monovision, habitual correction, and optimized distance visual correction. The prescriptions of all modalities were finalized at a single fitting visit, and the lenses were worn according to a randomized schedule. All lenses were made from lotrafilcon B material. A series of objective vision tests were conducted: high- and low-contrast LogMAR under high- and low-room lighting conditions, stereopsis, and critical print size. A number of other data collection methods used were novel: some data were collected under controlled laboratory-based conditions and others under real-world conditions, some of which were completed on a BlackBerry hand-held communication device.

Results: All participants were able to be fit with all four correction modalities. Objective vision tests showed no statistical difference between the lens modalities except in the case of low-contrast near LogMAR acuity under low-lighting levels where monovision (+0.29 ± 0.10) performed better than the multifocal (+0.33 ± 0.11, P=0.027) and the habitual (+0.37 ± 0.12, P<0.001) modalities. Subjective ratings indicated a statistically better performance provided by the multifocal correction compared with monovision, particularly for the vision associated with driving tasks such as driving during the daytime (93.3 ± 8.8 vs. 84.2 ± 23.7, P=0.05), at nighttime (88.8 ± 11.7 vs. 74.9 ± 23.6, P=0.001), any associated haloes or glare (92.0 ± 10.6 vs. 78.0 ± 22.8, P=0.003), and observing road signs (90.1 ± 11.8 vs. 79.4 ± 20.2, P=0.027). Preference for the multifocal compared with monovision was also reported when watching television (95.0 ± 6.4 vs. 82.6 ± 20.1, P=0.001) and when changing focus from distance to near (87.0 ± 13.4 vs. 66.1 ± 32.2, P<0.001).

Conclusions: For this group of early presbyopes, the AIR OPTIX AQUA MULTIFOCAL-Low Add provided a successful option for visual correction, which was supported by the results of subjective ratings, many of which were made during or immediately after performing such activities as reading, using a computer, watching television, and driving. These results suggest that making a prediction of success or not based on consulting room acuity tests alone is probably unwise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The objectives of this study were to assess current recommendations for replacement frequency (RF) of silicone hydrogel (SH) and daily disposable (DD) lenses, to determine compliance with these recommendations, and to investigate the reasons given for noncompliance.

Methods: A package containing 20 patient surveys was sent to 309 eye care practitioners (ECPs) in the United States who had agreed to participate in the study. One thousand eight hundred fifty-nine completed surveys were received from 158 ECPs and 1,654 surveys were eligible for analysis. Questions related to patient demographics, lens type, lens wearing patterns, the ECP instructions for RF, and the actual patient reported RF. ECPs were asked to provide lens information and their recommendation for RF after the surveys had been completed and sealed in envelopes. All responses were anonymous.

Results: Sixty-six percent of patients were women and their mean age was 34 ± 12 years. Eighty-eight percent of lenses were worn for daily wear, 12.8 ± 3.2 hours a day, 6.2 ± 1.5 days a week. Lens type distribution was 16% DD, 45% 2 week (2W) SH, and 39% 1 month (1M) SH. ECP recommendations for RF varied according to the lens type; 1% of 1M (95% CI 0.2-1.7), 4% of DD (95% CI 2.1-7.2), and 18% of 2W (95% CI 15.1-20.7) patients were given instructions that did not conform to the manufacturers' recommended RF (MRRF). When considering only those patients who were given the correct instructions for RF, 38% were not compliant with the MRRF; noncompliance rates varied according to the lens type and were 12% for DD (95% CI 8.6-17.2), 28% for 1M (95% CI 24.9-32.1), and 52% for 2W (95% CI 47.8-55.8). The most frequent reasons for over wearing lenses were forgetting which day to replace lenses (51%) and to save money (26%). Fifty-three percent believed that a reminder system would aid compliance; the most popular methods being a cell phone reminder or text message (29%) and a nominated day each week or month (26%). Discussions between the ECPs and the patients were more extensive for patients who were compliant with the MRRF.

Conclusions: ECPs recommended RFs more frequently with DD and 1M SH lenses than with 2W SH lenses, consistent with manufacturers' recommendations. Patients were less compliant with RF than ECPs for all lens types investigated. Patients were most compliant with RF when wearing DD lenses and least compliant when wearing 2W SH lenses. Better communication facilitated greater compliance with RF. More than half of those not replacing lenses, when recommended, reported that this was because they forgot which day to replace their lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To investigate the efficacy of a novel ocular lubricant compared with a commercially marketed ocular lubricant in a group of noncontact lens wearers currently using over-the-counter products for the management of symptoms of moderate to severe dry eye.

Methods: This was a prospective, double-masked study that randomized 110 subjects in a ratio of 1:1 to receive a novel ocular lubricant (test group) or a marketed ocular lubricant (control group). Subjects were instructed to instill the lubricant eye drops at least three times daily. After enrollment, subjects were evaluated at baseline and at 7 and 30 days. They were also required to complete a series of home-based subjective questionnaires after 15 days. Main outcomes were subjective symptoms and objective clinical assessment at 7 and 30 days.

Results: The test group had higher overall comfort ratings than the control group (P = 0.012). Seventy-one percent of the test group and 57% of the control group said the drops used “somewhat” or “definitely” improved ocular comfort; 62% of the test group had greater end-of-day comfort compared with 45% of the control group (P = 0.015). There were no between-group differences in visual acuity, tear quality or quantity, corneal staining, conjunctival staining, or bulbar and limbal conjunctival hyperemia.

Conclusions: The novel ocular lubricant offers equivalent or superior comfort compared with a marketed lubricant eye drop. Objective clinical outcomes were not statistically significantly different between the two groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To establish if evaluations of multifocal contact lens performance conducted at dispensing are representative of behavior after a moderate adaptation period.

Methods: Eighty-eight presbyopic subjects, across four clinical sites, wore each of four multifocal soft contact lenses (ACUVUE BIFOCAL, Focus Progressives, Proclear Multifocal, and SofLens Multifocal) for 4 days of daily wear. Comprehensive performance assessments were conducted at dispensing and after 4 days wear and included the following objective metrics: LogMAR acuity (contrast, 90% and 10%; illumination, 250 and 10 cd/m2; distance, 6 m, 100 cm, and 40 cm), stereopsis (RANDOT), reading critical print size and maximum speed and range of clear vision at near. Subjective assessments were made, with 100-point numerical rating scales, of comfort, ghosting (distance, near), visual quality (distance, intermediate, and near), and the appearance of haloes. At two sites, subjects (n = 39) also rated visual fluctuation (distance, intermediate, and near), facial recognition, and overall satisfaction.

Results: Among the objective variables, significant differences (paired t test, P<0.05) between dispensing and 4 days were found only for range of clear vision at near (2.9 ± 2.0 cm; mean difference ± standard deviation) and high contrast near acuity in low illumination (-0.013 ± 0.011 LogMAR). With the exception of insertion comfort, all subjective variables showed significant decrements over the same period. Overall satisfaction declined by an average of 10.9 ± 5.1 points.

Conclusions: Early assessment is relatively unrepresentative of performance later on during multifocal contact lens wear. Acuity based measures of vision remain substantially unchanged over the medium term, apparently because these metrics are insensitive indicators of performance compared with subjective alternatives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the compatibility of a new silicone hydrogel lens, asmofilcon A (with four multipurpose disinfecting solutions: OPTIFREE RepleniSH, ReNu MultiPlus, Solo-Care Aqua and MeniCare Soft). Ocular responses and subjective responses were monitored with each lens-care system combination.

Methods: The study was conducted as a prospective, bilateral, clinical trial with a single-masked investigator, and randomized cross-over design with four phases, (one for each care system). Each study phase comprised of two consecutive days of lens wear where the lenses were inserted on day 1 directly from the blister-packs and worn for over 8 hr, then inserted on day 2 after overnight disinfection with one of the study lens care systems. Twenty-five adapted soft contact lens wearers who were able to wear their habitual lenses comfortably for more than 12 hr were recruited.

Results: There were statistically significant differences in corneal staining found for all the lens-care systems when comparing the results of day 1 (from the blister pack) with day 2 (following care system use) (P < 0.05). ReNu MultiPlus solution had the highest grade for corneal staining at the 2-hr time point on day 2 which then decreased by 6 hr (P < 0.05). There was no difference between the lens care systems and the rating of subjective comfort over either of the two days. The rating of dryness and burning sensations were only slightly increased at 6 hr for all lens care systems except ReNu MultiPlus where burning was highest on insertion (P < 0.05).

Conclusion: Corneal staining observed in this study does not seem to have been related to the presence of polyhexamethylene biguanide (0.0001% wv) that was present in three of the four care systems. Only one care system (ReNu MultiPlus) demonstrated an associated level of corneal staining that was statistically significant; however, this was not considered to be of clinical relevance. These results suggest that using this novel surface-treated silicone hydrogel lens may result in less lens and lens care-related interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To clinically evaluate long-term users of two different contact lens care preservative systems and to investigate whether prolonged use is associated with an increase in the prevalence of dry eye.

Methods: Eighty-nine wearers of group IV hydrogel or silicone hydrogel lenses participated in this one-visit, investigator-masked study. Subjects were required to have consistently used a polyhexamethylene biguanide (PHMB) or polyquaternium-1 (PQT) based solution for 2 years. Consistent use was defined as 80% for the past 2 years and 100% for the past year. Clinical assessments included: average and comfortable wear time; overall and end-of-day comfort; signs of dryness, discomfort, burning or stinging, grittiness or scratchiness and visual changes; non-invasive and fluorescein break-up-time; pre-ocular tear film lipids, tear meniscus height, Schirmer and fluorescein clearance tests; limbal and bulbar hyperemia; palpebral roughness; corneal and conjunctival staining; lens front surface wetting; and lens film deposits.

Results: Significantly more grittiness or scratchiness was reported by subjects using a PHMB-containing system (67% vs. 44%; P = 0.02). Palpebral roughness and hyperemia were significantly greater in the PHMB group wearing group IV lenses (P = 0.01 and P = 0.05, respectively). Corneal staining was significantly higher in the PHMB users in all four peripheral sectors (P < 0.01). Nasal and temporal conjunctival staining was also significantly higher for users of PHMB-containing systems (P < 0.05). Front surface lens wettability was significantly better for group IV PQT users compared to PHMB users (P = 0.008), with 84% vs. 72%, respectively, with lenses graded by the investigator as having good or excellent wettability. Significantly higher levels of lens front surface film deposits were noted with PHMB users (P = 0.007), with 58% of group IV lenses treated with PHMB compared with 38% of group IV lenses treated with PQT showing some lens front surface film deposition. No significant differences between the two preservative system groups were noted for the range of dry eye evaluations nor the remaining clinical assessments.

Conclusions: Differences in both ocular and lens characteristic were observed between long-term users of two preservative systems used in many contact lens multi-purpose solutions. The findings from this study did not support the hypothesis that prolonged use of PHMB-containing solutions leads to dry eye. Additional studies including a larger sample size and perhaps longer use of the systems could help to further elucidate differences in clinical performance between systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Visual analog scales are frequently used as a means of allowing participants to rate symptoms during clinical trials. The accuracy and reproducibility of these scales play an important role in determining the experimental value of the data they provide. This study was initiated to compare the data collected using paper- and computer-based (Tablet PC) analog scales to better understand the variability in data provided by a visual analog scale.

Methods: Thirty participants rated ocular comfort, redness, and clarity of vision (right and left eyes) on a nondemarcated horizontal line on both paper and a Tablet PC. Measurements were taken in the morning between the hours of 8:30 and 10:30 am and again the same day between 2:30 and 4:30 pm.

Results: The mean difference between the measures recorded in the morning for the 2 media was 2.6 ± 0.9 (confidence intervals, 2 standard errors of the differences) units on a 100 unit scale, with the Tablet PC having the higher mean measure. The limits of agreement (2 standard deviations of the differences) was 9.4 units. Comparing the difference of the differences (1.0 ± 1.3) between the 2 methods of measure (morning vs. afternoon) the visual analog scales on the Tablet PC seemed to have good reproducibility of agreement in comparison with the paper version.

Conclusions: Discrepancy analysis yielded no significant difference and slight bias between paper- and computer-based analog scales. Repeatability of measures using the Tablet PC was also demonstrated. These results suggest that the choice of medium does not significantly influence the outcome for subjective analog scales.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To investigate initial comfort and adaptation of currently successful low oxygen transmissibility soft lens wearers refitted with silicone hydrogel (SH) lenses for daily wear.

Methods. Fifty-five subjects were enrolled in a subject-masked 5-month clinical trial in which they wore 5 SH lenses in a randomized, crossover design. Comfort, burning, and dryness were rated on scales of 0 to 100 immediately on insertion and the time for lens settling was recorded. Symptoms were then rated at various times, using BlackBerry wireless communication devices (Research in Motion, Waterloo, Canada), during the day for 2 cycles of 2 weeks wear for each lens type.

Results. Comfort immediately on insertion varied between lens types (P=0.002). All lens types were reported by the subjects to have settled within 30 to 45 sec of insertion (P=0.14) and settled comfort was greater than comfort immediately on insertion (P<0.001). Comfort within the first hour of wear also varied between lens types (P=0.02). Comfort during the day decreased significantly for all lenses (P=0.001), but there was no difference between lenses (P=0.19) and no effect of lens age (P=0.15). The wearing times were greater with the SH lenses than the habitual lenses worn before study commencement (P=0.001). Overall performance of the lenses after 4 weeks was high, with no difference between lenses (P=0.45).

Conclusions. Initial comfort and adaptation to all SH lenses were good and no differences in the overall ratings were found between the 5 SH lenses investigated. Decreased comfort was noted later in the day with all lens types, but longer wearing times were reported with the SH lenses than previous hydroxyethyl methacrylate-based lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contact lenses can affect the cornea in a variety of ways. Corneal structure can be altered so that its thickness changes to involve the epithelium and the stroma. As a result, the curvature may be affected, but whether it is the front or the back surface that is affected depends on the type of lens used. If thickness increases sufficiently, corneal transparency may decrease. Contact lenses can also affect cellular structure of all layers of the cornea through mechanical trauma, hypoxia, or toxicity from solutions that are used in association with lenses. More serious complications, such as inflammation and infection, can arise. All these changes can be detected by clinicians using slitlamp biomicroscopes and keratometers if the changes are significant enough. Since the development of computers, optical instruments have become more sophisticated and have enabled the detection of subtle changes but have also facilitated more precise measurement of these conditions along with the ability to capture images of the alterations or defects. This article describes some of the newer techniques and, specifically, the application of optical coherence tomography, confocal microscopy, and esthesiometry.